Ultra Auto Tech Ultra Start 500 Series User manual

500/550 SERIES
REV.2014.9.16
ADVANCED VEHICLE SECURITY SYSTEM
INSTALLATION GUIDE
TM
FCC ID NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions:
1. This device may not cause harmful interference, and
2.This device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by the part responsible for compliance void the user’s authority to operate
this devise.
www.ultrastarters.com

Wire Diagram.................................................................Page 3
Program Mode...............................................................Page 4
Enter Program Mode
System Reset
Programing Chart..........................................................Page 5
Program Menu 1
Program Menu 2
System Wiring................................................................Page 6-8
Wire Description
Shock Sensor Input
Antenna Valet/Programming Switch
Data Port
Transmitter Programming.............................................Page 9
Entering Remote Program Mode
Programming Remotes
Second Car & Padlock
System Operation: 2 way.............................................Page 10-11
System Operations: 1 way............................................Page 12-13
Anti Carjack Mode......................................................Page 14
Ant Carjack Feature
Anti Carjack Alert
Disarming Anti Carjack Feature
Diagnostics....................................................................Page 15
Contact Information .....................................................Page 16
SYSTEM PROGRAMMING - Menu 1
PAGE 2
INSTALL MANUAL
TABLE OF CONTENTS
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 3
INSTALL MANUAL
WIRE DIAGRAM
Pin 5 - WHITE - Park Light Output (+ or -)*
Pin 4 - RED/WHITE - Trunk Release (+ or -)**
Pin 3 - BLACK - Ground Input (-)
Pin 2 - RED - Constant 12volt Input (+)
Pin 1 - BROWN - Siren (+12V)
Pin 9 - WHITE/GREEN - 2nd Unlock / (-) When Disarm
Pin 8 - BLUE - Trunk Switch (-)
Pin 7 - GREEN - Negative Door Pin Input (-)
Pin 6 - VIOLET - Positive Door Pin Input (+)
Pin 5 - YELLOW - Switched Ignition Input (+)
Pin 4 - BLACK/WHITE - Dome Light / Aux 3 Output
Pin 3 - ORANGE - Ground When Armed (-250mA)
Pin 2 - BROWN - Horn / Aux 2 Output (-250mA)
Pin 1 - WHITE/BLUE - Aux 1 Output (-250mA)
Optional Communication Port
LED / VALET Switch
RF Antenna
Optional LED port
Pin 3 - Blue - Negative Unlock Output (-250mA)
Pin 2 - Output for Voltage Inverter Only
Pin 1 - Green - Negative Lock Output (-250mA)
Pin 4 - Red - 12volt Output for Sensor
Pin 3 - Black - Ground Output for Sensor
Pin 2 - White - Full Alarm Trigger Input (-)
Pin 1 - Blue - Warn Away Trigger Input (-)
*Park Lights are Jumper Selectable. Default Positive.
**Trunk Release is Jumper Selectable. Default Negative.
U500/U550
- +
- + Jumper ’s
Trunk Release
Park Lights
EXTERNAL STARTER INTERRUPT
CONNECTOR (OPTIONAL)
Status LED

Wire Diagram.................................................................Page 3
Program Mode...............................................................Page 4
Enter Program Mode
System Reset
Programing Chart..........................................................Page 5
Program Menu 1
Program Menu 2
System Wiring................................................................Page 6-8
Wire Description
Shock Sensor Input
Antenna Valet/Programming Switch
Data Port
Transmitter Programming.............................................Page 9
Entering Remote Program Mode
Programming Remotes
Second Car & Padlock
System Operation: 2 way.............................................Page 10-11
System Operations: 1 way............................................Page 12-13
Anti Carjack Mode......................................................Page 14
Ant Carjack Feature
Anti Carjack Alert
Disarming Anti Carjack Feature
Diagnostics....................................................................Page 15
Contact Information .....................................................Page 16
SYSTEM PROGRAMMING - Menu 1
PAGE 2
INSTALL MANUAL
TABLE OF CONTENTS
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 3
INSTALL MANUAL
WIRE DIAGRAM
Pin 5 - WHITE - Park Light Output (+ or -)*
Pin 4 - RED/WHITE - Trunk Release (+ or -)**
Pin 3 - BLACK - Ground Input (-)
Pin 2 - RED - Constant 12volt Input (+)
Pin 1 - BROWN - Siren (+12V)
Pin 9 - WHITE/GREEN - 2nd Unlock / (-) When Disarm
Pin 8 - BLUE - Trunk Switch (-)
Pin 7 - GREEN - Negative Door Pin Input (-)
Pin 6 - VIOLET - Positive Door Pin Input (+)
Pin 5 - YELLOW - Switched Ignition Input (+)
Pin 4 - BLACK/WHITE - Dome Light / Aux 3 Output
Pin 3 - ORANGE - Ground When Armed (-250mA)
Pin 2 - BROWN - Horn / Aux 2 Output (-250mA)
Pin 1 - WHITE/BLUE - Aux 1 Output (-250mA)
Optional Communication Port
LED / VALET Switch
RF Antenna
Optional LED port
Pin 3 - Blue - Negative Unlock Output (-250mA)
Pin 2 - Output for Voltage Inverter Only
Pin 1 - Green - Negative Lock Output (-250mA)
Pin 4 - Red - 12volt Output for Sensor
Pin 3 - Black - Ground Output for Sensor
Pin 2 - White - Full Alarm Trigger Input (-)
Pin 1 - Blue - Warn Away Trigger Input (-)
*Park Lights are Jumper Selectable. Default Positive.
**Trunk Release is Jumper Selectable. Default Negative.
U500/U550
- +
- + Jumper ’s
Trunk Release
Park Lights
EXTERNAL STARTER INTERRUPT
CONNECTOR (OPTIONAL)
Status LED

