Claind Nitro70 User manual

User’s manual
Nitrogen
Generators
Nitro35
Nitro70

2
Table of contents
1. Introduction 3
2. Safety 4
3. Description of the generator 6
4. Installation 9
. Disassembly and transport 17
6. Use 18
7. Maintenance 24
8. Troubleshooting 26
9. Guarantee 27
10. Declaration of conformity 28
11. Notes 29

Nitrogen Generators Nitro35 Nitro70
3
1.
Introduction
This document is intended for users of Nitrogen generators model Nitro3 and
Nitro70 and provides all information regarding installation, use, maintenance,
and guarantee.
With regard to installation and maintenance, it is presumed that the user is expe-
rienced in the use of pneumatic components, and in particular is aware of all sa-
fety aspects linked to the use of compressed air and nitrogen.
The margin of the text contains the following symbols, indicating:
m
compulsory safety standards to be observed
c
electrical hazard
e
recommendations and important information
It is strongly recommended to carefully read all safety warnings (
par. 2.1.
)
before carrying out any operation on the generator.

Safety
4
2.
Safety
These generators can be installed next to the users without having to classify
the nearby area as “dangerous”, since it has been designed with all the neces-
sary precautions to guarantee maximum safety.
e
The unit must be installed and used in observance of the instructions in this
booklet. Furthermore, use of the generator must be limited to that described in
Chapter 1 Introduction
. Failure to observe the foregoing will render the
guarantee null and void and release CLAIND from all liability for direct or indirect
damage or physical injury.
e
The user is responsible for asking local authorities if there are local safety
regulations that are stricter than what is described in this manual.
2.1.
arnings
m
Place the generators FAR FROM SOURCES OF HEAT
m
Place the generators in an environment PROTECTED AGAINST RAIN
AND IND
c
NEVER OPEN the generator while it is connected to the electrical
mains: RISK OF FATAL INJURY BY ELECTROCUTION
e
Repairs and inspections must be carried out exclusively by QUALIFIED
PERSONNEL: in the event of faults which cannot be resolved according to the
procedures listed in the TROUBLESHOOTING chapter, contact exclusively our
authorized Technical Assistance.
e
If the generator has not to be used for a prolonged period of time, it must be
depressurised (par. 6. .)
2.2.
Consideration on the use of nitrogen
Nitrogen isn’t a toxic gas, but when the percentual content of the air exceed de-
terminated values suffucation risk can occur.
We recommend therefore to not breath the gas directly and not to work in the
nearby of the Nitrogen flux.
Due to the low quantities of Nitrogen produced, a normally ventilated enviro-
ment is anyway sufficient to prevent the accumulation risk.

Nitrogen Generators Nitro35 Nitro70
2.3.
Safety devices
m
MAXIMUM PRESSURE:
The maximum applicable compressed air pressure to generators is 10 bar. Ple-
ase pay attention that this value doesn’t exceed in order to avoid explosion risk
due to the structural failure of the components.
Pressure in the built-in reservoir is limited by a safety valve.
2.4.
Technical assistance
e
CLAIND disclaims any liability for any damages caused from improper use of the
generator.
Please contact CLAIND Service center before of any kind of intervention.
CLAIND technical assistance can be contacted as follows:
Phone ++39 0344 6603
Fax ++39 0344 6627
e-mail: service@claind.it

Description of the generator
6
3.
Description of the generator
3.1.
Equipment supplied
Unless differently agreed, the supply includes:
• n°1 Nitrogen generator model Nitro3 or Nitro70;
• n°1 certificate of conformity of tank and safety valve, that you can found inside
the generator;
• n°1 cable for the electrical mains;
• n°2 male fitting for plastic tube external diameter=10mm;
• n°1 CD user’s manual;
• n°2 eyebolts for lifting the generator;
• n°4 feet;
• n°4 stabilizer brackets;
• n°8 screw diameter 6mm, lenght 20mm;
• n°8 washers.
3.2.
Technical specifications
3.2.1.
General requirements
* with the exception of a peak of 63 dBA for second every minute.
Dimensions Width 26, cm
Depth 7 cm
Height 92 cm
eight of Nitro35 7 kg
eight of Nitro70 90 kg
Packing dimensions Width 80 cm
Depth 120 cm
Height 11 cm
Gross weight of Nitro35 9 kg
Gross weight of Nitro70 110 kg
Noise (1m from the front panel) 0 dBA*
orking temperature from °C to 40°C
Protection rating IP20

