XTA ULTRAFIDE U500DC User manual

1
www.ultradeaudio.co.uk
U500DC
Ultra Fidelity Audiophile
Power Amplier.
Operators Manual

2
Thank you for choosing an ULTRAFIDE/MC² product for
your application, it really is appreciated.
Please spend a little time reading through this manual,
so that you obtain the best possible performance
from the unit and become familiar with its operating
requirements.
All ULTRAFIDE/MC² products are carefully designed and
engineered for world-class performance and reliability.
If you would like further information about this or any
other product, please contact us:
hello@ultra deaudio.co.uk
We wish you many years of enjoyment from your new
ampli er and look forward to hearing from you in the
near future.
Scan the QR code or visit our website
www.ultra deaudio.co.uk to nd out
more about us.
www.ultra deaudio.co.uk

3
Contents
Declaration of Conformity .............................................................................................. 4
Introduction ..................................................................................................................... 5
Safety............................................................................................................................... 6
Installing .......................................................................................................................... 7
Basic Connections Set-up | AC mains power................................................................ 8
XLR/RCA connectors...................................................................................................... 9
Binding posts | Cable types required ...........................................................................10
Front and rear diagram .................................................................................................11
Other controls | Internal gain | Internal mains calibration ..........................................12
Operation and maintenance.........................................................................................13
Warranty information....................................................................................................13
Technical Specications...............................................................................................14
Quick start guide...........................................................................................................15

4
3| Page
DECLARATION OF CONFORMITY
We, the manufacturer:
XTA Electronics Ltd
(TRADING AS MC2 Audio, Ultrafide)
Units 6-7 Kingsgate
Heathpark Industrial Estate
Honiton, Devon
England
EX14 1YG
acknowledge our responsibility and self-certify the following products:
Kind of equipment: Audio amplifier
Commodity Code: 8518400090
Type Designation: U500DC
and all OEM/variants of this model
are manufactured in accordance with EMC Directive 2014/30/EU (CE and UKCA), in compliance with the
following norm(s) or document(s):
Technical Regulations: EN55032:2015 (Emissions)
EN55032:2017 (Immunity)
and in accordance with the: Low Voltage Directive 2014/35/EU (CE and UKCA)
in compliance with the following norm(s) or document(s):
Technical Regulations: EN/IEC62368-1:2020 (Audio, Video & Communication Safety)
and in accordance with the Directive 2011/65/EU on the restricted use of certain Hazardous
Substances in Electrical and Electronic Equipment (RoHS2). We certify that the above-mentioned products are
deemed compliant according to the details given in the directive.
Signed:
Name: Alex Cooper
Position: Research and Development Manager
Date: May 2022

5
3 | Page
DECLARATION OF CONFORMITY
We, the manufacturer:
XTA Electronics Ltd
(TRADING AS MC2 Audio, Ultrafide)
Units 6-7 Kingsgate
Heathpark Industrial Estate
Honiton, Devon
England
EX14 1YG
acknowledge our responsibility and self-certify the following products:
Kind of equipment: Audio amplifier
Commodity Code: 8518400090
Type Designation: U500DC
and all OEM/variants of this model
are manufactured in accordance with EMC Directive 2014/30/EU (CE and UKCA), in compliance with the
following norm(s) or document(s):
Technical Regulations: EN55032:2015 (Emissions)
EN55032:2017 (Immunity)
and in accordance with the: Low Voltage Directive 2014/35/EU (CE and UKCA)
in compliance with the following norm(s) or document(s):
Technical Regulations: EN/IEC62368-1:2020 (Audio, Video & Communication Safety)
and in accordance with the Directive 2011/65/EU on the restricted use of certain Hazardous
Substances in Electrical and Electronic Equipment (RoHS2). We certify that the above-mentioned products are
deemed compliant according to the details given in the directive.
Signed:
Name: Alex Cooper
Position: Research and Development Manager
Date: May 2022
Introduction
The Ultrade U500DC is a high-end
dual channel power amplier with two
integral power supplies and single mains
connection, it is suitable for the most
discerning stereo Hi Fi, or can be used in
multiples for bi-amplied stereo or home
theatre applications.
Designed from the ground up for the most
demanding home listening environments
the U500DC eciently provides crystal
clear dynamic response with what feels
like endless power, grace, and ease.
The U500DC utilises two of our very
latest high speed push pull output stage
(“Sigma”) ampliers combined with
separate dual power supplies fed from
the mains via a single gold plated 10
Amp connection and a massive bespoke
shielded toroidal transformer that
provides total safety isolation.
The amplier provides dual binding posts
for each output allowing independent
wiring for tweeters and woofers plus dual
inputs; unbalanced RCA and balanced
XLR.

