Veilux VPIP-D118-/O User manual

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
1
Website: www.Veilux.net Phone# 1-800-510-6528

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
2
Website: www.Veilux.net Phone# 1-800-510-6528
Certification
Veilux provides the best products with the certification below.
Revision History
Date
Rev No.
Description
2010-11
1.0
Creation of the document

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
3
Website: www.Veilux.net Phone# 1-800-510-6528
Warning & Cautions
If you fail to read this information and handle the product incorrectly, faulty or malfunction as well as
death or serious injury may occur.
This Unit should be installed by trained
personnel.
Immediately stop using when the product
emits smoke or abnormal heat.
Never install the product in area exposed to
oil or gas.
Never install the product on a ceiling that
cannot hold its weight.
Never touch the power cord with wet hands.
Clean only with dry cloth.
Never use the product in extremely high or
low temperature condition.
Never drop, hit, strongly nor vibrate
the product.
Never expose the product to direct sunlight
or severe ray.
Never touch the front glass of the product.

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
4
Website: www.Veilux.net Phone# 1-800-510-6528
Indications:
Warning: Death or Serious Injury will occur without following Warning.
Caution : Operational Problem(Faulty & Malfunction) will occur without complying with Caution
Reference : Technical Information for Users

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
5
Website: www.Veilux.net Phone# 1-800-510-6528
Table of Contents
Table of Contents................................................................................ 5
1. Introduction................................................................................... 7
1.1. Overview of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.......................................... 7
1.2. Specification........................................................................................... 8
1.2.1. Basic Specification of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I .........................................8
1.2.2. Detailed Specification of Camera Module & PTZ of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I......9
1.2.3. Basic Specification of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I .......................................11
1.2.4. Detailed Specification of Camera Module of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I ............12
1.3. Application of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I...................................... 14
2. Production Description................................................................... 15
2.1. Package Contents .................................................................................... 15
2.1.1. Veilux VPIP …................................................................................................. 15
2.1.2. Veilux VPIPI................................................................................................... 15
2.2. Preview .................................................................................................. 16
2.3. Physical Description.................................................................................. 17
2.3.1. External View ................................................................................................. 17
2.3.2. Bottom View & Connection Diagram...................................................................... 17
2.3.3. External & Internal View..................................................................................... 18
2.4. Functional Description ............................................................................... 19
3. Bracket Installation ...................................................................... 22
3.1. Veilux VPIP ............................................................................................. 22
3.1.1. Basic Components & Mounting Accessories ............................................................ 22
3.1.2. Preparation....................................................................................................22
3.1.3. Installation using Walling Mount Type..................................................................... 24
3.2 Veilux VPIPI ............................................................................................. 26
3.2.1. Preparation....................................................................................................26
3.2.2. Installation using Ceiling Mount Type..................................................................... 27
3.2.3. Installation using Embedded Mount Type ................................................................ 28

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
6
Website: www.Veilux.net Phone# 1-800-510-6528
4. Installation .................................................................................. 31
4.1. Required System Specification.................................................................... 31
4.2. Quick Installation Guide ............................................................................. 32
5. Trouble Shooting.......................................................................... 36
5.1. No Video on Viewer................................................................................... 36
5.2. Windows vista and Windows 7 User for Record & Capture Problem ................... 37
5.3 Technical Inquiry........................................................................................ 40
6. Appendix.................................................................................... 41
6.1. FAN & Heater .......................................................................................... 41
6.2. DIP Switch Setting .................................................................................... 42

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
7
Website: www.Veilux.net Phone# 1-800-510-6528
1. Introduction
1
1.
.1
1.
.
O
Ov
ve
er
rv
vi
ie
ew
w
o
of
f
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-O
O
/
/
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-I
I
Veilux VPIP-D1XXX-O / VPIP-D1XXX-I, as a state-of-the-art 1Channel Speed Dome Network Camera based
on integrated Embedded Software technologies such as H.264 & MJPEG, G.726 & PCM Video & Audio
Compression, Embedded Web Server, Embedded Streaming Server, various Network Protocols, transmits
synchronized video and audio data in real time through IP Network as well as supports bi-directional audio
communication by allowing transmission of audio from Client PC Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Veilux VPIP-D1XXX-O / VPIP-D1XXX-I with completed Integration with analog CCTV camera, Digital and
network technology, is applicable for various sectors such as Security, Remote Monitoring, Remote Education,
Simple Video Conference as well as Internet Broadcasting System etc.

