1 PACKAGING
The CLIMMA air-conditioning unit is fastened to a wood plane and crated.
Pay attention at opening.
Don’t raise it getting hold of fans and pipes, that can
suffer damage.
On the unit there is a label that describes its technical
specifications.
ATTENTION!
Check that the technical specifications, the electrical supply, etc.... on the label correspond to the technical
specifications of the boat.
Label Example.

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
2.1 FANCOIL EVA INSTALLATION DIAGRAM
01) FAN COIL
02) Air filter
03) Condensation drainpipe
04) Air inlet grill
05) Insulating flexible duct
06) Air outlet plenum
07) Air outlet grill
08) Electrical box
09) Power supply
10) Remote control panel
11) Thermostat bulb
12) Sea water pipes
13) Electrical heater (mod.EH)
14) Water valve
06
02
11
03
04
14
01
12
07
10
05
08
EH version with electrical
heater.
Water valve detail.
13

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
2.2 CENTRALIZED AIR-CONDITIONING SYSTEM – INSTALLATION SCHEMATICS
01) Chiller CWS
02) FAN COIL - EV model
03) FAN COIL - FC model
04) FAN COIL - FCV model
05) Fresh water pipes
06) Electrical box
07) Condensation drainpipe
08) Fresh water valve
09) Sea water valve
10) Sea water intake valve
11) Sea water filter
12) Sea water intake
13) Sea water drainpipes
14) Expansion tank
15) Fancoil collectors
FAN COIL mod. EV
FAN COIL mod. FC FAN COIL mod. FCV
01 1406
13
02
08
02
09 05
15
12
02
11
07
03
04
04
04
03

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
3 COMPONENTS INSTALLATION
3.1 - FUNCTIONING OF THE AIR-CONDITIONERS
During the cooling cycle, the refrigerant circuit transfer the heat from the
ambient air to the sea water.
It is possible to select the functioning cycle, the desired temperature and
the fan speed from a remote control panel that can be installed in the
air-conditioned room.
For detailed information about the control panel, please refer directly to the
remote control panel manual.
While choosing the unit position, it's important to consider the following elements:
1 - the accessibility to the air filter for cleaning operations
2 - the necessary space to fast of the provided clamps
3 - the connection for the condensation drainpipes
4 - there are two possible orientations of the air discharge. Choose the best for connecting the air ducts
5 - the passing of the sea water circuit pipes
6 - the passing of the electrical connection wires and the easy access to the electrical box
Place the pipe-tightening clamps of the water system so that once the unit is arranged, it is still possible to tight the screws.
We suggest to use all stainless steel components.
3.2 - POSITIONING
Versione FANCOIL EV.
Dis. 3-1
3.3 - PLACING
A.- The unit has been designed to
take the ambient air directly away,
therefore it must be installed in the
room that has to be conditioned.
B.- The conditioned air (from the fan) must be piped towards one or more grills through flexible pipes or through
isolated ducts of suitable section in the boat structure.
Dis. 3-2
Dis. 3-5
Dis. 3-3
Dis. 3-4

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
C. The exchanger system takes away the ambient
air. The side with the filter mustn’t be in line with the
aspiration grill, as in the picture 1.6. It can also be in a
different position (see the picture 3.6).
The second solution (picture 3.8) is the best one thanks
to the best sound isolation of the system.
The important thing for the air is to find the shortest and
most linear path, still leaving some space for the filter
maintenance (A).
Top view
Dis. 3-6
Dis. 3-8
Top view
Dis. 3-7
D. The air-conditioner is connected to the electrical box
through cables of 2 m lenght. So there must
be an accessible space (next to the compressor unit
for SPLIT models) to install the electrical box.
E. The thermostat bulb and the aspiration filter must
be mounted on the air-refrigerating gas exchanger.
This side must be accessible for the filter maintenance.
F.- The maximum distance between the control panel
and the electrical box is 3 m both for the thermostat
capillary and for the connection cable.
Dis. 3-9
Dis. 3-10 Dis. 3-11
3 COMPONENTS INSTALLATION

