Videofied DCV200 User manual

Product Summary
The Camera Model DCV200/DCV700/DCV600 is a wireless, indoor
motion activated camera designed for use in VIDEOFIEDTM security
systems.
The camera includes the following features:
> Lithium batteries for long life.
>Wide angle lens.
>Infrared LED for night illumination.
>Standard motion coverage lens (12 m/40 ft. distance).
>Dual tamper function provides detection for both
wall and cover tamper.
>Transmits check-in/status signal every 8 minutes.
Installation Guidelines
For easier installation, programming and RF testing
should be done to check for good communication between
the control panel and all system devices before mounting
system devices. Install the detector and other system
devices in the following order:
>Programming/RF Testing - program detector and all other
devices into the control panel and test RF communication from
each intended device location to the control panel.
>Mounting - mount detector at the tested location.
Programming/RF Testing
The following provides summarized steps for device
programming and testing. For complete details, refer
to the control panel installation manual.
1Loosen bottom screw, separate base
from camera and install batteries.
2Re-attach base to secure
tamper switch.
3Put control panel into
programming/conguration mode.
4Using a programmed alphanumeric
keypad, proceed through menus
until the display shows ADD A
NEW DEVICE.
5Press YES. The display shows PRESS
PROGRAM BUTTON OF DEVICE.
6Press and release program button
on camera using a paper clip end.
The camera LED ashes. Wait for
keypad display to show CAMERA
(1 - 24) PROGRAMMED.
7 Press YES. The display shows
RADIO RANGE TEST? Press YES
again. The camera LED starts
ashing and keypad display
shows TEST IN PROGRESS.
8Take camera to its intended mounting location and
make sure LED ashes continuously, indicating good
communication with control panel.
9Press YES to end radio range test, then press ESC/NO.
10 The display shows AREA ASSIGNMENT AREA: Press
either arrow button repeatedly until desired AREA
number appears, then press Yes.
11 The display shows NAME + LOCATION. Enter appropriate
device name/location (up to 16 characters), then press
YES. The display shows the device number and name
for your verication.
12 Press YES. The display shows FUNCTIONAL DEVICE TEST?
Press YES again and verify camera operation.
For example, wave your hand in front of the camera to
activate its LED indicating detection. (walk test LED)
13 Press YES to end detection verication.
14 The display shows ADD A NEW DEVICE?
Repeat steps 1 – 14 for remaining cameras.
15 When nished, exit from conguration mode.
www.videofied.com
Program Button
Screw
I N S T A L L A T I O N I N S T R U C T I O N S
Camera Model DCV200/DCV600/DCV700
Made by RSI VIDEO TECHNOLOGIES 1002-c July 2008

Regulatory Information
FCC Part 15
This device complies with FCC Rules Part 15. Operation
is subject to the following two conditions:
1.) This device may not cause harmful interference and,
2.) This device must accept any interference that may be received,
including interference that may cause undesired operation.
Changes or modications not expressly approved
by RSI VIDEO TECHNOLOGIES can void the user’s authority to
operate the equipment
Mounting
> Use proper tools and hardware.
> Mount indoors in a temperature-controlled environment.
> Mount camera 2.1 to 2.3 m (6.9 to 7.5 ft.) from the oor.
> Mount detector on an outside wall, aimed at area to
be secured.
> Do not aim detector at windows, especially those that
let in direct sunlight, or at heat sources such as lamps,
replaces, radiators, and heating vents.
> Do not aim detector at moving objects such as curtains,
fans.
Specifications
Panel Compatibility VIDEOFIED VISIO1000/V6000/V7000
Operating Frequency 868/915/920 MHz
Radio type Spread Spectrum Bidirectional RF
Power Requirements Three 3.6 V lithium batteries
Battery Type LS14500
Motion detection Lens: Fresnel
Detection distance: 12 m/ 40 ft.
Angle: 90°
Detector type: Dual elements
Weight threshold: 18 kg/40 lbs.
Camera sensor CMOS black & white
Video resolution 320 x 240 pixels
Video sequence (in alarm) 5 frames/s for 10 seconds
Video sensitivity 0.2 lux
Lens Wide-angle 85° (no IR treatment)
Night illumination type Infrared (LED)
Night illumination distance 4.5 m/14 ft.
Operating Temperature 0°/+40°C (32°/104°F)
Maximum Relative Humidity 70%, non-condensing
Dimensions 89 mm x 70 mm x 70 mm
(LxWxD): 3-1/2 in. x 2-3/4 in. x 2-3/4 in.
Weight 150 g/5.3 oz. (without batteries)
Approvals CE / EN50131 / EN300220 / INCERT/ IDA / NCP (DCV200)
UL / FCC (DCV600)
A-Tick (DCV700)
1Separate base from camera.
2Hold camera base against
mounting surface and mark the
two appropriate mounting holes.
3Drill pilot holes and install
anchors where needed.
4Place base on mounting surface
so mounting holes line up with
pilot holes/anchors and secure
base with appropriate screws.
5Install batteries into camera, observing correct polarity.
6Attach camera to base and secure with screw.
EMEA SALES
2, rue Alexis de Tocqueville
92160 ANTONY
FRANCE
Phone +33 (0)1 55 59 10 25
Fax +33 (0)3 90 20 66 36
© 2008 RSI VIDEO TECHNOLOGIES. VIDEOFIEDTM is a Registered Trademark of RSI VIDEO TECHNOLOGIES.
S2View®is a registered trademark of RSI VIDEO TECHNOLOGIES. Specications subject to change without notice.
USA SALES
4455 White Bear Parkway, Suite 700
White Bear Lake, MN 55110
USA
Phone 877-206-5800
Fax 651-762-4693
www.videofied.com
Flat Wall Mounting Holes
Corner Mounting Holes
I N S T A L L A T I O N I N S T R U C T I O N SCamera Model DCV200/DCV600/DCV700
This manual suits for next models
2
Table of contents