UFH Komfort Touch+ User manual

Function and Display Icons
Constant = Manual Control ON
Flashing = Temporary Manual Control ON
Not displayed = Automatic Control ON
Heating On
Frost Protection On
1
st
Program Event
nd
Program Event
3
rd
Program Event
4
th
Program Event
5
th
Program Event
6
th
Program Event
Constant = Locked Not displayed = Unlocked
Press 7 seconds to lock / Press 7 seconds to unlock
Features
Glacier White Sapphire Black
Large LCD screen with blue backlight display and double temperature
display mode showing the actual and the target temperature.
4 hour time and day of the week display
6 period programmable time and temperature settings
Internal or external temperature sensor option
Room temperature is displayed on increments of 0.5°C.
Adjustable temperature settings for occupants comfort
Memory storage in event of power failure
The Komfort Touch+ Thermostat room temperature is programmed for
automatic operation.
Komfort Touch+ Stat Symbols
Symbol Symbol Description
On / Off Button
Function Key
Time Setting
Increase
Decrease
Setting utomatic Heating Control
Touch+ Programmable Thermostat
ll these settings should be programmed with Thermostat Power On
1) Time Setting and Day of Week
•
Press key
once to change to the correct time using
or
to
adjust the hour. Then press again to change the minute then
finally
again to change the day of the week.
2) Programming the number of Days
•
Hold
for 5 seconds screen will display looP
•
Press
Screen will display
“1 345”
Mon to Fri
(this will allow you to
set the weekend with different temperatures than the week
);
Or press
again, and the screen will display
“1 3456”
Mon to Sat
(allowing just Sunday to be set differently)
Or press
again, and the screen will display
“1 3456
,
7”
Mon to Sun
(to set all days the same).
•Once the days are set tap once to go straight into your
temperature and time settings
3) Setting Temperatures and Time Settings
•The instructions above brings you to Event 1 - Press
or
to adjust
temperature
•
Press to set scheduled time, press
or
to adjust hour.
1. Default Factory Heat Settings
Days Event Icon Time Period Temp.
1 – 6
Monday
to
Saturday
1
06.00 hrs
0° C
08.00 hrs
15° C
3
11.30 hrs
15° C
4
1 .30 hrs
15° C
5
17.30 hrs
° C
6
.00 hrs
15° C
Sunday
1
08.00 hrs
15° C
3.00
hrs
15° C
N.B. The thermostat will have the above settings by default
•The press to change minute again using
or
. Press
to move to the next event
•Follow in same manner above until you have set all the Events
1-6 as required for your programmed days
Please Note: Once your auto heat settings have been set there may be times
when you want to manually adjust your temperature settings for a short interval using
or
. Hand will temporally flash if you have altered your auto heat settings but once
the next scheduled heat setting starts it will return back to auto control settings (no
hand). To constantly override your auto temperatures tap once (hand constant). To
revert back to auto heat setting, tap
(no hand)

To access advanced settings, in power o
ff
state
,
press and hold
and tap .
Press to move through the symbol settings. To adjust settings
use
, tap
to confirm and to move to next symbol setting.
Touch+ Programmable Thermostat
Power Supply: AC 0~ 40V, 50/60HZ
Load Current: 3A(Water Heating)
Accuracy: ±0.5°C
Room Temperature Range: 5°C - 60°C
Remote Limit Temperature Range: 5-99°C
Consumption: <0.3W
Temperature Sensor: NTC
Size: 86*86*17mm (H*W*D)
Technical Data
dvanced Settings
No. Symbol Item Parameter Setting Function Factory Default Setting
1
5E
n
Sensor Reading O
ption
0:
Room Sensor
1: Remote Sensor
: Room & Remote Sensor
0:
Room Sensor
05
U
Remote Temperature S
etting
5
-
99°C
4 °C
3
dIF
Remote Temperature Difference Limit
-
Difference between Target Temperature and Calling For Heat
1
-
9 °C
°C
4
5UH
Temperature High Limit S
etting
5
-
99°C
35°C
5
5
UL
Temperature Low Limit S
etting
5
-
99°C
5°C
6
AdJ
Temperature C
alibration
Measure temp
-
Calibrate if necessary
0.1
7
F
r
E
Frost Protection
00: Off
01: On
00
: Off
8
Po
n
Memory
00: Off
01: On
00:
Off
9 FAC Factory Default 00: To Restore Factory Settings
08: Default Display Number (no meaning)
08: Default Display Number
Notes
ELECTRICI N / ENGINEER INSTRUCTIONS
Temperature can be temporally adjusted using
or
. The hand will flash to show the temporary
temperature adjustment but will disappear and return back to auto when your next scheduled
temperature setting starts.
Setting temperature to 00.0°C will shut down the scheduled setting
The thermostat offers a choice of room sensor, remote sensor or alternatively both together
When set to room sensor the display shows ROOM TEMP when set to remote sensor temperature the
display shows OUT TEMP
When using dual sensors, to check floor temperature setting – in power on state, press and hold
then tap once
Display will show Er if the remote sensor has been set but it is not actually connected or if it is
damaged
POWER WIRING
DI GR M
To open
,
push a flat screwdriver
in to both slots in the bottom of
the thermostat
Push the back from the front
as shown, remove connecting
plug
Connect up wiring as
indicated putting actuator
live on terminal
Screw thermostat back
plate to 35mm wall box
with screws provided
Re connect plug and
snap thermostat on
to lugs
INST LL TION
INST LL TION
DIMENSIONS
Table of contents
Popular Thermostat manuals by other brands

Trane
Trane TR-SAS908MTW-0-F3 Product data sheet

Bosch
Bosch Radiator thermostat II Quick instructions

Julabo
Julabo MV-4 manual

Honeywell
Honeywell Connected Home Single Zone Thermostat Installation tips

Siemens
Siemens RAZ-TW Installation Instructions for authorized personnel

Lennox
Lennox S40 Installer quick start guide