Uniq UP-600CL-12B User manual

UP-600CL-12B
Digital CCD Camera
User's Manual
091-0602 V.1.3
08-09-17

1
Table of Contents
Warning.................................................................................................................2
Precautions............................................................................................................2
Limited Warranty ...................................................................................................2
1. Introduction.......................................................................................................3
2. CameraSetup.....................................................................................................5
3. CameraFunctions..............................................................................................5
4. RS-232C Communication Control ...........................…........................................9
5. Digital InterfaceTiming.....................................................................................10
6. CameraFunctional Timing.................................................................................11
7. CameraAccessories……………….............…..........................................................13
8. Technical Support ..............................................................................................13

2
WARNING
TOPREVENT FIREOR ELECTRIC SHOCK HAZARD,
DO NOTEXPOSE THIS CAMERAUNITTORAIN ORMOISTURE.
DO NOTATTEMPT TOREMOVE CAMERACOVER ORMODIFYTHECAMERAUNIT,
WARRANTY WILLBEVOIDED.
PRECAUTIONS
Do dotattempt to disassemble, modify, orrepair thecamera.ContactUNIQforhelp.
Do notpointthecameraatbrightobjects,such as thesun,foralongperiod.It may
causeCCDbloomingandpermanentdamages.
Do notoperate thecamerabeyondthetemperature range.Avoidusingthecamera
above 90% humidity.
Do notuseunregulated power supplysource.
Do nottouch CCDglass cover with fingersoranyhard objectsotherthan professional
glass cleaningsolvents.
Limited Warranty
UNIQ warrantstotheoriginal customer to befree fromdefectsin material and
workmanshipfortwofullyearsfromthedate oforiginal purchase. Thiswarranty covers
failures ordamagesdueto defects in material orworkmanship, whichoccurduring
normaluse. It doesnotcover damagesorfailures,whichresultfromshipment,
mishandling,abuse, misuse, ormodification.
AReturnMaterial Authorization(RMA)number isrequired priortoreturninganyUNIQ
productforrepair orreplacement.
Thisproprietary documentmaynotbe reproduced orphotocopied withouttheconsentof
UNIQ.UNIQ makesno warrantyorassumesno responsibility foranyerrors, which may
appearin thisdocument. UNIQreservestherightto make changeswithoutnoticeor
obligation.
Forimmediate technical assistance, pleasecall (408)330-0818 oremail to
tech@uniqvision.com

3
1. Introduction
1.1 General Description
The UP-600CL-12Bisa12-bit digitalCCD camerausing progressive scan sensor.This compact
and lightweight cameraoffersexcellent signalto noise performance. This high performance digital
cameraisidealfor high dynamicrange,lownoiseapplications.
1.2 Features
•1/3” Progressive scan CCD imager
•659 x494 active pixels
•12-bitRS-644 (LVDS)/CameraLink digitaloutput
•Fullframe shutter (1/60 ~1/62,000 sec.)
•<65 dB
•Asynchronous capture
•60 Hzframe rate (120Hz vertical binning)
•25 MHz data clock
•Long-termframe integration
•Externalexposurecontrol
•RS232C interface control
•C-mountlens
1.3 Applications
UP-600CL-12B applications include high-speed machine vision, automated inspection, motion
captureand analysis, and otherindustrialapplications.
1.4 CCD Imager Spectral ResponseCurve

4
1.5 Camera Specifications
Model
UP-600CL-12B
CCD Sensor 1/3”HyperHAD progressive scan interline-transferCCD
Chip Size 5.79 mm x 4.89 mm
Effective Pixels (H x V) 659 x494
UnitCell Size (H x V) 7.4 µm x7.4 µm
Pixel Clock 25 MHz (50 MHz for masterclock)
Frame Rate 60 FPS (120 FPS Verticalbinning)
Sync. HD: 31.485KHz; VD: 59.972 Hz
Digital Video Output Camera Linkformat
Analog Video Output 1 V p-p, 75ohm (BNC or12 pin Hirose)
S/N Ratio <65 dB
Min.Illumination 0.2 lux
Gain MGC
Gamma 1.0
Electronic Shutter 1/60 ~ 1/62,000 selectable 16 steps
Lens Mount C-Mount
Operating Temperature -10 °C ∼+50 °C
Power Requirement 12V DC, 250mA, 3.0W
Dimension 50mm x39mm x83mm
Ext. Sync. Internal/ExternalAuto Switch
Async Reset Standard
Weight 200 g
1.6 Camera Dimension