6
6 | Page
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings, install in accordance with the manufacturer’s instructions.
8) Do not install near any heat sources, such as radiators, heat registers, stoves or other apparatus that produce heat.
9) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point where they exit from the apparatus.
10) The mains circuit breaker shall remain readily accessible.
11) Only use attachments/accessories specified by the manufacturer.
12) Use only with the cart, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from a tip over.
13) Disconnect this apparatus during lightning storms or when unused for a long period of time.
14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as if the power-supply cord or plug is damaged,
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15) Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.
16) To completely disconnect this equipment from the AC mains, disconnect the power cord from the mains circuit breaker.
17) Where the amplifier is mounted in a rack and permanently connected to the mains, then the rack should be installed with a readily accessible connector or an ALL POLE
circuit breaker with 3mm breaking distances.
18) This unit is fitted with a C13 Mains IEC inlet. For safety reasons, THE EARTH LEAD SHOULD NOT BE DISCONNECTED IN ANY CIRCUMSTANCE.
INSTRUCTIONS DE SECURITE IMPORTANTES
1) Lisez ces instructions.
2) Conservez ces instructions.
3) Tenez compte de tous les avertissements.
4) Suivez toutes les instructions.
5) N'utilisez pas cet appareil près de l'eau.
6) Nettoyez uniquement avec un chiffon sec.
7) Ne pas bloquer les ouvertures de ventilation, installer conformément aux instructions du fabricant.
8) Ne pas installer à proximité de sources de chaleur telles que radiateurs, registres de chaleur, poêles ou autres appareils produisant de la chaleur.
9) Protégez le cordon d'alimentation contre les piétinements ou les pincements, en particulier au niveau des fiches, des prises de courant et du point de sortie de l'appareil.
10) Le disjoncteur secteur doit rester facilement accessible.
11) N'utilisez que les fixations/accessoires spécifiés par le fabricant.
12) Utiliser uniquement avec le chariot, le trépied, le support ou la table spécifié par le fabricant ou vendu avec l'appareil. Lorsqu'un chariot est utilisé, faire preuve de prudence
lors du déplacement de la combinaison chariot/appareil pour éviter les blessures en cas de renversement.
13) Débranchez cet appareil pendant les orages ou lorsqu'il n'est pas utilisé pendant une longue période.
14) Confiez tous les entretiens à un personnel de service qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque manière que ce soit, par exemple
si le cordon d'alimentation ou la fiche est endommagé, si du liquide a été renversé ou si des objets sont tombés dans l'appareil, si l'appareil a été exposé à la pluie ou à l'humidité,
ne fonctionner normalement ou a été échappé.
15) N'exposez pas cet équipement aux gouttes ou aux éclaboussures et assurez-vous qu'aucun objet rempli de liquide, tel que des vases, n'est placé sur l'équipement.
16) Pour déconnecter complètement cet équipement du secteur, débranchez le cordon d'alimentation du disjoncteur du secteur.
17) Lorsque l'amplificateur est monté dans un rack et connecté en permanence au secteur, le rack doit être installé avec un connecteur facilement accessible ou un disjoncteur
ALL POLE avec des distances de coupure de 3 mm.
18) Cet appareil est équipé d'une entrée secteur IEC C13. Pour des raisons de sécurité, LE FIL DE TERRE NE DOIT EN AUCUN CAS ÊTRE DÉBRANCHE.
CAUTION: RISK OF ELECTRIC SHOCK.
DO NOT OPEN
The lightning f
lash with arrowhead
symbol within an equilateral triangle is
intended to alert the user to the presence
if uninsulated dangerous voltagewithin
the products enclosure that may be of
sufficient magnitude to constitute a risk
of electric shock to persons.
The exclamation point within an
equilateral triangle is intended to alert
the user of important operating and
maintenance (servicing) instructions in
the literature accompanying the
appliance.
ATTENTION: RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
ATTENTION: Appareils de construction de CLASSE I doit être raccordé au réseau électrique via une prise de courant
reliée à la terre.
ATTENTION: Pour éviter toute blessure, cet appareil doit être solidement fixé à la torture, conformément aux
instructions d'installation.
Le symbole repr
é
sentant un éclair fl
é
ch
é
dans un tr iangle équilatéral a pour but
dalerter lutilisateur de la présence
dune tension dangeruesenon isolée à
lintérieur du boitier, pouvant être dune
force suffisante pour constituer un risqué
délectrocution.
Le point dexclamation dans un triangle
équilatéral a pour but dalerter
luntilisateur de la présence
dinstructions importantes concernant le
fonctionnement et la maintenance, dans
la documentation qui accompagne
lappariel.
Safety

