Wow WAC 1200PLUS User manual

2186 - 07/14 ed.03
Anleitung Flushingkit
WAC 1200PLUS / WAC 2200


INSTRUCTIONS MANUAL
-3-
A/C SYSTEM FLUSHING KIT
Attention: before flushing, recover the refrigerant of the a/c system using a suitable R&R
machine, then run at least 20 minutes vacuum.
PRINCIPAL COMPONENTS
Refer to Fig.1:
a) a) 6,5l accumulator
a1. filter
a2. inlet
a3. outlet
a4. oil drain
a5. safety valve
b) Clip connections
c) N°2 Check valves
d) A/C adapter fitting (*)
e) Black hose 2,5m 3/8SAE F - 3/8SAE F
f) N°2 Black hoses 150mm with 3/8 SAE F connections
g) N°2 Yellow hoses 150mm with 3/8 SAE F – M12x1,5 F connections
h) N°2 Black hoses 150mm with 3/8 SAE F – M14x1,5 F connections
(*) not supplied with this kit, refer to vehicle manufacturer
ASSEMBLY OF THE FLUSHING KIT
Consider 4 assembly configurations, It can be used with R&R machines with automatic valves
or manual valves and for both gases R134a or R1234yf
1- R134A MANUAL VALVES
Refer to Fig.2, operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the Black hose 150mm (g), to the check valve (c)
with orientation as showed in the figure and to the black hose 150mm (e).
3) Connect the other terminal of the Black hose 150mm (e) to the outlet (a3) of the 6,5l
accumulator (a)
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a)
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b)
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the Black hose 150mm (g), to the check valve (c)with
orientation as showed in the figure and to the black hose 150mm (e).
8) Connect the other terminal of the black hose 150mm (e) to the Clip connection (b)

INSTRUCTIONS MANUAL
-4-
2- R1234YF MANUAL VALVES
Refer to Fig.2, operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the yellow hose 150mm (f), to the check valve (c)
with orientation as showed in the figure and to the black hose 150mm (e).
3) Connect the other terminal of the Black hose 150mm (e) to the outlet (a3) of the 6,5l
accumulator (a)
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a)
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b)
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the yellow hose 150mm (f), to the check valve (c) with
orientation as showed in the figure and to the black hose 150mm (e).
8) Connect the other terminal of the black hose 150mm (e) to the Clip connection (b).
3- R134A AUTOMATIC VALVES
Refer to Fig.3,operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the Black hose 150mm (g);
3) Connect the other terminal of the Black hose 150mm (g) to the outlet (a3) of the 6,5l
accumulator (a);
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a);
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b);
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the Black hose 150mm (g);
8) Connect the other terminal of the Black hose 150mm (g) to the Clip connection (b).
4- R1234YF AUTOMATIC VALVES
Refer to Fig.3, operate as follow:
1) Disconnect the quick coupling from the blue hoses (LP) of the R&R machine
2) Connect the blue hose (LP) to the yellow hose 150mm (f);
3) Connect the other terminal of the yellow hose 150mm (f) to the outlet (a3) of the 6,5l
accumulator (a)
4) Connect the Black hose 2,5m (d) to the inlet (a2) of the 6,5l accumulator (a)
5) Connect the other terminal of the Black hose 2,5m (d) to the Clip connection (b)
6) Disconnect the quick coupling from the red hoses (HP) of the R&R machine
7) Connect the red hose (HP) to the yellow hose 150mm (f);
8) Connect the other terminal of the yellow hose 150mm (f) to the Clip connection (b).

