The microwave hood is set for ventless (recirculating)
instaliation. Forwali or roof venting changesto the venting
system must be made.
CAUTtON: To reduce risk of fire and to
properly exhaust air, be sure to vent air
outside. Do not vent exhaust air into
spaces within walls or ceilings or into
attics, craw_ spaces or garages.
Forwail or roof venting methods:
Choosebetween roof venting or wall venting.
If the waii exhaust method is chosen, be surethat there is
proper clearancewithin the wall for the exhaustvent.
Vent materialsneededfor installation are not included.
We recommend:
,/using waft and roof capsthat haveback-draft dampers.
,/using rigid metalvent.
,/that length of vent and number of elbows should be kept
to a minimum to provide efficient performance.
,/that size of vent should be uniform.
,/using duct tape to seal aii joints in tile vent system.
,/using cauIking compound to seal exterior wall or roof
opening around cap.
,/two elbows shouId not be instaIledtogether.
Wedo not recommend:
,/flexible metal vent.
NOTE:If fiexibie metal vent must be used,calculateeach
foot of fiexibie metai vent as two feet of rigid metalvent.
Flexibtemetalelbows count twice as much asstandard
elbows.
Vertical venting
Salida de aire per el cielo raso roof cap
caperuza decielo raso
(8.3x 25.4cm)
through-the-roof
atrav_sdelcielorasoperunorificio
de3-1/4"x10"(8.3 x 25.4 cm)
Wall venting
Salida de aire per la pared wa,oap
caperuzade pared
3-1/4" x 10" (8.3 x 25.4 cm)
through-the-wall
a tray,s de la pared per un orificio
de 3-1/4" x 10" (8.3 x 25.4 cm)
Round vent transition
TransiciOn de conducto de salida de aire redondo
6" (15.2 cm) rnin. diameter
round vent _ wall cap
conducto de salida de aire -_ ...... _JJcaperuza
redondo de 6" (15.2 cm) de _°'_ de pared
di_metro m[nimo
elbow
code
3" (7.6 cm) minimum height
(required for damper to fully open)
Altura minima de 3" (7.6 cm)
(necesaria paraque la compuerta
se abra completamente)
\
3-1/4" x 10"to 6"
(8.3 x 25.4 cm to 15.2 cm) round
vent transition
transici6n de conducto de salida de
aire redondo de 3-1/4" x 10"a 6"
(8.3 x 25.4 cm a 15.2 cm)
Salida de aire
La campanadel horno haside disefiada paraset instalada
sin saiida deaire (recircuiaciOn).Parasalida deaire en la
pared o en eI cieIo raso, @ben hacersecambios en et
sistema de satida de aire.
PRECAUCI6N: para reducir el riesgo de
incendio y para instalar el sistema de
salida de aire adecuado, asegQrese de
que el aire salga al exterior. No ponga la
salida de aire en espacios dentro de
paredes o cielos rases o en _ticos,
s6tanos de peque_ia altura o garajes.
Para m6todos de salidade aire a trav6s de ia pared o el cielo
raso:
Decidaentre instalar la salida de aire a tray@ del cielo raso
o de una pared.
Si se decideper et m6todo de salida de aire a trav6s de Ia
pared,asegOresede que hayael espacioadecuadodentro de
la pared parae!conducto de salida de aire.
No se incluyen los materialesdet conducto desalida de aire
que se necesitanpara la instalaciOn.
Recomendamos:
,/ Usartapas de paredy techo que tengan regulador de
contracorriente.
,/ usar un conducto de salida de aire met_iico y rigido.
7 que IaIongitud del conducto de saiida de aire y ei
nOmerode codes se mantengana un minimo para Iograr
un rendimiento eficiente.
7 que ias dimensiones dei conducto sean uniformes.
,/ usarcinta para conducto paraseiiar todas ias uniones en
ei sistema de saiidade aire.
,/ usar masiiia para caiafatearpara seiiar ia paredexterior o
la abertura en el cieio rasoalrededor de la caperuza.
,/ no se @ben instalar dos codes juntos.
No recomendamos:
,/conducto de salida de aire met_Iico flexible
NOTA:si debe usarse un conducto met_tico flexible, catcub
cadapie de conducto metAibo fiexibie comesi fueran dos
pies de conducto met_Iico rigido. Los codes de metal
flexible hacenper dos codes est_ndar. 6
Recommended ventlength:
Use 3-1/4" X 10" (8.3 x 25.4 cm) rectangular or 6" (15.7 cm)
round vent.