7
Installing
Installing Your Amplier: Electrical
Considerations
The amplier has been manufactured
to comply with your local power supply
requirements, but before connecting the
unit to the supply, ensure that the voltage
(printed on the rear panel label) is correct and
corresponds with that of the local supply.
The amplier is tted with a 115/230V
tapped transformer and is internally set (from
factory) according to customer requirements.
Make sure power outlets conform to the
power requirements listed on the back of
the unit. Damage caused by connecting to
improper AC voltage is not covered by the
warranty.
Installing Your Amplier: Mechanical
Considerations
The U500DC should be used horizontally and
placed on a stable surface or other mounting
that is commensurate with the weight of the
amplier.
The mounting must also allow adequate
ventilation of the external surfaces and air
ow through the ventilation holes on the
underside and at the rear of the amplier.
Do not place in a closed cabinet or over
radiators or other heat sources.
The U500DC should not be placed close to
other equipment that is sensitive to magnetic
elds and performance may be degraded if it
is used in close proximity to other equipment
that radiates high radio frequency elds.
!
SAFETY WARNING
Where a MAINS plug or appliance coupler is used
as the disconnect device, it should remain readily
operable. Where the amplier is mounted in a rack
and permanently connected to the mains, then the
rack should be installed with a readily accessible
connector or an ALL POLE circuit breaker with 3mm
breaking distances. This unit is powered using a
3-wire power cord (C13 IEC). For safety reasons, THE
EARTH LEAD SHOULD NOT BE DISCONNECTED IN
ANY CIRCUMSTANCE. If ground loops are encountered
consult the section on XLR connections on page 9.
The wiring colours are:
230v areas 115v areas
Earth Green/Yellow Earth Green
Neutral Blue Neutral White
Live Brown Live Black
DO NOT USE THE UNIT IF THE ELECTRICAL
POWER CORD IS FRAYED OR BROKEN.
The power supply cord should be routed so that they
are not likely to be walked on or pinched by items
placed upon or against them, paying particular attention
to cords and plugs and the point where they exit from
the appliance.
ALWAYS OPERATE THE UNIT WITH THE AC GROUND
WIRE CONNECTED TO THE ELECTRICAL SYSTEM
GROUND.
Precautions should be taken so that the means of
grounding of a piece of equipment is not defeated.
DO NOT REMOVE THE COVER.
Removing the cover will expose you to potentially
dangerous voltages. There are no user serviceable
parts inside.

