PROGRAMMING
Power up LED display sequence:
1 - Range (Default 30 PSI / 10/ 60)
2 - Over Boost Warning Limit (Default 18 PSI/ Range 1-60 PSI)
3 - PSI or 4 - BAR selection (1 PSI / 0 BAR)
You can cycle the menu from 1 to 4 by pressing and depressing the button.
Select the menu item you want to modify by pressing the button.
1 –Set the RANGE (cycles 10, 30, 60) by pressing the button
2 –Set Over Boost Warning Limit (cycles from 1 to 60) by pressing the button
3 –Set for PSI mode
4 –Set for BAR mode
When the Over Boost Warning Limit is reached all RED LEDs will flash
CALIBRATION
Turn it on while you hold the switch at the back and release afterwards.
WIRING
WB B2 has a 4ft output cable (4 cables / green-white-red-black).
Red power cable goes to a switched 12V source which comes
ON when the ignition is ON. Please use a minimum 2A fuse with
the connection. Only 50 mA is used on power.
Black cable goes to a grounded source such as battery ground
post.
Green digital output is 9600 8N1 serial that can be connected
to your PC.
If you want to connect other devices such as EMS and data
loggers, you can use white analog cable for 0-5V output. Lower
and upper limits are 0 PSIa and 80 PSIa (0V = 0 PSIa, 5V = 80
PSIa)
The cable and the vacuum hose (8ft) should be routed in a way
so that there would not be any contact extreme heat sources to
prevent damage.