manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Triangle Engineering of Arkansas
  6. •
  7. Fan
  8. •
  9. Triangle Engineering of Arkansas Heat BUSTER CMB Series User manual

Triangle Engineering of Arkansas Heat BUSTER CMB Series User manual

TM
Triangle engineering
of arkansas, inc.
E-mail: [email protected] • Website: www.trianglefans.com
1101 North Redmond Road Jacksonville, Arkansas 72076
(501) 982-7558 Fax (501) 982-5691 1-800-255-9014


SPL SERIES
CMB SERIES

Please complete for future reference.
Model #
_______________________
Serial #
______________
Purchased from
______________________________________
Date Purchased
_____________________________________
October 2016
OWNER’S
MANUAL
Read and
save these
instructions

The HEAT BUSTER is a high volume fan
designed for heavy-duty use in factories, ware-
houses, laundries, garages, etc. The unit is
constructed of cold-rolled steel with a powder
coat finish. Guards are made of steel wire and
comply with OSHA guarding requirements.

1. Your HEAT BUSTER fan will operate only on
115 Volt AC, 60Hz (cycle) current with a mini-
mum of a 15 Amp circuit.
2.  To reduce the risk of elec-
tric shock,   expose to water or
rain. To guard against electric shock while the
fan is connected to power source,  
 fan to come in contact with other
grounded objects such as pipes, radiators,
ranges, etc.
   
 pull on cord to remove from electrical
receptacle. Keep cord away from heat, oil and
sharp edges. Inspect cord periodically and
replace if damaged.
4. Disconnect the fan when not in use, before
servicing and cleaning and when repairing or
replacing parts.
5.  carry or move the fan when con-
nected to power source.
6. When the HEAT BUSTER is used out-of-
doors with extension cord, use only cord of
proper size (Amp rating), UL listed and with
receptacle to accept three prong grounded plug
furnished on the fans power cord. Only round
jacketed extension cords should be used.
7. Before operating this fan, check for worn
or damaged parts and replace or repair as
required. To avoid risk of fire, electrical shock
or other injury, disconnect from power source
before servicing.
   operate the HEAT BUSTER near
flammable liquids or in gaseous or explosive
atmospheres as sparks from motor may ignite
fumes.
9. If the wire guards are removed, replace
before normal operation.

No assembly required

Simply locate fan in desired position, connect
power cord, and fan is ready for operation.
IMPORTANT:
READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
TO INSTALL, OPERATE OR SERVICE THIS FAN. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY
DAMAGE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

1. Defective motor
2. No power
Fan does not operate 1. Replace motor
2. Check to see if power cord
is plugged in. Check fuse or
circuit breaker.
 
1. Loose pulleys or fan blade
2. Intake guard or exhaust
guard excessively dirty
1. Tighten pulley set screw
2. Clean guards
Insufficient air flow
1. Replace motor
2. Replace bearings and seals
3. Move motor to tighten belt
1. Defective motor bearings
2. Defective fan bearings
3. Worn belt
Squealing, slapping or whining
noises while operating

1. Motor bearings are pre-lubricated ball
bearings. Re-lubrication is not required.
2. Keep guards and blade clean by
vacuuming or wiping periodically. Also
keep motor from accumulating excessive
dust that may cause overheating.

1. Disconnect cord from power supply.
2. Remove guard screws.
3. Remove Guard.
NOTE: Upon completion of maintenance,
reinstall components in reverse order as
indicated above.

always give the following information:
1. Part description
2. Model Number of fan
3. Serial number









Specifications subject to change without notice.
Triangle Engineering of Arkansas, Inc. (Manufacturer) warrants, from the date
of purchase, to the original purchaser only, that the product manufactured by
Manufacturer is free from defects in material and workmanship for a period of
ONE (1) YEAR. Motors, capacitors, v-belts and switches are excluded from this
warranty, but shall have a limited one year warranty from date of purchase to
the original purchaser.
If a failure of the product occurs, contact the Manufacturer at:
1-800-255-9014
and give the model number of the product, the purchase date, and a descrip-
tion of the problem to the customer service agent.
Once the problem is diagnosed, and proof of purchase date is verified,
Manufacturer will have the option of shipping the necessary repair part(s) to the
Customer, freight prepaid or having the product returned to Manufacturer for
repair or replacement. If the product is returned to the Manufacturer, Customer
is responsible for prepayment of all inbound freight charges. Upon repair or
replacement, which shall be at the discretion of Manufacturer, the Manufacturer
will prepay all outbound freight charges for the return of the product to the
customer. However, if Manufacturer finds product to be in operating condition
and no problems are diagnosed, product will be returned to customer freight
collect.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION
ON THE FACE HEREOF.
Except as provided by this express warranty, the goods are sold “as is” without
any implied warranties.
This limited warranty does not cover labor to replace warrantied parts or
motors, nor does it cover damage resulting from accident, misuse or abuse,
lack of proper maintenance, improper installation, affixing of any parts or attach-
ments not authorized by Manufacturer, or loss of parts.
In no event shall Manufacturer be liable for any special, incidental, or consequen-
tial damages; which may result from any defect in material or workmanship.
It is expressly understood that Buyer’s sole and exclusive remedy shall be
repair or replacement of defective parts, and that Triangle Engineering shall not
be liable for injury to persons or property. Should the goods prove so defec-
tive, however, as to preclude the remedying of warranted defects by repair or
replacement, the Buyer’s sole and exclusive remedy shall then be a refund of the
purchase price.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
MOTOR REPLACEMENT DURING WARRANTY PERIOD
If the motor should fail during the first year of operation,
simply remove the LABEL ONLY from the motor and mail
the original label and copy of purchase receipt to Triangle
Engineering. Once the label is received, and if the motor is
still under warranty, we will ship a new motor within 24 hours,
UPS PREPAID. DO NOT RETURN MOTOR.

This manual suits for next models

7

Other Triangle Engineering of Arkansas Fan manuals

Triangle Engineering of Arkansas PC 3021 Direct Drive Portable Coolers User manual

Triangle Engineering of Arkansas

Triangle Engineering of Arkansas PC 3021 Direct Drive Portable Coolers User manual

Triangle Engineering of Arkansas Heat Buster SEB Series User manual

Triangle Engineering of Arkansas

Triangle Engineering of Arkansas Heat Buster SEB Series User manual

Triangle Engineering of Arkansas Master Breeze AMB2421 User manual

Triangle Engineering of Arkansas

Triangle Engineering of Arkansas Master Breeze AMB2421 User manual

Popular Fan manuals by other brands

Westinghouse 7220500 owner's manual

Westinghouse

Westinghouse 7220500 owner's manual

Parrot Uncle F6293110V Installation & operating instructions

Parrot Uncle

Parrot Uncle F6293110V Installation & operating instructions

Ebmpapst W4S250-DI02-01 operating instructions

Ebmpapst

Ebmpapst W4S250-DI02-01 operating instructions

Ebmpapst W3G650-CK07-13 operating instructions

Ebmpapst

Ebmpapst W3G650-CK07-13 operating instructions

Ebmpapst 4606 ZH operating manual

Ebmpapst

Ebmpapst 4606 ZH operating manual

Team Kalorik TKG VT 1037 C instructions

Team Kalorik

Team Kalorik TKG VT 1037 C instructions

Beper 70.239A Additional safety and use instructions

Beper

Beper 70.239A Additional safety and use instructions

Craftmade CS52 Specifications

Craftmade

Craftmade CS52 Specifications

VES Short Case Axial series Installation, operation & maintenance manual

VES

VES Short Case Axial series Installation, operation & maintenance manual

Fanco ORIGIN CFFCOR4KO installation manual

Fanco

Fanco ORIGIN CFFCOR4KO installation manual

emerio TFN-114529 instruction manual

emerio

emerio TFN-114529 instruction manual

Craftmade PAT64ABZC5 installation guide

Craftmade

Craftmade PAT64ABZC5 installation guide

Helios HelioVent HVR 150 Series Installation and operating instructions

Helios

Helios HelioVent HVR 150 Series Installation and operating instructions

emerio FN-214468.1 instruction manual

emerio

emerio FN-214468.1 instruction manual

Ruck Ventilatoren EM 100L EC 02 Assembly instruction

Ruck Ventilatoren

Ruck Ventilatoren EM 100L EC 02 Assembly instruction

Valor H3 Series installation manual

Valor

Valor H3 Series installation manual

Hunter FSQQ owner's guide

Hunter

Hunter FSQQ owner's guide

Ozeri OZF5 user manual

Ozeri

Ozeri OZF5 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.