usha CO48PM User manual

CL48PM / CO48PM
OFF
COOL
ON
OFF
ON
0
3
2
1
SPEED SWING
MAX
MIN
www.honeywellaircoolers.com
www.jmatek.com
E-mail: [email protected]
Model:
Scan here:
Portable Evaporative Air Cooler
User Manual
Read and save these instructions before use

(10)
(11)
(16)
(12)
(13)
(14)
(15)
OFF
COOL
ON
OFF
ON
0
3
2
1
SPEED SWING
(1)
(2)
(9)
(8)
(3)
(4)
(5)
(6)
(7)
(17)
7) Louvers
8) Water Level Indicator
9) Control Panel
10) Right Side Grill
11) Water Inlet Valve
12) Drain Plug
13) Rear Grill
14) Power Cord & Plug
15) Rear Grill Screws
16) Water Fill Door
17) Honeycomb Cooling Media
PARTS DESCRIPTION
USE & OPERATION
CONTROL PANEL
FUNCTION BUTTONS
SPEED / ON - OFF
Connect to the power supply and turn the SPEED knob. The fan will start. Change the speed from 3 to
1 (1 for Low, 2 for Medium and 3 for High fan speed). To switch OFF the unit, turn the SPEED knob to 0.
1) Water Inlet Hole
2) Handle
3) Left Side Grill
4) Lever for Horizontal Louvers
5) Water Tank
6) Casters
WARNING -- READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER
MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE IS
ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER
LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL
PREVAIL.
WARNING: FOR OUTDOOR MODEL CO48PM, USE ONLY ON GFCI PROTECTED RECEPTACLES.
SWING SPEED COOL
OFF
ON
ON
OFF
0
3
2
1
EN 1

USE & OPERATION (CONTINUED)
Water Inlet Hole
Water Fill Door Ice Loading
Compartment
Water inlet valve
Garden Hose
FILLING WITH WATER
COOLER LOCATION
It is ideal to use the Continuous Water Supply Connection to run the unit for long periods of time without
refilling the tank. This also helps prevent pump failure in case the cooler is running with inadequate water
in the tank.
CAUTION: Unplug the unit from the electrical power outlet before filling or emptying the water tank.
Make sure to position the air cooler correctly before you set up and start using the product. Please refer
to the COOLER LOCATION section of the separate Safety & Maintenance Guide.
Locate the male connector at one end of the garden hose. Insert the
garden hose connector into the water inlet valve of the cooler. Screw
and tighten the water inlet valve onto the threaded part of the garden
hose connector, making sure the hose connector is secured to
ensure there will be no leaks. If there is leakage, the hose and the
water inlet valve may not be connected properly. Try to disconnect,
replace and tighten the water inlet valve again.
When the connection is secured, turn ON the water supply and the
water will flow into the water tank of the cooler.
The cooler is now set so the water refills automatically when the
water tank is empty, or when the water reaches below a minimum
level.
When the water tank is full, the water inlet valve will automatically
stop the water supply from overflowing.
Please open the water valve for minimum flow as too much pressure
could damage the inlet pressure control system.
WARNING: The maximum water inlet pressure is 0.5 MPa.
t
t
t
t
t
Continuous Water Supply Connection:
For a continuous water supply, you will need a garden hose that is
connected to a main water supply.
EN 2
FUNCTION BUTTONS (CONTINUED)
COOL
You must add water before operating the unit on Cool mode. Turn the COOL knob to the ON position to
activate evaporative cooling. The water pump will operate and you will feel the cooler air after the
Honeycomb Cooling Media is completely wet.
SWING
Turn the SWING knob to the ON position to activate the movement of the louvers. The louvers will begin
to move left to right automatically. Vertical Air Flow - You can manually adjust the lever located at the
front of the unit to change vertical air flow.