1 - Cycle the Ignition Key On/Off On/Off On.
(Leave the key in the ON position)
2 - Press and release the Program Switch 1 time.
(*The Siren will chirp to confirm that the system has entered Program Mode.)
*If the siren does not chirp repeat steps 1 & 2.
3 - Select the Program Menu.
-Press the Lock Button To Enter Menu 1.
-Press the Unlock Button to Enter Menu 2.
(*The Siren will chirp to confirm that the system has entered the Menu.)
See the following page for Program Menus and Settings.
4 - Press and Release the Program Switch to advance through the settings.
(Each setting is Confirmed by Siren Chirps & LED flashes)
5 - Press and hold the Program Switch to change the setting.
(Confirmed by Siren Chirps*)
* One Chirp = Setting 1
**Two Chirps = Setting 2
***Three Chirps = Setting 3
6 - To exit Program Mode, turn ignition key off.
(Confirmed by Long Siren Chirp)
ENTERING PROGRAM MODE
SYSTEM PROGRAMMING - Menu 1
PAGE 4
INSTALL MANUAL
PROGRAM MODE
1 - Cycle the Ignition Key On/Off On/Off On.
(Leave the key in the ON position)
2 - Press and release the Program Switch 1 time.
(*The Siren will chirp to confirm that the system has entered Program Mode.)
*If the siren does not chirp repeat steps 1 & 2.
3- Press and Hold the program switch until the siren chirps 3 times.
(The system is now reset to default settings)
SYSTEM RESET
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 5
INSTALL MANUAL
PROGRAM MODE
SETTING #
LED FLASHES
2
3
1
PARK LIGHT
OUTPUT
30 SECOND ON
FOR DISARM N/A
OPTION 3
3 CHIRPS
OPTION 1
1 CHIRP
OPTION 2
2 CHIRPS
AUX 1
BUTTON 3**
VALET
SETTINGS
0.75 SECOND
PULSED OUTPUT
SECURE VALET
15 SECONDS
LATCHED
IGNITION ON RESET
ACTIVE WHILE
BUTTON IS HELD
STANDARD VALET
8 SECONDS
SETTING
DESCRIPTION
SETTING #
LED FLASHES
1
2
3
4
5
6
7
IGNITION
AUTO-LOCK
IGNITION AUTO-LOCK &
UNLOCK ENABLED
IGNITION AUTO-LOCK
ONLY
OPTION 3
3 CHIRPS
IGNITION AUTO-LOCK
DISABLED
OPTION 1
1 CHIRP
OPTION 2
2 CHIRPS
SIREN SETTINGS
DOOR LOCK
OPTIONS
DOOR LOCK
PULSE TIMES
SHOCK SENSOR
SETTINGS
PASSIVE ARMING
PASSIVE
DOOR LOCKS
SIREN CHIRPS
DISABLED
DOUBLE UNLOCK /
SINGLE LOCK PULSES
0.25 SECOND
PULSES
SENSOR DISABLED
FULL
PASSIVE ARMING
PASSIVE DOOR LOCKS
DISABLED
DOUBLE LOCK /
SINGLE UNLOCK PULSES
3 SECOND
PULSES
SENSOR ENABLED
PASSIVE DOOR LOCKS
ENABLED
SIREN CHIRPS
ENABLED
SINGLE UNLOCK /
SINGLE LOCK PULSES
0.75 SECOND
PULSES
ALL PASSIVE ARMING
DISABLED
SETTING
DESCRIPTION
PROGRAM MODE 1
PROGRAM MODE 2
4
5
ANIT-CARJACK MODE
OPTIONS***
HORN OUTPUT
TIMING
CARJACK MODE 1
50mS HORN
OUTPUT
20mS HORN
OUTPUT
CARJACK MODE
DISABLED
10mS HORN
OUTPUT
6AUX 2 (HORN / AUX)
Button 3 & 4**
0.75 SEC
PULSED OUTPUT
ACTIVE WHILE BUTTON
IS HELD
HORN OUTPUT &
CAR FINDER
7AUX 3 (DOME LIGHT)
Button 1 & 3**
0.75 SEC
PULSED OUTPUT
ACTIVE WHILE BUTTON
IS HELD DOME LIGHT OUTPUT
82ND UNLOCK/ (-) WHEN
DISARMED
GROUND WHEN
DISARMED
SECOND UNLOCK
OUTPUT
PASSIVE SAFETY
REARM ONLY
NORMAL OPERATION
CARJACK MODE 2
= DEFAULT SETTING
8UNIT MODE 2 WAY (U550) 1 WAY (U500)
U500/U550
*** Available in International Version
** 1 way: Button 1 - lock, Button 2 - unlock, Button 3 - *, Button 4 - #
** 2 way: Button 1 - lock, Button 2 - unlock, Button 3 - Start, Button 4 - Trunk

