Wasco EXDUL-584E User manual

Handbuch
wasco®
wasco®
user‘s guide
EXDUL-584E
EXDUL-584S
EXDUL-584E
EDV-Nr.: A-371940
EXDUL-584S
EDV-Nr.: A-371920
8 A/D-Eingänge 16 Bit (single-ended) oder
4 A/D-Eingänge 16 Bit (differentiell)
8 D/A-Ausgänge 16 Bit
1 Eingang über Optokoppler
1 Ausgang über Optokoppler
Zähler 32 Bit
LCD-Anzeige (nur EXDUL-584E)
EDP-No: A-371940
8 A/D inputs 16 bit (single ended) or
4 A/D outputs16 bit (differential)
8 D/A outputs16 bit
1 optocoupler isolated digital input
1 optocoupler isolated digital output
counter 32 bit
LCD display (EXDUL-584E only)
EDP-No: 371920

2
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
2
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
Copyright©2018 by Messcomp Datentechnik GmbH
Diese Dokumentation ist urheberrechtlich geschützt. Alle Rechte sind
vorbehalten.
Messcomp Datentechnik GmbH behält sich das Recht vor, die in dieser
DokumentationbeschriebenenProduktejederzeitundohneVorankündigung
zu verändern.
OhneschriftlicheGenehmigungderFirmaMesscompDatentechnikGmbH
darf diese Dokumentation in keinerlei Form vervielfältigt werden.
Geschützte Warenzeichen
Windows®, Visual Basic®, Visual C++®, Visual C#®sind eingetragene
Warenzeichen von Microsoft.
wasco®ist ein eingetragenes Warenzeichen.
EXDUL®ist ein eingetragenes Warenzeichen.
LabVIEW®ist ein eingetragenes Warenzeichen.
Bei anderen genannten Produkt- und Firmennamen kann es sich um
Warenzeichen der jeweiligen Inhaber handeln
Haftungsbeschränkung
Die Firma Messcomp Datentechnik GmbH haftet für keinerlei durch den
GebrauchdesMultifunktionsmodulsEXDUL-584unddieserDokumentation
direkt oder indirekt entstandenen Schäden.
Wichtiger Hinweis:
Dieses Handbuch wurde für die Module EXDUL-584E und EXDUL-584S
erstellt. Das EXDUL-584E bietet zusätzlich eine LCD-Anzeige, alle wei-
terenFunktionenderModulesindidentisch.FürdasEXDUL-584Ssinddie
Befehle und Funktionen, die das Display betreffen, nicht zutreffend.
Copyright©2018 by Messcomp Datentechnik GmbH
This documentation is copyright by Messcomp Datentechnik GmbH. All
rights are reserved.
Messcomp Datentechnik GmbH reserves the right to modify the products
described in this manual at any time and without preannouncement.
No parts of this manual are allowed to be reproduced, copied, translated
or transmitted in any way without prior written consent of Messcomp
Datentechnik GmbH.
Registered Trademarks
Windows®, Visual Basic®, Visual C++®, Visual C#®are registered trade-
marks of Microsoft.
wasco®is registered trademark.
EXDUL®is registered trademark.
LabVIEW®is registered trademark.
Other product and company names mentioned may be trademarks of
their respective owners
Disclaimer
Theinformation inthis manualis intendedto beaccurate andreliable. The
companyMesscompDatentechnikGmbHdoesnotassumeanyliabilityfor
anydamagesarisingoutoftheuseoftheA/DconvertermoduleEXDUL-584
and this documentation, neither for direct nor indirect damages.
Important Information:
ThismanualwasmadeupforthemodulesEXDUL-584EandEXDUL-584S.
EXDUL-584E additionally features an LCD display, all other functions are
identical. For the EXDUL-584S all commands and functions concerning
the LCD display are not applicable.

3
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
3
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
Inhaltsverzeichnis Inhaltsverzeichnis
1. Introduction.......................................................................................5
2. Connection Terminals......................................................................6
2.1 Terminal Assignments of CN1 ...............................................................................6
3. System Components........................................................................7
3.1 Block Diagram EXDUL-584E.................................................................................7
3.2 Block Diagram EXDUL-584S.................................................................................8
3.3 A/D Inputs..............................................................................................................9
3.4 D/A Outputs...........................................................................................................9
3.5 Digital Optocoupler Input.......................................................................................9
3.6 Digital Optocoupler Output....................................................................................9
3.7 Counter..................................................................................................................9
3.8 LCD Display (only EXDUL-584E)..........................................................................9
4. Deployment ....................................................................................10
4.1 Connecting to an Ethernet Port...........................................................................10
4.2 Connecting the Operating Voltage.......................................................................10
4.3 Integrated Webpage of EXDUL-584E / EXDUL-584S.........................................11
4.4 Password Protection - Access Code ...................................................................11
4.5 Default Setting of the Network Conguration ......................................................12
4.6 Composition and Structure of the IPAddress......................................................12
4.7 How to Change the Network Conguration .........................................................13
4.8 Conguration with Static IP Address (DHCP deactivated)...................................14
4.9 Conguration with Dynamic IP Address (DHCP enabled) ...................................16
4.10 LCD Display during the Booting Process (EXDUL-584E only)..........................17
4.11 LCD Display during Operation (EXDUL-584E only) ..........................................18
5. Accessing the EXDUL-584 ............................................................19
5.1 Accessing via the EXDUL Web Page .................................................................19
5.2 Accessing via TCP/IP Sockets ............................................................................20
5.3 How to Identify Hostname, IPAddress and MAC Address..................................21
6. 8 A/D Inputs 16 Bit..........................................................................22
6.1 Single ended Operation.......................................................................................22
6.2 Differential Operation...........................................................................................23
6.3 Combination of Single Ended and Differential Measurement..............................25
6.4 Input Voltage Range............................................................................................25
6.5 Modes of Measurement.......................................................................................27
6.6 Adjustment of the A/D Inputs...............................................................................29