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
3.4 - THERMOSTAT BULB
The thermostat bulb must be fastened to the air
exchanger using special latches.
The bulb must kept separated from the air exchanger
because it must be influenced only by the sucked up
air, but not by the refrigerating circuit. It's also possible
to install the bulb in the room instead of placing it on the
air exchanger, so that it is more sensitive to the ambient
temperature. To fasten the bulb to the wall, you
can use a special plaque given.
Dis. 3-12
3.5 – FANCOIL FIXING – EVA MODEL
3.6 – FANCOIL FIXING – FC MODEL
The fixing has to be done using the
clamps given with the fancoil.
It's suggested to use anti-vibrant when
the installation is in a cabin.
It's also important not to push hard on
the connection cable of the electrical box.
Fancoil FC model has to be fixed on the ground.
EVA fancoils are arranged to have anti-vibrations installed, using apposite
components that can be screwed to the stainless steel basin (see picture 3-13).
NEOPRENE
Dis 3-13
Dis 3-14
Dis 3-15
3 COMPONENTS INSTALLATION

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
3.7 – FANCOIL FIXING – FCC MODEL
Fixing can be done using the holes that are there
In the facoil structure itself (see picture 3.16 – 3.17).
Dis 3-17
Dis 3-16
3.8 - CONDENSATION OUTLET
The air-conditioning determines the generation
of the condensation water due to the humidity
of the conditioned air. This condensation water
must be discharged in the bilge or in a special
tank and then by means of a self-priming pump
in the sea.
The water condensation outlet pipe
must be linked to the rubberholders
of 19 mm on the condensation
collection basin.
Each unit is endowed with two condensate
water outlets, as you can see in the picture
above.
If for any reason the condensation discharge pipe has
to be long, it is better to use the special “L” connection.
Installation as in the picture 3.23 must be avoided. In this
situation the condensation water can stop and flow back
to the collection basin because of the boat rocking.
The direct bulkwark outlet is not the best solution, since it can suck up unpleasant
smells due to the exhaust emissions of its own or of other engines.
Please refer to the safety regulations of the different countries.
Dis 3-23
A
A
A
A
A
Dis 3-19
Dis 3-18
Dis 3-21
Dis 3-20
Dis 3-22
Dis 3-24
3 COMPONENTS INSTALLATION

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
www.climma.it
While the air-conditioner is working, it sucks up and
causes a light vacuum in the room. The condensation
outlet pipe can suck up from the pilge or the special tank
unpleasant smells that can spread in the cabin.
To avoid this possibility, it is possible to create a siphon
(A) as you can see in the picture 3.26 to stop the air.
To check the actual efficiency
of the condensation outlet, pour
some water in the basin.
A
A
Dis 3-26
Dis 3-25
Dis 3-27
3 COMPONENTS INSTALLATION
3.9 - AIR FILTER
FAN COIL mod. FC
FAN COIL mod. EV
FAN COIL mod. FCV
The air-conditioner sucks up the ambient air through an
air-refrigerating gas exchanger endowed with many
aluminum tongues. These tongues would soon become
obstructed because of powder and filth. That’s why you can
mount the air filter directly on the exchanger (as you can
see in picture 3.28).
The filter must be easily taken off to clean or replace it.
For taking off instruction, please follow the picture related
to your model.
Dis 3-29
Dis 3-28
Dis 3-30

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
3.9- AIR CIRCULATION SYSTEM
3.9.A - ASPIRATION
The ambient air is sucked up through one or more grills of suitable dimensions. The minimum dimensions are 350 X 292
(To canalize the air flow back, call a technical assistance).
3.9.B - AIR CIRCULATION
3.9.C - AIR DUCTS
The efficiency of the system depends on the air volume.
This is why it is important to avoid narrow passages in the air
circulation system, keeping the original diameter dimensions
and using short pipes.
The isolated ducts must not be bent
so that the air can circulate currently.
Cut out the unused length
Top view
Top view
Dis 3-32
Dis 3-31
Dis 3-34
Dis 3-33
Dis 3-35 Dis 3-36
3 COMPONENTS INSTALLATION
3.9.D - FANCOIL EV 4
The fan must be linked by means of a duct to the air distribution
system, that can be constituted of one or more grills and
corresponding plenums.
The main duct diameter must not be inferior to the diameter of
the fan fittings.
The fan can be turned by 90°in case of installatio n in a limited
Height environment.
Dis 3-37
Dis 3-38

