Voltmaster VI770 User manual

Model VI770
Digital Inverter Generator
User’s Manual
January 2015

Thank you for purchasing a Voltmaster® inverter generator.
This manual covers operation and maintenance of the VI770 generator.
All information in this publication is based on the latest product information
available at the time of approval for printing.
We reserve the right to make changes at any time without notice and without
incurring any obligation.
No part of this publication may be reproduced without written permission.
This manual should be considered a permanent part of the generator and should
remain with it if it is resold.
Pay special attention to statements preceded by the following words;
Failed to properly follow these precautions can result in
property damage, serious injury or DEATH
Read all labels and the owner's manual before operating
this generator.
Operate only in well ventilated areas. Exhaust gas
contains poisonous carbon monoxide, and can be
deadly. Always stop engine before refueling. Wait 5
minutes before restarting.
Check for spilled fuel or leaks. Clean and/or repair
before use.
Keep any sources of ignition away from fuel tank, at all
times.
Indicates a strong possibility of severe personal injury or
death if instructions are not followed.
Indicates a possibility of personal injury or equipment
damage if instructions are not followed. If a problem
should arise, or if you have any questions about the
generator, consult an authorized dealer.
Our generators are designed to give safe and
dependable service if operated according to instructions.
Read and understand the Owner's Manual before
operating the generator. Failure to do so could result in
personal injury or equipment damage.
PREFACE
WARNING
WARNING
CAUTION
WARNING

CONTENTS
1. Safety Instructions
2. Safety Label Locations
3. Component Indentificaction
4. Pre-operation Check
5. Starting the Engine
6. Generator Use
7. Stopping the Engine
8. Maintenance
9. Transporting/Storage
10. Troubleshooting
11. Specifications
12. Electric diagram
--
1
3
4
5
9
12
16
18
25
27
29
30
11. SPECIFICATIONS
IG770
50
230
3.04
6000
0.70
0.77
60
240
2.92
KG140
37.68ml (40 30mm)
8.5:1
1.00/6000
6000
T.C.I
UR5
Recoil starter
Automotive unleaded gasoline
450
CD grade or SAE 10W/30
Fuel tank capacity (L)
Continuous running time (hr) (at rated output)
Noise level (zero load-full load) [dB(A)/7m]
Overall dimension (LxWxH) [mm(in)]
Dry weight [kg(lbs)]
1.55
3
60-65 *
410 220 360
10.5
Rated frequency (Hz)
Rated voltage (V)
Rated current (A)
Rated rotation speed [r/min]
Rated output (kVA)
Max. output (kVA)
Model
Model Type
Type
Displacement (BorexStroke)
Compression ratio
Rated power [kW(Hp)/(r/min)]
Rated rotation speed [rpm]
Ignition system
Spark plug
Starting system
Fuel
Fuel consumption (g/kW.h)
Lube oil
Single cylinder, 4 stroke, air-cooled, vertical,OHV
Engine
60
120
5.82
*The declared values shall consider uncertainties due to production variation and
measurement procedures.

--
WARNING
Operate carefully to ensure safety.
1. SAFETY INSTRUCTIONS
WARNING
Our generators are designed to give safe and
depend-able service if operated according to
instructions.
Read and understand the Owner's Manual before
operating the generator. Failure to do so could result
in personal injury or equipment damage.
WARNING
WARNING
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area.
Be sure to provide adequate ventilation.
The muffler becomes very hot during operation and
remains hot for a while after stopping the engine.
Be careful not to touch the muffler while it is hot.
The engine exhaust system will be heated during
operation and remain hot immediately after stopping
the engine.
To prevent scalding, pay attention to the warning
marks attached to the generator.
Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine stopped.
Keep away from cigarette, smoke and sparks when re-fueling the
generator. Always refuel in a well-ventilated location.
Wipe up spilled gasoline at once.
Usage of generator should be limited in ambient where the risk of fire may
be high.
WARNING

--
WARNING
WARNING
Connections for standby power to a building's electrical system must be
made by a qualified electrician and must comply with all applicable laws and
electrical codes. Improper connections can allow electrical current from the
generator to back feed into the utility lines. Such back feed may electrocute
utility company workers or others who contact the lines during a power
outage, and when utility power is restored, the generator may explode, burn,
or cause fires in the building's electrical system.
Always make a pre-operation inspection before you start the engine. You
may prevent an accident or equipment damage.
Place the generator at least 1m(3ft) away from buildings or other
equipment during operation.
Operate the generator on a level surface.
If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all
the controls. Never permit anyone to operate the generator without proper
instructions.
Keep children and pets away from the generator when it is in operation.
Keep away from rotating parts while the generator is running.
The generator is a potential source of electrical shocks when misused; do
not operate with wet hands.
Do not operate the generator in rain or snow and do not let it get wet.

