Viega Advantix Top 4914.20 User manual

for bonded sealing (tiled shower) with sealing mat
Model Year built:
4914.20 from 01/2010
en_INT
Advantix Top bath drain
Instructions for Use

Advantix Top bath drain 2 from 24

Table of contents
1About these instructions for use 4
1.1 Target groups 4
1.2 Labelling of notes 4
1.3 About this translated version 5
2Product information 6
2.1 Standards and regulations 6
2.2 Intended use 6
2.2.1 Areas of use 6
2.2.2 Media 7
2.2.3 Drainage capacity 7
2.3 Product description 7
2.3.1 Overview 7
2.3.2 Technical data 8
2.4 Information for use 8
2.4.1 Installation variations 8
2.4.2 Sealing 9
2.4.3 Fire protection 11
2.5 Required accessories 12
3Handling 13
3.1 Assembly information 13
3.1.1 Important note 13
3.1.2 Installation dimensions 13
3.1.3 Tools and materials 13
3.2 Assembly 14
3.2.1 Construction and water seal level 14
3.2.2 Mount base unit 16
3.2.3 Sealing the drain 19
3.2.4 Mounting the top 21
3.3 Care 22
3.3.1 Care tips 22
3.3.2 Cleaning the drain 23
3.4 Disposal 24
Table of contents
Advantix Top bath drain 3 from 24

1 About these instructions for use
Trade mark rights exist for this document, further information can be
found at
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following
groups of people:
nHeating and sanitary professionals and trained personnel
nTilers
nConsumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Advantix Top bath drain 4 from 24

1.3 About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand-
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Advantix Top bath drain 5 from 24

2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
viega.com/standards
.
Regulations from section: Sealing
Scope / Notice Regulations applicable in Ger-
many
Stress class of the underground,
as well as suitable bonded sealing
ZDB-Merkblatt 8/2012
Stress class of the underground,
as well as suitable bonded sealing
Leitfaden zur Abdichtung im Ver-
bund (AIV)
Approved bonded sealings with
proof of practicability in keeping
with building law for stress
classes A and AO
ETAG 022 T1
Approved bonded sealings with
proof of practicability in keeping
with building law for stress
classes A, B and C
DIBt-Bauregelliste A, Teil 2 des
DIBt und Prüfgrundsätze für
Abdichtungen im Verbund
(PG AIV-F)
Permitted bonded sealings EN 14891
Regulations from section: Media
Scope / Notice Regulations applicable in Ger-
many
Typical domestic wastewater DIN 1986-3
2.2 Intended use
2.2.1 Areas of use
The drain is designed for small to medium volumes of water, which
occur in e. g. residential building.
Technical information, see
ÄChapter 2.3.2 „Technical data“ on page 8
.
Product information
Advantix Top bath drain 6 from 24

2.2.2 Media
nThe short-term temperature of the wastewater may reach up to
95° C. The temperature must be considerably lower in constant
operation.
nThe pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the
product material.
2.2.3 Drainage capacity
The drainage capacity is dependent on the chosen installation height.
The drainage capacity is 0.8 l/s up to 1.2 l/s with horizontal DN 50 drain
support.
2.3 Product description
2.3.1 Overview
1
2
4
6
5
3
7
8
Fig. 1: Scope of delivery model 4914.20
1 - top with grate, can be cut to length
2 - sealing collar
3 - insert ring for top
4 - immersion pipe
5 - flange for the application of the bonded sealing
Product information
Advantix Top bath drain 7 from 24

6 - base unit
7 - sound protection mat
8 - adjusting feet
2.3.2 Technical data
Nominal width [DN] (drain
support)
50
Drainage capacity
ÄChapter 2.2.3 „Drainage capacity“
on page 7
Dimensions and installa-
tion height
ÄChapter 3.1.2 „Installation dimen-
sions“ on page 13
Water head seal 30 up to 50 mm
Load class K = 300 kg
2.4 Information for use
2.4.1 Installation variations
The mounting of the drain in a bare concrete floor is as follows:
nThe drain is placed in a floor recess and then cast-in.
Installing in a bare concrete floor
Fig. 2: General installation example – Floor
recess
Product information
Advantix Top bath drain 8 from 24

