Triax DVB-S User manual

TRIAX - your ultimate connection
TRIAX - your ultimate connection
User guide
| GB |
891073D
DVB-S/S2 module - 492020

2
Contents
Contents
Disposal.................................................................................................................................. 3
Box content............................................................................................................................ 3
DVB-S module ....................................................................................................................... 3
Labels ..................................................................................................................................... 4
Cover removal........................................................................................................................ 4
Module installation................................................................................................................ 5
Module removal..................................................................................................................... 6
Input cable installation.......................................................................................................... 6
Status LED’s........................................................................................................................... 7
Log in...................................................................................................................................... 8
Input window ......................................................................................................................... 9
Configuration of input module .......................................................................................... 10
Status information.............................................................................................................. 14
Delete setup....................................................................................................................... 16
Save configuration .............................................................................................................. 17
Manufacturer ....................................................................................................................... 18
Your notes ............................................................................................................................ 19

3
Introduction
Disposal Within in the European Union this label indicates that the product
cannot be disposed of with the general household waste. Neither
the headend nor the input and output modules can be disposed
of with the general household waste.
For proper treatment and recycling of old products, please take
them to designated collection points in accordance with your na-
tional legislation.
The DVB-S module is one of the input modules that you can install in the in-
put section of your TDX headend unit.
DVB-S module
Box content
Below you can see an illustrated description of a DVB-S module.
A new input module is wrapped in antistatic bubble wrap and packed in a
cardboard box when you receive it.
Included in the box is a user guide instructing you in how to use the TDX
Service Tool to configure the module

4
Basics
Labels
Before you can install a DVB-S module in the input section you have to re-
move the cover that protects the module slot.
Cover removal
For EMC and cooling reasons only remove covers from the module slots that
you want to insert modules into.
You do not need tools to remove the covers, just use your fingers.
A label is placed on the input module where you can write the information re-
garding the configuration of the module.
Besides the information that you write on the label, the module type and part
number are also displayed on the label.
Note
On the bottom of the module you will find a label with the bar code and a se-
rial number printed on it.
The coloured part at the top of the label informs you of the mod-
ule type. Each type of module is allocated a unique coloured la-
bel.

5
Basics
Module instal-
lation
It is optional in which slots you place the individual input modules in the input
section. For convenience each slot has been given a number, and an over-
view of the slot numbers has been placed on the inside of the door of each
unit.
Note Slot no. 1 is placed in the top left-hand corner of the input section
when you face the front of the unit.
You install an input module by sliding the module into a module slot in the in-
put section of the headend unit and push it till the module clicks into place.
Note You can use hot swapping when you insert an input module into
or remove an input module from the TDX system.

6
When all the required input modules have been installed you can connect the
input signal cables one by one to the input modules.
It is also possible to make a loop through from one input module to another.
Input cable
installation
Basics
It is possible to remove an input module from a module slot without using
any tools, just use your fingers to press the fastener downwards and then
pull the module outwards to remove it from the module slot..
Module
removal

7
Basics
Status LED’s There is a status LED on the front of each module. The LED indicates wheth-
er the module has locked on to a frequency or needs to be configured.
When you update the software of a module the status LED provides you with
information about the updating process.
Boot loader state.
Orange
Initiation of the software update.
Temporary off
Every time the modules receives a valid data package.
Repeated until the update is completed without errors.
Temporary green
Software update failed.
Red
The module has not been configured yet.
Green - flashing
No errors and the module is locked to the frequency.
Green
Error and the module is not locked to the frequency.
Red
Power has not been switched on.
No colour

8
Log in
TDX Service Tool
When you have loaded the TDX Service Tool from the TDX headend system
to your laptop/computer the Login window of TDX Service Tool is displayed.
When you have pressed the Log in button the System window is displayed.

9
Input window
You have to configure the input modules individually.
TDX Service Tool
The first time you display the Input window in a new configuration the mod-
ule list only displays the number and type of input modules that you have
inserted in the main and subunits.
Click the Input tab in the TDX Service Tool to display the Input window.
To display the Configuration window, click the Setup button of the DVB-S in-
put module you want to configure.

10
TDX Service Tool
Configuration of
input module
The first time the TDX Service Tool displays the Configuration window for an
input module in a new configuration, the configuration fields and the list of
services will be empty or display default values.
Frequency Enter the desired frequency in MHz in this field.
Polarity To select the required polarity, click the arrow to the
right of the Polarity field to open the drop-down list
with the polarities you can choose from.
Select the polarity you want to use.
Symbol rate Enter the desired symbol rate in this field.
If you have connected a Digital Sequence Equipment Control (DiSEqC)
switch to the DVB-S module in question you have to select which satellite
position you want to use.
Note In connection with a loop through from one
DVB-S module to another DVB-S module, you
have to set the polarity of the second module
to “ 0V Off”.