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
8
Website: www.Veilux.net Phone# 1-800-510-6528
1
1.
.2
2.
.
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
n
1
1.
.2
2.
.1
1.
.
B
Ba
as
si
ic
c
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
n
o
of
f
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-O
O
/
/
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-I
I
Class
Description
Video
Compression
H.264 / MJPEG
Resolution
**Refer to the datasheet
Audio
(Bi-directional)
Up Stream
32 Kbps G.726
Down Stream
64 Kbps PCM
Network
Interface
RJ-45, 10/100 Mbps
Access Network
Static, DHCP, PPP/PPPoE
Protocol
IPv4/6, TCP, UDP, IGMP, ICMP, ICMPv6 etc.
I/O
Sensor
4
NC, NO Selectable
Relay Output
2
Alarm or Remote ON/OFF Control (30V, 1A)
RS-232C
Factory Default
Mic/Line In
Selectable on Admin Page
Line Out
1 V p-p Audio Output for Amp embedded Speaker
CVBS Output
Supported
Power
PoE
AC In
24VAC Adaptor (higher than 1.5 Amp)
Housing
Water-Proof
IP66
Heater
Refer to Installation Configuration
Installation Type
Bracket
Wall, Ceiling, Ceiling Embedded Type
Motion Detection
3 Regions
Optional Shape & Sensitivity for 3 Regions
Upgrade
Remote F/W Upgrade via IP Network
Management & Configuration
Remote Management & Configuration using IP Network and
Admin Tool Page
Client/Viewer
Web Viewer
Simple Access via Internet explorer
NVR-Pro
CMS Software
3rd Party CMS
Contact to Veilux
Dynamic IP
DDNS support
Supported by Veilux Management Server
Security Management
User ID & Password Protection, IP Filtering, Audio per user
and Bi-directional audio communication configuration control
Time
Configuration
Management
Sync to PC
Sync to PC Time
Manual
Manual Configuration
Internet Time Server
Sync to Time Server

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
9
Website: www.Veilux.net Phone# 1-800-510-6528
DLS
Time Configuration
1
1.
.2
2.
.2
2.
.
D
De
et
ta
ai
il
le
ed
d
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
n
o
of
f
C
Ca
am
me
er
ra
a
M
Mo
od
du
ul
le
e
&
&
P
PT
TZ
Z
o
of
f
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-O
O
/
/
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-I
I
Class
18X Optical
26X Optical
27X Optical
33X Optical
36X Optical
(WDR)
37X Optical
PAN
/
TILT
PAN Rotation Angle
360˚
PAN
Rotation
Speed
Manual
0.5˚ ~ 200˚/sec (64step)
Preset
Max. 300˚ /sec , Min. 10˚ /sec
TILT Rotation Angle
-2˚ ~ 90˚
TILT Speed
Manual
0.5˚ ~ 45˚/sec (64step)
Preset
Max. 250˚ /sec , Min. 200˚ /sec
System Accuracy
0.024˚
Functions
Preset
165 Presets identifiable with 16 character label for each preset.
Group Tour
Max. 8 Programmable Group Tours
(Max. 60 different Presets Steps for each Group Tour)
Auto Rotation
Programmable Auto Scan
Pattern
Max. 8 Programmable Patterns( 50sec/Pattern, Total 480sec)
Sector
16 character label identifiable 8 Programmable Sectors
Password Protection
Yes
Privacy Zone
24
24
8
8
24
8
Alarm Input
Max. 4 Alarm Input (Programmable)
Alarm Actions
Preset, Group Scan or Activate Output on Alarm Input
AUX Output
2 Relay Output
Auto Flip
ON / OFF
OSD Menu
Yes
Serial
Communication
RS-485
Protocol
Pelco-D, Pelco-P Embedded
Mis.
Motor
Stepping Motor
Micro Step
1/8 Micro Step
Camera
Module
Image Sensor
1/4" Sony
Exview
HAD CCD
1/4"Sony
Exview
HAD CCD
1/4"Sony
super
HAD CCD
1/4"Sony
super
HAD CCD
1/4"Sony
Exview
HAD CCD
1/4"Sony
super
HAD CCD
No. of
NTSC
811(H) * 508(V) 410K