During the mounting on the floor, the drain is integrated into the floor
construction. At the same time, it can e. g. be integrated into the level-
ling screed or heat insulation. If necessary, a vertical drainpipe can be
led through a drill hole in the floor at the same time.
NOTICE!
The creation of a floor recess must be agreed with the fol-
lowing people:
– a structural engineer
– the on-site fire protection inspector or the specialist
engineer for fire protection
If necessary, proof of compliance with building code or an
expert's report must exist.
2.4.2 Sealing
To protect against moisture penetration, apply sealing foils, which are to
be processed in liquid state, directly below the tiles on screed and
walls. The determination of the stress class and the underground as well
as the selection of the suitable bonded sealing must be carried out in
compliance with the valid standards and regulations, see:
ĄRegula-
tions from section: Sealing“ on page 6
.
The bonded seal can be applied directly onto the drain flange.
Mounting on a floor
Fig. 3: General mounting example – Mounting
on the floor
Bonded sealing
Product information
Advantix Top bath drain 9 from 24

Fig. 4: Diagram of a bonded seal
Careful planning is required for professional sealing. In addition,
depending on the individual dampness wear class and the type of foun-
dation, a suitable BS system with a building regulations certificate of
suitability must be chosen.
Furthermore, the following factors should be taken into account:
nDrain or shower channel must be equipped with a special flange,
which has an adhesive surface and a width of at least 30 mm.
nFor bridging the material change from drain to screed, either a suit-
able sealing collar or sealing tape designed for overlapping with the
BS over a width of at least 50 mm must be used.
nThe screed must be laid at a minimum incline of 1–2 %.
nThe installation must be carried out properly in acc. with the
mounting instructions and the manufacturer's information.
1
9 8 7 6
2 3 4 5
Fig. 5: Construction diagram of the bonded seal - min. screed incline 1–2 %
1 - Grate
2 - Top piece with adhesive flange
3 - Tile
4 - Tile cement
5 - Bonded sealing
6 - Screed
Important note
Product information
Advantix Top bath drain 10 from 24

7 - Sealing collar
8 - Mat
9 - Adhesive flange
In connection with suitable drains, only approved bonded sealings with
proof of practicability in keeping with building law may be used. See
Ä„Regulations from section: Sealing“ on page 6
.
Information regarding the procedure can be found in the instructions for
use of the corresponding product.
2.4.3 Fire protection
Advantix shower channels and drains can both be fitted to be fire proof.
The R120 pipe lead-in can be used for this purpose in the floor con-
struction. In this way, a fire resistance time of up to 120 minutes can be
achieved.
Fig. 6: Example: fire protection pipe lead-in
Mounting instruction of the R120 pipe lead-in see model 4923.5,
Art.-No. 491 673.
Permitted bonded seals
Product information
Advantix Top bath drain 11 from 24

2.5 Required accessories
Advantix tops are available in a number of sizes and variations. You can
also only buy an Advantix top frame and then purchase a suitable
designer grate separately (see catalogue).
The drain can be fitted with a sieve insert (model 4958) to collect dirt.
Top
Sieve insert
Product information
Advantix Top bath drain 12 from 24

3 Handling
3.1 Assembly information
3.1.1 Important note
Before assembly:
nCheck if the drainage capacity of the drain is sufficient for the arising
water volume
ÄChapter 2.2.3 „Drainage capacity“ on page 7
.
nCheck if the installation height of the drain corresponds with the
planned floor construction.
nEnsure that the required connection line is installed with the neces-
sary incline to the planned installation location.
nIf necessary, supply the required accessories
ÄChapter 2.5
„Required accessories“ on page 12
.
During assembly:
nObserve installation dimensions.
After assembly:
nThe drain flange must be fully lined with mortar.
3.1.2 Installation dimensions
Fig. 7: Dimensional drawing model 4914.20
3.1.3 Tools and materials
nTop with grate, if not included in scope of delivery
nMaterial for securing the drain
Required material
Handling
Advantix Top bath drain 13 from 24