4
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
4
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
7. 8 D/A Outputs 16 Bit.......................................................................30
7.1 Output Voltage Range.........................................................................................30
7.2 Adjustment of the D/A Outputs............................................................................30
8. 1 Optocoupler Input .......................................................................31
8.1 Pin assignment of the input optocoupler .............................................................31
8.2 Input Circuitry ......................................................................................................32
8.3 Input Current........................................................................................................32
9. 1 Optically Isolated Output............................................................33
9.1 Pin assignment of the output optocoupler...........................................................33
9.2 Optocoupler specications ..................................................................................33
9.3 Output circuitry ....................................................................................................33
10. Information, LCD and User Register...........................................34
10.1 Register HW Identication and Serial Number..................................................34
10.2 Memory areas UserA, UserB, UserLCD1m* und UserLCD2m*........................35
10.3 Display Register UserLCD-line1*, UserLCD-line2* and LCD Contrast*...............35
11. Installing the Driver......................................................................36
12. Programming................................................................................37
12.1 Introduction........................................................................................................37
12.2 Modes of Programming.....................................................................................37
12.3 Programming under Windows using the .NET EXDUL.dll Library.....................37
12.4 Programming with TCP-Libraries ......................................................................50
12.5 Access to the Module via LabVIEW and EXDUL.dll..........................................89
13. FAQ - Trouble Shooting ...............................................................90
14. Specications ...............................................................................96
15. Circuitry Examples.......................................................................98
15.1 Wiring of the Optocoupler Input.........................................................................98
15.2 Wiring of the Optocoupler Output......................................................................99
15.3 Wiring of the D/A Outputs................................................................................100
15.4 Wiring of the A/D Inputs single ended ............................................................101
15.5 Wiring of the A/D Inputs differential.................................................................102
16. ASCII Table..................................................................................103
17. Product Liability Act...................................................................106
18. CE Declaration of Conformity ...................................................108

5
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
5
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
1. Produktbeschreibung
DasEXDUL-584EundEXDUL-584Ssindnetzwerkfähige,digitaleI/O-Module
mitEthernet-Interface.JedesModulverfügtüberachtmassebezogeneoder
vierdifferentielle16BitA/D-Eingangskanälemitbipolaren(+/-0,63V,+/-1,27V,
+/-2.55 V, +/-5.1 V, +/-10.2 V) Eingangsspannungsbereichen. Die
Wandlungsauslösung inklusive der damit verbundenen Konguration
der A/D-Komponenten (Bereich-/Kanalauswahl) erfolgt per Software-
Befehl. Die Ausgangsspannungsbereiche der acht 16 Bit D/A-Ausgänge
sind ebenfalls softwaremäßig bipolar (+/-2.55 V, +/-5.1 V, +/-10.2 V)
wählbar. Zusätzlich verfügt das Modul über einen digitalen Eingang und
einen digitalen Ausgang mit galvanischer Trennung über hochwertige
Optokoppler und zusätzlichen Schutzdioden. Spezielle leistungsfähige
Ausgangsoptokoppler bewältigen einen Schaltstrom von bis zu 150 mA.
DerOptokopplereingangkannbeiBedarfalsZählereingangprogrammiert
undgenutztwerden.DieprogrammierbareLCD-AnzeigebeimEXDUL-584E
ermöglicht die Darstellung von I/O-Statusinformation oder programmier-
baren anwenderspezischen Daten.
FürdieVersorgungmitdernotwendigenBetriebsspannungisteinexternes
Netzteilerforderlich.DieAnschlüssefürdieSpannungsversorgungsindwie
dieAnschlüsse der Eingangs- und Ausgangsoptokoppler einer 24poligen
Schraubklemmleistezugeführt.DaskompakteGehäuseerlaubtdenEinsatz
alsmobilesModulamNotebooksowiealsSteuermodulimSteuerungs-und
MaschinenbaumiteinfacherWandmontageoderunkomplizierterMontage
auf DIN EN-Tragschienen.
1. Introduction
The modules EXDUL-584E and EXDUL-584S are network-compatible
digital I/O modules with Ethernet interface. Each module features either
eight ground referenced or four differential 16-bitA/D input channels. You
canadjustseveralbipolarinputvoltageranges(+/-0.63V,+/-1.27V,+/-2.55
V, +/-5.1 V, +/-10.2 V). The conversion process including the associated
conguration of the A/D components (selection of range and channel) is
triggered by software commands. The output voltage ranges (+/-2.55 V,
+/-5.1V, +/-10.2 V) of all of the eight 16-bit D/A outputs are software-se-
lectable as well.
Additionally the module has one digital input and one digital output gal-
vanically opto-isolated by high-quality optocouplers and additional protec-
tion diodes. Special high power output optocouplers cope with a switching
current up to 150 mA. If necessary, the optocoupler input can be pro-
grammed and used as a counter input. The programmable LCD display of
the EXDUL-584E shows either digital I/O status information or program-
mable user-specic data.
An external power supply is required to supply the necessary operating
voltage.Themodulecomeswitha24-pinscrewterminalblockforconnecting
the external power supply as well as the input and output optocouplers.
The compact casing enables the module to be used as a portable device
withanotebook.Formechanicalorcontrolengineeringitcanalsobeeasily
wall mounted or attached to DIN mounting rail.