INSTRUCTIONS MANUAL
-5-
CONNECTION TO THE SYSTEM
Refer to Fig.4.
1) Use the correct seat of the rotating disk for the section of the component to be
connected to the rubber cone.
2) Connect the rubber cone of the clip from the red hose (HP) to the inlet of the
component to be flushed, and the clip from the blu hose (LP) to the outlet of the
component to be flushed.
NOTE: could be used also a adapter fitting (ref.C, fig.1) if supplied by the vehicle
manufacturer (Refer to Fig.5)
ENABLING THE FLUSHING KIT
If flushing kit must be enabled (not always, depending on machine model), select OPTIONS
(under CONFIGURATION or SETUP), then enter the code 43210791.
Select A/C SYSTEM FLUSHING, then enter the requested ACTIVATION CODE (retrieved with
the option kit). If the enabler code is not available, call the Service Center.
USING THE FLUSHING KIT
When flushing a system we recommend disassembling the filter and the expansion valve, in
the case of a traditional system, or only the capillary valve in the case of a flooded system. Use
the inlet to the evaporator as washing inlet and the outlet of the condenser as flushing outlet.
1 – MANUAL
In order to flush the A/C system (or one component) using any station recovery-recycling and
operate as follows:
1) Do 10 minutes of vacuum inside the system (or component)
2) Make a filling of 2 to 3 kg of refrigerant
3) Recover the filled refrigerant
4) Drain the oil (separated during recovery)
perform steps 2, 3 and 4 for three times, after which check the oil discharged from the last
cycle, if greater than 10cc make a further round of filling - recycling - waste oil (as in
paragraphs 2, 3 and 4 ).
After the washing operation, disconnect everything and unplug the machine from the power
supply.
NOTE: Every three or four washes remove the cylinder Y filter cap of the receiver, remove the
filter inside and clean it with compressed air.

INSTRUCTIONS MANUAL
-6-
2 – AUTOMATIC (machine w/ alphanumeric screen)
Switch the machine on. The MAIN MENU will appear after a few seconds:
Select ASSISTED PROCEDURE.
Scroll with the down arrow (↓) and select A/C SYSTEM FLUSHING.
You may type in the vehicle license plate number and confirm with ENTER.
select the desired amount of refrigerant, then press ENTER
Press ENTER.
Empty the used oil container, the press START.
At this point, the machine will proceed automatically. When flushing is completed, disconnect
all the couplings and disconnect the machine from the power supply.
Amount of gas to use for
every cycle
xxx g
press ENTER
A/C SYSTEM FLUSHING
Empty the container
Used oil and
press START
A/C System flushing.
Gas inject. xx g
ACp xxx bar
Connect the flushing kit
and open HP and LP.
press ENTER
INSERT PLATE NO.
. . . . . . . . . .
RECOVERY / RECYCLING
VACUUMN X min
OIL X ml
TRACER X ml
FILLING XX g
A/C SYSTEM FLUSHING
AUTOMATIC PROCEDURE
ASSISTED PROCEDURE
DATA AND CONFIGURAT.
MAINTENANCE

INSTRUCTIONS MANUAL
-7-
3 – AUTOMATIC (machine w/ manual valves and graphic b/n screen)
From ASSISTED PROCEDURE, scroll down with the DOWN ARROW , select “A/C System
Flushing”,:
press ENTER , the following screen will be displayed:
press ENTER , the following screen will be displayed:
Use DOWN ARROW and UP ARROW to select the desired amount, then press ENTER
to confirm. NOTE: selectable amount (steps of 500 g) between 1000 and 7500 grams
press START , the following screen will be displayed:
A/C SYSTEM FLUSHING
Open high and low
Pressure taps, then
Press F1 to continue
F2 to Exit
A/C SYSTEM FLUSHING
Connect the flushing
kit as explained in
manual
Press F1 to continue
F2 to Exit
A/C SYSTEM FLUSHING
Flushing refrigerant
Total amount
xxxx g
Press F4
A/C SYSTEM FLUSHING
Vacuum
xx min
Press F4
ASSISTED PROCEDURE
Purification
Bottle Filling
Air Purge
A/C System Flushing
Dynamic Diagnosis
Static Diagnosis

INSTRUCTIONS MANUAL
-8-
press START , the machine will proceed automatically, displaying the quantity of oil
extracted and printing the total volume at the end of flushing. When flushing is completed,
disconnect all the couplings and disconnect the machine from the power supply.