Nitrogen Generators Nitro35 Nitro70
7
3.2.2.
Electrical requiremets
3.2.3.
Gas
Flow rate and purity degree of nitrogen outlet vary depending on the kind of uti-
lization and of application. The technical specification of this model are indicated
on the related product sheet.
Supply voltage 230 V~ (±10%); 1ph; 0Hz
Nominal power 30 W

Description of the generator
8
3.3.
Generator components
3.3.1.
Frontal view
3.3.2.
Rear view
A. ALPHANUMERIC DISPLAY AND
KEYPAD: they indicate the alarm and
operative condition; the four keys
allow to display and set the working
parameters.
B. NITROGEN GAUGE: it indicates the
outlet Nitrogen pressure
C. “POWER” KEY: it is the power switch.
D. AIR GAUGE: it indicates the
compressed ari pressure of the intake
line of the generator
E. PRESSURE REGULATOR: it allows to
set the outlet Nitrogen pressure
A. LABEL: it shows the identificative data
of the generator and the power supply
data.
B. CONNECTORS for the power supply
cable; it includes the main FUSE
lodging, whose characteristics are
indicated in the “F” label.
C. NITROGEN: pneumatic connection
(G 1/4’’ female) for nitrogen line to be
connected to the user.
D. AIR: pneumatic connector for
compressed air line (G 1/4’’ female)
E
C
A
D B
C D
A B

Nitrogen Generators Nitro35 Nitro70
9
4.
Installation
4.1.
Installation preparation guide
4.1.1.
Moisture and particulate
In order to avoid damages to the electronic components, we recommend to in-
stall the generator in a area where the relative moisture and the dust concentra-
tion are limited.
Moreover, the generator must be protected from dripping, rain and wind.
4.1.2.
Temperature
Environmental temperature of the area of the installation must be between °c
and 40°c.
Please avoid proximity to heat sources. Please avoid the direct exposition to sun
beams.
4.2.
Generator positioning
4.2.1.
Handling
The packed generator can be handled using an adequate instrumentation, such
as a transpallet or a fork lift. Once unpacked, it can be moved by his own wheels.
m
If suddenly moved the generator could fall and generate damage to
things or persons.
e
The generator must be always kept in vertical position since it has not been de-
signed to be layed down.
4.2.2.
Unpacking
The generator is shipped on a dedicated pallet.
Please remove packing paying attention not to damage the panels of the gene-
rator.
When possible, please keep the original packing to guarantee an adequate pro-
tection of the generator in case of future handling.

Installation
10
4.2.3.
Remove the generator from the pallet
The generator removal from the pallet can be performed using the two eyebolts
included in the supply. These must be mounted on the top of the generator in-
stead of the two black plastic screws (following picture).
4.2.4.
Positioning
The choice of the installation area of the generator must consider a minumum
access space for the user and for the maintenance: we reccomend to let a free
space of at least 0 cm both from the front panel and from the back panel.
4.2. .
Assembly stabilizers
m
GENERATOR UNSTABLE,to avoid damage caused by the overturning of
generator on people or things Claind has planned the assembly of the
stabilizers.
Assembly the feet (D) with the stabilizer brackets (C).
Using screws and washes (B) in dotation to block the stabilizer brackets (C) to
the generator (A).
Eyebolts

Nitrogen Generators Nitro35 Nitro70
11
Use a allen key 4 mm to screw the feet and lift the generator from ground.
e
Claind disclaims any liability for damage to things, animals and people caused by
the overturning of generator caused by a lack of stabilizers.
4.3.
Pneumatic connections
The picture shows the elements that constitute a tipycal Nitrogen generation
plant. The fittings for pneumatic connection of the various components of the
plant (Nitrogen generator, compressed air reservoir, user) are located on the
back of the generator. The external air reservoir must be used only when the
tubes that connect it to the machine exceed 0 m lenght. It is possible to have
a longer line using tubes with nominal diameter > 8mm.
A
B
C
D

Installation
12
e
For an easy installation, we recommend to use flexible polyammide hose. The
generator is supplied along with automatic fittings for polyammide tube 8 x 10
mm. diameter.
.
4.3.1.
Nitrogen outlet
The generator produces Nitrogen at a set purity (between 97% and 99,99%) ac-
cording to the needs of the user in phase of purchase order. The generator is
set in CLAIND facilities at the requested purity and can’t be reset by the user at
a different purity without the intervention of qualified CLAIND technician.
Nitrogen flow rate is depending from the model and from the requested purity.
Outlet pressure depends from the minimum intake compressed air pressure.
You can consider that the maximum pressure of Nitrogen is about 1, bar less
than the intake compressed air pressure.