5
2. Camera Setup
Abasiccameraand frame grabber system setup,as showninFigure1below,requiresaUP-
600CL-12Bcamera,astandardC-mount lens, aPS-12C power supplyor equivalent, aPC system
and aVGA monitor,aframe grabber,and an externaltrigger deviceif necessary.
Figure1. Cameraand Frame GrabberSystem Setup
3. Camera Functions
3.1 12-Pin Connector
The 12-pin Hirose connector is located onthe
rear panelof the camera. All ground signals
onpin1, 3, 5, and 8arecommongrounds.
+12 VDC input isrecommended onpin2, but
thiscamerashouldwithstand +12 V ±1V
input voltage. Make sureto set the NM/AM
switch toNM positionforexternalHD and VD
locking. Figure2belowshows atopview of
the 12-pinHirose connector.
PinNo. UP-600CL-12B
1 GND
2 +12VDC input
3 GND
4 Video
5 GND
6 N/C
7 N/C
8 GND
9 N/C
10 N/C
11 Integrationcontrol
12 N/C
Figure2. 12-Pin Hirose Connector

6
3.2 Mode Switches Selection
Designation:
NS-Functionalselect
DS-Shutter speed select
NR- RS-232C communication Enable
RI-Rear switch control Enable
NP- Reserved forcustomoptions
PS- Reserved forcustomoptions
NM-Normalmode
AM-Asynchronous mode
Timing detailsof themode switches areshown insection6.
3.3 Shutter Speed Dial Switch
Shutter speed dial switch islocated onthe rearpaneland thereare16 different positions. To
select cameragain,reference, or tosave auser page, setNS/DS switch to NSposition.To adjust
shutter speed, set NS/DS to DS position. For normalshutter speed, make sureto set NM/AM mode
to NM location. For asynchronous capture, set NM/AMmode to AM location.
Position No. Functional Select
(NS) ShutterSpeedSelect (DS)
Normal Speed Double Speed
Shutter
Speed (sec)
(NM Mode)
Asynchronous
Capture (sec)
(AM Mode)
Shutter
Speed (sec)
(NM Mode)
Asynchronous
Capture (sec)
(AM Mode)
0 Normal 1/60 1/60 1/120 1/120
1 Gain Adjustment 1/125 1/250 1/250 1/250
2 Reference Adjustment 1/250 1/500 1/500 1/500
3 FactoryPage 1/500 1/1000 1/1000 1/1000
4 User Page 1 1/1000 1/2000 1/2000 1/2000
5 User Page 2 1/2000 1/4000 1/4000 1/4000
6 User Page 3 1/4000 1/5000 1/5000 1/5000
7 User Page 4 1/5000 1/6000 1/6000 1/6000
8 Normal/Double Speed 1/6000 1/8000 1/8000 1/8000
9 Reserved 1/8000 1/10000 1/9000 1/10000
A Reserved 1/10000 1/12000 1/10000 1/12000
B Reserved 1/12500 1/15000 1/12500 1/15000
C Reserved 1/15000 1/20000 1/15000 1/20000
D Reserved 1/20000 1/31000 1/20000 1/31000
E Reserved 1/31000 1/62000 1/31000 1/62000
F Reserved 1/62000 Pulse Width
Control 1/62000 Pulse Width
Control
Figure 4.Shutter Speed Dial Switch
Figure 3. Mode switches