6
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
6
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
1
3
5
7
9
11
13
15
17
19
21
23
AIN00+
AIN02+
AIN04+
AIN06+
ADGND
AOUT00+
OUT00+
IN00+ / Zähler0
Vcc_EXT
2
4
6
8
10
12
14
16
18
20
22
24
AIN01+
AIN03+
AIN05+
AIN07+
AOUT01+
AOUT07+
DAGND
OUT00-
IN00-
GND_EXT
AOUT03+
AOUT05+
AOUT02+
AOUT04+
AOUT06+
2. Anschlussklemmen
Vcc_EXT:
Anschlussklemme für externe Versorgungsspannung
GND_EXT:
Masse-Anschluss
2.1 Klemmenbelegung von CN1
1
3
5
7
9
11
13
15
17
19
21
23
AIN00+
AIN02+
AIN04+
AIN06+
ADGND
AOUT00+
OUT00+
IN00+ / Zähler0
Vcc_EXT
2
4
6
8
10
12
14
16
18
20
22
24
AIN01+
AIN03+
AIN05+
AIN07+
AOUT01+
AOUT07+
DAGND
OUT00-
IN00-
GND_EXT
AOUT03+
AOUT05+
AOUT02+
AOUT04+
AOUT06+
2. Connection Terminals
2.1 Terminal Assignments of CN1
Vcc_EXT:
Connector for external voltage source
GND_EXT:
Ground connection

7
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
7
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
3.1 Blockschaltbild EXDUL-584E
3. Systemkomponenten
Grak 3.1 Blockschaltbild EXDUL-584E
24polige Schraubklemmleiste
GND
Ethernet Connector
ext. Vcc +10V...+30V
GND
+5V
Optokopplerausgang
OUT00
IN
OUT
Optokopplereingang
IN00
16 Bit A/D-Wandler
AIN00 - AIN07
16 Bit D/A-Wandler
AOUT00 - AOUT07
Display
Zähler
Controller
FIFO
3.1 Block Diagram EXDUL-584E
3. System Components
Fig. 3.1 Block diagram EXDUL-584E
24-pin Screw Terminal Block
GND
Ethernet Connector
ext. Vcc +10V...+30V
GND
+5V
Optocoupler Output
OUT00
IN
OUT
Optocoupler Input
IN00
16 Bit A/D Converter
AIN00 - AIN07
16 Bit D/A Converter
AOUT00 - AOUT07
Display
Counter
Controller
FIFO

8
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
8
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
3.2 Blockschaltbild EXDUL-584S
Grak 3.2 Blockschaltbild EXDUL-584S
24polige Schraubklemmleiste
GND
Controller
Ethernet Connector
ext. Vcc +10V...+30V
GND
+5V
Optokopplerausgang
OUT00
IN
OUT
Optokopplereingang
IN00
16 Bit A/D-Wandler
AIN00 - AIN07
16 Bit D/A-Wandler
AOUT00 - AOUT07
Zähler
FIFO
3.2 Block Diagram EXDUL-584S
Fig. 3.2 Block diagram EXDUL-584S
24-pin Screw Terminal Block
GND
Ethernet Connector
ext. Vcc +10V...+30V
GND
+5V
Optocoupler Output
OUT00
IN
OUT
Optocoupler Input
IN00
16 Bit A/D Converter
AIN00 - AIN07
16 Bit D/A Converter
AOUT00 - AOUT07
Counter
Controller
FIFO

9
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
9
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
3.3 A/D-Eingänge
8 Eingänge single-ended (se) oder 4 Eingänge differentiell (diff) oder kombiniert
se/diff per SW wählbar
Auösung: 16 Bit
Eingangsspannungsbereiche bipolar
+/-0,63 Volt, +/-1,27 Volt, +/-2,55 Volt, +/-5.1 Volt, +/-10.2 Volt
+/-20.4V (nur Differenzeingänge)
FIFO: 10000 Messwerte
Eingangswiderstand: > 500 MΩ
Überspannungsschutz: +/- 50V
max. Abtastrate: 100kS/s
3.4 D/A-Ausgänge
8 Ausgänge
Auösung: 16 Bit
Ausgangsspannungsbereich bipolar: +/-2.55 Volt, +/-5.1 Volt, +/-10.2 Volt
Ausgangsstrom: max +/-5 mA
3.5 Digitaler Eingang über Optokoppler
1 bipolarer Kanal, einzeln galvanisch getrennt
Überspannungsschutz-Dioden
Eingangsspannungsbereich
high = 10..30 Volt
low = 0..3 Volt
3.6 Digitaler Ausgang über Optokoppler
1 Kanal, einzeln galvanisch getrennt
Leistungsoptokoppler
Verpolungsschutz-Dioden
Ausgangsstrom: max. 150 mA
Spannung-CE: max. 50 V
3.7 Zähler
1 programmierbarer Zähler 32 Bit
Zählfrequenz: max. 5 kHz
3.8 LCD Anzeige (nur EXDUL-584E)
Matrixanzeige mit 2 Zeilen und 16 Spalten zur Darstellung von 16 Zeichen je
Zeile
Programmierbar zur Darstellung anwendungsspezischer Daten oder als I/O-
Zustandsanzeige
3.3 A/D Inputs
8inputssingle-ended(se)or4inputsdifferential(diff)orcombinedse/diffsoftware-
selectable
Resolution: 16 bit
Input voltage ranges bipolar: +/-0.63 V, +/-1.27 V, +/-2.55 V, +/-5.1 V, +/-10.2 V
+/-20.4V (differential inputs only)
FIFO: 10000 measuring values
Input resistance: > 500 MΩ
Over voltage protection: +/- 50V
maximum sampling rate: 100kSps
3.4 D/A Outputs
8 outputs
Resolution: 16 bit
Output voltage ranges bipolar: +/-2.55 Volt, +/-5.1 Volt, +/-10.2 Volt
Output current: max +/-5 mA
3.5 Digital Optocoupler Input
1 bipolar channel, galvanically isolated
Over voltage protection diodes
Input voltage range
high = 10..30 Volt
low = 0..3 Volt
3.6 Digital Optocoupler Output
1 channel, galvanically isolated
High capacity optocoupler
Reverse polarity protection
Output current: max. 150 mA
Switching voltage: max. 50 V
3.7 Counter
1 programmable counter 32 bit
Counting frequency: max. 5 kHz
3.8 LCD Display (only EXDUL-584E)
Matrix display with 2 lines and 16 columns displaying 16 characters each line
Programmable to display user specic data or I/O state

