Introduction | Rev 0418.1
NOTES:

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Introduction
3
Table of Contents
1 Introduction.................................................................................................................................................................................................... 6
1.1 System Overview .................................................................................................................................................................................6
1.2 Specifications.......................................................................................................................................................................................7
1.3 Installation...........................................................................................................................................................................................8
1.4 Monitor and Power Connections (Harness 647103)............................................................................................................................8
1.5 VM-5500 Console Main Harness (Harness 647117).............................................................................................................................9
1.6 Internal GPS.........................................................................................................................................................................................9
2 Quick Start.................................................................................................................................................................................................... 10
2.1 Entering Setup Assistant....................................................................................................................................................................10
2.2 Setup Assistant Features ...................................................................................................................................................................10
2.3 Quick Start Screens............................................................................................................................................................................ 11
2.3.1 Implement Sensor Select ........................................................................................................................................................11
2.3.2 Implement Type Select ...........................................................................................................................................................12
2.3.3 Implement Row, Spacing and Width settings .........................................................................................................................12
2.3.4 Display Assignments ...............................................................................................................................................................14
2.3.5 Section Assignments ...............................................................................................................................................................14
2.3.6 Product Sensor “Seeds” .......................................................................................................................................................... 15
2.3.7 Product Sensor “Flow”............................................................................................................................................................16
2.4 Exiting Quick Setup (Setup Assistant) ................................................................................................................................................17
2.4.1 Exit Finish................................................................................................................................................................................ 17
2.4.2 Exit Early .................................................................................................................................................................................17
2.4.3 Not Finished ??? .....................................................................................................................................................................17
3 Optional Setup..............................................................................................................................................................................................18
3.1 Extra Product Sensor Configurations .................................................................................................................................................18
3.1.1 Implement Page Options ........................................................................................................................................................18
3.1.2 Area Monitor Setup ................................................................................................................................................................19
3.1.3 Manual Harness Assignment................................................................................................................................................... 19
3.1.4 Section Control ....................................................................................................................................................................... 20
3.2 Accessory Sensors..............................................................................................................................................................................21
3.2.1 RPM Shaft ...............................................................................................................................................................................22
3.2.2 VAC/Pressure Sensor Setup ....................................................................................................................................................22
3.2.3 Lift Switch Configuration......................................................................................................................................................... 25
3.2.4 Hopper Type Sensor Setup...................................................................................................................................................... 25
3.3 User Interface Setup.......................................................................................................................................................................... 26
3.3.1 Alarm Setup ............................................................................................................................................................................26
3.3.2 Display Settings....................................................................................................................................................................... 26
3.3.3 Misc. Settings.......................................................................................................................................................................... 27
3.3.4 Speed Setup............................................................................................................................................................................27
3.3.5 Speed Calibration....................................................................................................................................................................28

VM-5500 Operator’s Manual
2018
4
Introduction | Rev 0418.1
3.4 Setup Screen...................................................................................................................................................................................... 29
4 Monitor Operation Screens ..........................................................................................................................................................................30
4.1 Menu Bar...........................................................................................................................................................................................31
4.1.1 Screen Navigation ...................................................................................................................................................................31
4.1.2 Alarm Message Area...............................................................................................................................................................31
4.1.3 Speed Icon ..............................................................................................................................................................................31
4.1.4 Manual Speed......................................................................................................................................................................... 32
4.2 Home Screen .....................................................................................................................................................................................32
4.2.1 Console Area...........................................................................................................................................................................32
4.2.2 Bar Graph Area .......................................................................................................................................................................34
4.3 Seed Dash Board................................................................................................................................................................................35
4.3.1 Population and Spacing........................................................................................................................................................... 35
4.3.2 Acre Counters .........................................................................................................................................................................35
4.3.3 Acre/Hr and Singulation.......................................................................................................................................................... 35
4.3.4 Accessory Sensor Tiles ............................................................................................................................................................36
4.4 Flow Dash Board................................................................................................................................................................................ 36
4.5 Singulation Screen .............................................................................................................................................................................37
4.6 Area Monitor .....................................................................................................................................................................................38
Internal GPS Status .................................................................................................................................................................39Appendix A
Flow Meters............................................................................................................................................................................ 40Appendix B
Flow Meter Installation...................................................................................................................................................................... 40B.1
Master Flow....................................................................................................................................................................................... 43B.2
Post Season Storage for the Vanguard Visu-FloTM Flow Meters.........................................................................................................44B.3
VM5500 Console Pinouts........................................................................................................................................................45Appendix C
30 Pin Console Pinout........................................................................................................................................................................45C.1
18 Pin Console Pinout........................................................................................................................................................................45C.2
4 Pin Power In/ Alarm Out Pinout...................................................................................................................................................... 45C.3
4 Pin Bottom Speed In Pinout (Radar/Speed).................................................................................................................................... 45C.4
VM-5500 Implement Pinouts..................................................................................................................................................46Appendix D
37 Pin Harness Pinout........................................................................................................................................................................ 46D.1
Part Numbers.......................................................................................................................................................................... 47Appendix E
Monitor.............................................................................................................................................................................................. 47
E.1
Implement Harnesses and Cables
.................................................................................................................................................... 47E.2
ConsoleHarnesses
............................................................................................................................................................................ 47E.3
Visu-FloTM Parts and Accessories .......................................................................................................................................................48E.4
E.4.1 Flowmeters .............................................................................................................................................................................48
E.4.2 Flowmeter Bracket.................................................................................................................................................................. 48
E.4.3 Visu-FloTM Harness ..................................................................................................................................................................48
E.4.4 Y Cables................................................................................................................................................................................... 48

