turck TX700FB User manual

Your Global Automation Partner
Instructions for Use
TX700FB
HMI/PLC Series for Food
and Beverage

2Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

V01.00 | 2020/11 3
Table of Contents
1 About These Instructions ................................................................................................................. 5
1.1 Target groups................................................................................................................... 5
1.2 Explanation of symbols used ........................................................................................ 5
1.3 Other documents ............................................................................................................ 5
1.4 Feedback about these instructions.............................................................................. 5
2 Notes on the Product......................................................................................................................... 6
2.1 Product identification..................................................................................................... 6
2.1.1 Type label............................................................................................................................................6
2.1.2 Type code ...........................................................................................................................................7
2.2 Scope of delivery ............................................................................................................. 7
2.3 Legal requirements.........................................................................................................7
2.4 Manufacturer and service.............................................................................................. 7
3 For Your Safety.................................................................................................................................... 9
3.1 Intended use..................................................................................................................... 9
3.2 General safety notes ....................................................................................................... 9
4 Product Description .........................................................................................................................10
4.1 Device overview ............................................................................................................10
4.2 Properties and features................................................................................................11
4.3 Functions and operating modes ................................................................................11
4.3.1 Interfaces...........................................................................................................................................12
4.4 Accessories .....................................................................................................................13
4.4.1 Plug-in extension modules.........................................................................................................13
4.4.2 Power supply...................................................................................................................................13
4.4.3 USB accessory..................................................................................................................................13
5 Installing.............................................................................................................................................14
5.1 Installation instructions ...............................................................................................14
5.2 Fasten devices in the mounting cutout ....................................................................15
5.3 Installing plug-in modules...........................................................................................16
5.4 Grounding the device...................................................................................................17
6 Connecting ........................................................................................................................................18
6.1 Connecting the power supply ....................................................................................18
6.2 Connecting the device to Ethernet............................................................................19
6.3 Connecting external devices to the serial interface ...............................................19
6.4 Connecting plug-in modules ......................................................................................20
6.4.1 Slot assignment – CAN port.......................................................................................................21
6.4.2 Slot assignment – serial interfaces ..........................................................................................21
7 Commissioning .................................................................................................................................22
7.1 Charging the battery ....................................................................................................22
7.2 Using the touchscreen..................................................................................................22
7.3 Initial commissioning ...................................................................................................22
7.4 Web server login............................................................................................................22
7.5 Setting the IP address...................................................................................................23
7.5.1 Setting the IP address via the web server.............................................................................23
7.5.2 Setting the IP address via Turck Service Tool ......................................................................24

Table of Contents
4Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7.6 Programming with CODESYS......................................................................................25
7.7 Programming with TX VisuPro ...................................................................................25
7.7.1 Transferring TX VisuPro to the device ....................................................................................26
8 Configuring........................................................................................................................................27
8.1 Configuring the system settings ................................................................................27
9 Operating ...........................................................................................................................................29
9.1 LED displays....................................................................................................................29
10 Troubleshooting ...............................................................................................................................30
11 Maintenance......................................................................................................................................31
12 Repair..................................................................................................................................................31
12.1 Returning devices..........................................................................................................31
13 Disposal ..............................................................................................................................................31
14 Technical Data...................................................................................................................................32
15 Appendix: Approvals and markings .............................................................................................35

V01.00 | 2020/11 5
1 About These Instructions
These operating instructions describe the structure, functions and the use of the product and
will help you to operate the product as intended. Read these instructions carefully before using
the product. This is to avoid possible damage to persons, property or the device. Retain the in-
structions for future use during the service life of the product. If the product is passed on, pass
on these instructions as well.
1.1 Target groups
These instructions are aimed at qualified personal and must be carefully read by anyone
mounting, commissioning, operating, maintaining, dismantling or disposing of the device.
1.2 Explanation of symbols used
The following symbols are used in these instructions:
DANGER
DANGER indicates a dangerous situation with high risk of death or severe injury if
not avoided.
WARNING
WARNING indicates a dangerous situation with medium risk of death or severe in-
jury if not avoided.
CAUTION
CAUTION indicates a dangerous situation of medium risk which may result in minor
or moderate injury if not avoided.
NOTICE
NOTICE indicates a situation which may lead to property damage if not avoided.
NOTE
NOTE indicates tips, recommendations and useful information on specific actions
and facts. The notes simplify your work and help you to avoid additional work.
uCALL TO ACTION
This symbol denotes actions that the user must carry out.
aRESULTS OF ACTION
This symbol denotes relevant results of actions.
1.3 Other documents
The following additional documents are available online at www.turck.com
nData sheet
nQuick Start Guide
1.4 Feedback about these instructions
We make every effort to ensure that these instructions are as informative and as clear as pos-
sible. If you have any suggestions for improving the design or if some information is missing in
the document, please send your suggestions to [email protected].