--
2. SAFETY LABEL LOCATIONS
Chock handle
Oil level
Model
Safety caution
Hot caution
Engine switch Air inlet
These labels warn you of potential hazards that can cause serious injury. Read
the labels and safety notes and precautions described in this manual carefully.
If a label comes off or becomes hard to read, contact your dealer for a
replacement.

--
3. COMPONENT IDENTIFICATION
Chock lever
Engine switch
Fuel cap lever
Oil filler cap
Spark plug
maintenance
cover
Muffler
Maintenance cover
Starter grip
Control panel

--
Output indicator light
Overload indicator light
Low oil alarm indicator light
AC receptacle
Smart switch
Ground terminal
NOTE
Smart throttle
switch
ON OFF
Control panel
SMART throttle:
Engine speed is kept at idle automatically when the electrical appliance is
disconnected and it returns to the proper speed to power of the electrical load
when electrical appliance is connected. This position is recommended to
minimize the fuel consumption while in operation.
OFF:
Note: Smart throttle system does not operate. Engine speed is kept at thigh-
speed lever.
Smart throttle system does not operate effectively if the electrical
appliance requires the big electric power.
When high electrical loads are connected simultaneously turn the smart
throttle switch to the OFF position to re-duce voltage changes.

--
4. PRE-OPERATION CHECK
Be sure to check the generator on a level surface with the engine stopped.
1. Check the engine oil level.
CAUTION
-25 -30
-15 -40
10W-30
15W-40
Ambient temperature Engine oil type
Using nondetergent oil or 2-stroke engine oil could shorten the engine's
service life.
Use a high-detergent, premium quality 4-stroke engine oil, certified to
meet or exceed U.S. automobile manufacturer's requirements for API
Service Classification SG/SF.
Select the appropriate viscosity for the average temperature in your area.
SAE Viscosity Grades
CAUTION
CAUTION
Store and use the oil carefully in order to prevent dust or dirty flowing into
the oil. If oil is overfilled, wipe it up at once.
Never mix different kinds of oil.
Remove and wipe the dipstick with a clean rag. Check the oil level by inserting
the dipstick in the filler hole without screwing it in.
If the oil level is below the end of the dipstick, refill the recommended oil up to the
top of the oil filler neck.
Running the engine with insufficient oil can cause serious engine damage.
The Low Oil Alarm System will automatically stop the engine before the oil
level falls below the safe limit. However, to avoid the inconvenience of an
unexpected shutdown, it is still advisable to visually inspect the oil level
regularly.

--
Upper lever
Upper limit
Lower limit
Oil rule
Oil filler hole
2. Check the fuel level.
Use automotive gasoline (Unleaded or low-leaded is preferred to minimize
combustion chamber deposits).
If the fuel level is low, refuel the fuel tank until the level as specified.
Never use an oil/gasoline mixture or dirty gasoline.
Avoid getting dirt, dust or water in the fuel tank.
After refueling, tighten the oil rule seurely.
WARNING
Gasoline is extremely flammable and is explosive under certain conditions.
Refuel in a well-ventilated area with the engine stopped.
Do not smoke or alow flames or sparks in the area where the engine is
refueled or where gasoline is stored.
Do not overfill the fuel tank (there should be no fuel above the upper limit
mark). After refueling, make sure the tank cap is closed properly and
securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may
ignite, if any fuel is spilled, make sure the area is dry before starting the
engine.
Avoid repeated or prolonged contact with skin or breath-ing of vapor,
KEEP OUT OF REACH OF CHILDREN.
Upper limit mark
Fuel tank capacity: 1.55L
CAUTION
Fuel filler cap Open

