Mounting:
Selectthe mounting locationand cut a rough opening 118" wider than the box to
allow the Distributionpanel to slide in easily. The hole shouldbe framed so that
the
box
can
be secured tightly.
TheOEM may wish to pre-wire the box for easeof installation. Selectthe
numberof lcnockouts to be used and removethem. Two sizeshave been
provided.The 1118" isfor the 30 amppower cord. The 718" hales
are
for the
romexon the l2OVAC side and the wires on the 12VDCside. Remember to select
the proper gauge wire for the load and distance. Leave the rest of
the
knock-
@
outs in place. Be sure to use appropriateRomex connectorsand strain reliefs to
securethe wiresto the box. (see wiring diagram)
GeneralInformation:
AC Bus Bar Max. Rating is
33.4
Amps
Quick connects:
Thenonmetalicsheathconnector is foruse with wire rangesof 10-2
thru
14-2 only.
1.For use with cu wiring only.
2.Use
K.S.
TerminalsInc. Model FDD2-250 femalequick connectonly
3.
Use
Id
#34 (blue) as the crimpingtool
4. The end-use manufactureris to provide strainrelief
and
instructionson how to use it
5.
The striplength is 6.5
mm
For Field WigAluminumTerminals TheTighteningTorque Max. 40 in-lb.
TemperatureRating is 90QC.
Fusesand breakers:
Breakers
1.
The 30 Amp ULTUDistributionpanel was designed for a 30
AMP
main
haker
with branch circuits. Doublebreakers may be
used
forthe branch circuits. Should
a breaker become faulty replace with the same type breaker asprovided by the
OEM.
2.
AC Breaker Information:
AC Breaker Specification:MAX.30Amps 120Vl240V 1pole or poles.
CurrentInterruptingRating
MAX.RMS
SYM.Arnperes 10,000AT 1201240
VOLTS AC
3.
ACBreaker Manufacture:
1:"Cutler-Hammer": Type BRD &A
2:"SIEMENS": Type QP OR QT
12
VDC Fuw
Each circuit in the WFCO
ULTRA
Distributionpanel was designed for a maximum
of a 20 amp Little Type 257 automotivestylehe.Should one need to be
replacedbe sure to replace it
with
the sametype and amp rating as originally
suppliedby the OEM. Replacing it with either a higher or lower amp fuse could
result
in
the panel not functioningproperly.
Fuse Diagram:
Max. Main Circuit Fuse Size: 30
AMP
Max. BranchCircuit Breaker Fuse Size:20
AMP
12
VDC
Fuse use Only Littelfuse. Type 257Fuse. Max. 20
AMP
Each 12VDCcircuit of the WFCO
ULTRA
Distributionpanel is provided
~4th
a LED
indicatorlight. Shouldthe fbse"blownor an open be
caused
the LEDwill lightup
indicatingwhich circuit is open and which fuse needs to
be
replaced.