Nitrogen Generators Nitro35 Nitro70
13
e
During the first start-up, the Nitrogen reservoir will be full of air: the final purity
will be reached only when the total volume of air will be purged with the Nitrogen
fluxed by the generator. The requested time for this operation depends from the
model of the generator, from the requested purity of the Nitrogen as well as
from the volume of the reservoir itself.
CONNECTION
• Locate Nitrogen connection, that is indicated by the script NITROGEN on the
back of the generator;
• take the fitting (1), and mount it;
• connect the line.
e
We recommend to insert an on-off valve on the flow on the outlet line.
4.3.2.
Air inlet
The specification the inlet compressed air are very important for the performan-
ce and for the working life of the Nitrogen generator.
In addition to the minimum requirement of pressure and flow rate (specific of
the model of the generator), compressed air must comply to following specifica-
tion:
(ISO 8 73-1; class 1-4-1):
Dew Point< 3° C
Max. oil content:< 0,01 mg/m
3
Max. particulate concentration (0,1
µ
m diameter)< 0.1 mg/m
3
e
In case of utilization of a poor quality air, permanent damages to the generator
can occur. In this case, Claind won’t be liable for the damages and the costs of
the possible reparation will be charged to the Customer.
e
Puirty of produced Nitrogen decreases as the pressure of the compressd air de-
creases. It is highly recommended to install a reservoir in case that the line isn’t
adequately dimensioned. In case of any need of clarification, please do not he-
sitate to contact CLAIND for other suggestion on the kind of compressed air
plant (compressor, dryer, filters and reservoir) adequate for the specific applica-
tion.
1

Installation
14
CONNECTION
• locate on the rear of the generator the connection of air marked as “AIR”;
• take the fitting (1), and mount it;
• connect the pipe;
• connect the other end of the pipe to the compressed air reservoir (up fitting).
e
we recommend to insert an on-off valve on the outlet line flow.
1

Nitrogen Generators Nitro35 Nitro70
1
4.3.3.
Power supply
c
It is mandatory to apply literally following instructions for your own
safety.
Electric installation must comply to the law, particularly for what concerning the
protection line.
c
arnings for a correct installation:
• Do not use extension cables, adaptors or multiple plugs; when necessary, please
substitute the Schuko plug with another adequate plug.
• Do always connect the protection conductor.
• The power supply plug must be positioned in a easily accessible area.
CONNECTION
• Please find the connection (1) for the power supply cable the on the rear of the
generator.
• Before of connecting the cable, please be sure that the POWER switch is in OFF
position.
• Please connect the power supply cable (2 m lenght, plug IEC320 C13 Schuko)
supplied with the generator.
1

Installation
16
4.4.
arning
e
In case of non admissibility of a lack of gas supply (due to different causes such
as interruption of power supply, intervention of power supply protection, failure
of the generator), even though momentaneus, it would be opportune to forecast
a pneumatic distribution panel that allows the momentaneus and more or less
automatic insert of a spare gas sources.
e
As a precaution, the restart of a generator after the restoration of power supply
isn’t automatic, but manual on command of the operator.
e
When the automatic start of the generator after a black-out is necessary, it is
necessary to set this command in the set-up program
4. .
Packing disposal
It is recommended of keeping the original packing for possible future movimen-
tation, since it guarantees an adequate protection to the generator.

Nitrogen Generators Nitro35 Nitro70
17
.
Disassembly and transport
.1.
Disassembly
• Stop the generator (
par. 6. .
);
• wait for depressurization (about a minute);
• switch off the generator (
par. 6.6.
);
• disconnect the electric power cable;
• close all valves (air inlet, tanks, nitrogen) and detach the pneumatic
connections;
• unscrew the feet using the allen key 4 mm until the generator is free to move;
• unscrew the screws that block the stabilizers to the generator, put this
component in a bag and attached it to the generator.
m
After removal the stabilizers pay attention to the handling of the ge-
nerator, THE GENERATOR IS UNSTABLE.
.2.
Transport
e
Remember that during transport the generator must always remain in a vertical
position.
If conserved, use the original packaging; otherwise use a pallet of adequate di-
mensions to hold the generator, affixing instructions in visible locations, such as:
THIS WAY UP, KEEP IT IN VERTICAL POSITION.
Lift the generator with the eyebolts in dotation.

