T510. Weekly Programming Thermostat with LCD Screen
Weekly circulation, it is possible to set 6 periods called events each day with
different temperatures, also you can select "manual mode" or "temporary
control mode" according to your individual requirements. The thermostat is
recommended for the control of electric heating devices or on/off valve actuator
used in water-based heating systems.
Selection Table:
Technical data:
Voltage : AC230V (AC110V/AC24V available)
Power consumption : 2W
Setting range : 5℃~90℃
Limitation range : 5℃~99℃(factory setting: 35℃)
Switching differential :0.5℃~10℃(factory setting: ±1℃)
Ambient temperature : -5℃~50℃
Protective housing : IP20
Housing material : self-extinguishing PC
Daily use of the thermostat
1)on/off " "
2)In the manual mode,press " " or" "to make temporary control。
3)Press" " or" " to increase or decrease pre-set temperature.
4)Press" " and" "and hold for 5 seconds at the same time to adjust
time. Press " " to choose object to adjust; Press" " or" " to
increase or decrease your set values; Press " " to confirm and exit.
5)Press the " " key to select manual mode or clock-controlled program
mode.
6)It displays the time or the pre-set temperature alternately, and it displays
the measured temperature directly.
7)When you press " " and" "at the same time and hold for 5 seconds,
the thermostat will be locked/unlocked. When it is locked, no operation
can be carried out until it is unlocked.
Display symbols:
Manual mode
Period control mode
Heating
Getting up, the first period
Out in the morning, the second period
Going home at noon, the third period
Out in the afternoon, the forth period
Going home in the evening, the fifth period
Sleeping at night, the sixth period
Period programming
Press " " and hold for 5s to enter the mode of Period programming.