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Introduction
5
Table of Figures
Figure 1 Monitor Mounting .............................................................................................................................................................. 8
Figure 2 Setup Assistant Region explanation.................................................................................................................................. 10
Figure 3 Setup Assistant Start Page ................................................................................................................................................ 11
Figure 4 Implement Configuration Dialog....................................................................................................................................... 11
Figure 5 Implement Configuration with All Sensors ....................................................................................................................... 12
Figure 6 Row, Spacing and Width Setup ......................................................................................................................................... 13
Figure 7 Display Assignments Viewer ............................................................................................................................................. 14
Figure 8 Section Control ................................................................................................................................................................. 14
Figure 9 Product Sensor Setup for Seeds........................................................................................................................................ 15
Figure 10 Product Sensor Setup for Flow ½ .................................................................................................................................... 16
Figure 11 Area Monitor (No Sensors) Setup ................................................................................................................................... 19
Figure 12 Manual Harness Assignment Dialog................................................................................................................................ 20
Figure 13 Resulting Display Assignments........................................................................................................................................ 20
Figure 14 Section Control ............................................................................................................................................................... 21
Figure 15 Accessory Sensors........................................................................................................................................................... 21
Figure 16 RPM Sensor Setup........................................................................................................................................................... 22
Figure 17 VAC / Pressure Setup Screen .......................................................................................................................................... 22
Figure 18 VAC / Pressure Sensor Select .......................................................................................................................................... 23
Figure 19 Zero Pressure Calibration Start ....................................................................................................................................... 24
Figure 20 Zero Press Calibration Processing ................................................................................................................................... 24
Figure 21 Lift Switch Setup Screen.................................................................................................................................................. 25
Figure 22 Hopper Setup Screen ...................................................................................................................................................... 25
Figure 23 Alarm Setup .................................................................................................................................................................... 26
Figure 24 Display Settings............................................................................................................................................................... 26
Figure 25 Misc. Settings .................................................................................................................................................................. 27
Figure 26 Speed Setup .................................................................................................................................................................... 27
Figure 27 Speed Calibration............................................................................................................................................................ 28
Figure 28 Speed Calibration "End".................................................................................................................................................. 28
Figure 29 Setup Screen ................................................................................................................................................................... 29
Figure 30 Home Screen Layout ....................................................................................................................................................... 32
Figure 31 Home Console Area ........................................................................................................................................................ 32
Figure 32 Home Console Sensor Select........................................................................................................................................... 32
Figure 33 Individual Parameter Selection....................................................................................................................................... 33
Figure 34 Home Bar Graph Area..................................................................................................................................................... 34
Figure 35 Bar Graph Examples........................................................................................................................................................ 34
Figure 36 Seed Dash Board ............................................................................................................................................................. 35
Figure 37 Seed Dash Optional Tiles................................................................................................................................................. 36
Figure 38 Flow Dash Board ............................................................................................................................................................. 36
Figure 39 Flow Dash Optional Tiles................................................................................................................................................. 37
Figure 40 Singulation Screen........................................................................................................................................................... 38
Figure 41 Speed/Area Monitor Screen ........................................................................................................................................... 38
Figure 42 Satellite Signal Strength .................................................................................................................................................. 39
Figure 43 GPS Lock Status............................................................................................................................................................... 39
Figure 44 Pluming Diagram............................................................................................................................................................. 41
Figure 45 Flow Manifold ................................................................................................................................................................. 43
Figure 46 Monitor Implement Type Selection ................................................................................................................................ 43
Figure 47 Monitor Implement Configuration.................................................................................................................................. 44