10
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
10
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
4. Inbetriebnahme
Der Netzwerk- bzw. PC-Anschluss erfolgt einfach und unkompliziert über
eine Ethernet-Schnittstelle, die Konguration über einen Webbrowser. Für
die Versorgung mit der notwendigen Betriebsspannung ist ein externes
Netzteil notwendig.
4.1 Anschluss an einen Ethernet-Port
Das EXDUL-584E/EXDUL-584S verfügt über ein 10Base-T Ethernet
Interface mit RJ45 Anschluss (8P8C-Modularbuchse) und wird über ein
Netzwerkkabel direkt an einen PC, einen Ethernet-Hub oder an einen
Ethernet-Switch angeschlossen.
DasModulbootetnachAnlegenderBetriebsspannung,sobaldeinestabile
Ethernet-Verbindung besteht, leuchtet die linke LED an der RJ45-Buchse
des EXDUL-584 kontinuierlich grün.
1
8
4.2 Anschluss der Betriebsspannung
Das EXDUL-584E / EXDUL-584S benötigt für den Betrieb eine
Spannungsversorgung von +10 V ... +30 V DC an Klemme 23 (Vcc) und
Klemme 24 (GND).
4. Deployment
Connection to a network or to a computer is made in an easy and con-
venient way via an Ethernet interface, the conguration is made via any
web browser. An external power supply unit is required for the necessary
operating voltage.
4.1 Connecting to an Ethernet Port
The module EXDUL-584E / EXDUL-584S features a 10Base-T Ethernet
interface with RJ45 connection (8P8C modular connector) and you can
connect directly to a PC, Ethernet hub or Ethernet switch using a network
cable.
Aftertheoperatingvoltageisappliedthemodulewillbootup.Onceastable
connection is established, the green LED on the left side of the RJ45 jack
is lit continuously.
1
8
4.2 Connecting the Operating Voltage
TheEXDUL-584E/EXDUL-584Srequiresapowersupplyof+10V...+30V
across terminal 23 (Vcc) and terminal 24 (GND).

11
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
11
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
4.3 Integrierte Webpage des EXDUL-584E / EXDUL-584S
Der Zugriff auf die Webpage des EXDUL-584 ist über eine TCP/
IP-Verbindung durch einen beliebigen Web-/Internetbrowser wie Mozilla
Firefox, Internet Explorer, Safari usw. möglich. Über die Webpage besteht
die Möglichkeit, Verbindungsinformationen auszulesen und passwortge-
schützt Kongurationsdaten zu verändern. Vorgenommene Einstellungen
werdeniminternenEEPROMdesEXDUL-584gespeichertundbeimBooten
geladen. Die EXDUL-584-Webpage ermöglicht zudem das Beschreiben,
Auslesen und Anzeigen der Anwender-Speicherbereiche UserA, UserB,
UserLCD1mundUserLCD2msowiedasStartenundStoppendesZählers
oder das Testen der digitalen Ein- und Ausgänge.
4.4 Passwortschutz - Zugangskennung
Wie bereits erwähnt, ist über die EXDUL-Webpage die Netzwerk-
Konguration, die Einstellung der LCD-Anzeige, das Beschreiben der
User-Speicherbereiche sowie das Setzen der Ein- und Ausgänge und
des Zählers möglich. Um unbefugten Zugriff zu vermeiden, sind diese
Einstellungsbereiche durch ein Passwort geschützt.
Werksmäßig ist folgende Zugangskennung voreingestellt:
Benutzerkennung: admin
Kennwort: 11111111
Groß-/Kleinschreibung beachten!
FallsüberdieseZugangsdatenkeinZugriffmöglichist,wurdedieEinstellung
der Zugangskennung von Ihrem Systemadministrator geändert.
4.3 Integrated Webpage of EXDUL-584E / EXDUL-584S
Any web or internet browser such as Mozilla Firefox, Internet Explorer,
Safari etc. can access to the web page of EXDUL-584 via a TCP/IP con-
nection. The web page enables to read out connection information and to
modify conguration data under password protection. The settings made
are stored in the internal EEPROM of EXDUL-584 and are loaded during
the booting process. The EXDUL-584 web page enables you to write,
read-out and to display the user memory areas UserA, UserB, UserLCD1
and UserLCD2 as well as to start and to stop the counter or to monitor the
digital inputs and outputs.
4.4 Password Protection - Access Code
As mentioned before, using the EXDUL web page enables to congure
the network, to set up the LCD display, to write into user specic memory
areas as well as to set up the inputs and outputs or the counter. To prevent
unauthorised access, these setting sections are password protected.
Following default access code is preset:
User name: admin
Password: 11111111
Please observe upper and lower case!
If you don’t succeed in accessing with this access code, your system
administrator changed the settings of the access code.