1 - Cycle the Ignition Key On/Off On/Off On.
(Leave the key in the ON position)
2 - Press and release the Program Switch 1 time.
(*The Siren will chirp to confirm that the system has entered Program Mode.)
*If the siren does not chirp repeat steps 1 & 2.
3 - Select the Program Menu.
-Press the Lock Button To Enter Menu 1.
-Press the Unlock Button to Enter Menu 2.
(*The Siren will chirp to confirm that the system has entered the Menu.)
See the following page for Program Menus and Settings.
4 - Press and Release the Program Switch to advance through the settings.
(Each setting is Confirmed by Siren Chirps & LED flashes)
5 - Press and hold the Program Switch to change the setting.
(Confirmed by Siren Chirps*)
* One Chirp = Setting 1
**Two Chirps = Setting 2
***Three Chirps = Setting 3
6 - To exit Program Mode, turn ignition key off.
(Confirmed by Long Siren Chirp)
ENTERING PROGRAM MODE
SYSTEM PROGRAMMING - Menu 1
PAGE 4
INSTALL MANUAL
PROGRAM MODE
1 - Cycle the Ignition Key On/Off On/Off On.
(Leave the key in the ON position)
2 - Press and release the Program Switch 1 time.
(*The Siren will chirp to confirm that the system has entered Program Mode.)
*If the siren does not chirp repeat steps 1 & 2.
3- Press and Hold the program switch until the siren chirps 3 times.
(The system is now reset to default settings)
SYSTEM RESET
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 5
INSTALL MANUAL
PROGRAM MODE
SETTING #
LED FLASHES
2
3
1
PARK LIGHT
OUTPUT
30 SECOND ON
FOR DISARM N/A
OPTION 3
3 CHIRPS
OPTION 1
1 CHIRP
OPTION 2
2 CHIRPS
AUX 1
BUTTON 3**
VALET
SETTINGS
0.75 SECOND
PULSED OUTPUT
SECURE VALET
15 SECONDS
LATCHED
IGNITION ON RESET
ACTIVE WHILE
BUTTON IS HELD
STANDARD VALET
8 SECONDS
SETTING
DESCRIPTION
SETTING #
LED FLASHES
1
2
3
4
5
6
7
IGNITION
AUTO-LOCK
IGNITION AUTO-LOCK &
UNLOCK ENABLED
IGNITION AUTO-LOCK
ONLY
OPTION 3
3 CHIRPS
IGNITION AUTO-LOCK
DISABLED
OPTION 1
1 CHIRP
OPTION 2
2 CHIRPS
SIREN SETTINGS
DOOR LOCK
OPTIONS
DOOR LOCK
PULSE TIMES
SHOCK SENSOR
SETTINGS
PASSIVE ARMING
PASSIVE
DOOR LOCKS
SIREN CHIRPS
DISABLED
DOUBLE UNLOCK /
SINGLE LOCK PULSES
0.25 SECOND
PULSES
SENSOR DISABLED
FULL
PASSIVE ARMING
PASSIVE DOOR LOCKS
DISABLED
DOUBLE LOCK /
SINGLE UNLOCK PULSES
3 SECOND
PULSES
SENSOR ENABLED
PASSIVE DOOR LOCKS
ENABLED
SIREN CHIRPS
ENABLED
SINGLE UNLOCK /
SINGLE LOCK PULSES
0.75 SECOND
PULSES
ALL PASSIVE ARMING
DISABLED
SETTING
DESCRIPTION
PROGRAM MODE 1
PROGRAM MODE 2
4
5
ANIT-CARJACK MODE
OPTIONS***
HORN OUTPUT
TIMING
CARJACK MODE 1
50mS HORN
OUTPUT
20mS HORN
OUTPUT
CARJACK MODE
DISABLED
10mS HORN
OUTPUT
6AUX 2 (HORN / AUX)
Button 3 & 4**
0.75 SEC
PULSED OUTPUT
ACTIVE WHILE BUTTON
IS HELD
HORN OUTPUT &
CAR FINDER
7AUX 3 (DOME LIGHT)
Button 1 & 3**
0.75 SEC
PULSED OUTPUT
ACTIVE WHILE BUTTON
IS HELD DOME LIGHT OUTPUT
82ND UNLOCK/ (-) WHEN
DISARMED
GROUND WHEN
DISARMED
SECOND UNLOCK
OUTPUT
PASSIVE SAFETY
REARM ONLY
NORMAL OPERATION
CARJACK MODE 2
= DEFAULT SETTING
8UNIT MODE 2 WAY (U550) 1 WAY (U500)
U500/U550
*** Available in International Version
** 1 way: Button 1 - lock, Button 2 - unlock, Button 3 - *, Button 4 - #
** 2 way: Button 1 - lock, Button 2 - unlock, Button 3 - Start, Button 4 - Trunk

WIRE DESCRIPTION
SYSTEM PROGRAMMING - Menu 1
PAGE 6
INSTALL MANUAL
SYSTEM WIRING
Pin 1- White/Blue Wire- AUX Channel 1 (Hold the Button 3**)
Pin 4- Black/White Wire- Dome Light/ AUX 3 Output (Hold Button 1 & 3**)
Pin 2- Brown Wire- Horn Output/ AUX Channel 2 (Hold Button 3 & 4**)
Pin 1- Brown- Siren Output (+)
Pin 5- White- Park Light Output (+ or -) (Hold Trunk Button)
Pin 2- Red- Constant 12volt Input
Pin 3- Black- System Ground Input (-)
Pin 4- Red/White- Trunk Release (- or +) (Hold Trunk Button)
Pin 3- Orange Wire- Ground When Armed/ Starter Disable
Pin 7- Green Wire- Negative Door Pin Input (-)
Pin 6- Violet Wire- Positive Door Pin Input (+)
Pin 8- Blue Wire- Hood/ Trunk Switch Input (-)
Pin 5- Yellow Wire- Switched Ignition Input (+)
Pin 9- White/Green Wire- 2nd Unlock/ (-) When Disarmed Output
Pin 1- Green Wire- Negative Lock Output (-250ma Output)
Pin 2- 12volt Output for Voltage Inverter.
Pin 3- Blue Wire- Negative Unlock Output (-250ma Output)
U500/U550
** 1 way: Button 1 - lock, Button 2 - unlock, Button 3 - *, Button 4 - #
** 2 way: Button 1 - lock, Button 2 - unlock, Button 3 - Start, Button 4 - Trunk
SYSTEM PROGRAMMING - Menu 1
PAGE 7
INSTALL MANUAL
SYSTEM WIRING
Blue
Red
Green
(-) Output When Unlock Is Pressed For 1 Second. (Programmable)
(+) LOW CURRENT OUTPUT FOR VOLTAGE INVERTER ONLY.
(-) Output When Lock Is Pressed For One Second. (Programmable)
White/Green
Blue
Green
(-) 2nd Unlock Output / Ground Output When Disarmed. (Programmable)
(-) Hood/ Trunk Switch Detection.
(-) Door Pin Switch Input For Door Pin Detection.
Violet
Yellow
(+) Door Pin Switch Input For Door Pin Detection.
(+) Switched Ignition Input. This Wire Must Be Connected.
Black/White
Orange
Brown
(-) 30 Second Output When Disarmed/ AUX 3. (Programmable)
(-) Continuos Output When The Lock Button Is Pressed.
(-) Output For Horn Honk/ Car Finder. (Programmable).
White/Blue (-) Active Output When The * Button Is Held. (Programmable).
White Jumper Selectable Output From Park Light Relay. Default is Positive Park Lights.
Red/White
Black
Red
Jumper Selectable Output From Trunk Relay. Default is Negative Trunk Release.
System Ground Input. Connect To Chassis Ground.
System 12volt Supply. Connect To Constant 12 Volt Source.
Brown Output For Siren Activation. (+) 2amp Max.
WIRE DESCRIPTION
U500/U550

