manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tuma
  6. •
  7. Fan
  8. •
  9. Tuma BVN10A001 User manual

Tuma BVN10A001 User manual

DIMENSIONS
Unit:mm
ventilation fan / Wall Exhaust Fan
Model
BVN10A001
Voltage
(V)
100-240
Frequency
(Hz)
50-60
Air Flow
(m3/h)
100
Power
Consumption
(W)
1.7
Weight
(g)
630
Accessories : Screw (Ø4x27mm)-4 pcs
White plastic wall plugs (Ø7.5x25mm)-4 pcs
90
70
Ø99
Installation and Operating Instructions
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO.,LTD.
MODEL BVN10A001
200
200
GENERAL SAFETY INFORMATION
INSTALLATIONS-Wall
WALL
WALL
15cm
15cm
Ceiling
Side Wall
Mounting Hole
Ø105mm
White plastic wall plugs
Mounting hole
Connect wiring
Air vents of the machine
Figure 1
The "terminal" of the body should be facing upward.
Figure 2
Screw Figure 3
L
N
Double Pole
Switch
Terminal Block
Ventilation
Fan
INSTALLATIONS-Windows
Cleaning and maintenance
Attention
Vacuum cleaner
Cleaning Method (monthly cleaning is recommended)
Unit
WALL
WALL
Figure 4
Follow all local electrical and safety codes.
Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals or other objects.
These ventilating fans are intended for residential usage only.
Always disconnect the power source before working on or near the ventilating fan, motor or
junction box.
Installation should be completed by a qualified personnel.
Please assemble correctly to avoid abnormal sounds or resonance.
Installation using methods other than those specified in this manual are prohibited.
Do not install these ventilating fans on ceilings.
Do not install in areas accessible by flames.
Do not mount over heating sources such as cooking equipment (see Fig. A), or in places with
temperatures over 40℃.
100V - 240V Available.
For installation in humid environments (such as the bathroom), please install a leakage circuit breaker, and set the switch
outside the bathroom.
The bottom of the unit must be installed 2.3 meters or more above the ground.
No water pipes are allowed to pass through or above the product and 2 m around it.
In case of gas leakage, Do Not turn on this device.
This device shall not be operated or maintained by children or inexperienced individuals.
This product is to be used for normal ventilation only. Usage for ventilation of hazardous or explosive gases is prohibited.
This device must not be mounted in places with or near noxious or hazardous gases to prevent undesirable/hazardous gases
from flowing backwards into the room.
(for EU region) This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved.
(for EU region) Children shall not play with the appliance.
(for EU region) Cleaning and user maintenance shall not be made by children without supervision.
(for other than EU region) The appliance is not to be used by persons (including children) with reduced physical, sensory or
mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction.
(for other than EU region) Children being supervised not to play with the appliance.
Please use this appliance only at altitude of 2,000 meters below.
The installation hole cannot be opened on i-beams, pillars, or
bearing walls. This will endanger the building’s structure. It
must also avoid electric wires inside the wall.
The internal aperture surface is suggested to apply waterproof
resin coating (Waterproof sealer) after drilling the wall. Install
ventilation fan when the surface is fully dry and solid.
If a pre-installed PVC pipe is used as the installation hole, it is
necessary to ensure the full circumference of the PVC pipe is
bigger than 102mm after cement grouting.
The direction of drilling shall
be vertical to the wall.
2. Measure the depth of the mounting hole on the wall and install
the Air vents of the machine into it.
3. Based on the indication of arrows of Figure 1, mark the position
of the four screw holes on to the wall and then remove the body.
Drill a hole with a width of Ø6mm and a depth of 30mm or above
on to the marked positions, and fasten the white plastic wall
plugs (as shown in Figure 2).
4.Put the air vents of the machine into the plastic tube of the
mounted hole, let it lay flat against the wall, and use the
mounted screws within the accessory pack to install it onto the
plastic wall plugs (as shown in Figure 3).
1. Please choose: Glass installation of 3~4mm in width, and minimum area of 250×250mm or more.
2. Drill out a Ø105mm mounting hole in the glass.(as shown in Figure 5)
* Due to the different strengths of commercially available glass, it is recommended that the drilling be performed by professional
technicians. If the glass has slight cracks after drilling, do not continue the installation.
3.After applying foam glue to the body(as shown in Figure 6), fix it on to the force glass. Ensure the edge between the pipe and the
glass is sealed and airtight with silicon.(as shown in Figure 7)
4. Please follow the electrical wiring diagram of this manual in connecting to the power and test its operation for abnormal
vibrations and sounds. After checking, the panel can be fastened to the body and tightened along the four sides of the panel. (as
shown in Figure 8)
Please install this appliance on glass with eaves, please switch off this appliance to avoid product
damage when weather conditions are unfavorable, e.g. heavy wind, heavy rain or typhoons.
5. Please follow the electrical wiring diagram of this manual to
connect wires and test its operation to check for abnormal
vibration and sound. After confirmation, the panel can be
attached to the body and tightened along the four sides of the
panel (as shown in Figure 4).
6. Please confirm whether the product will be subjected to
direct wind and rain. If that is the case, a commercially available
4-inch rain cover is recommended to be installed at the pipe
outlet.
(1) Always disconnect the power source before working on or
cleaning the product!
(2) Do not use a gasoline, toluene, decontamination powder or
other chemicals to wipe the ventilation fan.
(3) To prevent deformation and discoloration, do not clean the
plastic components with liquid or detergent above 60 °C.
(4) To avoid malfunction or electric shocks, do not spray water
on electrical components such as the motor.
(5) Regular maintenance on an annually basis is recommended
to ensure the ventilation fan can still operate normally.
(6) To avoid danger, if the flexible wire is damaged, its replace-
ment should be conducted by professionals of the manufac-
turer, personnel from the manufacturers maintenance depart-
ment or other similar departments.
(1) First remove the outer cover, wash the outer cover with water,
then wipe it with a dry cloth or let it dry in a cool place.
(2) When the power has been disconnected, please use the
cleaning tool to remove dirt on the ventilation fan. (as shown in
Figure 9)
(3) Use a clean soft cloth and kitchen detergent to wipe dirt off
the ventilation fan, and reinstall the cover. (as shown in Figure
10)
Always disconnect the power source before
working on or cleaning the product!
(1) Please follow the electrical wiring in accordance with local
electrical codes.
(2) Install the power switch which outside the bathroom.
(3) Please follow the wiring diagram figure to connect all wiring
installation.
(4) The installation must be provided with a double pole isolator
switch having a contact separation of not less than 3 mm.
Cooking Equipment
Cooking area
Do not install above
or inside this area
45° 45°
1.Use a wall drill to open up a Ø105mm on the mounting hole
position;A distance of 15 cm or more is required from the edge of
the paper mold to the ceiling and each side of the wall.
Figure 5 Figure 6 Figure 7 Figure 8
Figure 9 Figure 10
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
泡棉膠
泡棉膠
泡棉膠