12
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
12
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
4.5 Grundeinstellung Netzwerk-Konguration
In der Grundeinstellung ist das EXDUL-584 auf DHCP (Dynamic Host
Conguration Protocol), d.h. auf dynamische IP-Adresse eingestellt. Bei
derInbetriebnahme schickt das EXDUL-584 eine Nachfrage ins Netzwerk
(LAN). In einem Netzwerk mit aktiven DHCP-Dienst wird dem Modul
daraufhin automatisch eine IP-Adresse zugewiesen. Diese Einstellung
ermöglicht Ihnen einfach und unkompliziert den Anschluss des Moduls
zum Anpassen der Kongurationsdaten nach Ihren Bedürfnissen.
4.6 Zusammensetzung und Aufbau der IP-Adresse
IP4-Adressenbestehen aus 32Bits =4 Bytes (Oktetten).Jedes Byte kann
einenWertzwischen0 und255annehmen. DieDarstellung erfolgt alsvier
Dezimalzahlen durch Punkte getrennt (z.B. 192.168.1.83).
Jede IP-Adresse enthält einen Netzwerk- und Geräteanteil (Hostanteil).
ÜberdieSubnetzmaskeerfolgt dieTrennungzwischenNetz- und Hostteil.
Alle Geräte, die sich im gleichen Netzwerk benden, können miteinander
kommunizieren.
Beispiel:
IstderIP-Adresse192.168.1.83dieSubnetzmaske255.255.0.0zugeordnet,
so bendet sich das Gerät im Netz 192.168.-.- als Gerät -.-.1.83.
4.5 Default Setting of the Network Conguration
In the factory setting the EXDUL-584 is set to DHCP (Dynamic Host
Conguration Protocol), i.e. to dynamic IP address. During initialization, the
EXDUL-584 sends a request to the network (LAN). A network with active
DHCP service will then automatically assign an IPaddress to the module.
This setting allows an easy and convenient connection of the module and
to adjust custom-t conguration data.
4.6 Composition and Structure of the IP Address
IPv4 addresses consist of 32 Bits = 4 Bytes (octets). Each Byte can range
from 0 to 255. It is shown as four decimal numbers separated by dots (e.g.
192.168.1.83).
Each IP address consists of a network and a host part (host identier). A
subnet mask divides network part and host part.All devices located in the
same network can communicate with each other.
Example:
If subnet mask 255.255.0.0 is allocated to the IP address 192.168.1.83,
then the device is located in the network 192.168.-.- as device -.-.1.83.

13
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
13
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
4.7 Änderung der Netzwerk-Konguration
Zum Ändern der werksmäßigen Kongurationseinstellungen schließen
Sie das EXDUL-584 über das beiliegende Standard-Netzwerkkabel an
ein lokales Netzwerk und die Spannungsversorgung (+10 V ...+30 V) an
Klemme 23 (Vcc) und Klemme 24 (GND) des Moduls an. Das EXDUL
bootet jetzt, die linke LED an der RJ45-Buchse des EXDUL-584 leuchtet
kontinuierlich grün, sobald eine stabile Ethernet-Verbindung besteht.
Über einen beliebigen Web-/Internetbrowser ist durch Eingabe des Host-
Namens http://EXDUL-584 der Zugriff auf die EXDUL-584-Webpage
möglich. Durch Anklicken des Buttons TCP/IP Cong öffnet folgende
Kongurationsmaske:
Über das beiliegende Standard-Netzwerkkabel kann das EXDUL-584
auchdirektaneinenPCmitEthernet-Schnittstelleangeschlossenwerden.
BeimDirektanschlußstehtimNormalfallkeinDHCP-DienstzurVerfügung,
da weder der PC noch das EXDUL diesen bietet. Für diesen Fall ist das
EXDUL-584überdiezuletzteingestelltestatischeIP-Adresseansprechbar.
Für EXDUL-Neugeräte ist die IP-Adresse 169.254.1.1 gültig.
4.7 How to Change the Network Conguration
To change the factory default conguration settings, connect the EXDUL-584
to a local network using the enclosed standard network cable and connect
the power supply (+10 V ...+30 V) across terminal 23 (Vcc) and terminal
24 (GND) of the module.The EXDULboots up immediately. Once a stable
Ethernet connection is established, the green LED on the left side of the
RJ45 jack is lit green continuously. Access to the EXDUl-584 web page
is possible using any web or internet browser by prompting the hostname
http://EXDUL-584. Click the TCP/IP Cong button to open the following
conguration screen:
You can use the enclosed standard network cable to connect EXDUL-584
alsodirectlytoahostPCwithanEthernetinterface.Ifyouconnectdirectly,
normally no DHCP service is available, for neither the PC nor the EXDUL
provides one. In this case, the last set static IP address can be used for
addressing the EXDUL-584. The IPaddress 169.254.1.1 is applicable for
factory-new EXDUL devices.

