Tyco Electronics FIST-WR2 User manual

FIST-WR2
INSTALLATION INSTRUCTION
FIST wall mountable rack
1 Introduction
2 General
2.1 Kit content
2.2 Tools
3 Unpacking instructions
4 Mounting the WR2
onto the wall
5 Preparing the rack for cable termination
and shelf mounting
5.1 Position of shelfs in the rack(ETSI,19”..)
5.2 Changing the CAP position
6 Cable termination in rack
7 Preparing cable
8 Pigtails
Contents
1 Introduction
The FIST Wall Mountable Rack, FIST-WR2, is an all-purpose metal indoor rack designed to accommodate the
FIST generic shelf family (ETSI and 19”).
It offers dust-proof, environmental and mechanical protection for the fiber management functions of splicing,
patching and passive component integration.
FIST-WR2 is designed for indoor applications and is designed to attach to a wall. A separate wall attachment
frame is included in the kit and allows hanging up the rack in a user-friendly way.
To clean FIST components, the use of isopropylalcohol is recommended.

2
2 General
2.1 Kit content
3.2.1 Open the WR using the key.
3.2 Removing the wall attachment frame
• 2 front doors with swing handle and lock with key
• Mounting profiles: field adaptive to 19” or ETSI width
• In top and bottom, left and right 3 plates with the break-outs listed
underneath (in total 12 cable entry plates with break-out ports):
- 6 plates with 2xPG29 break-out ports (top)
- 3 plates with 4xPG21 break-out ports
- 3 plates with 6xPG16 break-out ports
All plates have identical outer dimensions and fit in each top
and bottom cut-out.
- 1 cable attachment plate with C-profile (no cable clamps)
- 1 wall attachment kit (including installation flyer)
- Document holder in the door.
2.2 Tools
FACC-ALLEN-KEY-5-350 1 pc Allen key, diameter 5 mm,
length 350 mm for back
mounting of shelves in rack
FACC-CAGE-NUT-TOOL 1 pc For installation of cage nuts
in the rack
3 Unpacking instructions
3.1 Open the back of the package. All labels are on the front side.
Remove the FIST-WR2 from it.
3.2.2 Remove the wall attachment frame by removing the two
bottom bolts (B) completely and releasing the two top bolts (A) partly.
(4 turns clockwise)

3
4.1 Place the wall attachment frame against the wall and mark the
holes on the wall. Drill the 6 holes and place the plugs. Fasten the wall
attachment frame on the wall.
4 Mounting the FIST-WR2 onto the wall
4.2 Hook the rack on the wall attachment frame.
5 Preparing the rack for cable termination
and shelf mounting
5.1 According to the size of the shelves and the lay-out of the rack
one should mount the uprights in the correct position by removing the
5 nuts.
4.3 Tighten the bolts inside the rack to secure the rack on the wall
attachment frame,

4
6.3 Select a plate with the knock out ports according to the glands
to be used. If needed, the plates can be changed or moved by
unscrewing the 4 screws. Open the knock out ports, using a hammer
and screwdriver and install the selected gland.
7 Cable preparation and fixation (loose tube,
IFC and breakout cable)
7.1 Open the gland and adjust the rubber according to the cable
diameter. Pull 5 m of cable through the gland and rack. Remove the
cable jacket. Make sure having 3.5 m of fiber on the FIST- GSS2 and
2 m on the FIST-GPS2, measured at the side of the shelf (see
installation instruction of the network element).
5.2 The cable termination plate can be moved up or down and it
can be installed left in the rack, by removing the two nuts. A second
CAP can be installed on the pre-installed L-profile.
6 Cable termination in the rack
6.1 The cable can be led into and terminated on the cable
termination plate in the 4 corners of the rack. However, preference is
given to bottom right.
6.2 The first incoming cable should be installed at the back side of
the rack. The top shelf is the first shelf to install, this to make future
installations of more cables easier.

5
7.2 Cut the strength member on 75 mm. Fix the strength member
and cable.
7.3 Cut the flex tube to length and install.
7.5 FIST-GSS2 cable routing example 2 (shelf in top position).
7.4 FIST-GSS2 cable routing example 1 (shelf in bottom position).

6
7.6 Using two cable clamps on two cables.
7.7 One clamp can be used on two cables.

7
8.3 Take the wraparound pigtail seal and insert the pigtails or
jumpers one by one in the selected groove by turning the fixing ring.
8.2 Open the knock out ports using a hammer and screwdriver
and install the pigtail seal.
8 Pigtails
If pigtails have to leave a sealed rack, pigtail seals should be installed.
8.1 Select a plate with the knock out ports. If needed the plates
can be changed or moved by unscrewing the 4 screws.
7.8 In case of FIST-GR-CTB100-CC mounted

8.4 Wrap the rubber sealing ring around the installed pigtails and
slide the insert into the housing.
8.5 Wrap the locking ring around the housing and fasten the bolt
hand-tight by the use of an Allen key.
Tyco Electronics Raychem NV
Diestsesteenweg 692
B-3010 Kessel-Lo, Belgium
Tel.: 32-16-351 011
Fax: 32-16-351 697
www.tycoelectronics.com
www.telecomosp.com
TC 727/IP/2 01/08
Tyco Electronics, TE logo and FIST are trademarks.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is
believed to be reliable. However, Tyco Electronics makes no warranties as to its accuracy or completeness and disclaims any liability
in connection with its use. Tyco Electronics’ obligations shall only be as set forth in Tyco Electronics’ Standard Terms and Conditions
of Sale for this product and in no case will Tyco Electronics be liable for any incidental, indirect or consequential damages arising out
of the sale, resale, use or misuse of the product. Users of Tyco Electronics products should make their own evaluation to determine
the suitability of each such product for the specific application.