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
AIR DISTRIBUTION LAYOUT
EXEMPLE DE DISTRIBUTION D’AIR
ESEMPI DI DISTRIBUZIONE ARIA
1 = Air-conditioning unit - Unitè de climatisation - Unità condizionatore
2 = Main air duct - Gaine d’air principal - Condotta d’aria principale
3 = Air splitter plenum - Plenum distribution air - Plenum di divisione aria
4 = Secondary air duct - Gaine d’aire secondaire - Condotta aria secondaria
5 = Air plenum - Plenum grille - Plenum per griglia
6 = Air plenum - Plenum grille - Plenum per griglia
A = Main air delivery grill - Grille distribution principale - Griglia di mandata aria principale
B = Secondary air delivery grill - Grille distribution secondaire - Griglia di mandata aria secondaria
Btu/h 2 L1 A
4000-5000 100 3 300x112
6000-9000 100 3 300x112
10000-13000 125 3 400x112
14000-17000 150 3 400x172
1 2
A
5
L1 1 2
A
5
L1
1 2
A
5
L1
ONE OUTLET - UNE SORTIE SEULEMENT - UNA SOLA USCITA
Btu/h 2 L1 A 4 L2 B
4000-5000 100 3 200x76 3 75 200x76
6000-9000 100 3 300x112 3 75 200x76
10000-13000 125 3 400x76 3 75 200x76
14000-17000 150 3 400x112 3 100 300x112
1 2
3 4
4
A
B
5
6
L1 L2
1 2 3 4
A B
5 6
L1 L2
TWO OUTLET - DEUX SORTIES - DUE USCITE
1 = SUGGESTED - CONSEILLE - SUGGERITO
2 = ACCEPTED - ACCEPTE - ACCETTATO
3 = WRONG - DECONSEILLE - SCONSIGLIATO
R min=1.5 D
1 2 3
R1-R2 min= 2D
DUCT SPECIFICATIONS - SPECIFICATION DU GAINE - SPECIFICHE DELLA CONDOTTA
C331 05/96
Dis 3-39
3 COMPONENTS INSTALLATION

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
3.11 – ELECTRICAL BOX
It contains the following electrical connections:
- to the grid;
- to the compressor-fan-checks group;
- to the control panel;
- to the sea water electrical pump;
- to the external temperature probe.
3.11.A - PLACING
You can install the electrical
box in any position.
Dis 3-40
3 COMPONENTS INSTALLATION
You must install the electrical box near the air-conditioning
unit, to which it is connected by means of a 2 m cable.
It must be easily accessible for the maintenance
or repair.
The electrical box has to be fixed to the wall by 4 screws
Using the provided holes.
3.12- MECHANICAL CONTROL PANEL
Using the control panel, you can set and control the following functions:
SUMMER AIR-CONDITIONING: push the “COOL” button
with the ice star.
WINTER HEATING: push the “HEAT” button with the
orange sun. To switch off, put the switch in the central position.
B. - Setting-regulation of the temperature by means of the
thermostat (TEMP). The thermostat has got a 3 m capillary with
a bulb. The bulb must perceive the sucked up air (it must not
come into contact with the exchanger tongues; it is in fact the
battery where the refrigerant spreads: the tongues cool down,
so that if the bulb comes into contact with them, it will perceive
a temperature value that is lower than the ambient temperature).
C. - Regulation of the fan speed: by means of the button with
the fan it is possible to regulate the four fan speeds. Push the
button to select the fan speed: upwards arrow means speed
increase and downwards arrow means speed decrease. Switching
on the fan for the first time, it will run in MED speed. Then it will run
according to the last selected speed.
Dis 3-41

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
3.13- DIGITAL CONTROL PANEL VEGA MKII
For the technical specifications and for the installation directions,
please refer to the VEGA MKII manual (code: A52000).
Dis 3-43
3.12.A- PLACING
You must choose the correct position to connect the panel to
the board by means of a 3 m cable (included) and to install the
thermostat bulb on the unit exchanger. If necessary, you can
install the bulb not directly on the exchanger but in the room,
choosing the right position to control the temperature.
To fasten the bulb on the wall, you can use the suitable plaque.
3.12.B- INTERCHANGEABLE PLAQUE
The standard plaque (included) is black.
3.12.C - FASTENING
The panel has been designed for a casing fastening. You must drill into it as indicated on the right.
IMPORTANT NOTE: In the panel there is only low voltage. After having installed it, the back must not be accessible. An
optional protection cover (code: M69330) is available. If the panel back is accessible, it may suffer damages.
Dis 3-42
3 COMPONENTS INSTALLATION