INSTRUCTIONS MANUAL
-9-
4 – AUTOMATIC (machine w/ automatic valves and graphic b/n screen)
From main menu:
Select ASSISTED PROCEDURE , the following screen is displayed (only if the hardware
for hybrid vehicles is installed in the machine).
Press ENTER to confirm STANDARD VEHICLE or press the down arrow ↓ and then ENTER
to select HYBRID VEHICLE.
Scroll down with the DOWN ARROW , select “A/C System Flushing”:
press ENTER , the following screen will be displayed:
press START , the following screen will be displayed:
AUTOMATIC PROCEDURE
Vacuum xx
Oil xx
Tracer Dye xx
Nitrogen Test xx
Gas Filling xxg
SELECT
Standard vehicle
Hybrid vehicle
A/C SYSTEM FLUSHING
Connect and open HP
and LP coupling to
A/C system
F1 to continue
F2 to exit
ASSISTED PROCEDURE
Purification
Bottle Filling
Air Purge
A/C System Flushing
Dynamic Diagnosis
Static Diagnosis

INSTRUCTIONS MANUAL
-10-
press START , the following screen will be displayed:
press START , the following screen will be displayed:
press START , the following screen will be displayed:
the machine will proceed automatically, displaying the quantity of oil extracted and printing the
total volume at the end of flushing. When flushing is completed, disconnect all the couplings
and disconnect the machine from the power supply.
A/C SYSTEM FLUSHING
Empty used oil
container
F1 to continue
F2 to exit
A/C SYSTEM FLUSHING
Oil extraction
Number of cycles: x
Acp x.x bar
A/C SYSTEM FLUSHING
It is necessary to
replenish lubricant
prior to start the
A/C system
F1 to continue
F2 to exit
A/C SYSTEM FLUSHING
This operation
completely remove
all the lubricant
from the A/C system
compressor.
F1 to continue

INSTRUCTIONS MANUAL
-11-
5 – AUTOMATIC (machine w/ 5” color screen)
Attention: before flushing, recover the refrigerant of the a/c system using a suitable R&R
device, then run at least 20 minutes vacuum. When flushing a system we recommend
disassembling the filter and the expansion valve, in the case of a traditional system, or only the
capillary valve in the case of a flooded system. Use the inlet to the evaporator as washing inlet
and the outlet of the condenser as flushing outlet.
From DEVICES, select A/C SYSTEM FLUSHING, the following screen will be displayed:
If needed, type the new value; then press OK to continue, the following screen will be
displayed:
Connect the flushing kit as described previously, then press OK to begin the flushing operation:
The machine will proceed automatically, displaying the quantity of oil extracted and printing the
total volume at the end of flushing. When flushing is completed, the following screen is
displayed:
Press OK, disconnect all the couplings and disconnect the machine from the power supply.
A/C SYSTEM FLUSHING
Amount of gas to use for every cycle:
xxxx g
Press OK
R134a DEVICES
A/C SYSTEM FLUSHING
connect flushing-kit as illustrated below and
press OK
R134a DEVICES
A/C SYSTEM FLUSHING
A/C system flushing in progress…
R134a DEVICES
A/C SYSTEM FLUSHING
end of flushing, press OK
R134a DEVICES
A/C SYSTEM FLUSHING