USE & OPERATION (CONTINUED)
EN 3
Move the unit to a location where the water can be drained. Remove the cap from the Drain plug
located at the bottom of the unit. Allow the tank to empty.
Refill the water tank with clean water, up to the maximum level and drain it completely.
Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive
elements or chemicals to clean this product.
When the product is not in use, store the unit in a dry place away from direct sunlight.
t
t
t
t
CLEANING & DRAINING THE WATER TANK
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the electrical socket.
If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE
GUIDELINES located in the separate Safety & Maintenance Guide.
WARNING: Always ensure the water in the water tank is above the minimum (Min.) water level mark for
both Continuous & Manual Water Refill. Running the unit in Cool mode with inadequate water may
cause pump failure.
WARNING: Do not fill water tank with dirty water or salt water. This can damage the unit and
Honeycomb media.
Note: The water capacity refers to the total volume of water that can be contained within the air cooler
water tank and water distribution system. The water capacity in the tank at the “Max.” indicator level
may be lower than the actual water capacity of the air cooler.
Using a portable container or a garden hose, you can refill the water tank manually by pouring water
into the water tank through the water inlet hole located at the top of the air cooler.
Check the water level indicator to know when the water tank is full. Do not fill water above the "Max."
water level mark to avoid water droplets collecting on the louvers.
t
t
Manual Water Tank Refill:
FILLING WITH WATER (CONTINUED)
The appliance is supplied with three Honeycomb Cooling Media pads.
The Honeycomb Cooling Media are located inside the Rear and Side Grills. Follow Steps 1 to 5 for
instructions on how to remove them from the unit for cleaning and maintenance.
Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and
refill with fresh water, especially if the tank has not been cleaned in a long time.
t
t
t
CLEANING THE HONEYCOMB COOLING MEDIA

USE & OPERATION (CONTINUED)
Remove the screws from the Rear Grill of the Air Cooler.
Carefully pull out the Rear Grill from the Air Cooler.
The Honeycomb Cooling Pad is secured on the Rear Grill by two Horizontal Bars that are fixed in
place by two screws on the Left and Right Sides of these Horizontal Bars. Remove these screws to
release the Horizontal Bars.
Pull out the Honeycomb Cooling Pad by sliding it out from the Rear Grill. Replace with the new
Honeycomb Cooling Pad by sliding into the grooves of the Rear Grill until it fits comfortably and
securely in place on the grill. Replace the Horizontal Bars back onto the Rear Grill by replacing the Left
and Right Side screws and tightening them in place. This secures the Honeycomb Cooling Pad in
place on the Rear Grill.
Repeat steps 1 to 4 to remove the Honeycomb Cooling Pad on the Left and Right Side Grills.
WARNING: DO NOT operate the Air Cooler when any or all of the Rear or Side Grills are removed
from the Air Cooler, or if there is a loose-fitting Rear or Side Grill. Doing so can cause serious injury or
dangerous electrical shock.
1.
2.
3.
4.
5.
Removing the Honeycomb Cooling Media:
CLEANING THE HONEYCOMB COOLING MEDIA (CONTINUED)
The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas
where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling
Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week
will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the
media should be removed and washed under fresh water. The media should be cleaned every two
months or sooner, depending on your needs.
For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool
function 15 minutes before turning the unit off.
t
t
Step 1:
Step 3: Step 4:
Step 2:
Rear
Honeycomb Pad
Rear Grill
Horizontal
Bars
Screws
Rear
Honeycomb Pad
Rear Grill
Rear Grill
Screws
Rear Grill
EN 4
This manual suits for next models
2
Table of contents
Other usha Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu ASYG 09 LLCA installation manual

York
York HVHC 07-12DS Installation & owner's manual

Carrier
Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity
intensity IDUFCI60KC-3 installation manual

Frigidaire
Frigidaire FAC064K7A2 Factory parts catalog

Sanyo
Sanyo KS2432 instruction manual

Mitsubishi Electric
Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic
Panasonic CS-S18HKQ Service manual

Panasonic
Panasonic CS-E15NKE3 operating instructions

Gree
Gree GWH18TC-K3DNA1B/I Service manual

Friedrich
Friedrich ZoneAire Compact P08SA owner's manual

Daikin
Daikin R32 Split Series installation manual