VM-5500 Operator’s Manual
2018
6
Introduction | Rev 0418.1
1Introduction
1.1 System Overview
The VM-5500 Planter Monitor is designed for maximum performance in the field and is easy to install
and use. The system is capable of monitoring up to 16 rows and provides not only seed population, but
also will display area, hopper level, RPM and vacuum information when sensors are connected, and has
capabilities of monitoring liquid flow with Vanguard “Visu-FloTM Technology”.
7” Color Touch Screen
VM-5500 1-16 Row Monitoring
Built in GPS Speed option
Bar graphs
Setup assist for easy programming
Adjustable accumulating time
RAM 1 1/2” Ball Mount
Adjustable Back light
Day/Night Mode
Adjustable Audible Alarm
Optional Visual Alarm Light
View Home or Dashboard
View Seed population or GPM
View 20 sec. Row History
Visu-FloTM Option
Optional Lift Switch
2 Hopper Level, 2 RPM, 2 Vac. Opt.
Section grouping
Scan for Additional Online Assistance

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Introduction
7
1.2 Specifications
Power
10–16 VDC, 3.5 A maximum
Operating temperature
range
-20°C to 70°C (-4°F to 158°F)
Storage temperature
range
-40°C to 85°C (-40°F to 185°F)
Size
27.30 cm W x 16.50 cm H x 5.08 cm
D
(10.75" W x 6.5" H x 2" D)
Weight
3.08 kg (6.8 lbs.) for 16-row
VM-5500
system
WireHarnesses
The
VM-5500
includes detachable
harnesses to supply the unit's power
(fused) and sensor inputs (to hitch).
Connectors on the back for GPS
Antenna, USB on Front, Radar on
Bottom
Sensors
Compatible with Vanguard and other
major brands of seed sensors.
Standardmounting
RAM Mount 1
½
” Ball Mounting
Alarm adjustment
Four levels audible alarm with mute
onscreen selection. Optional external
light available.
Backlight adjustment
Five increments plus Day/Night
mode
SAFETY NOTICES

VM-5500 Operator’s Manual
2018
8
Introduction | Rev 0418.1
1.3 Installation
Your VM-5500 comes with a RAM 1 ½” Mounting Ball. Any RAM Mount 1 ½” fixtures will adapt to your
monitor.
Figure 1 Monitor Mounting
Install the RAM-238-U 1 ½” Ball supplied with your console by removing the two screws from the rear of
the unit and use them to attach the ball.
Any RAM configuration may be used to attach your console to a convenient location in your cab. If you
need a base mount, see the above for more options. See your local dealer for brackets and arms that
are available, or visit www.agdirectusa.com to purchase online.
1.4 Monitor and Power Connections (Harness 647103)
Route the power leads of the main harness to the battery. Allow some slack to tie the harness off to a
secure location in the cab to provide strain relief and for the protection of the harness.
The monitor operates on 12 VDC only. The red (Fused)
lead should be connected to the positive battery terminal
and the black lead should be connected to the negative
battery terminal.
There is a short two pin Deutsch connector at the monitor
end of the power cord. This is for connecting the
optional Visual Alarm Light (Part No. 647105)