7
3.4 Momentary Switch (UP/Down Switch)
Position
No. Functional Select (NS) Up/Down Switch
0 Normal N/A
1 Gain Adjustment Move up or down toadjust gain
2 Reference Adjustment Move up or down toadjust reference
3 FactoryPage Move up or down torecall factorypage
4 User Page 1 Up: Recall;Down: Save
5 User Page 2 Up: Recall;Down: Save
6 User Page 3 Up: Recall;Down: Save
7 User Page 4 Up: Recall;Down: Save
8 Normal speed/Double speedUp: Normal speed; Down: Double speed
9 Reserved
A Reserved
B Reserved
C Reserved
D Reserved
E Reserved
F Reserved
Camerasettings canbe savedinto four differentuser pages. Once the user page issaved and set
between shutter speeds 4and7, itwillbe activated as long as the camerais powered ON. User
Page works inboth rearplatecontroland RS232C communicationselections.
3.5 Gain Control (AGC/MGC)
Manual gain control (MGC)
MGC isstandardfactorysetting onthis
camera. The manual gaincontrolcan be
adjusted from9dB to 18 dB onlydue to the
factorydefaultsetting of AGC and AGC MAX
control.Adjusting the gainpotentiometer
located onrear panel,infigure6, will change
the gainvalue.
Automaticgain control (AGC):
AGC isnotavailable and itisnot
recommended to use by UNIQ.
Contact UNIQfor further details
Figure 6. AGC Control Characteristics
Figure5. Up/Down Switch

8
3.6 26-Pin Camera Link Connector
PIN NO. CAMERA LINK
SYMBOL UNIQ CAMERA
SYMBOL FUNCTION
1, 14 INNER SHIELD SHIELD Inner shielding
2, 15 X0-,X0+ DATA0-,DATA0+
Video,LEN and FEN data output
3, 16 X1-,X1+ DATA1-,DATA1+
Video,LEN and FEN data output
4, 17 X2-,X2+ DATA2-,DATA2+
Video,LEN and FEN data output
5, 18 Xclk-,Xclk+ CLK-,CLK+ Pixel clockoutput
6, 19 X3-,X3+ DATA3-,DATA3+
Video,LEN and FEN data output
7, 20 SerTC+,SerTC- Rx+,Rx- Differential pair,serialcommunications from frame
grabber
8, 21 SerTFG-,SerTFG+Tx-,Tx+ Differential pair,serialcommunications to frame
grabber
9, 22 CC1-,CC1+ HD-,HD+ Camera Control 1(CC1) - Horizontal signal input
10,23 CC2+,CC2- VINT/VD+,
VINT/VD- Camera Control 2(CC2) - Vertical signal or
asynchronous reset input
11,24 CC3-,CC3+ Reserved Reserved for custom options
12,25 CC4+,CC4- Reserved Reserved for custom options
13,26 INNNER SHIELD SHIELD Inner shielding
Figure8. 3M 26-pinCameraLink Connector (MDR-26 pin)

9
4. RS-232C Communication Control
UNIQ doesnotprovide its own softwareprogramfor RS232C communication, contact frame
grabber vendor or UNIQ for further details.
Command Command Name Notes
? Error “?” Error will appear on screen if incorrect command isentered
ru# Recall userpage Must have a number after “ru” such as 1, 2,3or 4
rp Report current
camera setting G= Gain; R = Reference
S = Shutter Mode; NS,NM (refer to rear plate setting)
rf Recall factory
setting page Factorydefault setting
sm# Shutter mode Must have a number after sm (1~ f),referto section 3.3for details.
sp# Save user page There are 4user page available
ns Normal speed Refer to camera specifications
ds Double speed Refer to camera specifications
nm Normal mode Normal free running
am Asynchronous modeAsynchronous reset
gi### Gain increase ### = Hexadecimals(000~ 3ff).If nonumber entered,gain will be
increased byfactor of 1. If a number is entered,thennumber will be
added tostored gain.
gd### Gain decrease ### = Hexadecimals(000~ 3ff).
Same as giabove,except it will be decreased.
gn### Gain number ### = Hexadecimals(000~ 3ff).Refer tothe gain curves below for
details.
bi### Reference increase ### = Hexadecimals(000~ 3ff).If nonumber entered,reference
willbe increased byfactor of 1.If anumber is entered,then number
willbe added to stored reference.
Note: It’sveryuncommon to change reference level,contact UNIQ for
further details.
bd### Reference decrease
bn### Reference number
Note:
1. Command must be in “lowercase.”
2. Allnumbershave tobe in“hex” format, use aPC calculator to convertbetween hex and
decimal numbersifnecessary.
3. Command example:
UserEnters: “sm5” (shutter speed at 5)
Camerareturns: “?” or “3f”in Hex
(incorrectanswer,no RS232C communicationor something’s wrong)
or
Camerareturn: “ ”or “1” inHex (correct answer,itmight showother
symbolsdepending onPC system)
4. Gain Curves:
Figure9. CameraGainCurve