INSTRUCTIONS MANUAL
-12-
6 – AUTOMATIC (machine w/ 7” touchscreen)
When flushing a system we recommend disassembling the filter and the expansion valve, in
the case of a traditional system, or only the capillary valve in the case of a flooded system. Use
the inlet to the evaporator as washing inlet and the outlet of the condenser as flushing outlet.
From MAINTENANCE, select A/C SYSTEM FLUSHING, the following screen will be
displayed:
NOTE: press for additional information about amount of gas
If needed, select the textbox to change the amount of refrigerant, type the new value; then
press OK to continue, the following screen will be displayed:
Connect the flushing kit as described previously, then press OK to begin the flushing operation:
The machine will proceed automatically, displaying the quantity of oil extracted and printing the
total volume at the end of flushing. When flushing is completed, the following screen is
displayed:
Press OK, disconnect all the couplings and disconnect the machine from the power supply
FLUSHING
–
OPERATION COMPLETED
FLUSHING KIT CONNECTION
connect flushing-kit as illustrated
below and press O
K
A/C SYSTEM FLUSHING
A/C system flushing in progress…
A/C system pressure - 0.7 bar (rel)
CHECKING LEACKS IN VACUUM
CHECKING LEACKS IN VACUUM
End of flushing
R134a MAINTENANCE
A/C SYSTEM FLUSHING
Amount of gas to use for every cycle:
R134a MAINTENANCE
R134a MAINTENANCE
R134a MAINTENANCE

MANUEL D’INSTRUCTIONS
-13-
KIT DE RINÇAGE DU SYSTÈME A/C
Attention : avant de rincer, récupérer le réfrigérant du système a/c en utilisant une machine
R&R appropriée, puis faites fonctionner au moins 20 minutes sous vide.
COMPOSANTS PRINCIPAUX
Reportez-vous à la Figure 1 :
a) accumulateur 6,5 l
a1. filtre
a2. admission
a3. sortie
a4. vidange d'huile
a5. soupape de sécurité
b) Connexions clip
c) N° 2 clapets anti-retour
d) Raccord adaptateur (*)
e) Tuyau noir 2,5 m 3/8 SAE F - 3/8SAE F
f) N° 2 tuyaux noirs 150 mm avec connexions 3/8 SAE F
g) N° 2 tuyaux jaunes 150 mm avec connexions 3/8 SAE F - M12x1, 5 F
h) N° 2 tuyaux noirs 150 mm avec connexions 3/8 SAE F - M14x1, 5 F
(*) N'est pas fourni avec ce kit, reportez-vous au fabricant du véhicule
MONTAGE DU KIT DE RINÇAGE
Considérez 4 configurations de montage, il peut être utilisé avec des machines R&R avec des
vannes automatiques ou manuelles et pour les deux gaz R134a ou R1234yf
1- VANNES MANUELLES R134A
Vous reportant à la figure 2, opérer comme suit :
1) Débrancher le raccord rapide des tuyaux bleus (LP) de la machine R&R
2) Connecter le tuyau bleu (LP) au tuyau noir 150mm (g), au clapet anti-retour (c) avec
l’orientation montrée dans la figure et au tuyau noir 150mm (e).
3) Brancher l'autre borne du tuyau noir 150mm (e) à la sortie (a3) de l'accumulateur
6,5 l (a)
4) Connecter le tuyau noir 2,5 m (d) à l'entrée (a2) de l’accumulateur 6,5 l (a)
5) Connecter l'autre borne du tuyau noir 2,5 m (d) à la connexion Clip (b)
6) Débrancher le raccord rapide des tuyaux rouges (HP) de la machine R&R
7) Connecter le tuyau rouge (HP) au tuyau noir 150 mm (g), au clapet anti-retour (c)
avec l’orientation montrée dans la figure et au tuyau noir 150 mm (e).
8) Brancher l'autre borne au tuyau noir 150 mm (e) à la connexion Clip (b)

