Voltex VDEF-250 Operation manual

Installation
& User Guide
Voltex Side Ducted Flush Mounted
Square Ceiling Exhaust Fan
VDEF-250
VDEF-300
220-240V~; 50Hz; 30W (VDEF-250) or 35W (VDEF-300)
in White (-W) or Silver (-S)
IMPORTANT: PLEASE READ AND SAVE THESE INSTRUCTIONS
II300317

Thank you for your purchase of the Voltex Side Ducted, Flush Mounted, Square
Ceiling Exhaust Fan (appliance). Please read these instructions carefully before
installing and using the appliance. Keep the instructions handy for future
reference.
IMPORTANT: This appliance must be installed in accordance with national and
local council building regulations, and the Australian and New Zealand wiring rules
AS/NZS 3000 latest edition thereof.
ALL ELECTRICAL WORK MUST BE CARRIED OUT BY A LICENSED ELECTRICAL
CONTRACTOR OR ELECTRICIAN.
CAUTION: The appliance should not be installed directly above a bath, shower or
fixed water container. The appliance must not be installed in a position where water
may splash onto the appliance.
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE
To reduce the risk of fire, electrical shock or injury to persons or property:
1. Use this appliance only as described in this manual. Any other use not
recommended by Voltex Electrical may cause fire, electric shock, or injury
to persons and void the warranty. If you have questions, please contact
Voltex Electrical at first.
2. Always operate the appliance from a power source of the same rated
voltage, frequency and power input as indicated on the appliance
identification place.
3. This appliance is intended for household use and similar applications only.
It is not suitable for use in an environment heavily laden with dust.
4. This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
5. Do not operate any appliance with a damaged cord or plug, or after the
appliance malfunctions, or is dropped or appears damaged in any way.
6. There are no user-serviceable parts inside the appliance. Contact your
local electrician if servicing or maintenance is required.
© Voltex Electrical 2016. All Rights Reserved.
®
GENERAL SAFETY WARNINGS
IMPORTANT INSTALLATION, USER & WARRANTY INSTRUCTIONS

IMPORTANT CONSIDERATIONS BEFORE INSTALLING
© Voltex Electrical 2016. All Rights Reserved.
®
A few minutes planning can make a big difference to the installation time and to
your satisfaction with the function of the appliance.
1. For the exhaust fan to work efficiently, replacement air of a volume
equivalent to what is being extracted must be able to enter the room. In
general, this air would be drawn under the door, or through a slightly open
window. If the room is airtight, the fan will function poorly.
2. This appliance is designed for installation in flat ceilings ONLY. Do not
mount it on a sloping ceiling or a vertical wall.
3. Before commencing any cutting, check that there are no obstructions
such as ceiling joists and that there is sufficient height clearance or the
housing and routing of the duct. Check that the electrical wiring can be
routed from the wall switches to the mounting location.
7. If the supply cord is damaged, it must be replaced by your local electrician
or similarly qualified pe son in order to avoid a hazard.
8. This appliance is designed for indoor use only.
9. Do not allow any foreign object to enter through the facia opening or outlet
as this may damage the appliance and/or the user.
10. The appliance shall, under no circumstances, be covered with insulating
material or similar material.
11. Make sure that the power is OFF before installation.
12. When cutting into the mounting surface, do not damage electrical wiring
and other hidden utilities.
13. The appliance must be properly connected to the protective earthing
conductor in the fixed wiring of the installation.
14. Precautions must be taken to avoid the back-flow of gases into the room
from the open flue of gas or other fuel-burning appliances
15. FOR SAFE USE OF THIS APPLIANCE, AFTER INSTALLATION, DISCONNECTION
OF THE APPLIANCE FROM THE SUPPLY SHALL BE POSSIBLE. THIS
MAY BE ACHIEVED BY HAVING THE PLUG ACCESSIBLE OR MEANS FOR
ALL POLE DISCONNECTION MUST BE INCORPORATED IN THE FIXED WIRING
IN ACCORDANCE WITH THE WIRING RULES.