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Introduction
9
1.5 VM-5500 Console Main Harness (Harness 647117)
Route the main harness to the rear of the tractor. Attach the connector to the bottom of the monitor
with a ¼” nut driver. Tie the harness securely in the cab as a strain relief.
The 647117 harness will attach to your planter or implement with a 37 pin AMP CPC style connector.
This connector is pinned to match standards used by Dickey-john, Agco, Kinze and many other
manufacturers. Be aware that Deere uses the same connector but uses a different wiring pattern. If
you are connecting to a Deere harness, you will need a 37D37J adapter for each harness available
online from www.agdirectusa.com.
If you are using an external speed source such as a radar or external GPS, connect it to the 4 pin AMP
connector on the bottom of the monitor. (Adapters are available for most common radar and GPS
connectors)
If you are using the internal GPS, attach the antenna to the coax connector on the back of the monitor.
Once your implement is connected, you are ready to operate your monitor.
1.6 Internal GPS
The VM-5500 can be purchased with the optional onboard GPS enabled, or it may be enabled by the
customer upon the purchase of a valid license.
The License may be obtained from your Vanguard dealer or by contacting our customer service
department. Once the transaction is complete, you will be provided with a license code to install on a
USB flash drive. Upon insertion into the USB port of the monitor, the license will install and enable the
onboard GPS.

VM-5500 Operator’s Manual
2018
10
Quick Start | Rev 0418.1
2Quick Start
The Quick Start feature of the Monitor is a method that will step you through a complete setup of your
monitor. This feature will insure proper configuration while providing you with a good working
knowledge of the parameters that need to be set for your implement.
This Quick Start section will discuss typical implement configurations, for more in depth configurations
or implements with Accessory Sensors please reference the Optional Step Up section that immediately
follows the Quick Start.
This Quick Start section uses your monitors Setup Assistant feature to walk you through configuring your
monitor. In the Setup Assistant you will be provided a list of parameters that need to be entered. Once
you have entered the required information a GREEN “Exit Finish” Button will appear, you are then ready
to Exit the Quick Start.
2.1 Entering Setup Assistant
The Setup Assistant feature is automatically entered when you power up your monitor for the first time.
If you have to leave the Setup Assistant early, don’t worry when you return you will come back into the
Setup Assistant to finish configuring you implement. At any time there after, you can re-enter this mode
using the Navigation Buttons at the top of the monitor. By pressing the “Setup” navigation button, the
“Setup” button will change to the “Setup Assist”, by pressing this button again you will re-enter the
Setup Assistant feature.
2.2 Setup Assistant Features
When in the Setup Assistant the Normal Navigation Buttons will change to 3 Control Buttons (Exit,
Previous and Next Buttons). An Instruction Area to the right of the Control Buttons will instruct you on
the next required parameters that are required prior to you advancing to the next Page. On the left side
of the screen you will see a list of the “Required Parameters Remaining”, if this area is empty you will be
allowed to proceed. The items in the list are also highlighted in RED on the main area of each screen.
Figure 2 Setup Assistant Region explanation
Control Buttons
Still Required
Launch Help
Attributes Still
Required
Implement
Selection
Instruction Area

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Quick Start
11
2.3 Quick Start Screens
Your Monitor is very configurable, however it is very easy to setup. We will walk you through a typical
Seed and Liquid Flow implement configuration. Don’t worry if this configuration is not exactly what you
have we will discuss more details in a later section.
The following screen is our starting page for the Setup Assistant.
Figure 3 Setup Assistant Start Page
2.3.1 Implement Sensor Select
By pressing the Red ? Button in the “Sensors on Row” column, the following dialog box will appear.
Figure 4 Implement Configuration Dialog
You have two options by selecting the “Sensors” check box at the top of the screen you may select your
implement Sensors. The “No Sensor” selection is discussed in the Optional Setup Section.
Sensor / No Sensor
Select

VM-5500 Operator’s Manual
2018
12
Quick Start | Rev 0418.1
2.3.2 Implement Type Select
Use the Check Boxes to select if your monitor is connected to seed sensors, flow meters or both. If you
select Flow 1, you may select Flow 2 as well if you are using two different flow rates on your
system. Keep in mind that you are limited to 16 total sensors on this monitor. Depending on your
selections the monitor will configure itself to ask for only the required parameters.
Figure 5 Implement Configuration with All Sensors
For each Flow you have set, you may selection if there is a Sensor per Row, or only Sensor at the pump
or Master Flow. This Flow selection is independent for each Flow (1/2). In the page above you would
have an Implement with Seeds and Flow 1 with sensors at each row.
Press Ok will return you to the Starter page which will now look like this.
2.3.3 Implement Row, Spacing and Width settings
For the Row, Spacing and Width settings press the appropriate button and a Numeric keypad will pop-
up. Enter your number of Rows first, if you then enter the Spacing your Width will be calculated for you.
If after the Row entry, you enter the Width the Spacing will be calculated for you. You can override the
calculated values if you desire.
Image indicates you
selected Seeds and Flow