MANUEL D’INSTRUCTIONS
-14-
2- VANNES MANUELLES R1234YF
Vous reportant à la figure 2, opérer comme suit :
1) Débrancher le raccord rapide des tuyaux bleus (LP) de la machine R&R
2) Connecter le tuyau bleu (LP) au tuyau jaune150 mm (f), au clapet anti-retour (c)
avec l’orientation montrée dans la figure et au tuyau noir 150 mm (e).
3) Brancher l'autre borne du tuyau noir 150 mm (e) à la sortie (a3) de l'accumulateur
6,5 l (a)
4) Connecter le tuyau noir 2,5 m (d) à l'entrée (a2) de l’accumulateur 6,5 l (a)
5) Connecter l'autre borne du tuyau noir 2,5 m (d) à la connexion Clip (b)
6) Débrancher le raccord rapide des tuyaux rouges (HP) de la machine R&R
7) Connecter le tuyau rouge (HP) au tuyau jaune 150 mm (f), au clapet anti-retour (c)
avec l’orientation montrée dans la figure et au tuyau noir 150 mm (e).
8) Brancher l'autre borne au tuyau noir 150 mm (e) à la connexion Clip (b)
3- VANNES AUTOMATIQUES R134A
Vous reportant à la figure 3, opérer comme suit :
1) Débrancher le raccord rapide des tuyaux bleus (LP) de la machine R&R
2) Connecter le tuyau bleu (LP) au tuyau noir 150 mm (g) ;
3) Brancher l'autre borne du tuyau noir 150 mm (g) à la sortie (a3) de l'accumulateur
6,5 l (a) ;
4) Connecter le tuyau noir 2,5 m (d) à l'entrée (a2) de l’accumulateur 6,5 l (a) ;
5) Connecter l'autre borne du tuyau noir 2,5 m (d) à la connexion Clip (b)
6) Débrancher le raccord rapide des tuyaux rouges (HP) de la machine R&R
7) Connecter le tuyau rouge (HP) au tuyau noir 150 mm (g) ;
8) Brancher l'autre borne du tuyau noir 150 mm (g) à la connexion Clip (b)
4- VANNES AUTOMATIQUES R1234YF
Vous reportant à la figure 3, opérer comme suit :
1) Débrancher le raccord rapide des tuyaux bleus (LP) de la machine R&R
2) Connecter le tuyau bleu (LP) au tuyau noir 150 mm (f) ;
3) Brancher l'autre borne du tuyau jaune 150 mm (f) à la sortie (a3) de l'accumulateur
6,5 l (a)
4) Connecter le tuyau noir 2,5 m (d) à l'entrée (a2) de l’accumulateur 6,5 l (a)
5) Connecter l'autre borne du tuyau noir 2,5 m (d) à la connexion Clip (b)
6) Débrancher le raccord rapide des tuyaux rouges (HP) de la machine R&R
7) Connecter le tuyau rouge (HP) au tuyau jaune 150 mm (f) ;
8) Brancher l'autre borne du tuyau jaune 150 mm (f) à la connexion Clip (b)

MANUEL D’INSTRUCTIONS
-15-
CONNEXION AU SYSTÈME
Reportez-vous à la Fig. 4.
1) Utiliser le correct siège du disque en rotation pour raccorder la section du
composant au cône de caoutchouc.
2) Raccorder le cône en caoutchouc du clip du tuyau rouge (HP) à l'entrée du
composant à rincer, et le clip du tuyau bleu (LP) à la sortie de l'élément à rincer.
REMARQUE : pourrait être utilisé également un raccord adaptateur (réf. C, fig.1) si fourni
par le constructeur du véhicule (Reportez-vous à la figure 5)
ACTIVER LE KIT DE RINÇAGE
Si le kit de rinçage doit être activé (pas toujours, selon le modèle de la machine), sélectionner
OPTIONS (sous CONFIGURATION ou SETUP), puis entrer le code 43210791.
Sélectionner RINÇAGE DU SYSTÈME A/C, puis entrer le CODE D'ACTIVATION demandé
(récupéré avec le kit en option). Si le code d'activation n'est pas disponible, appeler le Centre
de Service.
UTILISER LE KIT DE RINÇAGE
Lors du rinçage d'un système, nous recommandons de démonter le filtre et la vanne
d'expansion, dans le cas d'un système traditionnel, ou seulement le tube capillaire dans le cas
d'un système submergé. Utiliser l'entrée de l'évaporateur comme entrée de lavage et la sortie
du condenseur comme sortie de rinçage.
1 - MANUEL
Pour rincer le système A/C (ou un composant) en utilisant une station de récupération-
recyclage et procéder comme suit :
1) Faire le vide pendant 10 minutes à l'intérieur du système (ou composant)
2) Remplir avec 2 à 3 kg de fluide frigorigène
3) Récupérer le fluide frigorigène rempli
4) Vidanger l'huile (séparée lors de la récupération)
effectuer les étapes 2, 3 et 4 trois fois, après quoi vérifier l'huile déchargée du dernier cycle, si
supérieure à 10cc faire un nouveau cycle de remplissage - recyclage - huiles usagées (comme
dans les paragraphes 2, 3 et 4).
Après l'opération de lavage, débrancher tout et débrancher l'appareil de l'alimentation
électrique.
REMARQUE: Tous les trois ou quatre lavages enlever le bouchon du filtre du cylindre Y du
récepteur, retirer le filtre à l'intérieur et le nettoyer à l'air comprimé.