14
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
14
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
Wichtiger Hinweis:
Zum Kommunizieren mit dem angeschlossenen EXDUL muss sich der
verwendete PC im gleichen Netzwerk benden. Dazu muss beim Rechner
DHCP deaktiviert und z.B.von der EXDUL-IP-Adresse 192.168.1.83
(Subnetzmaske 255.255.0.0) die ersten zwei Zahlenblöcke (192.168) in
die IP-Adresse des Rechners übernommen werden. Die zwei weiteren
Blöcke können, jeweils Ihren Bedürfnissen angepasst, mit Werten zwi-
schen 0 und 255 belegt werden.
DerNetzanteilderIP-AdresseistvonderSubnetzmaskeabhängig.Vonder
IP-AdressedesEXDUL-584müssenalleOktette,dieinderSubnetzmaske
mit255 belegtsind, in dieIP-Adresse desRechners übernommen werden
(siehe auch Kapitel 4.6 Zusammensetzung und Aufbau der IP-Adresse).
4.8 Konguration mit statischer IP-Adresse (DHCP deaktiviert)
Für die Konguration des EXDUL-584 auf die statische IP-Adresse muss
DHCP in der EXDUL-584-Kongurationsmaske deaktiviert werden. Für die
Kongurationsänderung schließen Sie das EXDUL-584 wie unter Kapitel 4.7
(Änderung der Netzwerk-Konguration) an ein LAN oder einen PC an.
Important Information:
The PC used and the connected EXDUL are to be located in the same
network to be able to communicate. For this purpose, DHCP has to be
deactivated on the computer and the rst two number blocks (192.168)
of EXDUL IP address 192.168.1.83 (Subnet mask 255.255.0.0) are to
be transferred to the computer‘s IP address. The next two number blocks
can be assigned with values between 0 and 255 adjusted to your current
requirements.
Thenetwork part oftheIPaddressdepends on thesubnet mask. Fromthe
IP address of the Exdul-584 all octets that are assigned 255 in the subnet
mask are to be transferred to the computer‘s IP address (see chapter 4.6
Composition and structure of IP address)
4.8 Conguration with Static IP Address (DHCP deactivated)
To congure EXDUL-584 to the static IP address, DHCP has to be deacti-
vated in the EXDUL-584 conguration screen. To change the conguration,
connect the EXDUL-584 to a LAN or PC as per description in chapter 4.7
(How to change the network conguration).

15
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
15
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
Sobald eine stabile Ethernet-Verbindung besteht, haben Sie über einen
beliebigen Internetbrowser Zugriff auf die Webpage des EXDUL-584.
DurchEingabedesHost-Namenshttp://EXDUL-584solltederBrowserdie
EXDUL-584-Webpage öffnen, das Anklicken des Buttons TCP/IP Cong
öffnet folgende Kongurationsmaske:
Sobald Sie DHCP deaktivieren, können Sie Ihre gewünschte IP-Adresse,
Subnetzmaske und den gewünschten Host-Namen eintragen. Durch
Anklicken des Buttons Konguration speichern werden die aktuell einge-
tragenen Daten in den internen Speicher des EXDUL-584 übernommen.
DasModulistabdiesenZeitpunktnurüberdiehiereingestellteIP-Adresse
bzw. über den angegebenen Host-Namen ansprechbar. Der verwendete
PC oder das LAN muss sich dazu im gleichen Netz benden.
WichtigerHinweis:JedeIP-AdresseundjederHost-Namedarfnureinem
Gerätbzw.ModulineinemNetzwerkzugeteiltwerden,eineDoppelvergabe
ist nicht zulässig! Der Host-Name darf beliebig gewählt werden, jedoch
nurausdenASCI-Zeichen0-9sowieA-Z(Groß/Kleinschreibungegal)und
dem-(Bindestrich)bestehen.Bestimmte IP-Adressensindreserviertbzw.
haben eine Sonderfunktion wie z.B.: 127.0.0.1 (local Host)
192.168.1.0 (0 ist Adresse des Netzes) mit 255.255.255.0 (Subnetz-
maske)
Once a stable Ethernet connection is established, you can access the
EXDUL-584 web page via any Internet browser. Upon prompting the
hostname http://EXDUL-584, the browser should open the EXDUL-584
web page. Click the button TCP/IP Cong to open following conguration
screen:
Once you disable DHCP, you can enter your desired IP address, subnet
mask, and the desired hostname. By clicking the button Konguration
speichern, the currently entered data will be transferred to the internal
memory of the EXDUL-584. From this point on, the module only can be
addressed via the IP address set here, or via the indicated hostname,
respectively. The used PC or LAN must be located in the same network.
Important note: Eachdevice or modulein anetwork must haveits unique
IP address or hostname, second assignment is not permitted! The host-
name may be chosen arbitrarily, but may contain only the ASCII digits 0
through 9 and the letters A through Z (leave out upper and lower case)
and - (hyphen-minus).
Some IP addresses are reserved or have special functions such as:
127.0.0.1 (local host).
192.168.1.0 (0 is the network address) with 255.255.255.0 (subnet
mask).