WIRE DESCRIPTION
SYSTEM PROGRAMMING - Menu 1
PAGE 6
INSTALL MANUAL
SYSTEM WIRING
Pin 1- White/Blue Wire- AUX Channel 1 (Hold the Button 3**)
Pin 4- Black/White Wire- Dome Light/ AUX 3 Output (Hold Button 1 & 3**)
Pin 2- Brown Wire- Horn Output/ AUX Channel 2 (Hold Button 3 & 4**)
Pin 1- Brown- Siren Output (+)
Pin 5- White- Park Light Output (+ or -) (Hold Trunk Button)
Pin 2- Red- Constant 12volt Input
Pin 3- Black- System Ground Input (-)
Pin 4- Red/White- Trunk Release (- or +) (Hold Trunk Button)
Pin 3- Orange Wire- Ground When Armed/ Starter Disable
Pin 7- Green Wire- Negative Door Pin Input (-)
Pin 6- Violet Wire- Positive Door Pin Input (+)
Pin 8- Blue Wire- Hood/ Trunk Switch Input (-)
Pin 5- Yellow Wire- Switched Ignition Input (+)
Pin 9- White/Green Wire- 2nd Unlock/ (-) When Disarmed Output
Pin 1- Green Wire- Negative Lock Output (-250ma Output)
Pin 2- 12volt Output for Voltage Inverter.
Pin 3- Blue Wire- Negative Unlock Output (-250ma Output)
U500/U550
** 1 way: Button 1 - lock, Button 2 - unlock, Button 3 - *, Button 4 - #
** 2 way: Button 1 - lock, Button 2 - unlock, Button 3 - Start, Button 4 - Trunk
SYSTEM PROGRAMMING - Menu 1
PAGE 7
INSTALL MANUAL
SYSTEM WIRING
Blue
Red
Green
(-) Output When Unlock Is Pressed For 1 Second. (Programmable)
(+) LOW CURRENT OUTPUT FOR VOLTAGE INVERTER ONLY.
(-) Output When Lock Is Pressed For One Second. (Programmable)
White/Green
Blue
Green
(-) 2nd Unlock Output / Ground Output When Disarmed. (Programmable)
(-) Hood/ Trunk Switch Detection.
(-) Door Pin Switch Input For Door Pin Detection.
Violet
Yellow
(+) Door Pin Switch Input For Door Pin Detection.
(+) Switched Ignition Input. This Wire Must Be Connected.
Black/White
Orange
Brown
(-) 30 Second Output When Disarmed/ AUX 3. (Programmable)
(-) Continuos Output When The Lock Button Is Pressed.
(-) Output For Horn Honk/ Car Finder. (Programmable).
White/Blue (-) Active Output When The * Button Is Held. (Programmable).
White Jumper Selectable Output From Park Light Relay. Default is Positive Park Lights.
Red/White
Black
Red
Jumper Selectable Output From Trunk Relay. Default is Negative Trunk Release.
System Ground Input. Connect To Chassis Ground.
System 12volt Supply. Connect To Constant 12 Volt Source.
Brown Output For Siren Activation. (+) 2amp Max.
WIRE DESCRIPTION
U500/U550

