Installaon Instrucons and User Guide
Models Covered: C58107 & C58123
Please keep this booklet for future reference.
Installer, when you have read these instrucons please ensure you leave them with the user.
2Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Important Safety Informaon
Need help? Give us a call on 0330 0267 658 and speak to one of our trained advisors.
Please read these instrucons thoroughly and retain for future use.
All products supplied by Swan are safe provided they are installed, used correctly and receive regular maintenance in accordance with these
instrucons. If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualied
plumber.
Remove all packaging and check the components for damage before starng installaon. Before starng any installaon please consider the
following:
Prior to drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protecon
- Unplug equipment aer use
1. Idenfy all components before ng.
- 1 x Tap Body
- 1 x Washer
- 1 x ‘C’ Shaped Fixing Kit
- Flexi Tails (Pair) (C58107 Only)
- Copper Tails (Pair) (C58123 Only)
2. Fit the mixer to the sink using the ‘C’ shaped xing kit. The full
washer goes between the tap and the sink, and the ‘C’ shaped
rubber and metal washers on the underside of the sink.
3. Fit the tail pipes to the tap body (hand ghten only) and
connect the hot and cold supplies.
4. Fully open both valves, leng them run for a few minutes to
ush out the system. Check all joints and connecons for leaks.
Working Pressure Range: Min 0.2 bar, Max 5.0 bar
Maximum Stac Pressure: 10 bar
BS 6700 recommends the temperature of stored water
should never exceed 65°C. A stored water temperature
of 60°C is considered sucient to meet all requirements
and will minimise the build up of limescale in hard water
areas.
Specicaons
Installaon Steps
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fings) Regulaons 1999
and current byelaws. For full Installaon Requirements & Notes
(IRN) please visit www.wras.co.uk/directory.
Isolaon valves must be ed to the inlet water supplies to ensure
ease of future maintenance. Full access must be made available for
future maintenance/servicing purposes. Before installing this
product the water supply must be thoroughly ushed in order
to remove any swarf, solder etc.
This product must not be modied in any way as this will
invalidate the guarantee.
If in doubt, contact a registered plumber or your Local Water
Authority or the Secretary of the Instute of Plumbing,
address as follows:-
The Instute of Plumbing,
64 Staon Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Installaon
Tap Body
Washer
Fixing Rod
C
Kit - Rubber Washer
C
Kit - Metal Washer
Fixing Nut
Flexi Tails
3
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Maintenance
Chrome plate nish is in accordance with BS EN 248 and to maintain the surface nishes, simply wipe occasionally with a mild detergent on a so
damp cloth and dry using a so cloth. Never use abrasive cleaners or chemical household cleaners, and avoid contact with concentrated bleach.
Swan products are manufactured to the highest of standards and should require lile or no maintenance. In the unlikely event of any spare part
requirements, please contact our free phone helpline number which is 0330 0267 658.
Troubleshoong
1. Isolate the water supply using isolaon valves (not supplied) or by
turning o at the mains.
2. Remove the cap, screw, indice and handle using appropriate tools.
3. Remove the valves. Check O-Rings/Seals for any damage. If damaged
a replacement will be necessary.
Contact Customer Services on 0330 0267 658 for available spares.
4. If seals are not damaged, place in a suitable soluon and soak unl
fully de-scaled.
5. Fit the components back to the tap by following the steps in reverse.
Turn on the water supply and check connecons for any leaks.
Symptom Cause Remedy
No ow or low
ow rate
Parally closed isolaon valve. Open isolaon valve.
Instantaneous water heater cycles on and o as ow rate
or pressure is too low.
Increase water ow rate or pressure through system.
Water pressure is below the required minimum. Refer to specicaon for minimum pressure required.
Hot or cold water being drawn o elsewhere causing
pressure changes or instantaneous boiler temperature
changes.
Do not use other water outlets when using the taps.
Airlock or paral blockage in the supply pipework. Flush through pipework to ensure removal of debris and
any airlocks.
Water
dripping from
taps
This is normal for a short me aer using the taps. This is caused by residual water tension, the build up of
water in the tap body.
If water connues to drip, this is possibly due to debris on
the washer/valve.
Remove valves and clean, refer to 'Maintenance'
secon before starng any maintenance.
Taps do not
turn on
Closed isolaon valve. Open isolaon valve.
Mains water supply turned o. Turn on mains water supply.
Need help? Give us a call on 0330 0267 658 and speak to one of our trained advisors.
Cap
Indice
Screw
Handle
Valve
General Cleaning
Valve Cleaning
Wolseley
CV34 6DY
Website: www.wolseley.co.uk
Technical Helpline: 0330 0267 658
Issue: A
Part Number: C58107 & C58123
The complete Swan bathroom and kitchen product oering in Crosstop, Lever and Standard handle
designs are covered by a 5 year guarantee which covers retail purchasers against
manufacturing or material defects (subject to proof of purchase) but does not cover parts subject to
wear and tear. Mechanical parts subject to wear and tear are covered by a 12 month guarantee. The
chrome plated nish is covered under the same guarantee period of 5 years but is subject to the
cleaning instrucons being followed. The guarantee is not applicable where the product is ed
contrary to the condions in the ng instrucons.
Misuse and accidental damage to the product are not covered by this guarantee. The extent of this
liability is limited to the cost of the replacement of the defecve item and not to the ng or conse-
quenal damages.
Guarantee

