Viega M5 User manual

for drain/overflow functional unit
Model Year built:
6162.01 from 06/2015
en_INT
Multiplex Equipment set M5
Instructions for Use

Multiplex Equipment set M5 2 from 11

Table of contents
1About these instructions for use 4
1.1 Target groups 4
1.2 Labelling of notes 4
1.3 About this translated version 5
2Product information 6
2.1 Intended use 6
2.1.1 Areas of use 6
2.2 Product description 6
2.2.1 Overview 6
2.2.2 Equipment versions 7
3Handling 8
3.1 Assembly information 8
3.1.1 Mounting conditions 8
3.1.2 Required tools and materials 8
3.2 Assembly 8
3.2.1 Replacing the fixing flange 8
3.2.2 Mounting equipment set 9
3.3 Control 10
3.4 Maintenance 11
3.5 Disposal 11
Table of contents
Multiplex Equipment set M5 3 from 11

1 About these instructions for use
Trade mark rights exist for this document, further information can be
found at www.viega.com/legal-notices.
1.1 Target groups
The information in this instruction manual is directed at the following
groups of people:
nHeating and sanitary professionals and trained personnel
nOperators
nConsumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, service this product. This
restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
About these instructions for use
Multiplex Equipment set M5 4 from 11

1.3 About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The pertinent national laws, stand-
ards, regulations and guidelines, as well as other technical guidelines,
have priority over German/European guidelines in this manual: The
information is not binding for other countries and territories and should,
as mentioned, be considered as support.
About these instructions for use
Multiplex Equipment set M5 5 from 11

2 Product information
2.1 Intended use
2.1.1 Areas of use
The equipment set is exclusively suitable for use with a Multiplex drain /
overflow for bathtubs with a 52 mm drain hole.
The model described here cannot be combined with Multi-
plex Trio products. Separate equipment sets with other
model numbers are available for the Multiplex Trio inlets /
drains / and overflows.
2.2 Product description
2.2.1 Overview
The following components are included in the scope of delivery of the
equipment set:
Product information
Multiplex Equipment set M5 6 from 11

234
5
1
Fig. 1: Component overview
1 - mounting aid
2 - rotatable rosette
3 - fixing flange
4 - valve cone
5 - O-ring
2.2.2 Equipment versions
The model is available in the following versions:
Version Article number
chrome-plated 721 244
chrome matt / velour chrome 735 906
stainless steel colours / brushed 735 890
designer white 735 883
Product information
Multiplex Equipment set M5 7 from 11

3 Handling
3.1 Assembly information
3.1.1 Mounting conditions
There are two possible installation situations for the equipment set:
nThe equipment set should be replaced in an existing installation.
nIn the case of a new installation, the equipment set is fitted onto a
functional unit.
In the first case, carry out all of the steps of the installation as described
below.
In the second case, make sure that the fixing flange corresponds
exactly with the model supplied. If the correct fixing flange is installed,
you can dispose of the mounting aid, the O-‑ring and the fixing flange
and start with the second mounting step (
ÄChapter 3.2.2 „Mounting
equipment set“ on page 9
).
3.1.2 Required tools and materials
The following tools are required for mounting:
nmounting aid (included in the scope of delivery)
nslotted screw driver
No additional material is required for the complete mounting of the
product.
3.2 Assembly
3.2.1 Replacing the fixing flange
The mounting aid serves the purpose of securing the over-
flow when the fixing flange is removed. For this reason, the
mounting aid must be held in the hand for the entire
replacement procedure.
If the equipment set is to be mounted on an older model of the Multiplex
drain/overflow, the fixing flange for the rotatable rosette must be
replaced first. Proceed as follows:
Tool
Material
Handling
Multiplex Equipment set M5 8 from 11

Requirements:
nAn older Multiplex model is installed.
nThe rotatable rosette has been removed.
Push the mounting aid through the middle hole of the fixing flange.
Screw the mounting aid in a clockwise direction into the overflow
unit.
Hold the overflow in place using the mounting aid.
Unscrew the fixing flange in an anti-clockwise direction.
Remove and dispose of fixing flange and O-ring.
Mount new O-Ring onto the new fixing flange.
Push the new fixing flange over the mounting aid and fit in the over-
flow unit.
Tighten the fixing flange in a clockwise direction.
Unscrew the mounting aid in an anti-clockwise direction and
remove.
3.2.2 Mounting equipment set
To avoid damage to the rosette and valve cone, only mount the equip-
ment set after finishing all other work on the building site. Proceed as
follows:
Handling
Multiplex Equipment set M5 9 from 11

Align and fit rotatable rosette.
Fit valve cone.
Turn rotatable rosette to check function and alignment.
The opening of the valve cone should be 2–3 cm wide when
opened. If necessary, regulate the width of the opening of the valve
cone using the adjusting screw (see next step).
Set the valve cone with the help of the adjusting screw and counter
with union nut.
3.3 Control
The drain / overflow are controlled via rotatable rosette on the overflow.
Proceed as follows to open or close the drain:
Turn rotatable rosette to the left.
ðThe drain closes itself.
Handling
Multiplex Equipment set M5 10 from 11

Turn rotatable rosette to the right.
ðThe drain opens itself.
3.4 Maintenance
NOTICE!
Risk of damage due to unsuitable cleaning agent.
The following cleaning agents can damage chrome-plated
surfaces and therefore may not be used:
– scouring agent
– abrasive sponges
– lime, plaster or cement dissolver
– solvents or other acidic cleaning agents
Normal soap or a mild cleaning agent can be used for regular care and
prevention of lime scale on the rotatable rosette and valve cone. Under
no circumstances should scouring agent or scratching objects be used.
Strong stains, even around the drain unit and the siphon, can be
removed using typical household cleaner. It should be noted that the
cleaning agent should be rinsed off after the prescribed soaking time.
There should be no residue on the components.
3.5 Disposal
Separate the product and packaging materials (e. g. paper, metal,
plastic or non-ferrous metals) and dispose of in accordance with valid
national legal requirements.
Handling
Multiplex Equipment set M5 11 from 11
Table of contents
Other Viega Kitchen & Bath Fixture manuals
Popular Kitchen & Bath Fixture manuals by other brands

Omcan
Omcan 46788 instruction manual

American Standard
American Standard SELECTRONIC 605X.202 installation instructions

Mira
Mira Tabla Installation & user guide

Helvex
Helvex Clasica E-917 installation guide

Spectrum Brands
Spectrum Brands PFISTER Venturi F-042-VN Quick installation guide

Moen
Moen 87581 quick start guide

AM.PM
AM.PM F7500000 Instructions for installation

Grohe
Grohe 30 314 manual

DURAVIT
DURAVIT Circle CE5260 0000 Instructions for mounting and use

KWC
KWC GASTRO 24.501.102 Installation and service instructions

Hans Grohe
Hans Grohe Axor Citterio 39835 1 Series Installation Instructions and Warranty

ZURN