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
4 ELECTRICAL CIRCUIT
AVOID THE RISK OF THE ELECTROCUTION !!!
Only qualified staff can execute the troubleshooting and the repair. Keep isolated from the ground during the execution
of the electrical operations, wearing dry clothes, rubber shoes, rubber carpets, etc.... Don’t check wires under voltage
if none can bring help.
IMPORTANT NOTE
To avoid possible electrical shocks, that can cause harm or death to people, execute the grounding of the air-conditioning
system, as indicated:
1- Use a suitable electrical cable with ground wire section and isolation to give the charge from the switch on the control
board of the boat to the electrical box of the system. The ground wire must be correctly connected to the ground terminal
of the panel.
2- Check that the ground connection between the electrical box and the air-conditioner hasn’t suffer any damage during
the transport.
3- Check that the connection of the water pump to the suitable terminal of the electrical box includes also the ground
connection.
4- Check the ground continuity before switching off the air-conditioner.
WARNING
4.1 – ELECTRICAL BOX
Climma fancoils are available in 3 configurations:
●
EV – available with EH option (Electrical Heating)
●
FC
●
FCV
4.2 – POWER SUPPLY
Check that the available supply corresponds to the label on the unit, on the box and on the electrical pump.
The electrical box of the air-conditioner must be connected to mains supply thru a suitable circuit breaker.

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
5.1 – ELECTRICAL BOX SETTINGS
The electrical box connected is supplied already set. Only replacement material has to be set, or when the board is changed.
Detail of the setting device.
5 ELECTRICAL BOX
Dis 5-1
Dis 5-2
Dis 5-4Dis 5-3 Dis 5-5
5.2 - PCB FUSE
A power fuse is included in the board. For the value, make reference to the value.

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
5.3 – WARNING LIGHTS
The PCB is equipped with several warning lights. The schematic here under shows their meaning.
A
B
C
D
LD2:
Change Over Status
LD2 On = Change Over detects cool Fresh Water
Cooling operation can start.
LD2 Off = Change Over detects warm Fresh Water
Heating operation can start.
WATER VALVE neon led
HEATER neon led
FANneon led
The drawing shows the location of the running indicating lights
Queste spie sono direttamente alimentate in tensione di rete, in
parallelo alle diverse uscite. Si accendono quando effettivamente la
scheda alimenta l’uscita.
Dis 5-9
5 ELECTRICAL BOX
5.4 – PCB CONNECTIONS
1c
2c
3c
4c
5c
6c
RS 485 Modbus
Change Over
ALM
RJ45, 8 Pins, ConnectorRemote
Panel VEGA MKII
RJ12, 6 Pins Connector
To second powerboar
(SLAVE)
RJ12
6 Pins Connector
Alternative
Room Probe
Dis 5-10

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
5.4 – PCB CONNECTIONS
1c
2c
3c
4c
5c
6c
RS 485 Modbus
Change Over
ALM
RJ45
8 Pins
ConnectorRemote
Panel VEGAMKII
RJ12
6 Pins Connector
To second powerboar
(SLAVE)
RJ12
6 Pins Connector
Alternative
Room Probe
Dis 5-10
5 ELECTRICAL BOX

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
pag. 22
www.climma.it
5.5 FAN COIL POWERBOARD CONNECTIONS
Dis 5-11
5 ELECTRICAL BOX
BLU cable of multispeed fan MUST be fixed in the “FN” terminal. Inversion
between BLUE & BLACJ cables cause powerboard or fan DAMAGE.
Dis 5-12
FAN COIL MODEL:
EV 4,5, EV 7, EV 9, EV 13
FAN COIL MODEL:
EV 17

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
Dis 5-12
5 ELECTRICAL BOX
FAN COIL MODEL:
EV 15S, EV 17S, EV 24S
Second Fan ONLYfor Fan Coil model FC 4 -FC 16 - FC 20 and FCV 5
Dis 5-13
FAN COIL MODEL:
FC, FCV
5.5 FAN COIL POWERBOARD CONNECTIONS