© Voltex Electrical 2016. All Rights Reserved.
®
Remove all packaging from the appliance before commencing installation. Ensure
the circuit has been isolated from the mains supply BEFORE commencing work.
1. Locate in accordance with the requirements of the wiring rules relating to
damp situations. national and local council regulations concerning the
discharge of air must be fulfilled.
2. For installation where external venting is required or is your choice,
select a suitable location in the exterior side wall or under the eave to vent
out the exhausted air/steam and cut out a Φ105mm hole. NOTE: Make
sure the ducting will reach from the centre of installation of the appliance
to the external vent.
3. Put one end of the 100mm ventiduct through the hole and secure the duct
to a suitable outlet grill and if necessary seal the join with duct tape and
seal space around the hole using a suitable sealant where necessary. Fix
the outlet grill to the wall/eave.
4. Choose a suitable mounting location in the ceiling. Note it should not be
where it may come into contact with water for example above a shower or
bath. Centre of room is ideal. If not, at least 250mm from a wall.
5. Use the template card provided as a hole cutting template
(VDEF-250: 210mmx210mm or VDEF-300: 250mmx250mm).
6. Do not install above or adjacent to a cooking appliance.
7. The fan is intended to be mounted at high level and must be installed so
that the blades are more than 2.1m above the floor.
8. CAUTION: Ensure that the intended hole will have suitable room to locate
the unit and that it will not interfere with joists or the ceiling structure.
Joists, beams and rafters shall not be cut or notched to install the appliance
9. There must be adequate clearances. Make sure a minimum of 250mm is
maintained between the appliance and any wall. There should be a
minimum of 300mm height clearance in the ceiling for objects above the
housing. A minimum of 30mm clearance is required around the hole for the
fan, the vertical sides of the appliance and any adjoining parts of the roof
structure, such as joists or insulation batts. Refer also Figure 1. Dimensions
below.
10. The installation wiring shall terminate at a suitable socket outlet with an
earthing contact installed near the fan. This must be located within the
length of the supply cord and plug from the fan.
11. Use the template card provided as a hole cutting template to mark out the
intended hole for mounting the appliance (it may be safer to mark the
position from above the ceiling where obstructions are clearly visible,
rather than from inside the room).
INSTALLATION

© Voltex Electrical 2016. All Rights Reserved.
®
Model Dimension A (mm) Dimension B (mm) Dimension C (mm)
VDEF-250 236 236 150
Fascia 242 242 -
Cut Dimension 210 210 -
VDEF-300 285 285 180
Fascia 308 308 -
Cut dimension 250 250 -
12. Carefully cut around the line. Several holes drilled at a point inside the
marking will provide a convenient starting point for cutting the panel out.
13. Remove the facia of the exhaust fan by pushing the spring on each side
together and then guide it through the slot.
14. There are four mounting clips. Loosen the screw on each mounting clip and
slide all four clips toward the body of the exhaust fan (centre).
15. The exhaust fan is supplied with a supply cord and plug.
16. Check power to the socket outlet is isolated from the mains power supply
and plug the fan into the socket outlet.
17. Insert fan into hole.
18. Push the four mounting clips outwards. When the clips are fully extended,
tighten the screw on each mounting clip to lock the clip and exhaust fan in
place.
19. Replace the fascia by pushing the spring on each side together and guiding
it back through the slot.
20. Attach the free end of the ducting to the outlet of the appliance.
21. WARNING: The appliance shall, under no circumstances, be covered with
insulating material or similar material.
22. Reconnect power to the socket outlet.
23. Switch on appliance and check correct function and switch operation.
24. Your installation is now complete.

WARRANTY & SERVICE
Voltex warrants all its ceiling fans against defective workmanship and faulty
materials for twenty-four (24) months from the date of purchase. Please retain
proof of purchase and evidence of installation by a licensed electrician.
Voltex undertakes, at its option, to repair or replace, free of charge, each
appliance or part. Contact Voltex Electrical on 1300 722 275 (Australia) or
0800 55 66 33 (New Zealand) for any warranty claims.
®
Voltex Electrical 2015. All Rights Reserved.
P: 1300 722 275 E: [email protected]
Australia
P: 0800 55 66 33 E: [email protected]
New Zealand
www.voltexelectrical.com.au
www.voltexelectrical.co.nz
Voltex Electrical
This manual suits for next models
1
Table of contents
Popular Ventilation Hood manuals by other brands

Electrolux
Electrolux EFT739X user manual

Streamline
Streamline ISLAND Series Installation Instructions, Maintenance, Use and Warranty

Tisira
Tisira TUM52SS user manual

Smeg
Smeg K143X Installation, use and maintenance manual

ROSIERES
ROSIERES RDV980PN instruction manual

Windster
Windster WINT024 Installation guide and user's manual