16
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
16
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
Bitte erkundigen Sie sich bei Ihrem Netzwerkadministrator, welche
IP-Adresse Sie verwenden dürfen. Bei Verwendung unzulässiger
IP-Adressen besteht die Möglichkeit, dass der Zugriff auf das Modul nicht
mehrmöglichist.DieEinstellungderwichtigstennichtzulässigenAdressen
wird vom Modul blockiert.
4.9 Konguration mit dynamischer IP-Adresse (DHCP aktiviert)
FallsSiedas EXDUL-584 ineinbestehendes Netzwerk mitbereitsaktiven
DHCP-Server einbinden und über eine dynamische IP-Adresse anspre-
chen möchten, muss DHCP (Dynamic Host Conguration Protocol) in
der Kongurationsmaske der Webpage aktiviert sein. In der werksmä-
ßigen Grundeinstellung ist DHCP bereits aktiviert und keine Umstellung
notwendig.
Bei eingestellter statischer IP-Adresse wird DHCP wie folgt aktiviert:
Schließen Sie dazu das EXDUL-584 über ein Netzwerkkabel (bei älteren
PCsübereinCrossover-Netzwerkkabel)aneinenComputeran.Derverwen-
dete PC muss auf „Folgende IP-Adresse verwenden: (DHCP-deaktiviert)“
eingestelltsein.IndieIP-AdressedesRechnersmussderNetzanteil(siehe
dazu Kapitel 4.6, Zusammensetzung undAufbau der IP-Adresse) aus der
IP-AdressedesEXDUL-584übernommenwerden,dennderComputerund
das EXDUL müssen sich im gleichen Netzwerk benden. An den Klemmen
23 (Vcc) und 24 (GND) schließen Sie die Spannungsversorgung (+10 V
...+30 V) für das EXDUL-584 an. Das Modul bootet jetzt, die linke LED
an der RJ45-Buchse des EXDUL-584 leuchtet kontinuierlich grün, sobald
eine stabile Ethernet-Verbindung besteht. Den Zugriff auf die Webpage
des EXDUL-584 ermöglicht Ihnen ein beliebiger Internetbrowser durch
Eingabe des Host-Namens oder der IP-Adresse des EXDUL-584. Jetzt
sollte der Browser die EXDUL-584-Webpage öffnen. DurchAnklicken des
Buttons TCP/IP Cong öffnet sich die Kongurationsmaske, in der Sie wie
in nachfolgender Abbildung Enable DHCP aktivieren:
Please consult your network administrator which IP address you may use.
If you use an invalid IP address the access to the module may then be
impossible. The setting of the most important impermissible addresses is
blocked by the module.
4.9 Conguration with Dynamic IP Address (DHCP enabled)
If you want to implement the EXDUL-584 into an existing network with
an already active DHCP server and to map it via a dynamic IP address,
DHCP (Dynamic Host Conguration Protocol) has to be activated in the
conguration screen of the web page. In factory default setting, DHCP is
already activated and there is no need to change.
If the IP address is set statically, activate DHCP as follows:
ConnecttheEXDUL-584toacomputerusinganetworkcable(oldercompu-
tersmayneedacrossovernetworkcable).Pleasemakesurethatthecom-
puter is set to: Folgende IP-Adresse verwenden: (DHCP deaktiviert)
The network part of the IP address (see chapter 4.6 Composition and
structure of IP address) has to be transferred from the IP address of the
EXDUL-584, because the computer and the EXDUL are to be located in
the same network.
Connect the power supply (+10 V ...+30V) across terminals 23 (Vcc) and
24 (GND) of the module. The EXDUL will boot up immediately. Once a
stable connection is established, the LED on the left side of the RJ45 jack
is lit green continuously.
Accessto the EXDUl-584webpage is possibleusing any internetbrowser
entering the hostname or IP address of the EXDUL-584.The browser now
should open the EXDUL web page. Clicking the TCP/IP Cong button
opens the conguration screen and you can acitivate DHCP by setting the
checkmark Enable DHCP as shown in the following gure:

17
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
17
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
Wichtiger Hinweis:
Bevor Sie DHCP aktivieren, ist eineAbsprache mit Ihrem Netzwerkadmi-
nistrator dringend notwendig. Sollten Sie mehrere gleiche Module aus
der EXDUL-5xx-Serie in ein Netzwerk einbinden, müssen Sie den vorein-
gestellten Host-Namen der einzelnen Module ändern. Jeder Host-Name
darf innerhalb eines Netzwerkes nur einem Gerät bzw. Modul zugewiesen
werden. Der Host-Name kann beliebig gewählt werden, jedoch nur aus
den ASCI-Zeichen 0-9 sowie A-Z (Groß/Kleinschreibung egal) und dem -
(Bindestrich) bestehen.
4.10 LCD-Anzeige während des Bootvorgangs (nur EXDUL-584E)
Während des Bootvorgangs des Moduls erscheint im Display eine
Infoanzeige. In Zeile 1 wird der Modul-Name angezeigt, in Zeile 2 die
Information, dass das Modul initialisiert wird. Sobald der Bootvorgang
abgeschlossen ist, erscheint in beiden Fällen, je nach Einstellung, ent-
weder die I/O-Statusanzeige oder die UserLCD-Anzeige.
Important note:
Westronglyrecommendtoconsult your networkadministratorbefore acti-
vating DHCP. If you want to embed several identical modules of the series
EXDUL-5xx into one network, the presetted hostname of each module
has to be changed. Each hostname within a network must be assigned to
only one device or module. The hostname can be chosen arbitrarily, but
may contain only the ASCII digits 0 through 9 and the letters A through Z
(leave out upper and lower case) and - (hyphen-minus).
4.10 LCD Display during the Booting Process (EXDUL-584E only)
During booting-up the module, the display shows information data. Line 1
indicatesthe module name,line2 displays theinformation that themodule
is being initialized.After having completed the boot process, in both cases
the display shows either I/O status information or UserLCD information
depending on your conguration.