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
10
Website: www.Veilux.net Phone# 1-800-510-6528
Pixels
PAL
795(H) * 596(V) 470K
No. of
Effective
Pixels
NTSC
768(H) * 494(V) 380K
PAL
752(H) * 582(V) 440K
Horizontal
Resolutio
n
NTSC
470TV line
470TV line
550TV
line(Color)
680TV
line(B/W)
550TV
line(Color)
680TV
line(B/W)
530TV
line(Color)
550TV
line(Color)
680TV
line(B/W)
PAL
460TV line
460TV line
530TV
line(Color)
ZOOM
Optical
18x Optical
Zoom
(F=1.4~3.0,
f=4.1~73.8mm
)
26x Optical
Zoom
(F=1.6~3.8,
f=3.5~91.0mm
)
27x Optical
Zoom
(F=1.6~2.9,
f=3.5~94.5mm
)
33x Optical
Zoom
(F=1.6~3.6,
f=3.5~115.5m
m)
36x Optical
Zoom
(F=1.6~4.5,
f=3.4~122.4m
m )
37x Optical
Zoom
(F=1.6~3.9,
f=3.5~129.5mm)
Digital
12x (total 216x)
12x (total 312x)
12x (total 324x)
12x (total 396x)
12x (total 432x)
12x (총444x)
Day/Night(ICR)
Auto/ Day/ Night
Digital Slow Shutter
ON/ OFF
Min.
Illuminatio
n
Normal
(50IRE)
0.05Lux
0.14Lux
0.4Lux
0.4Lux
0.1Lux
0.7Lux
B/W
(ICR ON)
0.01Lux
0.05Lux
0.02Lux
0.02Lux
0.01Lux
0.061Lux
Sense-up :
256x
N/A
N/A
0.00007Lux
0.00007Lux
N/A
0.00007Lux
Luminance S/N
Ratio
Higher than 50dB
Video Output
Video Output 75Ω
BLC
ON / OFF
Flicker less
ON / OFF

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
11
Website: www.Veilux.net Phone# 1-800-510-6528
1
1.
.2
2.
.3
3.
.
B
Ba
as
si
ic
c
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
n
o
of
f
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-O
O
/
/
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-I
I
Class
Description
Video
Compression
H.264 / MJPEG
Resolution
1280x720, 800x608, 704x480, 640x480, 704x240,
352x240,176x112
Audio
Up Stream
32 Kbps G.726
Down Stream
64 Kbps PCM
Network
Interface
RJ-45, 10/100 Mbps
Access Network
Static, DHCP, PPP/PPPoE
Protocol
IPv4/6, TCP, UDP, IGMP, ICMP, ICMPv6 etc.
I/O
Sensor(Alarm)
4
NC, NO Selectable
Relay Output(Aux)
2
Alarm or Remote ON/OFF Control (30V, 1A)
Mic/Line In
Selectable on Admin Page
Line Out
1 V p-p Audio Output for Amp embedded Speaker
CVBS Output
Supported
Power
PoE
Not Supported
AC In
24V AC Adaptor (higher than 1.5 Amp)
Housing
Water-Proof
IP66
Fan & heater
Supported
Installation
Type
Bracket
Wall, Ceiling, Embedded(Flush)
Motion
Detection
3 Regions
Optional Shape & Sensitivity for 3 Regions
Upgrade
Remote F/W Upgrade via IP Network
Management & Configuration
Remote Management & Configuration using IP Network and Admin
Tool Page
Client/Viewer
Web Viewer
Simple Access via Internet explorer
NVR-Pro
CMS Software
3rd Party CMS
Contact to iCanTek
Dynamic IP
DDNS support
Supported by iCanTek’s Management Server
Security Management
User ID & Password Protection, IP Filtering, Audio per user and Bi-
directional audio communication configuration control
Time
Configuration
Sync to PC
Sync to PC Time
Manual
Manual Configuration