SHOCK SENSOR INPUT
SYSTEM PROGRAMMING - Menu 1
PAGE 8
INSTALL MANUAL
SYSTEM WIRING
PIN 4 Red
PIN 3 Black
PIN 2 White
12 Volt Output For Auxiliary Sensor.
The Data Port Connector Is Used For Fortin and I-Data Bypass Modules As Well As Compatible
Tracking Units.
Ground Output For Auxiliary Sensor.
Full Trigger Input For Auxiliary Sensor.
PIN 1 Blue Warn-away Input For Auxiliary Sensor.
ANTENNA/ VALET / PROGRAMMING SWITCH
For maximum range mount the Antenna in the center of the windshield, behind the rear-view mirror.
The antenna also contains the program/ valet switch as well as status LEDs for system status and
diagnostics.
DATA PORT
U500/U550
The supplied dual stage shock sensor connects directly to the shock sensor connector on the
alarm module. The adjustment screw on the sensor will increase or decrease the sensitivity. The
first and second stage are controlled by the same adjustment screw.
Test the alarm sensitivity then adust as required. If the alarm is triggered 3 times in a row you will
need to cycle the ignition on then off to reset the shock sensor before testing again.
If a secondary sensor is being installed, the wiring for the connector is as follows:
SYSTEM PROGRAMMING - Menu 1
PAGE 9
INSTALL MANUAL
TRANSMITTER PROGRAMMING
PROGRAMMING TRANSMITTERS
SECOND CAR & PADLOCK
Press and HOLD the valet switch, the Park Lights will turn on.
*The Siren will Chirp once.
(Repeat from Step 1 if the system does not respond)
Cycle the Ignition Key - ON/OFF ON/OFF ON
(Leaving the key ON)
The system can learn up to 3 different remotes. Each remote to be used MUST be programmed
together during the same sequence. For security, when a new remote is programmed all
previous remotes are deleted. Please see remote operation chart for information on using
Second Car / Padlock Operations.
After 5 seconds the park lights will turn off.
*The Siren will Chirp 5 times.
Press and release the Lock Button on each of the remote to be programmed.
See notes below if the remote is to be programmed for 2nd car or PADLOCK.
The system will respond by flashing the park lights for each remote.
*The Siren will Chirp once for each remote.
Turn off the key when all the remotes are programmed.
PADLOCK is used to prevent accidental activation on the remote. The Trunk Button must be
pressed once before the intended feature button. (See Second Car/ PADLOCK operation)
Use the same remote programming mode and program the transmitter using the Trunk Button
instead on the Lock Button.
2nd Car Operation allows a single remote to control two vehicles. Use the same remote
programming mode and enter the transmitter as shown below.
In Car One- Press Lock on car 1 remote. Press Trunk button on car 2 remote.
In Car Two- Press Lock on car 2 remote. Press Trunk button on car 1 remote.
PROGRAMMING REMOTE
ENTERING REMOTE PROGRAM MODE
U500/U550

SHOCK SENSOR INPUT
SYSTEM PROGRAMMING - Menu 1
PAGE 8
INSTALL MANUAL
SYSTEM WIRING
PIN 4 Red
PIN 3 Black
PIN 2 White
12 Volt Output For Auxiliary Sensor.
The Data Port Connector Is Used For Fortin and I-Data Bypass Modules As Well As Compatible
Tracking Units.
Ground Output For Auxiliary Sensor.
Full Trigger Input For Auxiliary Sensor.
PIN 1 Blue Warn-away Input For Auxiliary Sensor.
ANTENNA/ VALET / PROGRAMMING SWITCH
For maximum range mount the Antenna in the center of the windshield, behind the rear-view mirror.
The antenna also contains the program/ valet switch as well as status LEDs for system status and
diagnostics.
DATA PORT
U500/U550
The supplied dual stage shock sensor connects directly to the shock sensor connector on the
alarm module. The adjustment screw on the sensor will increase or decrease the sensitivity. The
first and second stage are controlled by the same adjustment screw.
Test the alarm sensitivity then adust as required. If the alarm is triggered 3 times in a row you will
need to cycle the ignition on then off to reset the shock sensor before testing again.
If a secondary sensor is being installed, the wiring for the connector is as follows:
SYSTEM PROGRAMMING - Menu 1
PAGE 9
INSTALL MANUAL
TRANSMITTER PROGRAMMING
PROGRAMMING TRANSMITTERS
SECOND CAR & PADLOCK
Press and HOLD the valet switch, the Park Lights will turn on.
*The Siren will Chirp once.
(Repeat from Step 1 if the system does not respond)
Cycle the Ignition Key - ON/OFF ON/OFF ON
(Leaving the key ON)
The system can learn up to 3 different remotes. Each remote to be used MUST be programmed
together during the same sequence. For security, when a new remote is programmed all
previous remotes are deleted. Please see remote operation chart for information on using
Second Car / Padlock Operations.
After 5 seconds the park lights will turn off.
*The Siren will Chirp 5 times.
Press and release the Lock Button on each of the remote to be programmed.
See notes below if the remote is to be programmed for 2nd car or PADLOCK.
The system will respond by flashing the park lights for each remote.
*The Siren will Chirp once for each remote.
Turn off the key when all the remotes are programmed.
PADLOCK is used to prevent accidental activation on the remote. The Trunk Button must be
pressed once before the intended feature button. (See Second Car/ PADLOCK operation)
Use the same remote programming mode and program the transmitter using the Trunk Button
instead on the Lock Button.
2nd Car Operation allows a single remote to control two vehicles. Use the same remote
programming mode and enter the transmitter as shown below.
In Car One- Press Lock on car 1 remote. Press Trunk button on car 2 remote.
In Car Two- Press Lock on car 2 remote. Press Trunk button on car 1 remote.
PROGRAMMING REMOTE
ENTERING REMOTE PROGRAM MODE
U500/U550

SYSTEM PROGRAMMING - Menu 1
PAGE 11
INSTALL MANUAL
SYSTEM OPERATIONS (2 WAY)
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 10
INSTALL MANUAL
SYSTEM OPERATIONS (2 WAY)
U500/U550
BUTTON BUTTON CHIRP/ SYSTEM FUNCTION
ICON DURATION FLASH
1 SECOND
1 SECOND
1
0
ARM ALARM / LOCK DOORS
STATUS CHECK
3 SECONDS
3 SECONDS
1
0
ACTIVATE PANIC MODE
ENTER PROGRAM MODE
1 SECOND 2DISARM ALARM / UNLOCK DOORS
1 SECOND - 1 SECOND 3 DRIVER’S DOOR PRIORITY
(OPTIONAL / PROGRAMMABLE)
3 SECONDS 1 AUX 1 OUTPUT**
PRESS TOGETHER
FOR 1 SECOND
FLASH
ONLY SILENT LOCK/ UNLOCK
PRESS AND HOLD FOR
3 SECONDS 2 ACTIVATES TRUNK RELEASE**
#
+
BUTTON BUTTON CHIRP/ SYSTEM FUNCTION
ICON DURATION FLASH
PRESS TOGETHER
FOR 3 SECONDS
PRESS TOGETHER
FOR 3 SECONDS
TUNE ENTER CLOCK ADJUST MODE
FOR REMOTE
PRESS TOGETHER
FOR 3 SECONDS 1AUX 3 OUTPUT**
(DEALER OPTION)
PRESS TOGETHER
FOR 3 SECONDS NONE REMOTE VIBRATION MODE
ON / OFF
+
+
+
+
5 CAR FINDER (DEFAULT)
1 AUX 2 (DEALER OPTION)**
#
#
PRESS AND RELEASE
LOCK THEN PRESS AND
RELEASE TRUNK
1
ARMS / LOCKS AND TURNS OFF
SHOCK SENSOR
(FOR 1 ARM CYCLE ONLY)
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS

SYSTEM PROGRAMMING - Menu 1
PAGE 11
INSTALL MANUAL
SYSTEM OPERATIONS (2 WAY)
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 10
INSTALL MANUAL
SYSTEM OPERATIONS (2 WAY)
U500/U550
BUTTON BUTTON CHIRP/ SYSTEM FUNCTION
ICON DURATION FLASH
1 SECOND
1 SECOND
1
0
ARM ALARM / LOCK DOORS
STATUS CHECK
3 SECONDS
3 SECONDS
1
0
ACTIVATE PANIC MODE
ENTER PROGRAM MODE
1 SECOND 2DISARM ALARM / UNLOCK DOORS
1 SECOND - 1 SECOND 3 DRIVER’S DOOR PRIORITY
(OPTIONAL / PROGRAMMABLE)
3 SECONDS 1 AUX 1 OUTPUT**
PRESS TOGETHER
FOR 1 SECOND
FLASH
ONLY SILENT LOCK/ UNLOCK
PRESS AND HOLD FOR
3 SECONDS 2 ACTIVATES TRUNK RELEASE**
#
+
BUTTON BUTTON CHIRP/ SYSTEM FUNCTION
ICON DURATION FLASH
PRESS TOGETHER
FOR 3 SECONDS
PRESS TOGETHER
FOR 3 SECONDS
TUNE ENTER CLOCK ADJUST MODE
FOR REMOTE
PRESS TOGETHER
FOR 3 SECONDS 1AUX 3 OUTPUT**
(DEALER OPTION)
PRESS TOGETHER
FOR 3 SECONDS NONE REMOTE VIBRATION MODE
ON / OFF
+
+
+
+
5 CAR FINDER (DEFAULT)
1 AUX 2 (DEALER OPTION)**
#
#
PRESS AND RELEASE
LOCK THEN PRESS AND
RELEASE TRUNK
1
ARMS / LOCKS AND TURNS OFF
SHOCK SENSOR
(FOR 1 ARM CYCLE ONLY)
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS

SYSTEM PROGRAMMING - Menu 1
PAGE 12
INSTALL MANUAL
SYSTEM OPERATIONS (1 WAY)
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 13
INSTALL MANUAL
SYSTEM OPERATIONS (1 WAY)
U500/U550
1 SECOND 1 LOCK / ARM ALARM
3 SECONDS 1 ACTIVATE PANIC
PRESS THEN
RELEASE THEN
PRESS & HOLD
1ACTIVATE CONSTANT LOCK
OUTPUT **
LOCK
BUTTON PRESS CHIRP /
FLASH SYSTEM FUNCTION
BUTTON
1 SECOND 2 UNLOCK / DISARM
1 SECOND
WHILE ALARM IS
TRIGGERED
NONE TURNS OFF SIREN BUT ALARM IS
STILL ARMED
1 SECOND 3
UNLOCK / DISARM
ALARM EVENT IN MEMORY
see alarm event memory chart
UNLOCK
HOLD FOR 3 SECONDS 1 ACTIVATES AUX OUTPUT**
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS
PRESS AND HOLD
FOR 3 SECONDS ON ACTIVATES TRUNK RELEASE**
+
NO SIREN CHIRPS - ACTS AS A TOGGLE - IF ARMED WILL DISARM, IF DISARMED WILL ARM
+
#
#
PRESS TOGETHER
FOR 3 SECONDS
5 CAR FINDER (DEFAULT)
1
PRESS TOGETHER
FOR 1 SECOND
FLASH
ONLY SILENT LOCK/ UNLOCK
PRESS AND RELEASE
LOCK THEN PRESS AND
RELEASE TRUNK
1
ARMS / LOCKS AND TURNS OFF
SHOCK SENSOR
(FOR 1 ARM CYCLE ONLY)
1 SECOND - 1 SECOND 1 LOCK / ARM ALARM
1 SECOND - 3 SECONDS 1 ACTIVATE PANIC ALARM
BUTTON PRESS CHIRP /
FLASH SYSTEM FUNCTION
BUTTON
1 SECOND - 1 SECOND 2UNLOCK / DISARM
1 SECOND - 1 SECOND
WHILE ALARM IS
TRIGGERED
NONE TURNS OFF SIREN BUT ALARM IS
STILL ARMED
1 SECOND - 1 SECOND 3
UNLOCK / DISARM
ALARM EVENT IN MEMORY
see alarm event memory chart
1 SECOND - 3 SECONDS 1 ACTIVATES AUX 1 OUTPUT
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS
SECOND CAR OPERATION/ PADLOCK. SEE TRANSMITTER PROGRAMMING
FOR INFORMATION ON PROGRAMMING THIS FEATURE.
1 SECOND - 3 SECONDS 1ACTIVATES TRUNK RELEASE
OUTPUT
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS
#
#
#
#
#
PRESS TOGETHER
FOR 3 SECONDS 1AUX 3 OUTPUT**
(DEALER OPTION)
+
#
AUX 2 (DEALER OPTION)**