VECO S.p.A.
Via General Cantore 6/8, 20833 Giussano (MB) Italy
C.F. 06633500159 - P.IVA 00832290969
Phone: +39.0362.35321 | Fax: +39.0362.852995 | E-mail - info@veco.net | Web: www.veco.net
In order to measure inlet air, please follow the below steps:
1.- Measure air inlet grill, excluding the frame, to get the net surface in m
2
;
2.- Measure air flow speed in different positions of the grill;
3.- Sum together all the different measured speeds and divide them by the number of measurements to get the mean speed
(measurement can be in m/s or in other formats, depending on the instrument)
4.- If necessary, convert the mean speed in m/s, and appy the following formula to get the air flow of your system:
Q = SxVx3600
Q = m3/h of air that can be conditioned by your system
S = grill surface in m2 (excluding the frame)
V = air speed in m/s
The air flow value in m3/h obtained with the previous formula has to be compared with the technical specification provided for the product.
Air flow values that vary more that 15/20% are not considered acceptable.
It is also suggested to measure the outlet grills' air flow in order to compare the measurements with the inlet grill one.
When you need air conditioning for two or more spaces, it is important to calculate the air flow to input in the area. This value can be
calculated only knowing the amount of sensible heat of each single space.
If this information is not available, we suggest the following.
Divide the air flow value obtained before (Q) by the total m3 of the space to be air-conditioned. This will give you a ratio between the air
flow that your system can handle and the volume of the air-conditioned space. Multiply this ratio by the volumes of each single area to get
the air-conditioned flow value.
Example:
6 AIR INLET MEASUREMENT
7 USAGE INSTRUCTIONS
7.1 – FAULT DETECTION
Fault detection must be always carried out by qualified technician and by following safety rules.
7.2 - MAINTENANCE
To get the best performances from your air conditioning system, it is important to do the suggested maintenance described below. Periods
can vary based on the installation area of the boat, based on pollution and based on the system usage.
●
Clean the air filter monthly
●
Clean the condensate drain pipe every 4 months
●
Clean the condensate pan every year
●
Substitute the remote control battery every year (only for model VEGA MK2)
Following tasks must be executed with the system off and only by authorized technicians. Do not check eletrical wires if there nobody else
with you, who can assist you in case of emergency. Check sea water piping and fresh water piping every year. Please refer also to the
system Installation Manual.
7.3 - CONDENSATE WATER AND DRAINS
While working, fancoils produce condensate drain, especially when humidity is high. It has to be checked periodically that there are no
leaks on the condensate water drains and that the condensate water drains regularly. For this checks, put some water in the condensate
drain and check that it gets drained quickly.
If the condensate water is drained in the bilge, it is advised to drain it in a specific separate area, since it can generate bad smells.
7.4 - AIR FILTER
The system requires to clean and periodically change the air filter before heat exchanger (B). This filter is required to clean the air before
it goes into the heat exchanger of the fan coil.
There is no specific rule for the system maintenance; it depends on the running hours of the system and from the air pollution. We advise
to clean the air filter every 30 days maximum.
If the air filter is not completely clean system can stop working or loose efficiency. In cool mode (CO) the system efficiency can decrease
significantly, while in the recerce cycle mode (RC), it can cause an high pressure lock and the system will stop working. In the electrical
heater models (EH) the system will stop working due to a security sensor,
7.5 - LOW TEMPERATURE EXPOSURE
If the boat faces sub-zero temperatures, it is required to empty the fan coil and the piping system from all the residual water. In order to
do this, please follow the instructions on the CWS system usage and maintenance.
700
25
15
40
Ratio VT/VC
17,5
438
263
700
Air flow volume (m
3
/h)
Saloon volume to be conditioned mc VC
Cabin volume to be conditioned mc VC
Total volume to be conditioned mc VC
Air m
2
in the saloon = 25x17,5
Air m
2
in the cabin = 15x17,5
Total mc/h
This manual suits for next models
2
Table of contents
Other Veco Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Trane
Trane Packaged TerminalAir Conditioners & Heat... Installation operation & maintenance

Mitsubishi Electric
Mitsubishi Electric MSZ-FA25VA Service manual

Heiko
Heiko JZ026-B1 installation manual

ALPATEC
ALPATEC AC 12 FIT user manual

Trane
Trane DC-UC-WEB01 owner's guide

Bard
Bard THE WALL-MOUNT WA3S3-A installation instructions