This manual suits for next models

1

Other WOLSELEY Kitchen & Bath Fixture manuals

WOLSELEY Swan C58100 Mounting instructions

WOLSELEY

WOLSELEY Swan C58100 Mounting instructions

WOLSELEY C58104 Mounting instructions

WOLSELEY

WOLSELEY C58104 Mounting instructions

Popular Kitchen & Bath Fixture manuals by other brands

Kohler K-6606 installation guide

Kohler

Kohler K-6606 installation guide

Hans Grohe PuraVida 15070 1 Series Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe PuraVida 15070 1 Series Installation/User Instructions/Warranty

RUVATI TERRAZA RVH9540 quick start guide

RUVATI

RUVATI TERRAZA RVH9540 quick start guide

Toto TLP03301 Operation manual

Toto

Toto TLP03301 Operation manual

Yosemite Home Decor YPH2B258 Series quick start guide

Yosemite Home Decor

Yosemite Home Decor YPH2B258 Series quick start guide

Sanipex BAGNO DESIGN BRISTOL BDM-BIS-412 Series installation guide

Sanipex

Sanipex BAGNO DESIGN BRISTOL BDM-BIS-412 Series installation guide

Lefroy Brooks M1-2154 Installation, operating,  & maintenance instructions

Lefroy Brooks

Lefroy Brooks M1-2154 Installation, operating, & maintenance instructions

newform sensitive 66705 instructions

newform

newform sensitive 66705 instructions

Villeroy & Boch Dornbracht 36 104 960 installation instructions

Villeroy & Boch

Villeroy & Boch Dornbracht 36 104 960 installation instructions

Sanipex BAGNO DESIGN BDM-SES-440 Series installation guide

Sanipex

Sanipex BAGNO DESIGN BDM-SES-440 Series installation guide

Axor Starck Organic 1241000 Series Instructions for use and assembly instructions

Axor

Axor Starck Organic 1241000 Series Instructions for use and assembly instructions

agape MACH2 AMC20941 Assembly instructions

agape

agape MACH2 AMC20941 Assembly instructions

Abode Pico Monobloc AT1226 quick start guide

Abode

Abode Pico Monobloc AT1226 quick start guide

Kraus Urbix KPF-3125-FF-101BG installation manual

Kraus

Kraus Urbix KPF-3125-FF-101BG installation manual

DuschWelten MK 150 5808 Assembly instructions

DuschWelten

DuschWelten MK 150 5808 Assembly instructions

American Standard DELANCEY 4279.701 installation instructions

American Standard

American Standard DELANCEY 4279.701 installation instructions

Hans Grohe Focus E 31740000 Assembly instructions

Hans Grohe

Hans Grohe Focus E 31740000 Assembly instructions

baliv 40 Series manual

baliv

baliv 40 Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.