8
Basic Connection & Set Up / AC Mains Power
Basic Connections & Set-up Explained
The U500DC receives power from the mains
via an IEC C13 AC connection and can also
be connected or disconnected from the
mains by a rocker switch on the rear panel.
Position 1 makes the connection and 0
breaks the connection. When mains power is
connected the amplier is ready to be used
and it may be put into standby or powered up
fully by pressing the standby switch on the
front panel.
The amplier should be powered off fully
when making any other connections to the
rest of the audio system.
Audio input connections can be made at the
rear of the amplier via a pair of XLR’s and
a pair of RCA connectors that will interface
directly to most other domestic audio
equipment. These are both active (on) at all
times, so it is possible to set up two alternate
sources (or even mix them should there be a
circumstance when that is desirable).
Speaker connections are also made on the
rear of the amplier and provided on 4 pairs
of binding posts to allow simple or more
advanced wiring options.
Mini Jacks are provided on the rear panel
that allow DC signals (5-12v) to remotely
control the standby/power up status of the
amplier. Two are provided to allow daisy
chaining with other parts of the system. They
are “edge triggered” which allows the remote
control to override the front panel switch or
vice versa (whichever is used last).
Connection Setup Tips
All audio system equipment should be sited
reasonably close together if possible so that
wire lengths can be kept quite short. This
approach inherently reduces ground loop
(hum) noise (by reducing the loop area) and
other interference that can be induced in the
cables although it’s not the only way***. All
equipment should also be powered from the
same mains source if possible and certainly
from the same mains phase (which is normal
in domestic house wiring).
AC Mains Power
The Ultrade U500DC is set up to operate
from either 230V nominal or 115V nominal,
50 - 60Hz AC mains. The mains cable must
contain a Safety Earth conductor and the
connection to earth must not be defeated or
tampered with in any way.
In theory the mains Live and Neutral power
conductors are inherently current balanced
and therefore no current ows in the earth
conductors; however stray capacitance, other
coupling and mostly lter components used
for compliance to EMC standards does cause
a small current to ow in most mains earth
systems. This is the source of the ground
loop hum that may need to be addressed
when wiring an audio system.

9
Remote Standby Connectors
Mini Jack cables are used for remote power
up control and use the tip and outer ring for
connectivity. A positive going edge will take
the amplier out of standby and a negative
going edge will put it back into standby. The
system will work with 5V to 12V signals.
XLR Connectors
As a simple rule of thumb input connections
are best made balanced on the U500DC
XLR’s because balanced systems inherently
reject ground loop noise and, in the unlikely
event that hum does prove to be a problem,
it is also possible to break the ground
connection on Pin 1 of the XLR at one end
which usually resolves the problem simply
and does not compromise safety in any way.
Signals of 2.2V rms will put the amplier
close to full power. The standby switch will
ash red if this is exceeded.
RCA Connectors
Some audio system equipment may be
battery powered or double isolated (with no
earth wire) and typically these will provide
RCA outputs that will operate perfectly well
(without hum) on the U500DC RCA inputs,
which also provide a low impedance ground
for the cable shield. Signals of 2.2V rms
will put the amplier close to full power.
The standby switch will ash red if this is
exceeded.
The RCA inputs can also be used, if preferred,
with other grounded equipment, but the use
of short cables and common mains source
becomes critical in order to remove/reduce
ground loops. Sometimes additional ground
bonding cables may be necessary to supress
ground loops.
***Another trick, that is counter intuitive but
can be useful, is to run the audio signals
alongside the mains cables. If the mains is
all supplied from a single source this can be
thought of as a “star point”. If all audio cables
run alongside the mains cables and pass
close or over the star point, then the ground
loop area is massively reduced eliminating
the hum.
Mixed XLR and RCA Connectors
Unbalanced RCA sources can be connected
to the balanced XLR inputs and benet from
the hum rejecting properties of balanced
systems, providing two conductor cables
with an overall shield are used. For oating
sources (battery powered or double isolated
equipment) the Pin 1 shield conductor
should be connected to the signal reference
conductor at the RCA end. For grounded
sources this connection may not need to be
made (some experimentation may be needed
to minimise hum from potential ground
loops).
Balanced XLR sources can sometimes be
connected to RCA inputs, but this depends
on the nature of the driving circuit. If the
manufacturer of the balanced source
states that the signals are oating, or that
unbalanced operation is possible, then the
cable can be wired exactly as above, and
again the pin 1 connection can be optionally
connected to the signal reference conductor
at the RCA end.