Gasoline containing alcohol
If you decide to use a generator containing alcohol (gasohol), be sure it's octane
rating is at least as high as that recommended by us. There are two types of
gasohol: one containing ethanol, and the other containing methanol. Do not use
gasohol that contains more than 10% ethanol. Do not use gasoline containing
methanol (methyl or wood alcohol) that does not also contain cosolvents and
corrosion inhibitors for methanol. Never use gasoline containing more than 5%
methanol, even if it has cosolvents and corrosion inhibitors.
3.Check the air cleaner.
Check the air cleaner element to be sure it is clean and in good condition.
Loosen the cover screw and remove the left side maintenance cover. Press the
latch tab on the top of the air cleaner body, remove the air cleaner cover, check
the element. Clean or replace the element if necessary.
CAUTION
CAUTION
Fuel system damage or engine performance problems resulting from the
use of fuel that contain alcohol is not covered under the warranty. We cannot
endorse the use of fuels containing methanol since evidence of their
suitability is as yet incomplete.
Before buying fuel from an unfamiliar station, try to find out if the fuel
contains alcohol. If it does, confirm the type and percentage of alcohol used.
If you notice any undesirable operating symptoms while using a gasoline
that contains alcohol, or one that you think contains alcohol, replace it by a
gasoline that you know does not contain alcohol.
Never run the engine without the air cleaner. Rapid engine wear will result
from contaminants, such as dust and dirt, being drawn through the
carburetor, into the engine.
Maintenance cover
Screw
Air filter
Air filter element
Air filter cover
Foam filter
element
-8-

--
5. STARTING THE ENGINE
Fuel cap lever
ON
Engine switch
CAUTION
Before starting the engine, disconnect the load from the DC terminals.
When starting the generator after adding fuel for the first time or after long
term storage, or after running out of fuel, turn the fuel valve lever to the ''
ON'' position, then wait for 10 to 20 seconds before starting the engine.
1. Turn the fuel cap lever fully clockwise to the ON position.
Note: Turn the fuel cap vent lever to the OFF position when transporting generator.
2. Turn the engine switch to the On position.
ON
OFF
ON

Run
--
3.Move the choke lever to the START position.
Note: Do not use the choke when the engine is warm or the air temperature is high.
4. Pull the starter grip until resistance is felt, then pull the starter grip briskly toward
the arrow as shown below.
Do not allow the starter grip to snap back, return it slowly by hand.
Run
Choke lever
CAUTION
Starter grip

--
5. Move the choke lever to the RUN position after the engine warms up.
Run
Choke lever
Run
CAUTION
If the engine stops and will not restart, check the engine oil level before
troubleshooting in other areas.
High altitude operation
At high altitude, the standard carburetor air-fuel mixture will be excessively rich.
Performance will decrease, and fuel consumption will increase.
High altitude performance can be improved by installing a smaller diameter main
fuel jet in the carburetor and readjusting the pilot screws. If you always operate
the generator at altitudes higher than 1,500m (5,000 feet) above sea level, have
your authorized dealer perform these carburetor modifications.
Even with suitable carburetor jetting, engine horsepower will decrease
approximately 3.5% for each 305m (1,000 feet) increase in altitude. The affect of
altitude on the horsepower will be greater than this if no carburetor modification is
made.
CAUTION
Operation of the generator at an altitude lower than the carburetor is jetted
for may result in reduced performance, overheating, and serious engine
damage caused by an excessively lean air/fuel.

--
6. GENERATOR USE
WARNING
To prevent electrical shock from faulty appliances, the generator should
be grounded. Connect a length of heavy wire between the generator's
ground terminal and an external ground source.
Connections for standby power to a building's electrical system must be
made by a qualified electrician and must comply with all applicable laws and
electrical codes. Improper connections can allow electrical current from the
generator to backfeed into the utility lines. Such backfeed may electrocute
utility company workers or others who contact the lines during a power
outage, and when utility power is restored, the generator may explode, burn,
or cause fires in the building's electrical system.
CAUTION
Maximum power would be available for the first 30 minutes.
For continuous operation, do not exceed the rated power.
Do not exceed the current limit specified for any one receptacle.
Do not connect the generator to a household circuit. This could cause the
damage to the generator or to electrical appliances in the house.
Do not modify or use the generator for other purposes than it is intended
for. Also observe the following when using the generator.
A. Do not connect generators in parallel.
B. Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use a tough rubber
sheathed flexible cable.( IEC245
2
Limit length of extension cables: less than 60 m for cables if 1.5 mm and
2
less than100m for cables of 2.5 mm .
Keep the generator away from other electric cables or wires such as
commercial power supply lines.
CAUTION
Electrical equipment (including electrical lines and plugs connection)
could not be defective.