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
12
Website: www.Veilux.net Phone# 1-800-510-6528
Management
Internet Time Server
Sync to Time Server
DLS
Summer Time Configuration
1
1.
.2
2.
.4
4.
.
D
De
et
ta
ai
il
le
ed
d
S
Sp
pe
ec
ci
if
fi
ic
ca
at
ti
io
on
n
o
of
f
C
Ca
am
me
er
ra
a
M
Mo
od
du
ul
le
e
o
of
f
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-O
O
/
/
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-I
I
Class
Description
CCD Image
Sensor
Image Size
6mm Dia. (Type 1/3)
Effective Pixels
1.3M (1296 x 966)
Progressive Scan
YES
Output Pixels / FPS
1280(H)x720(V) / 30fps
Lens
Optical Zoom
18X
Practical f-value
4.7~84.6mm
Practical H.angle
55.2°(w)~3.2°(t)
F-value
F1.6(w)~F2.8(t)
Focus
Auto
VAF
Manual (Far/Near)
Provided (soft)
Focal Range (setting)
Infinity~1m(t)~0.01m(w) (soft)
IR Removable
Auto
Pro.AER+
Manual (On/Off)
Provided (soft)
Durability
Zoom / Focus / Iris
500k cycles
IR Removable
50k cycles
DSP Function
Digital Slow Shutter
YES
Wide Dynamic Range
Off / On (soft)
Image Freeze
Off / On (soft)
Mirror
Off / On (soft)
Vertical Invert
Off / On (soft)
Image Reverse
Off / On (soft)
Privacy Masking
8 zone
Motion Detect
Off / On (soft)
Frame Noise Reduction
Off / On (soft)
Preset
Max. 135
Dynamic Spot Cancel
YES
Electrical Shutter
Shutter Speed
Auto (1/30s~1/4000s)
Sensitivity
Max. 1/4s (soft)
Iris
BLC
Off / On (soft)
White Balance
Off / On (soft)

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
13
Website: www.Veilux.net Phone# 1-800-510-6528
Resolution Horizontal
600 TVL (1280 x 720 pixels)
Min. Sensitivity
(F1.6, 50IRE)
IR-cut On (1/30s)
1.8 Lux
IR-cut Off (1/4s)
0.02 Lux

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
14
Website: www.Veilux.net Phone# 1-800-510-6528
1
1.
.3
3.
.
A
Ap
pp
pl
li
ic
ca
at
ti
io
on
n
o
of
f
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-O
O
/
/
V
VP
PI
IP
P-
-D
D1
1X
XX
XX
X-
-I
I
- Security Surveillance (Building, Stores, Manufacturing Device, Parking Lot, Bank, Public Office &
Military etc.)
- Remote Monitoring (Hospital, Kindergarten, Traffic Status, Public Area)
- Video Conference, Remote Lecture, Internet Broadcasting
- Climate & Environment Surveillance

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
15
Website: www.Veilux.net Phone# 1-800-510-6528
2. Production Description
2
2.
.1
1.
.
P
Pa
ac
ck
ka
ag
ge
e
C
Co
on
nt
te
en
nt
ts
s
Open the package and check if the followings are included;
2
2.
.1
1.
.1
1.
.
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
P
Contents
Description
Remark
Bracket & Housing
Outdoor Housing, Wall Mount Bracket
Accessories
Screw (M4x15 4EA), Safety Cable
Manual
Housing Installation Manual
IP Camera
Veilux VPIP-D Body
Tools & Accessories
Wrench, Safety Cable, Cable Tie, Terminal
Block
(2Pin, 3Pin , 5Pin ,6Pin : 1EA), Screw(Ø 3x6
2EA, Ø4x16 5EA)
CD
Software & Product User Manual
Quick Reference
Quick Installation Guide
2
2.
.1
1.
.2
2.
.
V
Ve
ei
il
lu
ux
x
V
VP
PI
IP
PI
I
Content
Description
Remark
IP Camera
Veilux VPIPI-D Body
Tools & Accessories
Wrench, Safety Cable, Cable Tie, Terminal
Block
(2Pin, 3Pin , 5Pin ,6Pin : 1EA), Screw(Ø 3x6
2EA, Ø4x16 5EA)
CD
Software & Product User Manual
Quick Reference
Quick Installation Guide
* 24V AC Adaptor, as optional item, can be purchased separately.