MANUEL D’INSTRUCTIONS
-16-
2 – AUTOMATIQUE (machine avec écran alphanumérique)
Allumer la machine. Le MENU PRINCIPAL s'affiche au bout de quelques secondes :
Sélectionner PROCÉDURE ASSISTÉE.
Faire défiler avec la flèche vers le bas (↓) et sélectionner RINÇAGE DU SYSTÈME A/C.
Vous pouvez saisir le numéro de la plaque d'immatriculation du véhicule et confirmer avec
ENTRER.
sélectionner la quantité désirée de fluide frigorigène, puis appuyer sur ENTRER
Appuyer sur ENTRER.
Vider le réservoir d'huile usée, puis appuyer sur START.
À ce moment-là, la machine va procéder automatiquement. Lorsque le rinçage est terminé,
débrancher tous les raccords et débrancher la machine de l'alimentation électrique.
Quantité de gaz à utiliser
pour chaque cycle
xxx g
appuyer sur ENTRER
SYSTÈME DE RINÇAGE A/C
Vider le réservoir
Huile usagée et
appuyer sur START
Système de rinçage A/C.
Inject. de gaz xx g
ACp xxx bar
Brancher le kit de rinçage
et ouvrir HP et LP.
appuyer sur ENTRER
INSÉRER PLAQUE NO.
. . . . . . . . . .
RÉCUPERATION / RECYCLAGE
VIDE X min
HUILE X ml
TRACEUR X ml
REMPLISSAGE XX g
RINÇAGE DU SYSTÈME A/C
PROCÉDURE AUTOMATIQUE
PROCÉDURE ASSISTÉE
DONNÉES ET CONFIGURAT.
MAINTENANCE

MANUEL D’INSTRUCTIONS
-17-
3 – AUTOMATIQUE (machine avec/ vannes manuelles et écran
graphiques n/b)
Dans PROCÉDURE ASSISTÉE, faire défiler avec la FLÈCHE VES LE BAS , sélectionner
« Rinçage du système A/C » :
Appuyer sur ENTRER , l’écran suivant va s’afficher :
appuyer sur ENTRER , l’écran suivant va s’afficher :
Utiliser la FLÈCHE VERS LE BAS et HAUT pour sélectionner la quantité désirée, puis
appuyer sur ENTRER pour confirmer. REMARQUE : quantité sélectionnable (pas de 500 g)
entre 1 000 et 7 500 grammes
appuyer sur START , L’écran suivant va s’afficher :
RINÇAGE DU SYSTÈME
A/C
Connecter le kit de
rinçage comme
expliqué dans le
manuel
Appuyer sur F1 pour
continuer
RINÇAGE DU SYSTÈME
A/C
Réfrigérant de
rinçage
Quantité total
xxxx g
Appuyer sur F4
RINÇAGE DU SYSTÈME
A/C
Vide
xx min
Appuyer sur F4
PROCÉDURE ASSISTÉE
Purification
Remplissage de
bouteilles
Purge d'air
Rinçage du système
A/C
Di ti d i