Other Tuma Fan manuals

Tuma Flow2one Plus+ User manual

Tuma

Tuma Flow2one Plus+ User manual

Tuma Flow2one Plus+ Product guide

Tuma

Tuma Flow2one Plus+ Product guide

Popular Fan manuals by other brands

Maico ECO 30 E Mounting and operating instructions

Maico

Maico ECO 30 E Mounting and operating instructions

Thermador CVS2 Series use and care manual

Thermador

Thermador CVS2 Series use and care manual

aerauliqa QR200A installation manual

aerauliqa

aerauliqa QR200A installation manual

WAC Lighting GEOS F-068L installation instructions

WAC Lighting

WAC Lighting GEOS F-068L installation instructions

NuTone QTXE080 instructions

NuTone

NuTone QTXE080 instructions

flowair UVO H EC Series Technical documentation operation manual

flowair

flowair UVO H EC Series Technical documentation operation manual

Merra CFN-1111 user manual

Merra

Merra CFN-1111 user manual

Amana MBVC Series manual

Amana

Amana MBVC Series manual

MOTINI FAN-CL-0002 Installation and safety instructions

MOTINI

MOTINI FAN-CL-0002 Installation and safety instructions

ProKlima FAN-111544.1 instruction manual

ProKlima

ProKlima FAN-111544.1 instruction manual

Hunter 23277 Installation and operation manual

Hunter

Hunter 23277 Installation and operation manual

Monte Carlo Fan Company 5PPR54 Series Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5PPR54 Series Owner's guide and installation manual

Somogyi Elektronic home TF 231 instruction manual

Somogyi Elektronic

Somogyi Elektronic home TF 231 instruction manual

Xpelair GX12 Installation and operating instructions

Xpelair

Xpelair GX12 Installation and operating instructions

Craftmade Nate NTE52 installation guide

Craftmade

Craftmade Nate NTE52 installation guide

Soleus Air FTY-30 user manual

Soleus Air

Soleus Air FTY-30 user manual

Bionaire BASF40 instruction manual

Bionaire

Bionaire BASF40 instruction manual

Prominence Home 51028 owner's manual

Prominence Home

Prominence Home 51028 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.