Note on the Product
Product identification
6Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
2 Notes on the Product
2.1 Product identification
These instructions apply to the following HMIs:
nTX707FB-P3CV01
nTX715FB-P3CV01
2.1.1 Type label
The Type label is located on the back of the device.
Fig.1: Type label TX707FB (example)
Type designation TX707FB-…
Ident no. 100007471
Year/week of production A2048
Serial number (S.N.) AA…
Internal version ID of the product (V) 121…

V01.00 | 2020/11 7
2.1.2 Type code
TX 7 05 FB –P3 CV 01
TX Product series
Product series
TX Turck HMI/PLC
7Series
Serie
7TX700 series
05 Screen diagonal
Size
00 Without display
05 5”
07 7”
10 10.1”
15 15.6”
21 21.5”
FB Variant –
Variant
Blank Standard
FB Food & Beverage
HB High Brightness
SSingle Core
DDual Qore
QQuad Core
P3 PLC
PLC
P3 CODESYS V3 PLC Runtime
CV Visualization
Visualization
CV CODEYS V3 TargetVisu Runtime
WV WebVisu (CODESYS, TX VisuPro)
01 Communication
Communication
01 PROFINET controller
EtherNet/IP scanner
Modbus TCP master/slave
Modbus RTU master/slave
CANopen master
Fig.2: Type code TX700
2.2 Scope of delivery
nTX700
n Food compliant gasket
nPower supply connector
nConnector for serial interface
nMounting brackets
nQuick Start Guide
2.3 Legal requirements
The device is subject to the following EC directives:
n2014/30/EU (electromagnetic compatibility)
n2011/65/EU (RoHS Directive)
2.4 Manufacturer and service
Hans Turck GmbH & Co. KG
Witzlebenstraße 7
45472 Mülheim an der Ruhr
Germany
Turck supports you with your projects, from initial analysis to the commissioning of your applic-
ation. The Turck product database contains software tools for programming, configuration or
commissioning, data sheets and CAD files in numerous export formats. You can access the
product database at the following address: www.turck.de/products

Note on the Product
Manufacturer and service
8Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
For further inquiries in Germany contact the Sales and Service Team on:
nSales: +49 208 4952-380
nTechnology: +49 208 4952-390
Outside Germany, please contact your local Turck representative.

V01.00 | 2020/11 9
3 For Your Safety
The product is designed according to state-of-the-art technology. However, residual risks still
exist. Observe the following warnings and safety notices to prevent damage to persons and
property. Turck accepts no liability for damage caused by failure to observe these warning and
safety notices.
3.1 Intended use
These devices are designed solely for use in industrial areas.
The HMIs (Human Machine Interfaces) of the TX700 family are used to control, operate and
monitor machine processes. The HMI/PLC operator panels of the F&B series are suitable for use
in the F&B industry and comply with the standards and guidelines for hygienic design DIN
EN1672-2 and EHEDG/FDA 21 CFR 177.2006.
The devices may only be used as described in these instructions. Any other use is not in accord-
ance with the intended use. Turck accepts no liability for any resulting damage.
3.2 General safety notes
nThe device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
nThe device may only be used in accordance with applicable national and international regu-
lations, standards and laws.
nThe device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.

Product Description
Device overview
10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4 Product Description
The front of the device is designed in protection class IP69K, the rear of the housing in IP20.
Three Ethernet ports are available for the connection to Ethernet.
The serial port is used to communicate with a PLC or with field devices with RS232 or RS485 in-
terface. Plug-in modules with different functions (digital and analog I/Os, CAN master,
PROFIBUS-DP slave, RS232 and RS485 interface, UMTS modem, etc.) can be connected via the
extension slots. A USB host port and an SD card slot are provided for using external storage me-
dia.
The TFT widescreen color display of the devices is designed as a capacitive multi-touch touch
screen. The HMI/PLC operator panels of the F&B series have been specified and developed ac-
cording to the standards and guidelines for hygienic design DIN EN1672-2 and EHEDG/FDA 21
CFR 177.2006. The glass front has a food grade polyester coating. The frame is made of stainless
steel.
Device variants:
nTX707FB: 7” HMI, CODESYS V3 PLC, WebVisu, dual core A9, 800MHz, 3 Ethernet ports, 4GB
Flash, 1GB RAM
nTX715FB: 15.6” HMI, CODESYS V3 PLC, WebVisu quad core A9, 800MHz, 3 Ethernet ports,
8GB Flash, 2GB RAM
4.1 Device overview
Fig.3: Dimensions – TX707FB