10
Binding Posts
Two pairs of binding posts are provided
for connection to loudspeakers. This
allows separate conductors for Tweeter
and Woofer. The Red binding posts are
positive (+) voltage, and the Black binding
posts are negative (-) voltage; they should
be connected to the red and black or +
and - connectors on the loudspeaker. For
convenience the binding posts accept
4mm “banana” connections, but bare wire
termination is recommended for permanent
installations when the binding post terminal
can be screwed down into place directly onto
the cable conductors.
Cable Types Required
The IEC C13 Main’s connector and cable
should be high quality 10A rated with
three core’s including a ground connection
which must not be disconnected under any
circumstances.
Mini Jack cables work with 3 pin or 2 pin
style connectors. Cables should be shielded
but no other special requirements are
needed.
All RCA-to-RCA connections should use high
quality cable with a single central conductor
for the signal and a braided outer conductor
that behaves as a ground reference and as a
shield against radio interference.
All XLR-to-XLR connections should use high
quality cable with a dual, twisted central
conductors for the signals (or signal and
ground reference) and a braided outer
conductor that behaves as a shield against
radio interference.
All RCA-to-XLR connections should use
high quality cable with a dual, twisted
central conductors for the signal and
ground reference plus a braided outer
conductor that behaves as a shield against
radio interference. The shield needs to be
connected at the XLR end and may optionally
be connected to the ground reference
conductor at the RCA end.
All Binding Post connections should use
high quality speaker cables with paired
conductors that are capable of delivering
high currents (10A or more) and maintaining
low impedance over the cable run.
Basic Connection & Set Up / AC Mains Power

11
11 | Page

12
The Ultrade U500DC has no volume controls
or any other components that may degrade
the sound quality of the signals it receives.
This even extends to the internal joining of
the various amplier sections which are
all DC coupled, eliminating the use of any
capacitors in the signal path. The resulting
soundscape is true and clear with ample
power for any domestic speaker systems.
However, for some, the desire for some of the
colouration traditionally associated with older
class AB ampliers may still be there, and a
switch is provided on the rear of the amplier
to change the Timbre to that older style. It’s a
matter of personal preference and we like to
think we can accommodate both tastes with
this switch.
Internal Gain Calibration Control
Internal Gain Calibration Control
The U500DC will happily deliver 500W per
channel into 4R load but this reduces to
250W into 8R. For those wanting every
ounce of power they can get at 8R it is
possible to override the output clipping
protection and increase the gain by 3dB so
that the amplier will deliver 300W into 8R.
It is not recommended to use this setting
for connection to 4R speakers. For more
information on how to carry out this change
please contact us.
Other Controls
Internal Mains Calibration
It is possible to congure the U500DC for use
with nominal 230V or nominal 115V mains
and this should already have been done prior
to shipping to you. These adjustments should
only be carried out by qualied personnel
and information will only be provided to
accredited dealers and service engineers.