Use
18
6.
Use
6.1.
Keypad and display
KEYPAD
The user can interact with the generator, giving specific commands, display or
set parameters using the keypad on the front panel of the generator.
The chart below shows the use of the different keys on the keypad:
DISPLAY
The display is composed by two lines of 20 characters each.
The upper line usually shows the functions and parameters, while the lower line
displays the related status and values.
Should the message exceed 20 characters, it is displayed sliding.
Key Fuction
Function It selects a function of the generator
Cursor It increases the selected value
Cursor It decreases the selected value
Operative It starts or stops the generator

Nitrogen Generators Nitro35 Nitro70
19
6.2.
First start-up
6.2.1.
Configuration
The brand new generator is set and ready to start production. The user can ac-
cess to the parameters set up menu (i.e. language, start-up mode, etc. ).
Please see par. “Parameters setting”.
6.2.2.
Working sequence
1. Verify that all connection are made according to what described in chapter 4
(INSTALLATION).
2. Verify compressed air pressure.
3. Shut the Nitrogen line down, at the outlet of the generator.
4. Switch the generator on, switching on the POWER key (see par. 6.3 “Switching
on the generator).
5. Start Nitrogen production pushing the START-STOP key (see par. 6.4. Nitrogen
production).
6. Wait till the generator reaches the stand-by condition. In this condition, the
generator stops the normal production cycle and the display shows the
message STAND-BY.
7. From this moment on, Nitrogen is available in the line, opening the valve
shutted in point 2.
8. Flux in the enviroment for at least 30 minutes in order to clean the pipeline and
the reservoir.
6.3.
Switching on the generator
To switch on the generator, please turn the POWER switch on the front panel
“ON”.
The display lights up and the depressurization cycle starts automatically after
few seconds. In this phase, that last max. 30 seconds, the following message is
displayed:
PLEASE WAIT
DEPRESSURIZATION IN PROGRESS
Once depressurization is completed, the following message appears:
GENERATOR READY
In this status, the generator is ready to accept the production command (see
par. 6.4.) or the switch off command (see par. 6.6.).

Use
20
6.4.
Nitrogen production
When the generator ends the preparation phase (par. 6.3.) and the message
GENERATOR READY
appears on the display, you can start Nitrogen produc-
tion in the following way.
Push the operative button START/STOP.
The productive cycle is started and the following message appears:
PRODUCTION
6. .
Stop the generator
The generator can be stopped any time during production, just by pressing the
START/STOP key.
The following message appears during depressurization, that usually lasts 30-60
seconds:
PLEASE WAIT
DEPRESSURIZATION IN PROGRESS
e
PLEASE NOTE: the START/STOP key is not operative during a block of produc-
tion..
The following message appears at the end of pressurization:
GENERATOR READY
At this time, you have two alternatives:
1. to switch off the generator turning OFF the POWER switch (see par. 6.6.)
2. to start again production pushing the START/STOP key (see par. 6.4.)
6.6.
Switching off the generator
6.6.1.
Correct switch off
The correct switch off of the the generator must be started from the
GENERA-
TOR READY
status. The par. 6. . describes how to reach this condition.
Turn the “POWER” switch OFF to switch off the generator .
6.6.2.
Incorrect switch off
Please avoid of switching off the generator directly without doing the stop ope-
ration described in par. 6. .
This manual suits for next models
1
Other Claind Portable Generator manuals
Popular Portable Generator manuals by other brands

Generac Power Systems
Generac Power Systems 005789-0 owner's manual

Stanley
Stanley GT18 Service manual

Atlas Copco
Atlas Copco QAS 30 Kd instruction manual

BN Products
BN Products BNG5500iE Operation manual

Craftsman
Craftsman CMXGGAS030791 Operator's manual

Extron electronics
Extron electronics VTG 300R brochure

Tektronix
Tektronix VITS 201 instruction manual

Pacific Power Source
Pacific Power Source AFX Series Operation manual

Duracell
Duracell POWER 1000 user manual

MOLEAER
MOLEAER KINGFISHER quick start guide

Generac Power Systems
Generac Power Systems D2.5L G2 Extended Tank Installation guidelines

Shindaiwa
Shindaiwa POWERCENTER 15 Operator's manual