Triangle Engineering of Arkansas PC 3021 Direct Drive Portable Coolers User manual

TM
Triangle engineering
of arkansas, inc.
E-mail: [email protected] • Website: www.trianglefans.com
1101 North Redmond Road •Jacksonville, Arkansas 72076
(501) 982-7558 •Fax (501) 982-5691 •1-800-255-9014
OWNER'S RECORD
Please complete for future reference.
Model #
_______________________
Serial #
______________
Purchased from
______________________________________
Date Purchased
_____________________________________
October 2016
■Installation
■Operation
OWNER’S
MANUAL
Read and
save these
instructions
DIRECT DRIVE
TM
PC 3021 Direct Drive

IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE OR SERVICE THIS FAN.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
The PORTABLE COOLER is a direct drive
fan designed for medium duty use in machine
and auto repair shops, factory work stations,
patios and decks, in laundries and dry clean-
ers, and anywhere air movement is required.
It is easily rolled to various locations on sturdy
7 " diameter wheels. The unit is constructed
of cold rolled steel with a painted finish.
Guards are made of steel wire and comply
with OSHA guarding requirements. The ON/
OFF switch is conveniently mounted on side
of barrel.
GENERAL SAFETY INFORMATION:
1. Your Portable Cooler will operate only on
110 Volt AC, 60 HZ (cycle) current with a
minimum of a 15 Amp circuit.
2. WARNING: To reduce the risk of electric
shock, DO NOT expose to water or rain.
To guard against electric shock while
the fan is connected to power source,
DO NOT PERMIT fan to become in con-
tact with other grounded objects such as
pipes, radiators, ranges, etc.
3. DO NOT ABUSE POWER CORD. DO
NOT pull on cord to remove from electrical
receptacle. Keep cord away from heat, oil
and sharp edges. Inspect cord periodically,
replacing if damaged.
4 Disconnect the fan when not in use, before
servicing and cleaning, and when repair-
ing or replacing parts.
5. DO NOT carry or move
the fan when connected
to power source. Be sure
switch is "OFF" prior
to connecting to power
source.
6. When the Portable
Cooler is used outdoors
with extension cord, use
cord of proper size (Amp
rating) only, UL listed and
with receptacle to accept
3-prong grounded plug
furnished on the fans
power cord. Only round
jacketed extension cords
Motor
should be used.
7. Before operating this fan, check for worn
or damaged parts and replace or repair
if required. To avoid risk of fire, electri-
cal shock or other injury, disconnect from
power source before servicing.
8. DO NOT operate the Portable Cooler near
flammable liquids or in gaseous or explo-
sive atmospheres as sparks from motor
may ignite fumes.
9. If the wire guards are removed, replace
before normal operation.
10. In case of power failure, turn off the fan
at switch. This will prevent motor burn out
and/or unexpected restarting.
WARNING:
TO REDUCE THE RISK OF FIRE OR
ELECTRICAL SHOCK DO NOT USE
THIS FAN WITH ANY SOLID STATE
FAN SPEED CONTROL DEVICE.
OPERATION: Your Portable Cooler is turned
ON or OFF with a rocker switch located toward
the top of the barrel. To operate the two speed
fan push one side of the rocker switch down
for low speed and the opposite side down for
high speed. Place the rocker switch in the
center position to turn the fan OFF.

IMPORTANT! Handle for model PC 3021 is
packed in the corner of the shipping carton.
Remove before discarding box.
Your “PC” is equipped with TWO (2) encapsu-
lated nuts, factory installed, inside the barrel of
the fan. To attach the handle to the barrel remove
the TWO hex head machine bolts from the pack-
age, insert them through the holes provided in
the handle, and screw them into the encapsu-
lated nuts. CAUTION: Do not over tighten. This
will cause the handle to collapse and the bolts to
become loose.
PRIOR to assembling handle to barrel, insert
handle bolts into encapsulated nuts in barrel.
With bolts inserted make certain they are 90° to
the holes in the handle. If required, bend bolts UP
or DOWN to align properly.
HANDLE ASSEMBLY
SYMPTOM
1. Faulty switch
2. Defective motor
3. No power
Fan does not operate 1. Replace switch
2. Repair or replace motor
3. Check to see if power cord is
plugged in. Check fuse or circuit
breaker
POSSIBLE CAUSE(S) CORRECTIVE ACTION
1. Intake guard or exhaust
guard excessively dirty
2. Contaminants have entered
the motor
1. Clean guards
2. Remove and clean or replace motor
Insufficient air flow
1. Replace motor
2. Replace fan blade
1. Defective motor bearings
2. Damaged blade
Squealing, slapping
or whining noises
while operating
TROUBLESHOOTING
WARNING!
Disconnect power before servicing
1. Motors are lubricated at the factory to operate
for long periods under normal conditions
without any re-lubrication.
2. Clean motor, guard and blade periodically,
preferably with a vacuum cleaner. Heavy
accumulations of dust and lint will result in
overheating and premature motor failure.
DISASSEMBLY PROCEDURE
1. Remove the screws that attach the wire guard
to the fan barrel on the motor side only.
2. Once the screws are removed, the guard, complete
with motor and fan blade, may be removed
from barrel. CAUTION: DO NOT PULL ON WIRE
WHICH CONNECTS MOTOR TO SWITCH.
WHEN ORDERING REPAIR PARTS
always give the following information:
1. Part description
2. Model Number of fan
3. Serial number
SERVICE and DISSASSEMBLY
Encapsulated
nuts
Proper
Alignment
Incorrect Alignment

LIMITED ONE YEAR WARRANTY
Specifications subject to change without notice.
Triangle Engineering of Arkansas, Inc. (Manufacturer) warrants, from the date
of purchase, to the original purchaser only, that the product manufactured by
Manufacturer is free from defects in material and workmanship for a period of
ONE (1) YEAR. Motors, capacitors, v-belts and switches are excluded from
this warranty, but shall have a limited one year warranty from date of purchase
to the original purchaser.
If a failure of the product occurs, contact the Manufacturer at:
1-800-255-9014
and give the model number of the product, the purchase date, and a descrip-
tion of the problem to the customer service agent.
Once the problem is diagnosed, and proof of purchase date is verified, Manufacturer
will have the option of shipping the necessary repair part(s) to the Customer, freight
prepaid or having the product returned to Manufacturer for repair or replacement. If
the product is returned to the Manufacturer, Customer is responsible for prepay-
ment of all inbound freight charges. Upon repair or replacement, which shall be at
the discretion of Manufacturer, the Manufacturer will prepay all outbound freight
charges for the return of the product to the customer. However, if Manufacturer
finds product to be in operating condition and no problems are diagnosed, product
will be returned to customer freight collect.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON
THE FACE HEREOF.
Except as provided by this express warranty, the goods are sold “as is” without
any implied warranties.
This limited warranty does not cover labor to replace warrantied parts or motors,
nor does it cover damage resulting from accident, misuse or abuse, lack of proper
maintenance, improper installation, affixing of any parts or attachments not autho-
rized by Manufacturer, or loss of parts.
In no event shall Manufacturer be liable for any special, incidental, or consequen-
tial damages; which may result from any defect in material or workmanship.
It is expressly understood that Buyer’s sole and exclusive remedy shall be repair or
replacement of defective parts, and that Triangle Engineering shall not be liable for
injury to persons or property. Should the goods prove so defective, however, as to
preclude the remedying of warranted defects by repair or replacement, the Buyer’s
sole and exclusive remedy shall then be a refund of the purchase price.
This warranty gives you specific legal rights, and you may also have other
rights which vary from state to state.
MOTOR REPLACEMENT DURING WARRANTY PERIOD
If the motor on your PORTABLE COOLER should fail during the
first year of operation, simply remove the LABEL ONLY from the
motor and mail the original label and copy of purchase receipt
to Triangle Engineering. Once the label is received, and if the
motor is still under warranty, we will ship a new motor within
24 hours, UPS PREPAID. DO NOT RETURN MOTOR.
Other Triangle Engineering of Arkansas Fan manuals
Popular Fan manuals by other brands

Feel-Maestro
Feel-Maestro MR901 owner's manual

Malmbergs
Malmbergs 99 930 08 instruction manual

Saturn
Saturn ST-FN8250 manual

Euramco Safety
Euramco Safety RAMFAN GX200 owner's manual

Fanimation
Fanimation Louvre FP1320 Series Specification sheet

Airflow
Airflow QuietAir QT 150B Installation and operating instructions