SYSTEM PROGRAMMING - Menu 1
PAGE 12
INSTALL MANUAL
SYSTEM OPERATIONS (1 WAY)
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 13
INSTALL MANUAL
SYSTEM OPERATIONS (1 WAY)
U500/U550
1 SECOND 1 LOCK / ARM ALARM
3 SECONDS 1 ACTIVATE PANIC
PRESS THEN
RELEASE THEN
PRESS & HOLD
1ACTIVATE CONSTANT LOCK
OUTPUT **
LOCK
BUTTON PRESS CHIRP /
FLASH SYSTEM FUNCTION
BUTTON
1 SECOND 2 UNLOCK / DISARM
1 SECOND
WHILE ALARM IS
TRIGGERED
NONE TURNS OFF SIREN BUT ALARM IS
STILL ARMED
1 SECOND 3
UNLOCK / DISARM
ALARM EVENT IN MEMORY
see alarm event memory chart
UNLOCK
HOLD FOR 3 SECONDS 1 ACTIVATES AUX OUTPUT**
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS
PRESS AND HOLD
FOR 3 SECONDS ON ACTIVATES TRUNK RELEASE**
+
NO SIREN CHIRPS - ACTS AS A TOGGLE - IF ARMED WILL DISARM, IF DISARMED WILL ARM
+
#
#
PRESS TOGETHER
FOR 3 SECONDS
5 CAR FINDER (DEFAULT)
1
PRESS TOGETHER
FOR 1 SECOND
FLASH
ONLY SILENT LOCK/ UNLOCK
PRESS AND RELEASE
LOCK THEN PRESS AND
RELEASE TRUNK
1
ARMS / LOCKS AND TURNS OFF
SHOCK SENSOR
(FOR 1 ARM CYCLE ONLY)
1 SECOND - 1 SECOND 1 LOCK / ARM ALARM
1 SECOND - 3 SECONDS 1 ACTIVATE PANIC ALARM
BUTTON PRESS CHIRP /
FLASH SYSTEM FUNCTION
BUTTON
1 SECOND - 1 SECOND 2UNLOCK / DISARM
1 SECOND - 1 SECOND
WHILE ALARM IS
TRIGGERED
NONE TURNS OFF SIREN BUT ALARM IS
STILL ARMED
1 SECOND - 1 SECOND 3
UNLOCK / DISARM
ALARM EVENT IN MEMORY
see alarm event memory chart
1 SECOND - 3 SECONDS 1 ACTIVATES AUX 1 OUTPUT
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS
SECOND CAR OPERATION/ PADLOCK. SEE TRANSMITTER PROGRAMMING
FOR INFORMATION ON PROGRAMMING THIS FEATURE.
1 SECOND - 3 SECONDS 1ACTIVATES TRUNK RELEASE
OUTPUT
** PROGRAMMABLE OUTPUT - CHECK WITH INSTALLATION CENTER FOR DETAILS
#
#
#
#
#
PRESS TOGETHER
FOR 3 SECONDS 1AUX 3 OUTPUT**
(DEALER OPTION)
+
#
AUX 2 (DEALER OPTION)**

SYSTEM PROGRAMMING - Menu 1
PAGE 14
INSTALL MANUAL
ANTI CARJACK MODE
ACTIVATING ANTI CARJACK MODE (International Model Only)
Type-1 - The timer will start if the door is opened or if the # button is held for 3 seconds while
the ignition is on.
Type-2 - The timer will start if the door is opened or if the # button is held for 3 seconds while
the ignition is on. The timer will also start every time the ignition is turned on.
When programmed, the Anti Carjack timer is triggered when a door is opened or a button is
pressed on the remote while the ignition is on. Type 2 Carjack Mode will trigger the timer with
the door and trunk button as well as each time the ignition is turned on.
If Anti Carjack is triggered, there will be no indication in the first 20 seconds.
After 20 seconds the LED will begin to flash rapidly to indicate that the Carjack feature is
active. After an additional 20 seconds the siren will then start to chirp each second for an
additional 20 seconds.
The alarm will now activate, the ignition will interrupt, parking lights will flash, and the siren will
alert indicating trouble. The lights and siren will pause momentarily between each one minute
cycle, and repeat until disarmed.
Note - Turn the ignition key off before opening the door to avoid triggering the Anti Carjack
Feature. Pressing and releasing the valet button with the key on during the first 60 seconds will
stop the Carjack timer.
To disarm the Anti Carjack timer process during the initial 60 seconds of activation, turn the
ignition key off then on, then press the valet button momentarily.
To disarm the Anti Carjack alert process during the lights and siren cycles, turn the car off then
on, then press and hold the valet button for 5 seconds.
This feature requires that the user must be fully aware of the operation of this feature. If the
system goes into full alarm the remote will no longer function until the Anti Carjack Feature is
disabled.
ANTI CARJACK FEATURE
ANTI CAR JACK ALERT
DISARMING ANTI CARJACK FEATURE
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 15
INSTALL MANUAL
DIAGNOSTICS
U500/U550
ALARM STATUS / DIAGNOSTICS
OVERLOAD DIAGNOSTICS
SIREN CHIRPS LED FLASHES DIAGNOSTICS / STATUS
3 2 SHOCK SENSOR TRIGGER
3 3 DOOR / HOOD TRIGGER
3 4 IGNITION TRIGGER
0 OFF SYSTEM DISARMED
0 ON SOLID SYSTEM IN VALET / SERVICE MODE
0 SINGLE FLASHES SYSTEM ARMED
0 RAPID FLASHES PASSIVE ARM COUNTDOWN
If the alarm system is triggered, the system will retain in memory the cause of the
trigger. When disarming the alarm, the siren/horn will chirp 3 times to indicate the
alarm had been triggered. The system’s LED will also flash in pulses to indicate
which input triggered the alarm.
*LED status will be cleared when the ignition is turned ON. For proper memory
clearing, insure to connect the alarm ignition input to the ignition on the vehicle.
If an output from the alarm is shorted the siren will chirp 4 times and, the park lights
will flash 4 times when the system is armed or disarmed. The LED will flash a
diagnostic code that represents the circuit that is at fault. (See Chart Below). Turning
the ignition to the on then off position will reset the diagnostic code.
LED FLASHES OUTPUT DIAGNOSTICS
2 LOCK OUTPUT OVERLOAD
3 UNLOCK OUTPUT OVERLOAD
4 TRUNK OUTPUT OVERLOAD
5 STARTER DISABLE OVERLOAD
6 AUX 3 OUTPUT OVERLOAD
7 AUX 2 OUTPUT OVERLOAD
8 2ND UNLOCK OUTPUT OVERLOAD