V01.00 | 2020/11 11
Fig.4: Dimensions – TX715FB
4.2 Properties and features
nGateway function with OPC UA Server and Client (with TX VisuPro)
nSafe connection to Turck Cloud with complete network isolation
nMQTT for connecting all common cloud systems (with TX VisuPro)
nCODESYS V3 PLC runtime with selection of the most important I/O protocols
nCODESYS V3 WebVisu or TX VisuPro WebVisu
nOptional extension modules for I/Os and further communication interfaces
4.3 Functions and operating modes
The CODESYS V3 control of the devices has the functions PROFINET controller, EtherNet/IP
scanner and Modbus TCP as well as Modbus RTU master. Additionally the TX700 HMIs can be
used as Modbus TCP as well as Modbus RTU slave.
The devices combine all functions of a PLC with the functions and interfaces of the TX VisuPro
software.
Additional functions
nEthernet TCP/IP or UDP/IP communication
nOPC UA server (with CODESYS or TX VisuPro)
nOPC UA client and MQTT (with TX VisuPro)
nSerial communication via RS232, RS485 and RS422

Product Description
Functions and operating modes
12 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4.3.1 Interfaces
The device has the following interfaces:
nEthernet ports
– 2 × 10/100 Mbit, 1 × 10/100/1000 Mbit
nExtension slots for plug-in modules
– 2 slots for max. 4 plug-in modules
nSerial interface
nSlot for SD card
nUSB port
Compatible SD cards
Specification
Supported types SD, SDHC
Format FAT, FAT32
Max. size Limited by FAT32 specifications
≤ 4 GB for a single file
≤ 32 GB
Compatible USB devices
Specification
Format FAT, FAT32
Max. size Limited by FAT32 specifications
≤ 4 GB for a single file
≤ 32 GB

V01.00 | 2020/11 13
4.4 Accessories
4.4.1 Plug-in extension modules
Ident no. Type Description
6828210 TX-CAN CAN interface
6828203 TX-IO-DX06 n8 digital inputs, 24 VDC, pnp
n6 digital outputs, 24 VDC, 0.5 A, pnp
n1 × relay output, NO
6828201 TX-IO-XX03 n20 digital inputs, 24 VDC, pnp
n12 digital outputs, 24 VDC, 0.5 A, pnp
n8 × analog inputs, U, I, RTD, TC
n4 × analog outputs, U, I
100002598 TX-RS485 Serial interface for RS485/RS422 communica-
tion
100002599 TX-RS232 Serial interface for RS232 communication
100004786 TX-EXTEND Bus extension, electromechanical adapter for
the use of the plug-in module TX-IO-XX03
100009535 TX-UMTS Wireless modem plug-in (2G, 3G)
100010167 TX-DP-S PROFIBUS-DP slave, 12 Mbaud
4.4.2 Power supply
Ident No. Type Description
100002938 TX-PSC TX power supply onnector
4.4.3 USB accessory
Ident No. Type Description
6827389 USB 2.0 EXTENSION 5M USB 2.0 extension cable, male (A) to female (A),
5m
6827390 USB 2.0 EXTENSION ACTIVE 5M USB 2.0 extension cable, male (A) to female (A),
with active repeater, 5m
NOTE
You will find further accessory products under www.turck.com.

Installing
Installation instructions
14 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5 Installing
The devices are inserted into a flat mounting plate with a corresponding installation cut-out.
NOTE
The technical data in the appendix of these operating instructions contain informa-
tion on the size of the required installation cut-out.
Fig.5: TX700 – mounting
5.1 Installation instructions
nDo not cover the ventilation slots in the device.
nDo not expose the device to direct sunlight for long periods of time to avoid overheating the
device.
nDo not install the device in environments in which it is exposed to corrosive chemical sub-
stances.
In order to meet the protection class IP66, the following installation procedure must be ob-
served:
nThe device is suitable for mounting on surfaces with a thickness of 1.5 mm to 6 mm.
nThe maximum surface roughness of the mounting surface is 120 µm.
nThe cut-out for the HMI must correspond to the specified dimensions, see "Technical Data”.
nThe borders of the cutout must be flat.
nThe minimum tightening torque for the fixing screws of the mounting brackets is 130 Ncm.
The mounting brackets must rest firmly on the device.

