Wagner & Co EURO C22 User manual

Solar Thermal/Solar Collectors EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 1
INSTALLATION INSTRUCTIONS
Figure 1 EURO in-roof installation on pantile roof
●For roof pitch > 20°
●Weather proof integration thanks to aluminium clad-
ding panels and aluminium skirting
●Pipe connections protected under upper cladding
sheets
1) also applies to EURO 22
Content
1 General Safety Notes . . . . . . . . . . . . . 2
1.1 Symbols . . . . . . . . . . . . . . . . . . . 2
1.2 Norms and Regulations . . . . . . . . . . . . 2
1.3 Qualification of the Installer . . . . . . . . . . 2
1.4 Intended Use and Application . . . . . . . . . 2
1.5 Pre Installation Notes . . . . . . . . . . . . . 3
1.6 Recycling Note . . . . . . . . . . . . . . . . 3
2 Setup and Scope of Delivery . . . . . . . . . . 4
2.1 Basic Kit . . . . . . . . . . . . . . . . . . . 4
2.2 Extension Kit . . . . . . . . . . . . . . . . . 5
3 Prepare Installation Field. . . . . . . . . . . . 6
4 Installation . . . . . . . . . . . . . . . . . . 8
EURO C22/L22 In-Roof Mounting System
for Pantile Roofing (after 2010)

2EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142
1 General Safety Notes
1.1 Symbols
The following symbols are used throughout these instruc-
tions and must be adhered to:
DANGER of possibly serious personal injury
WARNING against material damage.
NOTE as additional information
1.2 Norms and Regulations
The standards and regulations applicable at the instal-
lation location must be adhered to. In absence of other
regulations we recommend to follow the following norms:
Thermal Solar Systems and Components
●EN 12976 and EN V 12977
Electrical Work, Potential Equalization, Lightning
Protection
●DIN EN 62305
●VDE 0185 part 305
●DIN VDE 0100 part 540
●VDE 190
●DIN 18382
(Other regulations may apply, depending on your region,
country or territory.)
Especially the pipes in the lower parts of the building
must be connected electrically conductive, conforming to
standards. The collector installation must be profession-
ally integrated with an existing or new lightning protection
system.
Snow and Wind Loads
Comply with local regulations and norms related to snow
and wind loads, within the EU to EN 1991-1-4 (Wind Ac-
tions) and EN 1991-1-3 (Snow Loads). If you have ques-
tions related to structural conditions and planning, please
contact our technical department for information. We offer
comprehensive planning support on a project base.
Work on Roofs
Make sure to observe country and territory regulations re-
lated to roof works and roof sealing standards as well as
professional codes for plumbing work.
The installation process must reflect the on-site condi-
tions as well as applicable rules, regulations and accident
prevention procedures. Installers must be qualified and -
where applicable - licensed to work on roofs.
1.3 Qualification of the Installer
Setup, installation and proper commissioning of the solar
installation must be carried out by authorized profession-
als. Non-compliance renders the warranty void.
1.4 Intended Use and Application
Proper Outdoor Storage of Collectors
Remove protective film, and lay down collectors with glass
pane up.Avoid direct ground contact (e.g. underlay square
timber). Avoid scratches on glass panes by using spacers
between collectors (e.g. wooden laths). When leaning col-
lectors against walls or similar, use a minimum inclination
of 15° and apply spacers. Do not use cardboard as under-
liner. If incorrectly stored, humidity can enter the collec-
tors through the air vents. Storing collectors in plastic film
package can damage the glass surface (see figure 2).
Scope and Limitations of Application
The collector is intended for the application in solar ther-
mal installations for hot water preparation and space heat-
ing support. As operating mediums water (attention – risk
of freezing!) or an appropriate water-glycol mixture can
be used in a closed circuit. Operational conditions under-
running the dew point within the collector for prolonged
periods are not permitted! This can occur for example,
when collectors are integrated in the brine circuit of a heat
pump.
Assure Proper Roofing structure
For in-roof installations the section behind the collectors
hast to be protected against rising moisture and trapped
air. In the area of the collector field sufficient back-side
ventilation of the roof must be assured (see „3. Installa-
tion Field.“)
Overheat Protection
For roof heating centrals and when 4 or more EURO col-
lectors with anti reflective glass are installed vertically, the
“Technical Information Solar Thermal Systems – Setup,
Commissioning and Maintenance” must be followed to
avoid damage to the solar circuit.
Preventing frost Damage
After pressure testing and flushing, collectors cannot be
completely emptied. Make sure that no pure water re-
mains in collector during risk of frost!
Empty Collector on Roof
After being installed on the roof, unfilled collectors should
not be exposed to the sun for more than a few days. Other-
wise thermal stress on gaskets can result in damage. Alter-
natively postpone the installation of gaskets to just before
filling the solar circuit.
Maintenance
For maintenance notes and additional information about
setup and operation of the collector field, please refer to
the technical information “Solar Thermal Systems”.

EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 3
1.5 Pre Installation Notes
●Risk of burns at collector connections as soon as uncov-
ered collector is exposed to the sun (figure 3).
●Danger of open injuries when working with sharp
edged metal sheets and components!
●Remove protective plastic caps from connections be-
fore collector is exposed to the sun. Risk of melting and
damage to absorber!
●Remove glass protection PE-LD film before commenc-
ing installation work! (figure 4).
1.6 Recycling Note
At the end of the long operational lifetime, the valuable
materials of the installation should be recycled in an en-
vironmentally sound manner. If recycling is not possible,
Wagner & Co will take the scrap material back.
Figure 2 Do not expose collector covered with protective film to rain.
Figure 3 Collector connections heat up during solar irradiation.
Figure 4 Remove glass protection film before installing collector!

4EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142
2 Setup and Scope of Delivery
2.1 Basic Kit
Figure 5 Components of basic set
Table 1 Scope of Supply, Basic Set 192 010 64
No. Component Qty. Part No.
1 Flashing sheet, top left 1 819 721 46
2 Flashing sheet, top right 1 819 721 48
3 Wooden support 2 819 920 53
4 Collector connection hose 2 130 26
5 Collector connection hose 1 130 000 10
6 Foam rubber tape 7 819 450 20
7 Cellular rubber tape 2 110 101 23
8 Collector fixing clip 4 190 102 15
9 Side panel left 1 819 721 49
10 Side panel right 1 819 721 50
11 Silicone T-Profile 1 819 450 10
12 Sheet fixing clip 10 181 060 00
13 Flashing sheet, bottom left 1 819 721 54
14 Flashing sheet, bottom right 1 819 721 56
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
17
18
Table 1 cont.
15 Supporting laths 1158 mm 2 819 920 54
16 Supporting laths 200 mm 1 190 102 19
17 Supporting laths for roof tile 2 819 721 57
Gasket ½" (for no. 4 and 5) 6 190 201 52
Solder nipples ½"-18 mm (for no.
4) 2 801 90
Roof felt nails (for no. 12) 12 188 53
Self tapping screws 4 x 35
(for no. 3 u. 8) 12 819 501 86
Self tapping screws 4 x 70
(for no. 15 u. 16) 10 819 500 55
Self tapping screws 5 x 120
(for no. 3) 4 819 501 88
Sheet metal screw with gasket
4,5 x 25 (for no. 1 and 2) 4 819 501 87
Drilling screws 4.2 x 13 with
washer gasket (for no. 13 and14) 4 819 501 85
Silicone gasket material 1 120 100 20

EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 5
2.2 Extension Kit
Figure 6 Components of extension set
Table 2 Scope of Supply, Extension Set 192 010 61
Pos. Component Qty. Part No.
1 Flashing sheet, top 1 819 721 47
2 Wooden support 1 819 920 53
3 Collector connection hose 1 130 000 10
4 Foam rubber tape 2 819 450 20
5 Cellular rubber tape 1 110 101 23
6 Collector fixing clip top 2 190 102 15
7 Silicone T-Profile 1 819 450 10
8 Sheet fixing clips 2 181 060 00
9 Flashing sheet, bottom 1 819 721 55
10 Supporting lath 1158 mm 1 819 920 54
11 Supporting laths for roof tile 1 819 721 57
Solder nipple ½”-18 mm (for no. 3) 2 190 201 50
Roof felt nails (for no. 8) 2 188 53
Self tapping screws 4 x 35
(für Pos. 2 u. 6) 8 819 501 86
Self tapping screws 4 x 70
(for no. 10) 5 819 500 55
Self tapping screws 5 x 120
(for no. 2) 2 819 501 88
Sheet metal screw with gasket
4.5 x 25 (für Pos. 1) 2 819 501 87
Drilling screws 4,2 x 13 with washer
gasket (for no. 9) 2 819 501 85

6EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142
3 Prepare Installation Field
To warrant permanence of the installation, various prereq-
uisites have to be fulfilled:
●A waterproof and diffusion reducing foil with at least 24
mm counter-lathing must be present to assure proper
ventilation. If proper backside ventilation cannot be
provided via ridge and eaves, a venting tile must be in-
stalled, approx. 90 cm above and below the collector
field (see also figure 8, lower part).
●Keep a distance of at least 1m between collectors and
roof components or extensions like vents, turrets, chim-
neys or roof windows that emit humid air. Otherwise ad-
ditional humidity might enter the collector vents at the
collector frame.
●There should be at least 2 rows of roof tiles above and
below the collector field.
●The roof tile row above the collector should extend for
at least 100 mm over the upper flashing sheets. If re-
quired, the roof tiles have to be shortened.
●For best results properly utilize the flexible space below
the collector (distance to lower tile row between 60 and
130 mm).
Figure 7 Dimensions of installation field and positions of installation laths in mm. Choose lath thickness based upon existing laths.
Additionally required laths are coloured grey (5 pieces); lath length = A (width of installation field).
Installation field width = n x collector width + n x 5 mm (distance betw. collectors) + 2 x 15 mm (distance from edge)
Leave the existing roof battens in place as supporting
construction, and affix the additional laths required for the
installation according to the dimensions given in figure 7
and 8.
Ideally determine the width of the collector field in such a
way that on one side the spacing between collectors and
roofing is approx 15 mm. On the other side cut tiles to fit.
Table 3 Dimensions for Installation (mm)
No. of
collectors
Collector field width
Installation field width A
1 collector 1163 1192
2 collectors 2331 2358
3 collectors 3499 3526
4 collectors 4667 4697
A
2231
2424
1890
100
60-130
15

EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 7
Solar sensor Solar sensorSolar sensor
Figure 9 Vertical collector arrangement for two, three and at max. four collectors in serial connection.
Connection of more than four units by combining parallel and serial connection.
Figure 8 In roof installation longitudinal section (upper drawing) and cross section (lower drawing).
1Roof batten, 2Counter lathing, 3Sarking, 4Rafters, 5Low diffusion foil, 6ventilation space
6
1
2
3
4
5
2380-2470
1933
1890
60-130
2231
2424

8EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142
4 Installation
Figure 10 Installation tools: folding rule, drilling machine, Phillips-Bit
PZ2 and 3, open spanner sizes 16, 19, 24, hammer, cutter knife, silicone
gun (where required angle grinder with stone cutter)
Figure 11 Pipe lead with sarking membrane: make a T-shape cut into
the sarking, lead through the connection hose and close cuts with ap-
propriate tape.
Figure 12 1. Afix supporting laths with selft tapping screws 4x70, ends
projecting approx. 100 mm. 2. Insert Collectors (approx. 8 mm distance
between collectors).
Figure 13 Insert silicone T-profile between collectors. Then push col-
lectors together until flush (approx. 5 mm distance between collectors).
Figure 14 Screw on upper collector fixing clip on both collector edges
with 2 self tapping screws 4x35 each.
Figure 15 Apply thin layer of silicone seal between wings of T-profile
and collector frame. Shorten projections of T-Profile to approx 2 cm
on each side.
2
1

EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 9
Figure 16 Connect collectors. Use 2nd wrench to secure connection
and avoid damage. ATTENTION: Danger of burns at connections dur-
ing solar irradiation!
Figure 17 Connect collectors to solar circuit.
Later check for leak tightness!
Figure 18 Slip rubber seal over cable, insert solar sensor into sensor
sleeve; close opening with rubber seal and lead cable through roof.
Figure 19 Position wooden support along collector and fasten with
4x35 and 5x120 self tapping screws.
Figure 20 Insert lower aluminum panels into the deeper rear groove
of the collector frame (see highlighted details). Proceed the same way
with the corner edges.
Figure 21 Affix the lower cladding panels with 2 drilling screws
4.2 x 13 each (with washer gasket) at the positions marked at the col-
lector frame.

10 EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142
Figure 24 Nail on side panels with 4 fixing clips. Figure 25 Affix cellular rubber tape to the upper collector edge
Figure 26 Push upper left flashing sheet into left side panel. The upper
locking bar of the flashing sheet must latch into the outer groove of the
collector frame (see highlighted details).
Figure 27 Stick additional flashing sheets together to connect them.
Figure 23 Push lower panel section downwards, until it snaps into the
latch of the lower corner.
Figure 22 Insert the pushed together side panels into the rear groove
of the frame in such a way that the upper notch (1) snaps into the col-
lector frame. The panel sheet must lay evenly on the battens.
1

EN-XXX_EURO-C22-L22-In-Roof-Pantile_MA-121217-1WA10142 11
Figure 28 Fix upper flashing sheets on the batten using 2 fixing clips. Figure 29 Position the roof-tile supporting bar by vertically shifting it,
so that later the tile row will be aligned with the tiles on the sides. Then
affix with metal strips to roof battens.
Figure 30 Affix black foam rubber tape along the fold to the upper
flashing sheet.
Figure 31 Secure every flashing sheet with 2 additional sheet metal
screws each.
Figure 32 Affix foam rubber tape along the folds of the side panels
as well.
Figure 33 Roof tiles above the collectors may have to be cut to size.
Drill holes into the pieces that have to be attached, and screw to bat-
tens.

Subject to modifications, errors excepted · ©Wagner & Co, 2013 · www.wagner-solar.com
12 WAGNER & CO · Zimmermannstraße 12 · D-35091 Cölbe/Marburg · %+49 (0)64 21 80 07-0 · Fax 80 07-596
Figure 34 Along the side panels, the retaining edge or nose of the
roofing tiles may have to be removed; lateral size reduction may be
required. Use drillings to fix with sccrews or wire, if necessary.
Figure 35 Remove adhesive protection foil from lower aluminum skirt-
ing and press to surface of tiles.
Figure 36 Readily installed EURO in roof installation on pantile roof.
Other manuals for EURO C22
1
This manual suits for next models
1
Table of contents
Popular Rack & Stand manuals by other brands

Hammond Manufacturing
Hammond Manufacturing C4RR Assembly instructions

Konig & Meyer
Konig & Meyer 24100 quick start guide

ATEN
ATEN VE-RMK1U installation guide

Aydin Displays
Aydin Displays CAMBRIDGE CFP47W1 user manual

Crestron
Crestron TS-70 Series quick start

Scanstrut
Scanstrut PTM-R1-S40 installation instructions