11
TDX Service Tool
DiSEqC button Click the DiSEqC settings button to open the DiSEqC
settings window.
As default the DiSEqC switch is disabled.
In the DiSEqC settings window click the Enable DiS-
EqC version 1.0 radio button to access the DiSEqC
switch.

12
To select the required satellite position, click the ar-
row to the right of the Satellite position field to open
the drop-down list with the satellite positions you can
choose from.
Select the satellite position you want to use.
Click OK to return to the Configuration window.
TDX Service Tool
In case your DiSEqC switch does not support vertical
(13 volts) / horizontal (18 volts) polarisation and High
Band / Low Band frequencies, click the Use extended
position/polarity check box to enable up to 16 posi-
tions.

13
Click the Update button to enter the information into the headend system.
TDX Service Tool
As a result a list of available services is displayed in the services list area.

14
To select services you can either select all services in the service list area by
clicking the All button at the top of the list or select the services one by one
clicking the square to the right of the services you want to make available in
your TDX service pool.
Note By clicking one of those column headlines that are underlined in
the service list area you can sort the list into alphabetical or nu-
merical order depending on which column headline you click.
When you have selected the services you want, click the Submit button to
enter this information into the TDX system and return to the Input window.
Now the selected services are available in the TDX service pool.
TDX Service Tool

15
TDX Service Tool
When you display the Configuration window for an input module
that has been configured, all fields are filled in and services have
been selected.
If you want to change the existing frequency, polarity, services just
follow the same procedure as when you configure an input mod-
ule for the very first time.
Note
Status informa-
tion
Status information is placed at the bottom of the Configuration window. The
information displayed in the configuration window of a DVB-S module in-
cludes the status of the module, bit error rate, locked frequency, TS symbol
rate and revision of software.
Status Informs you whether the input module is locked or not.
Bit error rate Informs you of the rate at which errors occur in the
transmission.
Locked frequency Displays the actual frequency that the input module
has locked into.
Remember to click the Apply button in the upper right-hand corner to save
new settings in the configuration.
TS symbol rate Displays the actual symbol rate.
SW revision Displays the software version of the input module.

16
Now you can continue to configure the other input modules one by one, fol-
lowing the procedure described on the previous pages.
When you return to the Input window the configuration of the input module is
displayed in the module list.
TDX Service Tool
If you want to remove an input module and the associated configuration you
can use the Delete button of the module in question in the Input window.
Click the Delete button of the DVB-S input module you want to remove.
A message window is displayed asking you to confirm that you want to re-
move the input module.
Delete setup
Until you have removed the input module physically from the headend unit
the module list will display a line with the writing in red.

17
TDX Service Tool
Apply
Save configu-
ration
An important button when you change your configuration of the headend
system is the Apply button placed in the upper right-hand corner of the TDX
Service Tool window.
Whenever you have made changes in your configuration,
“Apply” on the Apply button turns red to tell you that you
have unsaved changes that need to be saved.
Click the Apply button to save the changes. When chang-
es have been saved the “Apply” text looses the red colour.

18
Manufacturer
Manufacturer Dear Customer,
Should you require technical assistance in the event that your expert dealer
is unable to help you, please contact us at:
Triax A/S
Bjørnkærvej 3
8783 Hornsyld
Denmark
Tel.: +45 76 82 22 00
www.triax.dk

19
Your notes
Your notes

TRIAX - your ultimate connection
TRIAX - your ultimate connection
891073D 01 - 2012
This manual suits for next models
2
Table of contents
Other Triax I/O System manuals
Popular I/O System manuals by other brands

Denkovi
Denkovi SmartDEN IP-32IN user manual

Honeywell
Honeywell GENT VIG-LPC-EN Application

Johnson Controls
Johnson Controls IOM4711 installation instructions

Motorola
Motorola MOSCAD-M RTU Hardware manual

National Instruments
National Instruments PCI-6251 user manual

National Instruments
National Instruments PCIe-7856R manual

TAC
TAC Xenta 421A Configuration Instruction

Argus Security
Argus Security TAURUS TW-MI-S-01 quick start guide

WAGO
WAGO I/O SYSTEM 750 750-833 manual

SeaLevel
SeaLevel ISO-16.PCI user manual

Tews Technologies
Tews Technologies TPMC851 user manual

Honeywell
Honeywell PEHA 940/24 EM RÜ o.T. Installation and operating instructions