V01.00 | 2020/11 15
5.2 Fasten devices in the mounting cutout
The devices are fixed in the mounting cutout with mounting brackets.
Mount the brackets as follows.
Fig.6: Insert the brackets
Tighten the fastening screws until the brackets are firmly in contact with the device. The
minimum tightening torque to guarantee protection class IP66 is 130 Ncm.

Installing
Installing plug-in modules
16 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
5.3 Installing plug-in modules
Fig.7: Installing plug-in modules
(e. g. TX-CAN, TX-IO-DX06)
Fig.8: Installing plug-in modules
(e. g. TX-IO-XX03)

V01.00 | 2020/11 17
5.4 Grounding the device
Connect terminal 3 of the supply connector to the ground terminal.
General instructions for device grounding
All the electronic devices in the control system must be properly grounded.
Carry out grounding according to the applicable regulations.
Ground the device to minimize noise effects from electromagnetic interference.
Ground the unit via the grounding screw near the power supply connection.
Grounding the power supply
The power supply circuit may be floating or grounded.
To ground the supply circuit, connect the ground wire to the protective earth as shown
in the following figure (dotted line).
If the supply circuit is not grounded, the unit itself is internally connected to ground
(1MΩ resistor with 4.7nF capacitor connected in parallel).
The power supply must have double or reinforced insulation.
Fig.9: Power supply – wiring

Connecting
Connecting the power supply
18 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
6 Connecting
NOTE
All connections are SELV connections.
Provide transient protection at the supply terminals set to a maximum of 140 % of the
peak value of the rated voltage.
Ensure that the power supply is of sufficient capacity to operate the device.
Fig.10: TX7 … FB – connectors
Port Description
1 USB port, V2.0, max. 500 mA
2 Ethernet port 2 (10/100 Mbit)
3 Ethernet port 1 (10/100 Mbit)
4 Serial interface
5 Ethernet port 0 (10/100/1000 Mbit)
6 Power supply
7 2 extension slots for plug-in modules
8 SD card slot
6.1 Connecting the power supply
Connect the device to the voltage supply according to the following figure.
Fig.11: Power connectorTX7…
NOTE
The power connector is part of the scope of delivery and can be ordered as spare
part [}13].

V01.00 | 2020/11 19
6.2 Connecting the device to Ethernet
The device has two RJ45 Fast Ethernet sockets and one RJ45 Gigabit Ethernet socket for con-
nection to Ethernet.
Connect the device to Ethernet using a standard Ethernet cable. Use a Gigabit-capable
Ethernet cable to connect the devices to a Gigabit network.
Default settings of the Ethernet ports
The Ethernet ports are set to DHCP at delivery.
6.3 Connecting external devices to the serial interface
The serial port is used to communicate with a PLC or with another type of device. The following
standards are available at the serial interface: The type of serial interface is determined in the
programming software. The connection cable must be selected to match the device to be con-
nected.
nRS232
nRS422
nRS485
Fig.12: Serial interface
Pin RS232 RS482/422
1 RxD CHB-
2 TxD CHA-
3 CTS CHB+
4 RTS CHA+
5 +5 VDC output +5 VDC output
6 GND GND
7 n. c. n. c.
8 Shield Shield
NOTE
To operate in RS485, pins 1 and 2 as well as pins 3 and 4 must be connected extern-
ally.

Connecting
Connecting plug-in modules
20 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
6.4 Connecting plug-in modules
The TX700 HMIs allow the use of several optional in modules. Several module configurations
are possible.
Fig.13: Slots for plug-in modules
Slot2 and slot4 are available only if the plug-in module has bus extension connector.
Each slot has three communication channels:
n1 serial interface
n1 CAN interface
n1 SPI interface
NOTE
It is not possible to stack two modules that are using the same type of interface.
The following table shows, which plug-in module and how many plug-in modules can be used
at which device:
Module Application Max. number of modules Interface type/
communication
interface
Bus extension
connector
TX-CAN CAN n1 for TX705
n2 for TX707… TX721
CAN Yes
TX-RS485 RS485/RS422 Serial Yes
TX-RS232 RS232 Serial Yes
TX-IO-DX06 Compact I/O SPI No
TX-IO-XX03 Multifunction I/O 1
TX705: TX-EXTEND or other
extension module with ex-
tension slot necessary
SPI No
This manual suits for next models
2
Table of contents
Other turck Monitor manuals