Aztec System Boiler Installation Manual
4
3.2 Technical Assistance
Step 1: Always contact your installer in the first instance, which
must thoroughly check all his work PRIOR to requesting a service
visit from T R Engineering Ltd for assistance.
Step 2: If your appliance has developed an in-guarantee fault your
installer should contact T R Engineering Ltd for assistance.
What happens if my installer/engineer is unavailable?
Step 3: Contact T R Engineering Ltd. We will provide you with the
name and telephone number of our service agent. However, a
charge may apply if the fault is not covered by the appliance
guarantee (payment will be requested on site by our independent
service agent.
PLEASE NOTE: UNAUTHORISED INVOICES FOR ATTENDANCE AND
REPAIR WORK CARRIED OUT ON THIS APPLIANCE BY ANY THIRD
PARTY WILL NOT BE ACCEPTED BY T R ENGINEERING LTD.
Service Centre and Technical Support
Tel: 0114 257 2300
Fax: 0114 257 1419
Hours of Business
Monday to Thursday 8:30am –5pm
Friday 8:30am –2:30pm
4. Introduction
The Aztec electric system boiler is a wall mounted electric central
heating boiler designed with smaller properties in mind. Fitted
vertically only and requiring access to the front and the right hand
side of the boiler for servicing. Once the boiler is switched on it is
fully controlled by an automatic management system which
monitors the safety and running functions of the boiler. Designed to
work on a fully pumped wet system only. The boiler produces hot
water by passing water over electric heating elements housed in an
insulated copper heat exchanger.
There are four boilers in the range with outputs ranging from 6kW
(20.472 Btu/hr) to 12kW (41.000 Btu/hr).
Important Safety Notes
Read these instructions before installing your boiler.
The heating system must comply with the latest editions of British
Standards 5449 and The Building Regulations and Electrical Wiring
Regulations BS 7671.
1. Always switch OFF the electrical supply before removing
the cover.
2. If any part of the boiler is modified, then the
guarantee/warranty will be invalidated.
We recommend that you keep these instructions in a place near
your appliance for easy reference.
The Trianco Aztec system wall mounted boiler has been designed
to conform to European Directive/Standards EN60335-
1:1994/A16:2001, EN60335-2-35:1998/A1:2000, EN55014 –1:2000,
EN55014-2:1997, EN61000-3-2:2000 and EN61000-3-3:1995.
THE PERSON(s) WHO INSTALLS THIS APPLIANCE, SERVICES OR
CARRIES OUT ANY REMEDIAL WORK, I.E. ELECTRICAL FAULT
FINDING, MUST HAVE SUITABLE ENGINEERING QUALIFICATIONS.
WARNING: DO NOT SWITCH ON THIS APPLIANCE IF THERE IS ANY
POSSIBILITY THAT THE WATER MAY BE FROZEN.
THE INSTALLATION OF THIS APPLIANCE MUST MEET THE
REQUIREMENTS OF THE CURRENT ISSUE FOR ELECTRICAL
INSTALLATIONS, IEE WIRING REGULATIONS.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS
(INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR
MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND
KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR
INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON
RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE
SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE
APPLIANCE.
5. User Instructions
The Trianco Aztec system boiler has been designed and constructed
to give years of trouble free service and these instructions are
provided to assist you in obtaining the best performance with the
least trouble and cost.
The boiler is fully automatic in operation and requires little attention
other than the setting of the thermostat and any external system
controls such as a room thermostat and time switch.
IMPORTANT
DO NOT COVER OR BOX IN YOUR BOILER, ALLOW AIR TO
CIRCULATE FREELY AROUND THE APPLIANCE.
WARNING: DO NOT ATTEMPT TO SWITCH ON THE BOILER IF THERE
IS ANY POSSIBILITY THAT THE WATER HEAT EXCHANGER IS
FROZEN.
Before firing the boiler, ensure the system is full of water and any
valves fitted on the system are open.
Check that the time switch/programmer (if fitted) is ON and the
room thermostat is calling for heat.
Set the boiler temperature to required temperature using the
control buttons.
Switch on the electrical supply to the boiler and after a few seconds
the boiler’s green and amber light should illuminate. Set the time
switch/programmer (f fitted) to the fitness and programs required.
The boiler will now operate automatically, cutting in and out
according to heat demand.
To Turn Off the Boiler
Switch off the boiler at the time switch/programmer (if fitted).
If the boiler is to be switched off for any length of time it is
recommended that the mains supply to the boiler is switched OFF.
Boiler Control Thermostat
The boiler control thermostat enables you to select the temperature
of the water leaving the boiler. It is calibrated between 35°C and
75°C.
Using a small screw driver set the temperature by turning the knob
to the required setting. The thermostat switches between low and
high (35°C and 75°C in 5°C increments).