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
16
Website: www.Veilux.net Phone# 1-800-510-6528
2
2.
.2
2.
.
P
Pr
re
ev
vi
ie
ew
w
Veilux VPIP-D1XXX-O / VPIP-
D1XXX-I
IP-Installer
CMS Software
(NVXR-64)
Speed Dome Network Camera
IPAssignment Program
PC based Client for
monitoring/storing Video/Audio
transmitted form Product
(Max. 16CH supported)

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
17
Website: www.Veilux.net Phone# 1-800-510-6528
2
2.
.3
3.
.
P
Ph
hy
ys
si
ic
ca
al
l
D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
2
2.
.3
3.
.1
1.
.
E
Ex
xt
te
er
rn
na
al
l
V
Vi
ie
ew
w
Fig 2-1. External View of Veilux VPIP-D1XXX-O / VPIP-D1XXX-I
2
2.
.3
3.
.2
2.
.
B
Bo
ot
tt
to
om
m
V
Vi
ie
ew
w
&
&
C
Co
on
nn
ne
ec
ct
ti
io
on
n
D
Di
ia
ag
gr
ra
am
m
Fig 2-2. Terminal Block, LAN & AC Power Connector

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
18
Website: www.Veilux.net Phone# 1-800-510-6528
2
2.
.3
3.
.3
3.
.
E
Ex
xt
te
er
rn
na
al
l
&
&
I
In
nt
te
er
rn
na
al
l
V
Vi
ie
ew
w
Fig 2-3. Connector Part
Fig 2-4. Outdoor Housing

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
19
Website: www.Veilux.net Phone# 1-800-510-6528
2
2.
.4
4.
.
F
Fu
un
nc
ct
ti
io
on
na
al
l
D
De
es
sc
cr
ri
ip
pt
ti
io
on
n
AC Power
Connect 24 Volt AC adaptors to this terminal for supplying power to the network camera.
AC adapter which is compliant to the specification for Veilux VPIP-D1XXX-O / VPIP-D1XXX-I
should be used. Misuse of power supply can cause damage to Veilux VPIP-D1XXX-O / VPIP-
D1XXX-I. Veilux assumes no responsibility for misuse of the power supply.
MIC/LINE IN
Connect external audio source or microphone.
Line Out
Connect speakers with built in amplifier. Audio from remote site is output through Line out in bi-directional
audio mode.
100Base-T
100Mbps Ethernet connector (RJ-45). 2 LEDs on the Ethernet connector shows the status of Veilux VPIP-
D1XXX-O / VPIP-D1XXX-I as the followings:
-Status LED (Dual Color - Red/Green): It will be lit in green or red depending on the status.
Green: Green color indicates that the camera is in normal operation mode. Continuous green
Indicates that data transmission is possible. Blinking green means that someone is
Connected to Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Red: Continuous or blinking red indicates that hardware is in abnormal condition.
Red/Green LED will be lit with red momentarily and it will be lit with green after a while when
power is applied into Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
LINK/LAN LED (Orange) : It will be lit with orange color when network cabling is all right. Blinking
orange color indicates that normal data transmission is under way. Off state indicates that there is
trouble in network connection.

Veilux User Manual for VPIP-D118-/O, D126X-I/O, D127X-I/O, D133X-I/O,
D136X-I/O, D136X With WDR-I/O, D137X-I/O
I= Indoor D= Outdoor
Rev.1.0 (April 2011)
20
Website: www.Veilux.net Phone# 1-800-510-6528
-
Alarm In/Out (ALARM/AUX)
Used for connecting alarm sensor, alarm annunciation device to Veilux VPIP-D1XXX-O / VPIP-D1XXX-I.
Class
Description
Alarm IN
Sensor In (+). NC/NO Selectable in Admin Mode
Alarm IN GND
Ground for Sensor In
Aux OUT
Alarm Output Terminal
Aux OUT(GND)
Ground for Sensor Output
Aux
Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light.
Relay is normal open and it will be closed upon alarm annunciation or remote on. The relay is capable
of switching 30V AC/DC, 2A. For the application which needs power switching beyond this limit, use
additional relay switch as shown as below figure.
Fig 2-5. Relay Connection Diagram(Left : lower than 30V, 2A, Right : Higher than 30V 2A)
Alarm
Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor,
heat/smoke sensor, magnetic sensor, etc. Connect the two wires of the sensors to “SNS In”. The sensor
type (NC/NO) can be set in admin page. 10mA can be flown into sensor device. Multiple sensor devices
can be connected in parallel.