usha CD503 User manual

Model - CD503
Power rating: 190 Watts
Voltage rating: 230 Volt, 50Hz
Portable Evaporative Air Cooler
OWNER’S MANUAL
Read and save these instructions before use
INSTRUCTION MANUAL
MAXX AIR DESERT COOLER

2
QUICK START GUIDE
Fill the tank with water and plug the cooler in
standard power outlet socket.
Note: Please make sure the household power
voltage matches the product specifications.
Place near an open door or window.
Note: Evaporative air cooler requires cross
ventilation.
Turn ON and enjoy the cooling breeze.
Note: Start with low speed and gradually
increase to higher speed for optimum cooling
performance.

3
Read all instructions carefully before setting up and operating the cooler, and
please keep this instruction manual for future reference. This manual is designed
to provide you with important information needed to setup, operate, maintain, and
troubleshoot your cooler. Failure to follow these instructions may damage and/or
impair its operation and void the warranty
SECTION PAGE
Thank You 4
User Tips 5
Safety 7
Parts Description 9
Uses & Operation 10
Control Panel 10
Control Knobs 11
Filling Water 12
Cleaning & Maintenance 14
Troubleshooting Guide 16
Technical Specifications 17
Electrical Wiring Diagram 17
Service And Warranty 18
INDEX

4
THANK YOU
Congratulations on your purchase of this versatile USHA Evaporative Air Cooler.
For optimum cooling from your cooler, fill the water tank to maximum level before
you turn on your air cooler.
Cooler Location (Important - Please Read!)
Place the cooler in front of an open door or window. Ensure that there is adequate
cross -ventilation in the room by leaving a door or window open opposite the
cooler. Following these guideline will ensure your cooler will work as effectively as
possible. Keep distance of minimum 0.5 meters from the wall.
Not an Air Conditioner (Important - Please Read!)
The evaporative air cooler is not an air conditioner as it does not use a compressor
or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated
air conditioner

5
USER TIPS
Energy efficient, No compressor
USHA Evaporative Air Coolers are built to maximize energy efficiency and keep
costs low. Warm air is drawn into the cooler through the Honeycomb Cooling
Media. Water pumped from the tank pours over the honeycomb media. As the
warm air passes through the media, the water absorbs the heat, naturally cooling
and humidifying the air. A fan propels the cooled air out into the room. This no-
compressor system cools naturally, efficiently and inexpensively.
Warm and
dry air
Cool and
humid air
PUMP
Water
Fan
Honeycomb cooling media
Evaporative Air Cooling Mechanism

6
The recommended maximum relative humidity
level is 60% or less, which allows a noticeable
temperature decrease. The temperature
decrease will be greater in drier climates
because higher evaporation occurs when the
humidity is low.
The evaporative air cooler should not be used
in enclosed spaces. It must be kept level and
there must be water in the water tank. The
room should have doors and windows opened
to allow free air flow. The evaporative air cooler
works best when placed near an open window,
so that outside air is drawn into the evaporative
air cooler, the air circulates in the room, then
exits via the door. The maximum cooling effect
is felt when a person is in the flow of air coming
out of the evaporative air cooler.
NOTE
When the product is used for the first time the
Honeycomb cooling media will have an odor
which will dissipate in a week or so of initial use
USER TIPS
Room with open windows & door
(RECOMMENDED)
Room with closed windows &
door ( NOT-RECOMMENDED)

7
SAFETY
READ AND SAVE THESE INSTRUCTIONS:
When using electrical appliances, basic safety
precautions should always be followed:
• Yourcoolerrunson230VoltAC,50Hz.Check
the household voltage to ensure it matches the
appliance’s rated specification.
• Beforeoperatingtheproductremoveitfromits
packaging and check that it is in good condition.
• DONOToperateanyproductwithadamagedcord
or plug. We recommend not using an extension
cord with this appliance.
• DONOTrunpowercordundercarpeting,orcover
it with rugs or runners. Keep the cord away from
areas where it may be tripped over.
• Alwaysunplugtheproductbeforerefillingthewater
tank.
• Alwaysunplugtheappliancefromthepowersource
before cleaning, servicing or relocating the unit.
• Removethepowercordfromtheelectrical
receptacle by grasping and pulling on the power
cord plug-end only, never pull the cord.
• DONOTusetheproductinareaswheregasoline,
paint or other flammable goods and objects are
stored.
• Whenusingthe‘’COOL’’setting,checkthewater
tank to ensure that it is full. Operation of this cooler
onthe‘’COOL’‘settingwithanemptytankmay
result in damage to the water pump.
• DONOTattempttorepairoradjustanyelectricalor
mechanical functions of the cooler, as this may void
the warranty.
STOCK HAZARD
230 Volt AC 50 Hz
WATERLEVELINDICATOR

8
• DONOTcovertheairinletoroutletonthe
appliance as this may cause motor damage.
• DONOTinsertorallowobjectstoenterany
ventilation or exhaust opening as this may
damage the product and could cause an
electrical shock or fire.
• DONOToperatewiththeHoneycombmedia
removed as this will overload and damage the
motor.
• DONOTleavetheoperatingappliance
unattended for an extended period of time.
• DONOTletchildrenplaywiththisappliance,
packaging or plastic bags.
• Iftheunitisdamagedoritmalfunctions,
do not continue to operate it. Refer to the
troubleshooting section and seek professional
advice.
• Placetheunitonalevelfloor.Thisproductisnot
intended for use in wet or damp locations.
• DONOTuseinbathrooms.Neverlocatethe
product where it may fall into a water container.
• Storeinadryareawhennotinuse.This
appliance is not intended for use by persons
(including children or elderly) with reduced
physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have
been given supervision or instruction concerning
use of the appliance by a person responsible for
their safety.
• Alwaysgripthesidehandlestomovethecooler.
SAFETY
FIRE TOUCH
COOLERFLOORSETTING
FloorLevel

9
PARTS DESCRIPTION
1 Handle
2 LeftHoneycombPanel
3 LeverforHorizontalLouvers
4 Water Tank
5 Castors
6 HorizontalLouvers
7 WaterLevelIndicator
8 Mechanical Control Panel
9 BackHoneycombPanel
10 Water Drain Plug
11 Continuous Water Inlet
12 Rear Grill Removal Screws
13 Manual water filling through mug
14 Manual water filling through pipe
11
14
12
9
10
13
7
8
1
2
4
5
6
3

10
CONTROL KNOBS
Speed/ ON- OFF
Connect to the power supply and turn the SPEED
knob.Thefanwillstart.Changethespeedfrom“Low”
forLowspeed,to“Medium”forMediumspeedandto
“High”forHighspeed.ToswitchtheunitOFF,turnthe
SPEEDknobto“0”.
COOL
TurntheCOOLknobtoONtostartthecooling.It
takes a few minutes to obtain the full effect from this
mode.
SWING
Vertical Louvers
TurntheSWINGknobto‘ON’.Thelouverswillbegin
to move from right to left automatically.
CONTROL PANEL
USE & OPERATION
SWING FAN
PUMP
SWING
FAN
PUMP
Table of contents
Other usha Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual