Wolpac WOLVISION User manual

WOLVISION
TECHNICAL MANUAL
Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 1
Table of Contents
1. Presentation .....................................................................................................................2
2. Important safety instructions.............................................................................................3
3. Product description...........................................................................................................4
4. Equipment models............................................................................................................5
5. Equipment composition.....................................................................................................5
6. Technical specifications....................................................................................................7
7. Installation ........................................................................................................................8
8. Turning on equipment.....................................................................................................13
9. PCCS V Module –Electronic integration.........................................................................18
10. Usage instructions..........................................................................................................21
11. Wolvision Mechanism.....................................................................................................23
12. Preventive Maintenance .................................................................................................24
13. Lubricants and adhesives...............................................................................................25
14. Adjustments and technical interventions.........................................................................26
15. Exploded view of the Wolvision mechanism....................................................................27
16. Lista de Peças do Mecanismo Wolvision........................................................................28
17. Eletronic components list................................................................................................29
18. General dimensions........................................................................................................30
19. Warranty……………..……………………………………………………………………………32

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 2
1. Introduction
Wolpac, a company specialized in Access Control equipment, is proud to be recognized in the market for the
functionality and efficiency of its products, whose qualities and technical warranty are now at your disposal.
Additional clarifications, comments and suggestions on this manual can be obtained through the technical
support division exercised by our affiliate ATA SERVICE.
Site.: www.wolpac.com/assistenciatecnica
Make sure the version of this manual is the most up-to-date! Wolpac reserves the right to make any changes
to this document, or to the technical specifications of the product without prior or subsequent notification to
any organization.
Welcome to Wolpac Technology.

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 3
2. Important Safety Instructions
General Instructions
The main characteristics of Wolvision, how it is installed, and the precautions to be taken to ensure proper
operation are described in this manual. Read carefully before starting any type of operation to ensure the total
and full performance of the product.
Wolpac makes every effort to ensure that this manual is periodically reviewed and whenever significant
changes are made to the project. However, our continuous improvement policy may result in some minor
differences between the unit provided and the description provided in this document.
Electrical Precautions
The electrical energy used to supply this equipment has a voltage sufficient to endanger a person's life. Before
performing any maintenance or repair, you must ensure that the equipment has electrical insulation and
perform tests proving that this insulation is complete.
When the power supply cannot be interrupted, functional tests, maintenance and repairs of electrical units
must only be performed by persons fully qualified in relation to the hazard involved and that appropriate
precautions and training are taken.
Notes about Ownership
All information contained in this document is the property of Wolpac, possession of this manual and use of the
information is strictly limited to persons previously authorized by Wolpac.
Reproduction, transcription, server storage and translation into any language of this document or part thereof
is not permitted without prior authorization from Wolpac.
Changes to the Equipment
No product changes can be made without the authorization of Wolpac, who will be responsible for ensuring
that the proposed change is acceptable in safety and functionality aspects of the equipment. Only persons
authorized by Wolpac may make changes to the equipment.
Good Usage Practices
The equipment being installed should not be abandoned unless all potential electrical and mechanical hazards
have been safely remedied. A responsible person should be left in charge of the equipment when there is a
potential unsafe installation.
The following points below indicate good practices that will contribute to safety and avoid damage to the
equipment:
•Make sure that all electrical power is disconnected and disconnected before proceeding with any type
of work on the equipment;
•Never leave the equipment in a potential unsafe state;
•Only use the correct tools, preferably indicated in this manual;
•When working with the equipment, remove any jewelry that may be conductive, or clothing that may
become entangled in the mechanical parts of the equipment.
Important Notice
Wolvision is a safety product, any child or minor using the equipment should be supervised and accompanied
by a responsible adult. Wolpac is not responsible for any incidents if this rule is not applied.

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 4
3. Product Description
The Wolvision product is a glass door access control equipment used for medium flow (equal to or less than
2,000 cycles*/day) and medium security level, and can be used in both directions of passage, equipped with
an electronic control module capable of processing and providing information to the system in which the
equipment is integrated/interconnected.
The equipment can be configured to work in different states and installation positions, thus defining the flow
direction from A to B or vice versa, as specified by the customer.
The configuration of the operational status of the equipment is performed through the PCCS V control module
configuration software (supplied by Wolpac), through a RS-232 serial interface for communication with a
computer and Bluetooth for communication with a smartphone, the settings are made through PCCS V control
module software or configuration application, which is supplied by Wolpac.
The equipment operational commands can be carried out through digital signals (I/O) or through the available
serial port.
Applications:
•Companies
•Industries
•Schools
•Office Buildings
•Clubs
•Parks
Detail of installation positions and directions of passage
* Cycle definition: It is the passage of a user through the equipment, regardless of the direction of passage,
and can be determined by opening and closing the panels.
Installation position to
the left of the user
Installation position to the
right of the user

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 5
4. Equipment models
5. Equipment Composition
Glass 1840mm
Glass 870mm
Intermediary
Intermediary
Left
Left
Right
Right
Left
Left
Right
Right
Intermediary
Intermediary
Glass 870mm
Glass 870mm
Large Left
Large Left
Large Right
Large Right
Glass 870mm
Glass 1840mm
Wolvision Hybrid

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 6
Unit Type
Legend:
1. Font Bracket Assembly
2. PWDM II Master Bracket Assembly
3. Master PWSP Board Set
4. Support for Customer Integration
5. Card Collector Vault
6. Curved Glass Top
7. Integration Frame
8. Center Smoked Glass
9. PCCS V Board Holder
10. Painted carbon steel structure
11. PWDM II Slave Bracket Assembly
12. Tempered Glass Door
13. MECHANISM SHAFT
14. PWSP Slave Board Set
15. Finishes in Stainless Steel or Electrostatic Painting
16. Operation pictogram
WOLVISION RIGHT GLASS 870MM
WOLVISION LEFT GLASS 870MM

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 7
6. Technical Specifications
Material: Top 8 mm thick Tempered Smoked Glass
Cabinet AISI 304 Brushed Stainless Steel
Structur Carbon steel painted with epoxy powder paint
Panel Transparent tempered glass 10 mm thick
Center Glass Tempered Smoked glass 8 mm thick
Dimensions: See pages 29 and 30 of this manual
Installation: Right or left direction of passage (Fig. page4)
Functionality: Motorized for two-way passage control
Mechanism: Control of the operation of the equipment is performed by an
electromechanical mechanism located on the inside of the cabinet. Its locking
is automatic after a user passes through the equipment.
Power Outtage: In cases of power outtage or emergency events, the equipment was developed
so that the panels open automatically, leaving the passageway free for the
user, returning to its normal operation after the interruption of power is
restored.
Interface: The equipment is equipped with the control module called PCCS V,
responsible for controlling the user's passage, as well as the operational and
orientational signals, such as sound alarms and pictograms.
Power supply: Full range
Maximum consumption: 300 W
Protection Index: IP-42
MCEF (Mean cycles between failures): 5 million cycles
Working temperature: -5 to 50°C
Storage temperature: -10 to 55°C
Relative humidity: Max. 95% non-condensing
Approximate weight typical unit: 80 kg (Standard) and 82 kg (Large)
Installation Location: Do not install on escape routes or obstructing emergency exits.

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 8
7. Installation
Unpacking the product
When receiving the product at the installation site, check that all items are complete and undamaged. In case
of any damage caused by the transport of the product, the extent of the damage must be reported to the carrier
and, if necessary, report the incident to Wolpac.
Have the installation guide handy, which should be found inside the equipment packaging on the top cover.
Wolpac is not responsible for any injury or damage occurring due to noncompliance with the instructions
contained in this Technical Manual provided with the product.
Unpacking Instructions

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 9
Items and accessories
Note: All the tools necessary to install the equipment, as well as how to drill and mount the equipment
to the floor are described in the equipment installation guide.
Preparation of the floor
Before installing your equipment the following items should be checked:
•Conditions of the installation environment;
•Characteristics of the product's power supply;
•Physical space of the location;
•Cabling layout;
Environmental conditions
For the correct operation of the installed equipment, the following conditions should be found:
•Working temperature between -5 and 50°C
•Relative humidity not exceeding 95%
•Environment without any metal dust
•Environment without the presence of solid, liquid and gaseous polluting components that may corrode
cables and metal components of the equipment.
Caution!
Do not expose the equipment to poor weather conditions or direct sunlight.
General conditions of the floor
The floor must be flat with a slope tolerance of no more than 2% in the equipment installation area.
The concrete used must follow the resistance specifications and have a minimum layer of 100 mm at the
anchorage site of the anchor bolts.
Chemical anchor bolts can be used in cases where there is not enough concrete layer or on special floors
such as granite.
Conduits must be provided under the floor, with a minimum diameter of 1 ¼" (32 mm), providing passage
boxes at the points indicated in the installation drawing (Fig. page11).
Electrical connections
2 Equipment keys
6 Equipment ancho bolts
5/16 x 3 1/4'’

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 10
The electrical installation of this product must be performed by a qualified technical team. The
handling, installation and specifications of the cables must be in accordance with the instructions
based on this manual.
Basic preparation of the electrical installation
For Wolvision equipment two types of cabling are required:
•Power wiring
•Electrical interconnection wiring (accompanies the product)
Below are instructions for installing the equipment wiring:
•Floor conduits with a diameter of no less than 1 ¼” (32 mm).
•Install power and signal transmission conduits so that they are separated, avoiding possible noise
problems.
•Install conduits away from high voltage cabling or radio frequency cabling, electric motors and other
machines.
•Position the conduits as far away from the equipment anchor holes on the floor as possible.
•All power, communication and conduit cables are provided by the customer and must be in place prior
to installation (Excluding only the interconnection cable between the equipment, as this is provided
with the product).
•Check that the main power source is isolated.
Important!
In addition to powering the equipment, the grounding connection is essential for correct and safe
operation of the product.
Specifications
Conductive electrical cables with a minimum section of 1.5 mm² (14 AWG) should be used to supply the
equipment, connecting the equipment directly to the electrical power panel, without the use of outlets or
connectors.
The equipment accepts a variation of +/- 10% on the nominal value of the supply voltage, and the product
power source works at both 110 and 220V voltages.
Important!
For installations with large voltage oscillations it is recommended to use voltage stabilizers.

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 11
Mounting Detail
Sequence installation top view
WALL
WALL
PASSENGER BOX 4X4’’
POWER SUPPLY
PASSENGER BOX 4X4’’
COMMUNICATION
Connection Schemes

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 12

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 13
ON/OFF SWITCH
POWER SOURCE- FONTE –B
BATTERY 24V
RELAY
POWER SOURCE- FONTE-A2
ILLEGIVEL
DESIGN
CONFIRMED
APPROVED
TITTLE
PRODUCT
WOLVISION LINKING SCHEME PRODUCTS
WALPAC CODE
POWER CIRCUIT BREAKERS
AND BATTERY
PAG 1 OF 4
PAG 2 OF 4

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 14
GND GREEN
SV YELLOW
BROWN
ORANGE
WHITE
RELAY
MOSFET OUTPUT
BOTTOM LED STRIP- FITA LED INFERIOR- VCC
BOTTOM LED STRIP PAG 4
POWER SOURCE- A1
BROWN
MOSFET OUTPUT
INDUCTIVE BRAKE
JP1
CLOSED
RECORDING
WOLVISION LINKAGE SCHEME (MASTER)
HALL 2 BROWN
HALL 2 ORANGE
HALL1 WHITE
54 YELLOW
GND GREEN
PURPLE PHASE
GRAY PHASE
BLUE PHASE
CONNECTOR
CONNECTOR
COFRE- VAULT
POWER- A1
ON/OFF SWITCH
GND GREEN
SV YELLOW
PAG 3 OF 4

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 15
HALL 3 BROWN
HALL 2 ORANGE
HALL1 WHITE
INDUCTIVE BRAKE
INDEX YELLOW
ENCB GREEN
ENCA WHITE
GND BLACK
5V RED
JP1 CLOSED
LED SLAVE STRIP
PAG 4
ACTIVITY
DESIGN
CONFIRMED
APPROVED
NAME DATE
TITLE WOLVISION LINKAGE SCHEME
WOLPAC CODE
HALL 3 BROWN
HALL2 ORANGE
HALL 1 WHITE
5V AMARELO
GND GREEN
PURPLE PHASE
GREY PHASE
BLUE PHASE
ON/OFF SWITCH
POWER SOURCE B
EQUIPMENT ENTRANCE
WOLVISION LINKAGE SCHEME
SLAVE TOP LED STRIP B6
MASTER BOTTOM LED STRIP 30
MASTER BOTTOM LED STRIP 30
TOP LED STRIP B6
MASTER SWITCH REED PORTS
SLAVE SWITCH REED PORTS
ACTIVITY
DESIGN
CONFIRMED
APPROVED
TITLE WOLVISION LINKAGE SCHEME
WOLPAC CODE
NAME DATE
PAG 4 OF 4

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 16

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 17
8.Turning on the equipment
After performing the entire product installation stage, proceed with the following steps:
1. Check that the electrical interconnection was performed correctly; Refer to the wiring diagram for
more details.
Trigger the Equipment Circuit Breaker;
2. Turn on the equipment on/off switch;
3. After activating the power switch, check that the equipment performs the functions in the sequence
below:
a. An audible beep is activated for approximately 3 seconds, indicating the operation of all
photoelectric sensors;
b. Operational pictograms flash three times, displaying the three operational colors (green, red
and blue);
a. Again a beep is sounded, but this time for three times with the pictograms lit up in blue;
b. After the audible beep, the glass panels will move, performing the opening and closing cycle
for two consecutive times, in this case, observe the guidance pictograms that will indicate the
red color;
c. After the period of the previous item, the equipment will be locked in both directions with the
pictograms lit in blue.
Note: If any of the actions described do not take place, the interconnections must be checked, including
the connection of the grounding wire, as well as the presence of electricity. After the check, the steps must
be redone and if the problem persists, technical assistance should be contacted by e-mail
www.wolpac.com/assistenciatecnica.
Congratulations! The equipment is ready for use and integration!

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 18
9.Electronic Integration - PCCS V Module
The PCCS V control module is a microprocessed electronic set capable of integrating, in a complete way, any
proprietary access control system, with inputs and outputs for receiving signals to release passages and send
information to the operating control system, such as passages made and alarms. As it is a microprocessor set,
the control module can be configured according to specifications predefined by the system to be integrated,
for this the module has an RS-232, RS-485, CAN and Bluetooth interface for communication with a computer
or smartphone , the settings are made through the PCCS V control module configuration software or
application, supplied by Wolpac.
Smartphone Connection
To connect the PCCS V module, the Smartphone device must have Bluetooth enabled. When activating, it will
search for all available nearby devices and find Wolflap III, so just click and wait for pairing.
Once this is done, open the Wolpactec App. Okay, now the user has the Wolflap III in their hands, thus being
able to make pass releases, time out and other configurations with ease, this according to the existing
hardware or even according to operating requirements.
These same settings can be performed by the PT_PCCS V Software.
Using the configuration software
1. Install the setup program on your computer;
2. Connect communication cable between computer and PCCS V board connector P1;
3. Run the PT_PCCS V program.
4. Choose the serial port.
5. Start communication by clicking on the “Open COM” button.
Important!
The equipment purchased has a factory default configuration based on our experience of use. Make

Wolpac Efficient Controls Engineering Dept. MT-113 Apr/2021 Rev.: 01 Page 19
sure you really need to change this setting!
Pass release signal inputs
Release input signals can originate from dry contact. The following tables specify the LIB1 and LIB2 inputs.
Location of LIB2 and LIB1 signal inputs
Setting release signals
The release input signals can be originated on contact for low level (GND). Release inputs, LIB1
user right release and LIB2 user left release.
PCCS V connector
Wire no.
Signals
P2
1
LIB1
P2
5
VDD5
P2
2
LIB2
P2
6
VDD5
(*) isolated voltage = When the GND of the validation system is independent of the GND of the PWAC module
(*) non-isolated voltage = When the GND of the validation system is common to the GND of the PWAC module
The minimum width of the 200ms release pulse (not configurable via test program).
LIB1 and LIB2
Table of contents
Popular Fencing & Gate manuals by other brands

WamBam
WamBam PEEPING TOM VF16200 Assembly instructions

Zippity
Zippity Madison Gate Kit w/ Fence Wings Assembly instructions

Axelent
Axelent X-Guard D26 090 Series Assembly guide

G&G
G&G Paw Brothers PBP89430C Assembly instructions

BFT
BFT STOPPY Installation and user manual

Fortress Technologies
Fortress Technologies INSPIRE installation instructions

ENCLO
ENCLO Liberty Lattice ZP19052 Assembly instructions

Betafence
Betafence Nylofor City installation manual

Heras
Heras Euro-2 installation manual

Comunello Automation
Comunello Automation CONDOR 500 S Installation and user manual

Alvarado
Alvarado MSG Installation and maintenance instructions

WamBam