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Quick Start
13
Figure 6 Row, Spacing and Width Setup
By pressing the Red 0 Button under the Rows column a “Enter Row Spacing” Dialog Box will appear.
Press the Spacing and Width Buttons to open up the Numeric Keypad and enter each parameter.
As you enter each Parameter you will see the List of Require Parameters on the Left change.
Press “Next Page” to go to the Display Assignments Page.
Green Background indicates that
you are done with this page.
List Changes as you Enter
Parameters.

VM-5500 Operator’s Manual
2018
14
Quick Start | Rev 0418.1
2.3.4 Display Assignments
The Display Assignments page is a visual cross reference between the Display Rows and the cable
harness Row wires. Only 8 Display Rows can be seen at 1 time, navigation buttons are available to
navigate to the next set of 8 Rows.
Figure 7 Display Assignments Viewer
The assignments are automatically chosen for you, you can change them to match your implement. If
you need to Change the assignments see Manual Row Assignments in section 3.1.3 below.
2.3.5 Section Assignments
If you have a planter or liquid system that is setup with section shutoff’s, you can configure the rows to
match so the monitor will recognize the shutoffs and not report continuous row failures.
Figure 8 Section Control
By default All Sensors are setup as 1 Section.
If you are not going to use Section Control with your implement, just Press the BLUE “Next Page” button
to navigate to Product Sensor page.

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Quick Start
15
2.3.6 Product Sensor “Seeds”
If you had selected Seeds at the start of this Quick Start the following Screen will appear. The Product
Sensors Seed screen is where you can set your Desired target rate for your Seeds/Acre. After you enter
this rate the default Maximum and Minimum Limits will be calculated with +/- 20%. You may change
percentages or enter absolute numbers.
Press and hold Blue entry fields for a pop-up Numeric Keypad.
Figure 9 Product Sensor Setup for Seeds
Press the Desired Rate Button
After you enter the Desired Value you can likewise change the calculated Limits. Notice the Require List
for our example is now down to only one parameter.
At this point you may also adjust the Sensor Gain parameter. The Sensor Gain is a method to adjust the
actual number of seeds being planted to what is being detected by the seed sensor. You can move

VM-5500 Operator’s Manual
2018
16
Quick Start | Rev 0418.1
population numbers up or down by percentages. Generally used when drilling soybeans to compensate
for doubles. Suggested beginning number is an increase of 12% for most drills.
If you configured your monitor with Seeds ONLY, at this point the Exit button would have changed to
GREEN and the text would read “Exit Finish”. Before you press any buttons go to Section 2.4.1 for
further instructions.
If you had configured your monitor with FLOW (as in this Quick Start Example), press “Next Page” to
navigate to the next Product Sensor “Flow”.
2.3.7 Product Sensor “Flow”
If you had selected 1 or 2 Flows at the beginning of this Quick Start you will need to enter the following.
You must select the flowmeter part number (found on your flowmeters) and then enter the desired GPA
along with the limits. The calibration number is auto generated.
Figure 10 Product Sensor Setup for Flow ½
Press the Desired Rate Button
After you enter the Desired Value you can likewise change the calculated Limits. Notice the Require List
for our example is now complete.

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Quick Start
17
If you had selected two Flow inputs at the beginning of this Quick Start, you will need to press “Next
Page” again, and enter this same information for Flow 2.
With our example at this point the Exit button would have changed to GREEN and the text would read
“Exit Finish”. Before you press any buttons go to Section 2.4.1 for further instructions.
2.4 Exiting Quick Setup (Setup Assistant)
2.4.1 Exit Finish
At this point all required elements have been entered correctly, the Exit Button is now Green and reads
“Exit Finish”.
Your monitor needs a very accurate measure of Speed to provide proper monitoring of Seed population
and Flow rate. The monitor defaults the Speed input to External Speed (RADAR IN) and has a default
Calibration.
But before you go to the field you need to Exit the Setup Assistant by pressing the “Exit Finish” button
and then proceed to Sections 3.3.4 & 0 below. These Sections are part of the Advanced Setup Assistant;
however you can navigate directly to these Setup Screens after pressing “Exit Finish”. Select your Speed
Input and then perform a Speed Calibration procedure to assure proper speed readings.
You are now done with the Quick Start.
2.4.2 Exit Early
If you need to leave this Quick Start procedure before you are finished, you can do so by pressing the
Exit Button which would be Red if you were exiting early. The monitor will save your present entries and
Exit the Setup Assistant; however you will not be able to go to the field until you come back in and finish
the Quick Start.
2.4.3 Not Finished ???
This Quick Start is complete; however the Setup Assistant can still navigate to other features of the
monitor. The other Features are covered in Section 3.2 below.