10
5. Digital InterfaceTiming
5.1 Pixel Clock
5.2 Line Enable
5.3 Frame Enable
5.4 Frame Enable for Vertical Binning
Note:
1. Pixelclock=25MHz
2. 1N=40 nsec.
3. 1H=793N

11
6. Camera Functional Timing
6.1 Free Run (shutter speedposition 0, 60 fps)
6.2 Free Run (shutter speed position from 1 to F)
6.3 Asynchronous Capture (shutter speed position 0)
6.4 Asynchronous Capture (shutter speed position from 1 to E)
6.5 Asynchronous Capture with Pulse Width Control (shutter speed:F)

12
6.6 External Synchronization and Gen-lock (viaCameraLinkinterfaceONLY)
The UP-600CL-12Bcameraautomaticallylocksto the externalsync source. The externalsync
source must match the cameraHD and VD specification, which are31.49KHz and 59.97Hz
respectively. BothexternalHD and VD areTTLlevelsignals.
a) HD
H: 2.5V to 5V
L:0V or GND
Pulse width:5-50% duty cycle, see figure8shown below.
b) VD
H: 2.5V to 5V
L:0V or GND
Pulse width:0.5-50% duty cycles
Figure10.ExternalSynchronizationandGen-lockTiming
6.7 Integration (via12-pin HiroseconnectorONLY)
The UP-600CL-12Bcameracan be integrated up to 2seconds without severenoise ordarkcurrent
effect. Tostartintegration, pin#11 (same as pin #27 of 40-pindigital connector)of the 12-pin
connectormust be connected to GND or 0V. The integrated video will be shifted out following the
next vertical drive after pin#11 goesback to high or 5V level,as shown infigure9below. If a
frame grabber does notcapturethe immediate frame orintegrated video,the normal video(before
the integration) will display againonthe monitor.
Figure11.IntegrationControl Timing

13
7. Camera accessories
7.1 Power Supply and Power Cable
12 VDC regulated power supplywith 1A current output or betterisrecommended. Thiscamera
uses Hirose 12-pinconnectorforpower source. The matting cable plug connector can be
purchased through distributorsor UNIQ and the Hirose partnumberis HR10A10P12S.UNIQ
provides power suppliesand power cables as"one stopshopping"forcustomers. Alternatively,the
power suppliesand power cables can be purchased through power supplyand cablevendors.
Contact UNIQfor vendor list.
7.2 Lens
C-mountlens isthe standardlens for UP-600CL-12B camera. Thereareavarietyof C-mount
lenses inthe market that workswith UP-600CL-12B camera. Makesurethequalityand
specificationof the lens matchthe camera's application. Some of themost popularlenses inthe
market, such as Cosmicar, Fujinon,Rodenstock, andSchneider,arerecommended.
7.3 Camera Link Cable
CameraLink cablecan be purchased from3M, Mouser,Digi-Key and frame grabber vendors.
8. Technical Support Information
For technical assistance, contact UNIQTechnicalSupportor Applications Engineer at
Phone: (408) 330-0818
Fax: (408) 330-0886
Email:info@uniqvision.com
Company contactinformation:
UNIQ VISION, INC.
2924 ScottBlvd.
Santa Clara, CA 95054
Phone: (408) 330-0818
Fax: (408) 330-0886
Our website: www.uniqvision.com
General Inquiries: info@uniqvision.com
Table of contents
Other Uniq Digital Camera manuals