Thetotal length of the vent system including straight vent,
elbow, transitions, wail or roof caps must not exceedthe
equivalent of 140 feet (42.7 m) of 3-I/4" X 10" (8.3 x
25.4 cm) rectangular or 6" (15.7 cm) diameter round vent.
For best performance, useno more than three 90 degree
elbows.
Tocaicuiate the bngth of systemyou need,add the
equivalentfeet for eachventpiece usedin the system. See
the following examples:
3-1/4"x 10"(8.3 x 25.4 cm)
ventsystem:
1 - 3-1/4" x 10"
(8.3 x 25.4cm)
90° elbow =25 ft. (7.6 m)
1-walicap =40ft. (12.2m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
Length of 3-I/4" x 10"
(8.3 x 25.4 cm) system = 73 ft. (222 m)
6" (15.2 cm) vent system:
I - transition = 5 ft. (1.5 m)
2 - 90°eibows = 20 ft. (6.1 m)
1-waftcap =40ft. (12.2m)
8 ft. (2.4 m) straight = 8 ft. (2.4 m)
Length of 6" (152 cm)
system = 73 ft. (222 m)
If the existing vent is round, a rectangular-to-roundadapter
must be usedand a rectangular 3" (7.6 cm) extensionvent
betweenthe damper assemblyand adapter must be installed
to prevent damper from sticking.
Recommended standard fittings
Accesorios est_ndar recomendados
3d/4"x 10"to 6"= 5ft.
3.3x 25.4cma
15.7cm=1.5m)
3-1/4"x 10"a6"= 5pies
roofcap
caperuzadecieloraso
3-1/4"x10"= 24ft.
(8.3x25.4cm =7.3m)
3-1/4"x 10"= 24 pies
wailcap
caperuzadepared
1OfL 31/4 xlO 4Oft
(3m) 8.3x25Acm=12.2 m
10pies 3-1/4"x10"=40pies
45_elbow
codede45_
2
5
(1.5m)
5pies
90:elbow
3-1/4"x10"=25ft.
(8.3x 25.4cm =7.6m)
3-1/4"x10"=25pies
flatelbow
codeplane
3d/4"x lO"=lO ft.
&3x25.4sm=7.6m
3-1/4"x 10"=10 pies
3-1/4"x 10"(8.3 x 25,4 cm) vent system
Sistema de salida de aire de 3-1/4" x 10"
(8.3 x 25.4 cm)
90° elbow 6 ft.
6" (15.2 cm) vent system
Sistema de salida de aire de 6" (15.2 cm)
6 ft.
90° elbows ___ 6 pies ___
code de 90° (1.8 m) /
2ft, 2pies (0,6m)
JL
transition
traneici6n
wall cap
caperuza de
pared
Longitudrecemendada del cenductede salida de aire:
Use un conducto desalida de aire rectangular de 3-1/4" x
10"(8.3 x 25.4 cm) o redondo de6" (15.2 cm).
La iongitud totat detsistema de saiida de aire, inciuyendo el
conducto de saiida de aire recto, ei code, ias transiciones,
lascaperuzas de pared o cielo raso no deben excederei
equivaiente a 140 pies (42.7 m) de conducto rectangular de
saiida de aire de3-1/4" x 10" (8.3 x 25.4 cm) oconducto
redondo de 6" (15.2 cm) de di_metro.
Paramejores resuitados, no use mAsdetres codes de 90°.
Paracatcularia iongitud dei sistema que necesita,agregue
la equivabncia en pies para cadapedazo de conducto usa@
en etsistema. Yealos siguientes ejemplos:
Sistemade salida deaire de
3-1/4" x 10" (8.3 x 25.4 cm):
1-Codede 90°y
3-1/4" x 10"
(8.3 x 25.4cm) = 25 pies (7.6 m)
I - Caperuzade pared = 40 pies (12.2 m)
8 pies (2.4 m) recto = 8 pies (2.4 m)
Longitud de un sistema
de 3-1/4" x10" (8.3 x 25A m) = 73pbs (22.2m)
Sistema de salida de aire de 6" (15.2 cm):
1 - transici6n = 5 pies (1.5 cm)
2 - codes de 90° = 20 pies (6.1 cm)
I - caperuzade pared = 40 pies (12.2 m)
8 pies (2.4 m) recto = 8 pies (2.4 m)