VM-5500 Operator’s Manual
2018
18
Optional Setup | Rev 0418.1
3Optional Setup
In this section we will go back to some options that we passed by in the Quick Start Section above, as
some implements require Extra Product Sensor (Section 3.1) configurations.
We will also navigate through setting up Accessory Sensors (Section 3.2) as well as some User Interface
Setup (Section 3.3) parameters.
Section 3.1, 3.2 and 3.3 are additional features and are navigated between just like the Quick Start Basic
Features in the Setup Assistant.
Section 3.4 describes the use of the Setup Screen in NORMAL mode which allows you to navigate
directly to the desired parameter using Tab Buttons, instead of Stepping through them in the Setup
Assistant Mode.
3.1 Extra Product Sensor Configurations
In this section we will reference back to the Quick Start Section where we could have made different
selections and then explain them.
3.1.1 Implement Page Options
In the very first page of the Quick Start Section 2.3 you could have modified additional parameters and
exercised other features.
Our Quick Start Example used the Implement 1 configuration. Your monitor can support 4 different
Implement configurations. The setup assistant can walk you through setting up anyone of the 4
available.
The Implement names default to Implement 1…4, you can change these names to match the name of
your Implement (Corn, Beans, Sprayer 1, Sprayer 2, etc..). Press the Green Implement button for a pop-
up Keyboard to enter the desired text.
The Copy button allows you to Copy a configuration from one of the other three configurations. The
Clear button can clear all configuration information from the selected Implement.

VM-5500 Operator’s Manual
2018
Rev 0418.1 | Optional Setup
19
After you have set the Sensors Type, a “Quick Set” button will appear next to the Copy and Clear
Buttons. With this button you can Reset the Default Seed Rows to Harness Row Wires.
3.1.2 Area Monitor Setup
Figure 11 Area Monitor (No Sensors) Setup
In the working Implement in Green called “General Sprayer was configured in the Implement
Configuration Dialog, the “No Sensor” Check Box was checked.
3.1.3 Manual Harness Assignment
From the Display Assignments Screen (Section 2.3.4 above) you could have pressed the Manual Set
button to pop-up the Manual Display Assignment dialog.
Depending on your Monitor Model you will see differ number of Row inputs. First select a Row button
in the middle section of the page. Then on the left side of the page are your Row assignment options.
Pressing 1 of the Sensors will assign it to the highlighted Row input in the middle. The monitor will
increment to the next Row after each Sensor selection.
Select “No Sensors”
Enter Name
Enter Width of
Implement

VM-5500 Operator’s Manual
2018
20
Optional Setup | Rev 0418.1
Figure 12 Manual Harness Assignment Dialog
The figure above shows an 8 Row implement with 8 Rows of Seed, and 8 Rows of Flow. The Flow
sensors are assigned to two different rates. The funnel “Flow Seeds” is for flow blockage sensors often
used on air seeders.
The Black Number in the bottom Right corner of each Row button is the Row Wiring number. The Red
Number in the top Left corner is the Display or Implement Row.
Press “Clear” to start over, “Cancel” to Exiting without recording changes, or “Accept” to accept changes
and return to the Display Assignment Viewer.
With the setup in Figure 12 above the Display Assignment Viewer would look like the following:
Figure 13 Resulting Display Assignments
3.1.4 Section Control
Refer back to Section 2.3.5 above
Section assignments may be entered in this screen. If you have a planter or liquid system that is setup
with section shutoff’s, you can configure the rows to match so the monitor will recognize the shutoffs
Table of contents