MANUEL D’INSTRUCTIONS
-18-
appuyer sur START , la machine va procéder automatiquement et affiche la quantité d'huile
extraite et imprime le volume total à la fin du rinçage. Lorsque le rinçage est terminé,
débrancher tous les raccords et débrancher l'appareil de l'alimentation électrique.
RINÇAGE DU SYSTÈME
A/C
Ouvrir les prises
de haute et basse
pression, puis
appuyer sur F1 pour
continuer
F2 pour Quitter

MANUEL D’INSTRUCTIONS
-19-
4 – AUTOMATIQUE (machine avec automatique vannes et écran
graphique n/b)
Dans le menu principal :
Sélectionner PROCÉDURE ASSISTÉE , l’écran suivant est affiché (seulement si le
matériel pour les véhicules hybrides est installé dans la machine).
Appuyer sur ENTRER pour confirmer VÉHICULE STANDARD ou appuyer sur la flèche vers le
bas ↓ et ensuite sur ENTRER pour sélectionner VÉHICULE HYBRIDE.
Faire défiler avec la FLÈCHE VERS LE BAS , sélectionner « Rinçage du système A/C » :
appuyer sur ENTRER , l’écran suivant va s’afficher:
appuyer sur START , l’écran suivant va s’afficher :
AUTOMATIC PROCEDURE
Vacuum xx
Oil xx
Tracer Dye xx
Essai azote xx
Remplissage de gaz
xxg
S
É
LECTIONNE
R
Véhicule standard
Véhicule hybride
RINÇAGE DU SYSTÈME A/C
Connecter et ouvrir
l’accouplement HP et
LP au système A/C
F1 pour continuer
F2 pour quitter
PROCÉDURE ASSISTÉE
Purification
Remplissage de
bouteilles
Purge d’air
Rinçage du système
A/C

MANUEL D’INSTRUCTIONS
-20-
appuyer sur START , l’écran suivant va s’afficher :
appuyer sur START , l’écran suivant va s’afficher:
appuyer sur START , l’écran suivant va s’afficher:
la machine va procéder automatiquement et affiche la quantité d'huile extraite et imprime le
volume total à la fin du rinçage. Lorsque le rinçage est terminé, débrancher tous les raccords et
l'appareil de l'alimentation électrique.
RINÇAGE DU SYSTÈME A/C
Conteneur
d
e l'huile
usagée vide
F1 pour continuer
F2 pour quitter
RINÇAGE DU SYSTÈME A/C
Extraction d’huile
Nombre de cycles : x
Acp x.x bar
RINÇAGE DU SYSTÈME A/C
Il est nécessaire de
renouveler le
lubrifiant, avant de
démarrer le système
A/C
F1 pour continuer
F2 pour quitter
RINÇAGE DU SYSTÈME A/C
Cette opération
supprime
complètement tout le
lubrifiant du
compresseur du
système A/C.
F1 pour continuer
This manual suits for next models
1
Table of contents
Languages:
Popular Air Conditioner manuals by other brands

Panasonic
Panasonic CS-E15NKE3 operating instructions

Daikin
Daikin FTKS50EV1B Operation manual

Olimpia splendid
Olimpia splendid maeStro Pro Instructions for installation, use and maintenance

Haier
Haier HDU-42HT03/H Operating & installation manual

Sanyo
Sanyo STB0811C1-S parts list

EcoNet
EcoNet A2024AJVCA installation instructions

Haier
Haier AS072AIAAA Operation manual

Mitsubishi
Mitsubishi PQHY-P200YGM-A installation manual

Panasonic
Panasonic CS-BE25TKE-1 operating instructions

GE
GE AEZ10AVL1 Owner's manual and installation instructions

Samsung
Samsung MH18VP2-09 Owner's instructions

Friedrich
Friedrich 0 Installation and operation manual