13
Operation and Maintenance
Apart from switching on and off there is no
need for any further operational instructions.
However, some consideration should be
given to other factors.
Do not operate the amplier in wet
conditions or spill liquid into it, as this may
cause damage or endanger life.
It is often considered good practice to use
an amplier with greater power capability
compared to the loudspeakers because that
allows for plenty of headroom, but if that’s
the case then obviously sensible volume
levels need to be used for both protection of
your hearing and of the loudspeakers.
Cleaning should be done using a light duster
or in more severe cases of dirt build up use
a damp (not wet) cloth while the system is
powered down.
The U500DC self protects against all
“normal” fault conditions (short circuit open
circuit etc.) but this does not extend to
connection of the wrong mains voltage or to
connection mains voltages anywhere other
than to the IEC mains inlet.
WARRANTY INFORMATION
All ULTRAFIDE products are guaranteed for a period of
FIVE (5) years from date of manufacture against faulty
materials or workmanship under normal conditions of
use.
All units under warranty claim should be returned to the
seller (carriage-prepaid) with a clear fault description.
Units repaired under warranty will be returned to the
seller from MC² Audio / ULTRAFIDE prepaid.
MC² Audio / ULTRAFIDE will only support warranty
repairs if the unit in question has not been subjected to:
• Unauthorised repair work or alteration
• Damage including shipping accidents
• Any use not covered in the operator’s manual
• Exposure to moisture or harmful weather conditions
• Normal wear and tear.
Units on which the serial number has been removed
or defaced will not be eligible for warranty service.
MC² Audio / ULTRAFIDE’s responsibility is limited
to the product itself and the company accepts no
responsibility for any incidental or consequential
damages, including any loss due to cancellation of any
events, or rent of replacement equipment or costs due
to third party’s or customer’s loss of prot, or any other
indirect cost or losses however incurred.

14
Audio Channels (quantity) 2 2 RCA (Single Ended)
Audio Inputs 4 2 XLR (Balanced)
NOTE: Both input types are always active; thus 2 sources can be summed if desired
Input Impedance 10k RCA and XLR
Input RFI Filtering Capacitance 550pF RCA and XLR
Audio Outputs 4 pairs Binding Post
NOTE: Double channel connectors allow separate Tweeter and Woofer cables if desired
Output Impedance 25mR
Maximum Voltage 70V
Maximum Current 30A (pulsed testing)
Voltage Gain 26dB (standard factory setting) 29dB
Current Gain 50,000 94dB
Sensitivity 2.2 Volts
Dynamic Range 115dB Un-Weighted 22-22kHz
Inter-stage Coupling DC Coupled
Frequency Response 5 to 20kHz +-0.3dB
Distortion 0.003% at 5W 0.008% at 200W
Rise/Fall Time 10uS
Stability Unconditional
RMS Power into 4R 500W 600W at high gain setting
RMS Power into 6R 333W 400W at high gain setting
RMS Power into 8R 250W 300W at high gain setting
RMS Power into 12R 166W 200W at high gain setting
NOTE: Amplier is stable into 2 ohm loads but with no increased power.**
Power Supply Connector 10A Furutech C13 IEC
Fuse 10A
Nominal Power Supply Voltage 230Vac (50Hz) or 120Vac (60Hz)
Power Voltage Selector Internal
Power Isolation Switch On Rear Panel
Standby Switch On Front Panel
Remote Standby Connector on Rear Panel
Power Consumption operational 200W average 1,000W max
Power Consumption Idle 15W
Power Consumption Standby 1W
Current Consumption 230v – 1A nominal (5A max) 120v – 2A nominal (10A
max)
Power Indicator Green for Out of Standby
Fault Indicator Red Led illuminates if clipping or protection
is active
Product size / weight (packed) 590(L) x 405(W) x 152(H)mm 14.65kg (GROSS)
Product size / weight (unpacked) 382(L) x 325(W) x 97(H)mm 13.05kg (NET)
Technical Specications