18
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
18
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
4.11 LCD-Anzeige während des Betriebs (nur EXDUL-584E)
Nach dem Booten schaltet das Display, je nach Einstellung, von der
Infoanzeige in die I/O-Statusanzeige oder UserLCD-Anzeige. Während
der I/O-Statusanzeige werden in Zeile1 die aktuellen Zustände der
Eingänge, in Zeile 2 die Zustände der Ausgänge angezeigt. Falls in
der EXDUL-584 Webpage der UserLCD-Modus aktiviert ist, erscheint
anstelle der I/O-Statusanzeige die UserLCD-Anzeige mit den Werten aus
den Speicherbereichen UserLCD1m und UserLCD2m. Die Daten aus
UserLCD1mundUserLCD2mwerdensolangeaufdemLCD-Displayange-
zeigt, bis neue Benutzerdaten über UserLCD-Zeile1 und UserLCD-Zeile2
auf die LCD-Anzeige geschrieben werden. Um einen „Screen-Burn“ zu
vermeiden, wechselt die Anzeige im laufenden Betrieb etwa jede Minute
für ca. fünf Sekunden von der I/O-Statusanzeige oder UserLCD-Anzeige
in die Infoanzeige mit der aktuellen IP-Adresse.
4.11 LCD Display during Operation (EXDUL-584E only)
After having completed the boot process, the display switches from infor-
mation display to I/O status display or UserLCD display depending on the
setting. If the I/O status is displayed, line 1 indicates the current states of
the inputs, line 2 the states of the outputs. If the UserLCD mode is acti-
vated in the EXDUL-584 web page, the display shows UserLCD data with
the values from the memory areas UserLCD1m and UserLCD2m instead
of I/O status display.
You can see the values of UserLCD1m and UserLCD2m on the LCD
display unless you write new user data in UserLCD line1 and line2 of the
LCD display. In order to avoid „screen-burn“ during operation, the display
alternatesfromI/OstatusdisplayorUserLCDdisplaytoinformationdisplay
with the current IP address for approx. 5 seconds every minute.

19
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
19
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
5. Zugriff auf das EXDUL-584
Der Zugriff auf die Kongurationseinstellungen und auf die Ein-/Ausgänge
des EXDUL-584 ist wie bereits erwähnt über die EXDUL-584 Webpage
sowie über TCP/IP-Sockets möglich. Dazu wird die IP-Adresse, der Host-
Name oder die MAC-Adresse benötigt.
5.1 Zugriff über die EXDUL Webpage
Die Webpage des EXDUL-584 ermöglicht die Eingänge zu lesen, die
Ausgänge zu setzen, dieAnwender-Speicherbereiche UserA, UserB und
UserLCD sowie die Verbindungs- oder Modulinformationen auszulesen
und die Kongurationsdaten zu verändern. Der Zugriff auf die Webpage
ist von jedem mit dem Modul verbundenen Computer über einen belie-
bigen Internetbrowser möglich. Der verwendete PC muss auf IP-Adresse
automatischbeziehen(DHCP-aktiviert)eingestelltsein,soweitsichdas
EXDUL-584 noch im Auslieferungszustand (DHCP aktiviert) bendet und
in ein Netzwerk mit aktiven DHCP-Dienst integriert ist. Durch Eingabe des
Host-Namens(ImAuslieferzustandhttp://EXDUL-584,ansonstendenvon
Ihnen eingestellten Host-Namen, evtl. über ExdulUtility_v2_xx oder höher
feststellen) können Sie die Webpage öffnen. Falls ein Öffnen der EXDUL-
584-Webpage nicht möglich ist, überprüfen Sie die Netzwerkverbindung
oder den eingegebenen Host-Namen. Nähere Informationen im Kapitel
FAQ - Problembehandlung.
5. Accessing the EXDUL-584
As mentioned before, access to the conguration set-up and to the inputs
and outputs of the EXDUL-584 is possible via EXDUL-584 web page or
via TCP/IP sockets. For this you need to know IP address, hostname or
MAC address.
5.1 Accessing via the EXDUL Web Page
The web page of the EXDUL-584 allows to read inputs, set outputs, read
out memory areas UserA, UserB and UserLCD as well as to read out con-
nection or module information or to change conguration data. You can
access to the web page via any internet browser from any computer con-
nected to the module. The computer used has to be set to „IP-Adresse
automatisch beziehen (DHCP-aktiviert)“ as long as the module still is
in its delivery state (DHCP enabled) and if it is integrated in a network
with active DHCP service. Entering the hostname (in default state http://
EXDUL-584, otherwise the name you chosed, or you might determine it
via ExdulUtility_v2_xx or later) you can open the web page. If you don‘t
succeed in opening the EXDUL-584 web page, please check the network
connections or the entered hostname. For more details see chapter FAQ
- trouble shooting.

20
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH DV06
20
EXDUL-584E / EXDUL-584S© 2018 by Messcomp Datentechnik GmbH EV06
wasco®wasco®
5.2 Zugriff über TCP/IP-Sockets
MitderVerwendungdesTCP-ProtokollswirdeinezuverlässigeVerbindung
zwischen PC und dem EXDUL-584 erreicht. Das Protokoll ergreift selb-
ständig Maßnahmen bei Datenverlust. Die Adressierung des Moduls ndet
übereine4ByteIP-Adresse(IPV4)bzw.überdenvergebenenHost-Namen
undeinerPortnummer9760statt.DerPCversendetüberdieVerbindungfür
jedenBefehl einByte-Array. DasModul verarbeitet den Befehl und sendet
immereineRückantwort.InKombinationmiteinerHochspracheistüberdie
TCP/IP-Verbindung das Lesen der Eingänge, das Setzen der Ausgänge,
dasStarten,StoppenundAuslesendesZählers,dasBeschreibenderUser-
Speicherbereiche,dasAuslesenderVerbindungs-undModulinformationen
sowie das Verändern der Kongurationsdaten möglich.
5.2 Accessing via TCP/IP Sockets
Using the TCP protocol, a reliable connection between the computer and
theEXDUL-584 willbe achieved. The protocolautomatically takesactions
in case of data loss. The module is mapped via a 4 Byte IPaddress (IPv4)
or via the assigned hostname respectively and a port number 9760. The
computertransmitsone byte arrayforevery command viathisconnection.
The module processes the command and always sends a response. In
combination with a high-level language, the TCP/IP connection allows to
read the inputs, set the outputs, start, stop and to read out the counter, to
write user specic memory areas, to read out the connection or module
information and to change conguration settings as well.
This manual suits for next models
3
Table of contents
Other Wasco I/O System manuals