Vecom ECX-1200 Series User manual

1.0.0 Edition 20190705
Quick Guide
Hardware Monitor UI
for ECX-1200/1400 Series

1
©Vecow Hardware Monitor UI User Manual Appendix A
A
Software Package
A.1 Installation
Specic drivers are required to be installed before initiating Vecow HW monitor
UI. Please follow below instructions for driver installation.
Step: Run batch le “Win10_64.bat” as Administrator to install Vecow driver and
Framework 3.5.
If error 0x800f081f occurs, please install Framework 3.5 before running
Win10_64.bat. Please nd below URL for framework 3.5 installation.
https://www.microsoft.com/en-US/download/details.aspx?id=25150

2
©Vecow Hardware Monitor UI User Manual Appendix A
A.2 Uninstall
Step: Run batch le “Uninstall_64.bat” as administrator to uninstall Vecow driver.

3
©Vecow Hardware Monitor UI User Manual Appendix B
B
Function Table
B.1 Overview
Overview Table provides board information.
B.1.1 Board Information
Board Information table provides the board / BIOS version and pre-
installed CPU report.

4
©Vecow Hardware Monitor UI User Manual Appendix B
B.2 Hardware control
Hardware control table provides CPU / GPU information report and watch
dog / RPM function set up.
B.2.1 Watchdog
Watchdog timer provides ability to detect and recover from computer
malfunctions. The scope of time rage can be set up from 1 to 3932100
seconds.
Set button
Set up the timeout value and click the bottom to start the countdown.
Stop button
Reset Watchdog value.

5
©Vecow Hardware Monitor UI User Manual Appendix B
B.2.2 CPU
CPU temperature
Current CPU DTS value.
TjMAX temperature
The maximum allowable temperature the cores can reach.
Throttling temperature
The criteria temperature that the processor will downside the performance
for cooling.
B.2.3 GPU
GPU model
GPU information.
GPU core temperature
Current GPU DTS value.
B.2.4 FAN
Fan Fail Detect
The system will initiate the shutdown process in one second after the
value of RPM is under protected RPM for more than one minute.
Protected RPM
The criteria that prevent the Fan speed from overloaded.
RPM
Current Fan speed (The value is updated in every 6 seconds).
Start button
Initiate Fan speed detection.
Stop button
Interrupt Fan speed detection.
Fan Control
SmartGuardian Automatic Mode provides 256 steps of PWM control.

6
©Vecow Hardware Monitor UI User Manual Appendix B
B.3 IO
IO table provides Digital IO function.

7
©Vecow Hardware Monitor UI User Manual Appendix B
DIO denition
16-bit DIO (Isolated / Non-Isolated) 20-pin terminal block connector. Isolated
DIO pins are xed by Hardware design that cannot change in / out direction in
runtime process.
Pin
No.
Isolated DIO
Denition
GPIO
Denition
Pin
No.
Isolated DIO
Denition
GPIO
Denition
1 DI 0 GPIO 0 11 DO 0 GPIO 8
2 DI 1 GPIO 1 12 DO 1 GPIO 9
3 DI 2 GPIO 2 13 DO 2 GPIO 10
4 DI 3 GPIO 3 14 DO 3 GPIO 11
5 DI 4 GPIO 4 15 DO 4 GPIO 12
6 DI 5 GPIO 5 16 DO 5 GPIO 13
7DI 6 GPIO 6 17 DO 6 GPIO 14
8 DI 7 GPIO 7 18 DO 7 GPIO 15
9 DI_COM NC 19 DIO_GND GPIO_GND
10 DIO_GND GPIO_GND 20 External VDC NC
Isolated DIO Signal Circuit
DI reference circuit :
Sink Mode
(NPN) Power
Supply
6-48V DC V+
V-
DIO Connector
DI_COM (Pin 9)
DI (Pin 1-8)
Source Mode
(PNP) Power
Supply
6-48V DC V+
V-
DIO Connector
DI_COM (Pin 9)
DI (Pin 1-8)

8
©Vecow Hardware Monitor UI User Manual Appendix B
DO reference circuit :
Sink Mode
(NPN, Default) Device
6-48V DC V+
V-
DIO Connector
DIO_VDC (Pin 20)
DIO_GND (Pin 10, 19)
IO DO (Pin 11-18)
Source Mode
(PNP) Device
6-48V DC V+
V-
DIO Connector
DIO_VDC (Pin 20)
DIO_GND (Pin 10, 19)
IO DO (Pin 11-18)
B.3.1 Isolated DIO
Sink (NPN) / Source (PNP) radio button
Select Sink (NPN) / Source (PNP) MODE.
Set button
DIO conguration must be dened before DO output condition.
Get button
Dene DIO conguration to get DI input condition.
Output data (Hex)
DO output condition is dened by a hexadecimal bitmask - on / off.
Range: 0x00~0xFF, 1: High; 0: Low.
Input data (Hex)
DI input condition is dened by a hexadecimal bitmask - on / off.
Range: 0x00~0xFF, 1: High; 0: Low.
Example
Dene Output data 0x00 LED all bright on sink(NPN) mode.
Dene Output data 0xFF LED all bright on source(PNP) mode.
Loopback test (connect pin.1-11 ~ pin.10-20):
Dene sink(NPN) mode output and Get source(PNP) mode input.

9
©Vecow Hardware Monitor UI User Manual Appendix B
B.4 PoE Control
PoE control table provides PoE on/off switch.

10
©Vecow Hardware Monitor UI User Manual Appendix B
POE denition
Port No. Denition Port No. Denition
1 POE 0 3 POE 2
2 POE 1 4 POE 3
Slave Address
Range: 0x40~0x5E (16 address).
Auto detect all available PoE.
Status
Green: PoE on; Red: PoE off.
Select mode
Auto: Auto detect Power device.
Manual: Turn on/off PoE by user.
PoE switch
ON: Turn on PoE for manual mode.
OFF: Turn off PoE for manual mode.

11
©Vecow Hardware Monitor UI User Manual Appendix B
B.5 SMBUS
SMBUS table provides BUS data accessed on SMBUS.

12
©Vecow Hardware Monitor UI User Manual Appendix B
B.5.1 BUS data
BUS data function supports only byte transmission.
Slave Address
The SMBUS slave device address is expected in 8-bit hex format with the
7-bit address in the upper seven bits and the lowest bit set as read (1) /
write (0) bit accordingly.
Register/Command
The SMBUS command enables access to SMBUS devices.
Data
Support transfer type: Read/Write Command Byte.
SMBUS control PoE
PoE slave address
Range: 0x40~0x5E (16 address).
Set 4-port PoE Conguration for auto mode
Register 0x12, Write 0xFF.
Register 0x13, Write 0xF0.
Register 0x14, Write 0xFF.
Set 4-port PoE Conguration for manual mode and trun on/off PoE port:
Register 0x12, Write 0x55.
Register 0x13, Write 0x00.
Register 0x14, Write 0x00.
Register 0x19, Write 0x0F/0xF0.
This manual suits for next models
1
Table of contents