3.2 Assembly
3.2.1 Construction and water seal level
Determine screed height.
At a desired installation height of ≥ 105 mm upper edge
sealing flange the floor piece remains in the delivery condi-
tion.
The water seal level is 50 mm and the immersion pipe
length 48 mm.
Loosen clamping ring with screwdriver.
Remove clamping ring and push floor piece in by one ring
(1 x 10 mm).
Installation height 96–105 mm
Handling
Advantix Top bath drain 14 from 24

Align the floor in such a way that the arrows point towards the drain
pipe.
Secure floor with clamping ring.
Tighten the screw of the clamping ring with max. 2.5 Nm ±0.2 Nm.
Alternatively, tighten the end of the clamping ring up to or between
the markings.
ðThe water seal level is 40 mm and the immersion pipe length
38 mm.
Loosen clamping ring with screwdriver.
Installation height 85–95 mm
Handling
Advantix Top bath drain 15 from 24

Remove clamping ring and push floor piece in by two rings
(2 x 10 mm).
Align the floor in such a way that the arrows point towards the drain
pipe.
Secure floor with clamping ring.
Tighten the screw of the clamping ring with max. 2.5 Nm ±0.2 Nm.
Alternatively, tighten the end of the clamping ring up to or between
the markings.
ðThe water seal level is 35 mm and the immersion pipe length
33 mm.
3.2.2 Mount base unit
A few points must be observed to integrate the drain into the floor con-
struction properly. For this reason, proceed as follows to prepare the
drain for subsequent work:
Handling
Advantix Top bath drain 16 from 24

Requirements
nA pipe to the planned drainage position is already in place for the
connection to the waste water system.
nThe drain pipe has an internal sealing lip.
Push the drain support into the drain pipe completely.
Position bathroom drain with sound protection mat on the bare con-
crete floor.
Mount adjusting feet.
Handling
Advantix Top bath drain 17 from 24

Place the adjusting feet into the retaining brackets.
Align bathroom drain horizontally with help of the adjusting feet.
Secure the adjusting feet with dowels and screws supplied.
ðThe bathroom drain can be integrated into the floor construc-
tion.
NOTICE!
Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks
may occur when pressure is applied.
Inform the subsequent workers that the drain must be fully
lined and that there must be no hollow spaces.
Handling
Advantix Top bath drain 18 from 24

3.2.3 Sealing the drain
NOTICE!
Product damage due to improper installation
If hollow spaces occur during the lining of the drain, leaks
may occur when pressure is applied.
Check the proper completion of the subsequent work.
Screed and floor tiles must be laid at an incline of 1–2 % in
the direction of the drain.
Requirements:
nThe flange is free of heavy soil.
nThe complete surface of the flange is lined with material and undam-
aged.
Remove protective foil.
Apply the bonded sealing on the dry screed and spread to the inner
edge of the flange fleece.
NOTICE! Observe the bonded sealing manufacturer's
instructions for use.
Bonded sealing
Handling
Advantix Top bath drain 19 from 24

Lay the sealing collar into the bonded sealing.
Apply a second layer of bonded sealing onto the sealing collar and,
if necessary, onto the floor.
Handling
Advantix Top bath drain 20 from 24
Table of contents
Other Viega Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

Omcan
Omcan 46788 instruction manual

American Standard
American Standard SELECTRONIC 605X.202 installation instructions

Mira
Mira Tabla Installation & user guide

Helvex
Helvex Clasica E-917 installation guide

Spectrum Brands
Spectrum Brands PFISTER Venturi F-042-VN Quick installation guide

Moen
Moen 87581 quick start guide

AM.PM
AM.PM F7500000 Instructions for installation

Grohe
Grohe 30 314 manual

DURAVIT
DURAVIT Circle CE5260 0000 Instructions for mounting and use

KWC
KWC GASTRO 24.501.102 Installation and service instructions

Hans Grohe
Hans Grohe Axor Citterio 39835 1 Series Installation Instructions and Warranty

ZURN
ZURN Camaya Series Installation, operation, maintenance and parts manual