15
The U500DC has 5 different connection types on the rear panel:
C13 IEC AC Mains connection (x1) XLR balanced signal inputs (Female x2) RCA unbalanced signal Inputs (Female x2)
Binding post loudspeaker outputs (x4 pairs - 2 per channel for bi-wiring) Remote Trigger (x2 3.5mm Jack plugs wired in parallel)
Quick Start Guide
E
B
D
A
B
C C
!
PLEASE NOTE:
This quick start guide is an overview to get you up and running quickly and easily. It contains basic information required to
operate the U500DC.
It is not a substitute for reading the manual, that contains lots of important information with regards to safety and setup
requirements. Please take time to read the complete manual and familiarise yourself with its content. For any questions
please contact us, we would love to hear from you.
Positioning
Please ensure there is sufcient ventilation around the U500DC at all
times.
DO NOT PLACE THE UNIT IN ENCLOSED SPACES OR COVER ITS
VENTILATION HOLES AT ANY TIME.
Power
An appropriate C13 IEC mains connector must be tted to the unit to suit
the available mains supply voltage and according to the requirements as
stipulated on the chassis rear voltage label. The correct IEC is supplied in
the box with the unit. This unit must be earthed.
Use the mains rocker switch, on the rear of the unit, to turn the unit on/
off. Use the front standby switch to put the unit out of, or into standby
mode. Please note: There is a short delay upon using the standby switch.
The U500DC can also be put in and out of standby with DC signals on the
remote trigger connectors. The amplier will accept voltages from 5-12v.
Looping this connection out to other U500DC’s is also possible for power
sequencing of other units in the system.
Timbre
For those wanting a more vintage type of sound delivery a “TIMBRE”
switch on the rear changes the input circuits from “PURE” to “VINTAGE” to
operate more like traditional class AB ampliers.
Connections
The U500DC is equipped with binding posts that can accept bare wires,
banana plugs, or spade connections. There are 2 pairs of connectors
for each output channel to allow bi-wiring (separate tweeter/woofer
connections if desired). The Red binding posts are positive (+) voltage,
and the Black binding posts are negative (-) voltage; they should be
connected to the red and black or + and - connectors on the loudspeaker.
PLEASE NOTE: The minimum nominal impedance of loudspeakers
that can be connected to the U500DC is 4 ohms. Driving loads with a
nominal impedance below 4 ohms is not recommended as it may cause
overheating but driving speakers with 2 ohm impedance dips that only
occur at specic frequencies will not cause any problems. The U500DC
remains stable into any load including a dead short, however, shutdown
protection will occur if the output current exceeds 35A, which is highly
likely at impedances below 2 ohms.
The U500DC can accept balanced XLR (recommended) or unbalanced
RCA input signals. For reference when using balanced XLR signal cables
the pin conguration is as follows: Pin 1: Ground | Pin 2: Signal Positive
+ | Pin 3: Signal Negative -
Always make sure that the U500DC is powered off from the AC mains
supply when connecting/disconnecting any loudspeaker or signal cables.
Always make sure that partnering equipment (preamplier/DAC etc)
are also set to minimum volume before any powering up or down. The
U500DC does have protection for any startup noises, but it’s always good
practice to set the volume to minimum on partnering equipment upon
power sequencing.
A B C
DE

16
XTA Electronics Ltd Trading as MC² Audio & Ultrade
Units 6-7 Kingsgate
Heathpark Industrial Estate, Honiton, Devon
United Kingdom. EX14 1YG
Tel: +44(0)1404 44633
Email: hello@ultradeaudio.co.uk
www.ultradeaudio.co.uk
This manual suits for next models
1
Table of contents
Other XTA Amplifier manuals
Popular Amplifier manuals by other brands

Ahuja
Ahuja TZA-4000 DP Operation manual

Biamp
Biamp AMP-450BP Installation & operation guide

Stanford Research Systems
Stanford Research Systems SR446 Operation and service manual

Crown
Crown ce 4000 Reference manual

Audio Note
Audio Note CONQUEST Low Gain Owner's Information

Mark Levinson
Mark Levinson 536 manual