SYSTEM PROGRAMMING - Menu 1
PAGE 14
INSTALL MANUAL
ANTI CARJACK MODE
ACTIVATING ANTI CARJACK MODE (International Model Only)
Type-1 - The timer will start if the door is opened or if the # button is held for 3 seconds while
the ignition is on.
Type-2 - The timer will start if the door is opened or if the # button is held for 3 seconds while
the ignition is on. The timer will also start every time the ignition is turned on.
When programmed, the Anti Carjack timer is triggered when a door is opened or a button is
pressed on the remote while the ignition is on. Type 2 Carjack Mode will trigger the timer with
the door and trunk button as well as each time the ignition is turned on.
If Anti Carjack is triggered, there will be no indication in the first 20 seconds.
After 20 seconds the LED will begin to flash rapidly to indicate that the Carjack feature is
active. After an additional 20 seconds the siren will then start to chirp each second for an
additional 20 seconds.
The alarm will now activate, the ignition will interrupt, parking lights will flash, and the siren will
alert indicating trouble. The lights and siren will pause momentarily between each one minute
cycle, and repeat until disarmed.
Note - Turn the ignition key off before opening the door to avoid triggering the Anti Carjack
Feature. Pressing and releasing the valet button with the key on during the first 60 seconds will
stop the Carjack timer.
To disarm the Anti Carjack timer process during the initial 60 seconds of activation, turn the
ignition key off then on, then press the valet button momentarily.
To disarm the Anti Carjack alert process during the lights and siren cycles, turn the car off then
on, then press and hold the valet button for 5 seconds.
This feature requires that the user must be fully aware of the operation of this feature. If the
system goes into full alarm the remote will no longer function until the Anti Carjack Feature is
disabled.
ANTI CARJACK FEATURE
ANTI CAR JACK ALERT
DISARMING ANTI CARJACK FEATURE
U500/U550
SYSTEM PROGRAMMING - Menu 1
PAGE 15
INSTALL MANUAL
DIAGNOSTICS
U500/U550
ALARM STATUS / DIAGNOSTICS
OVERLOAD DIAGNOSTICS
SIREN CHIRPS LED FLASHES DIAGNOSTICS / STATUS
3 2 SHOCK SENSOR TRIGGER
3 3 DOOR / HOOD TRIGGER
3 4 IGNITION TRIGGER
0 OFF SYSTEM DISARMED
0 ON SOLID SYSTEM IN VALET / SERVICE MODE
0 SINGLE FLASHES SYSTEM ARMED
0 RAPID FLASHES PASSIVE ARM COUNTDOWN
If the alarm system is triggered, the system will retain in memory the cause of the
trigger. When disarming the alarm, the siren/horn will chirp 3 times to indicate the
alarm had been triggered. The system’s LED will also flash in pulses to indicate
which input triggered the alarm.
*LED status will be cleared when the ignition is turned ON. For proper memory
clearing, insure to connect the alarm ignition input to the ignition on the vehicle.
If an output from the alarm is shorted the siren will chirp 4 times and, the park lights
will flash 4 times when the system is armed or disarmed. The LED will flash a
diagnostic code that represents the circuit that is at fault. (See Chart Below). Turning
the ignition to the on then off position will reset the diagnostic code.
LED FLASHES OUTPUT DIAGNOSTICS
2 LOCK OUTPUT OVERLOAD
3 UNLOCK OUTPUT OVERLOAD
4 TRUNK OUTPUT OVERLOAD
5 STARTER DISABLE OVERLOAD
6 AUX 3 OUTPUT OVERLOAD
7 AUX 2 OUTPUT OVERLOAD
8 2ND UNLOCK OUTPUT OVERLOAD

IMPORTANT NOTES
LOCK, UNLOCK, DRIVER'S DOOR PRIORITY UNLOCK, TRUNK RELEASE AND THE
AUXILIARY OUTPUTS ARE OPTIONAL OUTPUTS. ENABLING THESE FEATURES
REQUIRES CUSTOM INSTALLATION & PROGRAMMING. THESE FEATURES MAY NOT BE
COMPATIBLE WITH SOME VEHICLES.
FOR SAFETY REASONS THE TRUNK RELEASE OUTPUT WILL NOT ACTIVATE WHEN THE
IGNITION IS IN THE ON POSITION.
NOTE: PADLOCK AND 2ND CAR OPERATION ARE FEATURES THAT REQUIRE SPECIAL
PROGRAMMING.
SOME FEATURES MAY NOT BE AVAILABLE FOR ALL APPLICATIONS. CONTACT YOUR
DEALER FOR MORE INFORMATION.
technical support: [email protected]