--
Output indicator light(green)
Overload indicator
light(red)
Smart switch
Plug
AC applications
1.Start the engine and make sure the output indicator light (green) comes on.
2.Confirm that the appliance to be used is switched off, and plug in the appliance.
CAUTION
Be sure that all appliances are in good working order before connecting
them to the generator. If an appliance begins to operate abnormally,
becomes sluggish, or stops suddenly, turn off the generator engine switch
immediately. Then disconnect the appliance, and examine it for signs of
malfunction.
3. In order to acquire both the best effect and the maximum service life of the
generator. Usually, the new generator should run 20 hours under 50% load, the
generator may reach the best performance.
Output and Overload Indicators
The output indicator light(green)will remain ON during normal operating
conditions.
If the generator is overloaded(in excess of 1.0kVA), or if there is a short in the
connected appliance, the output indicator light(green) will go OFF, the overload
indicator light(red) will go ON and current to the connected appliance will be shut
off.
Stop the engine if the overload indicator light (red) comes ON and investigate the
overload source.

--
1. Connect the ground terminal.
Grounding terminal
CAUTION
CAUTION
Before connecting an appliance to the generator, check that it is in good
order, and that its electrical rating does not exceed that of the generator.
Then connect the power cord of the appliance, and start the engine.
Indicator lights (both red and green) may come ON during generator
starting. It is normal if the red indicator light goes off after 4 seconds, if not,
please contact your dealer.
2. Start each engine according to "STARTING THE ENGINE".
When the output indicator light(green)does not light and the overload indicator
light (red) lights instead, set the engine switch to STOP, stop the engine at once
and then start the engine again.
3. Confirm that the equipment to be used is switched off, and insert the plug
of the equipment to be used into the AC receptacle
CAUTION
Confirm that the use equipment to be connected is switched off. When the
equipment to be used is switched on, it will operate suddenly, and injuries or
accidents may be caused.

4. Switch on the equipment to be used.
In case of overload operation or when trouble occurs for the equipment being
used, the output indicator light(green) will go out, the overload indicator light(red)
will light continuously, and no power will be put out.
At this time, the engine will not stop, so that the engine must be stopped by
setting the respective engine switch to STOP.
Low oil alarm system
The Low oil alarm system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
falls below a safe limit, the Low oil alarm system will automatically shut down the
engine (the engine switch will remain in the ON position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator
light(red) will come on when you operate the starter, and the engine will not run. If
this occurs, add engine oil.
--
Output indicator light (green)
Low oil alarm
indicator (red)
Overload indicator
light (red)
CAUTION
When equipment requiring a large starting power, like a motor etc., is used,
the overload indicator light (red) and the output indicator light(green)may
light together for a short time (about 4 sec), but this is no abnormality. After
start of the equipment, the overload indicator light (red) will go out and the
output indicator light(green) will stay lit.

--
7. STOPPING THE ENGINE
Engine switch
Plug
OFF~
To stop the engine in an emergency, turn the engine switch to the OFF position.
IN NORMAL USE:
1. Switch off the connected equipment and pull the inserted plug.
2 .Turn the engine switch to the OFF position.

--
3.Turn the cap lever fully counterclockwise to the "OFF"position
OFF
Fuel cap lever
Be sure the fuel cap lever, choke and the engine switch are "OFF" when
stopping, transporting and/or storing the generator.
CAUTION
Table of contents
Other Voltmaster Portable Generator manuals
Popular Portable Generator manuals by other brands

Champion
Champion 46515 Owner's Manual and Operating Instructions

Sumo
Sumo SMK35GEN Safety and operating manual

Coleman
Coleman Powermate PM0106004 Operator's manual

Active Technologies
Active Technologies AT-1120 user manual

Winco
Winco W10PTOS/A Installation and operator's manual

National Instruments
National Instruments PXIe-5655 SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION