xtemp UXB8401-PG280 User manual

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
BUSINESS CENTER: ROOMS 501-508, 5/F, NEW XUHUI BUSINESS CENTER, NO 33 RIHUI LIUCUN,
XIETU ROAD, XUHUI DISTRICT, SHANGHAI, 200032, CHINA
TEL.: +86 21 6443 1641 FAX: +86 21 6403 9005
XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
ADD: ROOMS 909-11, NO 2777 ZHOUHAI ROAD
PUDONG NEW DISTRICT, SHANGHAI, 200137, CHINA
TEL.: +86 40004 XTEMP
Operating Instructions
Tall Plant Growth Chambers
Arabidopsis Growth Chambers
Climatic Chambers/Germinators
UXP8401-PG280/PG480/PG880
UXP8401-AR280/AR480/AR880
UXP8401-CC280/CC480/CC880

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/1/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Contents C
Preface.............................................................................................. 3
Chapter 1 Safety Warning and Instructions................................... 6
1.1 Normal operating environment ............................................................................................................ 6
1.2 Safety warning ........................................................................................................................................... 6
1.3 Caution ........................................................................................................................................................ 7
Chapter 2 Installing and Operating ............................................. 10
2.1 Installing ..................................................................................................................................................... 10
2.1.1 Unpacking ............................................................................................................................................. 10
2.1.2 Installing .................................................................................................................................................. 12
2.2 Descriptions............................................................................................................................................... 14
2.2.1 Front view............................................................................................................................................... 14
2.2.2 Back view............................................................................................................................................... 15
2.2.3 Humidifier ............................................................................................................................................... 16
2.2.4 Portable temperature/humidity aspirator..................................................................................... 17
Chapter 3 Controller Descriptions and Operation...................... 19
3.1 Power up ................................................................................................................................................... 19
3.2 HOME Screen ........................................................................................................................................... 19
3.3 Start the equipment operation ........................................................................................................... 22
3.4 Constant operation................................................................................................................................ 22
3.5 Start Now ................................................................................................................................................... 23
3.6 Termination of equipment operation................................................................................................ 24
3.7 Details for immediate Constant.......................................................................................................... 25
3.8 Display in curve or table ....................................................................................................................... 25
3.9 Schedule a constant operation.......................................................................................................... 28
3.10 Edit a Program ....................................................................................................................................... 29
3.11 Start a program operation now........................................................................................................ 34
3.12 Schedule a program operation........................................................................................................ 36
3.13 Clear warning message...................................................................................................................... 37
3.14 USER menu .............................................................................................................................................. 38
3.15 T/H MODE ................................................................................................................................................ 40
3.16 Radiation set .......................................................................................................................................... 41
3.17 Language ............................................................................................................................................... 42
3.18 FACTORY ................................................................................................................................................. 43

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/2/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Contents C
Chapter 4 Maintenance................................................................ 44
4.1 Regular maintenance ........................................................................................................................... 44
4.2 Checking and replacing the fuse ...................................................................................................... 44
4.3 Inspection of power supply for piezoelectric elements ............................................................... 45
4.4 Installation and replacement of the portable temperature / humidifier aspirator.............. 46
4.5Checking and cleaning of the condenser .................................................................................... 47
4.6Checking and charging of refrigerant ............................................................................................ 47
Chapter 5 Equipment Overview and Specifications .................. 50
5.1 Equipment overview .............................................................................................................................. 50
5.2 Specifications........................................................................................................................................... 51

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/3/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
P
r
eface P
Preface
In order to make the equipment fully functional and ensure safety of the operator, the equipment,
property and specimen, read this manual carefully and completely. When you have any
question that cannot be explained by this manual, consult your local distributors or supporting
technicians. It is our pleasure to provide service for you.
General safety notes
Hazard exists if the equipment is used to heat, cool and condition specimen containing or
treated with toxic chemicals or hazardous microorganisms; and hazard arises if the specimen
within the equipment should be treated at periodic or aperiodic intervals with toxic
chemicals or hazardous microorganisms; and hazard develops if specimen liberates
hazardous substance under refrigerated and heating conditions with or without additive
humidity and light radiation, where hazardous substance may be exhausted in the air by
exhaust opening or operating of the door or, drained through liquid connections or drain
device to cause risks.
There exist general hazards related to the application of electrical energy and machine. It is not
possible to cover all possibilities; they remain largely within the responsibility and the
judgment of the operator!
The equipment must only be used as intended and described in these Operating Instructions. This
includes operation by suitably trained qualified personnel.
The maximum temperature deviation both in normal condition and in electro-magnetic
interference field according to IEC 61326-1 is ±0.5 °C.
Classes of the EMC standard IEC 61326-1
Class A: Equipment for operation only on networks without connected domestic areas;
Class B: Equipment for operation on networks with connected domestic areas.
Valid for Europe
The equipment is designed in accordance with EMC requirements of EN 61326-1 Class B. Class B
equipment is suitable for operation on networks with connected domestic areas.
Valid for USA
Instructions for Class A digital devices as follows:
“This equipment has been tested and found to comply with the limits for Class A digital device,
pursuant to Part 15 of the FCC (Federal Communication Commission) Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/4/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
P
r
eface P
can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.”
“This device complies with Part 15 of the FCC (Federal Communication Commission) Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.”
Valid for Canada
“This Class A digital apparatus complies with Canadian ICES-003” (ICES=Interference Causing
Equipment Standards).
«Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada».
Important symbols
For your safety, pay attention to these important symbols as follows, during moving, installing
operating and maintenance. The equipment is designed for safe operation because of your
attention!
Warning, possibility of electric shock!
Inappropriate operation may cause hazard of electric shock and result in serious personal injury
or death!
Symbols on the equipment
Caution, Class A equipment must not be operated on power networks with connected
domestic areas!
Caution, important note, and always refer to Operating Instructions (this document) for detailed
information!
The equipment must be operated by well-trained qualified personnel only!
Wrong operation may cause personal injury, damage and/or mal-function of the equipment!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/5/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
P
r
eface P
Warranty
Requirements for warranty
Xtemp Environments warrants the operational safety and functions of the equipment only under
the conditions that:
the equipment is operated and serviced exclusively in accordance with its intended
purpose and as described in these operating instructions;
the equipment is not modified;
only original spare parts and accessories that have been approved by Xtemp
Environments are used;
inspections and maintenance are performed at the specified intervals.
The warranty is valid from the date of delivery to the operator.
Observe operating instructions!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/6/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 1 Safety Warning and Instructions 1
Chapter 1 Safety Warning and Instructions
1.1 Normal operating environment
The equipment is designed for safe operation under ambient conditions as follows:
indoor use;
altitude up to 2,000 m;
temperature 5 °C to 40 °C;
maximum relative humidity 80 % for temperatures up to 31 °C decreasing linearly to 50 %
relative humidity at 40 °C;
mains supply voltage fluctuations up to ±10 % of the nominal voltage;
transient overvoltage up to the levels of overvoltage category II;
temporary overvoltages occurring on the mains supply;
Pollution degree 2 or less of the intended environment;
Wet location
Excessive high or low temperature and/or humidity will significantly degrade electric safety of
the equipment!
1.2 Safety warning
Not applicable for heating, cooling, conditioning or storage of specimen which is intrinsically
explosive, flammable or toxic or, which may liberate hazardous substances under normal
operating temperature conditions! Caution: Explosive or flammable hazards!
The dielectric strength of the equipment may be degraded if after transport or storage in
humid conditions. The equipment shall be powered as for normal use and conditioned at its
maximum operating temperature or 45°C, whichever is smaller, for at least 1h before
commissioned for normal use. Warning, hazard of electric shock during the dry-out!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/7/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 1 Safety Warning and Instructions 1
1.3 Caution
Pull the operating temperature of the equipment as close as possible to the ambient before
attempting to open the door or shut down the equipment.
The minimum distance away from the back of the equipment to the wall, furniture or other
installations shall be 300mm!
Reduce the frequency of door operating and keep the door opening as short as possible! It
takes time for the equipment to recover the Temperature and temperature distribution! The
temperature difference may result in condensing and dripping of the specimen!
Caution: Risk of biological and chemical hazards!
When hazardous substance may be exhausted in the air by exhaust opening or operating of
the door or, drained through liquid connections or drain device for condensate:
a) hazard exists if the equipment is used to heat, cool and condition specimen containing or
treated with toxic chemicals or hazardous microorganisms;
b) hazard arises if the specimen within the equipment should be treated at periodic or
aperiodic intervals, with toxic chemicals or hazardous microorganisms;
c) hazard develops if specimen liberates hazardous substance under refrigerated and
heating conditions with or without additive humidity.
Caution: Hazard of strong optical radiation!
Lamp canopies incorporated either at both sides, or within the cabinets generate strong visual
radiation which could cause a hazard. Use special care when trying to get access to the cabinet
interior:
a) Use glass ware or equivalent PPE as appropriate;
b) Check functionality of dimming capability of the lamp canopies once door opened, and
confirm that the light intensity within safe limit;
c) Access to the side lamp canopies only the well-trained personnel and with appropriate
PPE against optical radiation, electric shock and burn hazard;
d) Never disable the dimming sensor for safe light intensity.

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/8/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 1 Safety Warning and Instructions 1
Caution, Risk of burn hazard!
Do not touch or approach parts or area with high temperature, for example, surface of the
lamp tube or metal enclosure!
The swivel casters shall be locked once the equipment is seated and leveled so that it doesn’t
move or travel during operation which otherwise may result in hazard from imbalance or side
skid!
The humidifier shall be connected to purified water mains with stable pressure of 1 bar ± 0.2
bar. The conductivity of the water shall be no more than 10µs/cm.
Tape water, distilled water or purified water of general process with conductive ions (TDS in
general), including contaminant of bacteria, microorganisms and organic substances will
degrade the service life of the piezoelectric element of the humidifier.
Unstable supply pressure will affect water level of the humidifier, thus the hysteresis for mist
generating and humidifier efficiency. The piezoelectric element may be damaged if low water
level triggered from time to time.
Equipped with a refrigerant condensing unit, never tilt the equipment beyond 30 degrees
during movement or transport! In case the equipment arrives upside down, rollover or tilted
conditions, the dielectric strength of the equipment may be degraded. The equipment must
be kept standstill for at least 24h before commissioned for normal use!
The inlets of fresh air and outlets of exhausting air for the condensing unit shall be kept clear of
any obstacles!
Keep the equipment away from hot-air emitting source, direct sunshine, strong magnetic field
and electric sparks!
Neither contamination of high concentration dust or corrosive gas, nor strong airflow surrounds!
Voltage, frequency and current for power supply must meet the requirements as designated
on the nameplate! Use power socket matching the power plug of the equipment. Hot
line(L)and neutral line(N)for single phase equipment must not be reversed!
Socket for power supply must be equipped with protective ground (PE) to prevent against
hazard of possible electric shock!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/9/ 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 1 Safety Warning and Instructions 1
Connect the power from behind the equipment. Plug in and remove the cable by directly
holding the plug. No dragging of cable in any part. Protect the cable from being damaged by
contacting with the hot surface of the equipment or mouse etc!
Keep clear of inlets and outlets of back plenum for the circulating hot air. Excessive hoarding of
specimen or blockage of the air circulating may cause frost accumulation on surface of the
evaporator, localized temperature distribution and degraded performance!
Install a flexible tubing to the extraction system, if the operating of the equipment could lead to
liberation of hazardous air or gas mixture, for example the application of chemicals to treat
specimen under growth!
Do not disassemble or exchange assembly parts and electric circuits by unauthorized
personnel! Hazard of possible electric shock! In case of repairing, contact authorized local
distributor or maintenance engineer.
Always remove the mains plug from the socket before cleaning, moving, maintenance or
repairing!
If you come in touch with the PCB's of the equipment please take care that you follow the
electro-static discharge (ESD) guidelines and use ESD protection kit to prevent any damage on
the electronic components.
Perform regular check or maintenance for the following at designated internals:
Clean the cabinet interior weekly or where necessary!
Decontaminate cabinet interior and wire shovels on case-by-case bases if necessary!
Check the air tightness of the door seal at six months internals!
Check and clean the condenser at six months internals or where necessary!
Check cabinet Klixon at six months intervals or more frequently when necessary!
Check low level cut-out switch LLCO for the humidifier at three months intervals or as
necessary!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/10 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
Chapter 2 Installing and Operating
2.1 Installing
2.1.1 Unpacking
Unpack the equipment and sort the accessories respectively and carefully. The packing carton,
pallet, packing buffering stuffs etc., are designed for one shipment only. For future shipment,
prepare the packing materials as well as the way of packing as received.
Check the equipment and accessories for potential transport damages. If there is any damage
visible on the equipment, a claim must be filled in writing with the freight forwarder; a
notification to the freight forwarder is obligatory so that the shipment can be examined.
Inform your local distributor or supplier for any missing accessories and servicing or repairing.
Accessories lists (UXP8401-PG)
Part Number Qty Descriptions Remarks
DSEO0711-2 1
Operating Instructions This document
ERSG0202 1
Fuse (250V~/15A), D5L20 Breaking capacity:1500A
BJEW1802 1 Perforated shelves,280 PG280
BJEW1803 1 Perforated shelves,480 PG480
BJEW1804 1 Perforated shelves,880 PG880
BJKA0332 4 Shelf clips
BJEZ1801 1 PG Lamp canopy,PG280 PG280
BJEZ1802 1
PG Lamp canopy,PG480 PG480
BJEZ1803 1
PG Lamp canopy,PG880 PG880
BJEW1805 2
Canopy supports,PG/AR280 PG280
BJEW1806 2
Canopy supports,PG/AR480 PG480
BJEW1807 2
Canopy supports,PG/AR880 PG880
BJEF1801 1 PG Floor cassette,PG280 PG280
BJEZ1821 1
PG Floor cassette,PG480 PG480
BJEZ1831 1
PG Floor cassette,PG880 PG880
BCOA4201 1 Temperature and humidity aspirator
Accessories lists (UXP8401-CC)
Part Number Qty Descriptions Remarks
DSEO0711-2 1
Operating Instructions This document
ERSG0202 1
Fuse (250V~/15A), D5L20 Breaking capacity:1500A

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/11 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
BJEW1802 3 Perforated shelves,280 CC280
BJEW1803 4 Perforated shelves,480 CC480
BJEW1804 4 Perforated shelves,880 CC880
BJKA0332 12 Shelf clips CC280
BJKA0332 14 Shelf clips CC480、CC880
BCOA4201 1 Temperature and humidity aspirator
Accessories lists(UXP8401-AR)
Part Number Qty Descriptions Remarks
DSEO0711-2 1 Operating Instructions This document
ERSG0202 1
Fuse (250V~/15A), D5L20 Breaking capacity:1500A
BJEW1802 2
Perforated shelves,280 AR280
BJEW1803 2
Perforated shelves,480 AR480
BJEW1804 2
Perforated shelves,880 AR880
BJKA0332 8 Shelf clips
BJEZ1801 2
AR Lamp canopy,AR280 AR280
BJEZ1802 2 AR Lamp canopy,AR480 AR480
BJEZ1803 2 AR Lamp canopy,AR880 AR880
BJEW1805 4 Canopy supports,PG/AR280 AR280
BJEW1806 4 Canopy supports,PG/AR480 AR480
BJEW1807 4 Canopy supports,PG/AR880 AR880
BCOA4201 1 Temperature and humidity aspirator
Accessories lists (UXP8401-GE)
Part Number Qty Descriptions Remarks
DSEO0711-2 1
Operating Instructions This document
ERSG0202 1
Fuse (250V~/15A), D5L20 Breaking capacity:1500A
BJEW1811 4 Seed tray,GE280 GE280
BJEW1812 5 Seed tray,GE480 GE480
BJEW1813 5 Seed tray,GE880 GE880
BJEW1814 8
Seed tray supports,GE280 GE280
BJEW1815 10
Seed tray supports,GE480 GE480
BJEW1816 10
Seed tray supports,GE880 GE880
BCOA4201 1 Temperature and humidity aspirator

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/12 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
Do not disassemble or exchange assembly parts and electric circuits by unauthorized
personnel! Hazard of possible electric shock! In case of repairing, contact your local distributors
or supporting technicians.
In case of damaged shipment and dent, deformation or distortion of the enclosure, contact
authorized local distributor or personnel.
2.1.2 Installing
Install the equipment on a rigid, nonflammable surface and well-ventilated place. If the
equipment is installed on an unstable surface or floor, abnormal noise may be generated.
Keep enough space between wall and back of the equipment for better ventilation.
The voltage, frequency and current of the power supply must be rated at least the same as those
designated on the name plate of the equipment. The switch board is recommended to be
on the back right side of the equipment and equipped with outlet matching the power plug
of the equipment with protective ground (PE).
For possible wet location conditions, where cycle of evaporating and condensing, overflowing or
spillage may occur and for protection against hazard of possible electric shock, use power
socket with appropriate IP protection and additional residual current circuit breaker (RCD)
with rated breaking capacity!
Power socket, switchboard with circuit breaker or residual current circuit breaker for the
equipment shall be located closest to the equipment with good clearance for easy access,
so that immediate interruption is possible under emergent circumstance.
The humidifier shall be connected to a water mains of stable pressure 1 bar±0.2 bar, and a
pressure regulator shall be used where necessary. When tap water is used, a water softener or
purifier of 10 μs/cm or less is mandatory. The flexible tubing or hose between water source
and liquid connection of the equipment shall be fixed and protected from mechanical,
thermal and chemical stresses for performance and safety. For specifications and
requirements for a pump booster, pressure regulator, water softener and purifier, consult
Xtemp or local authorized distributor.
The minimum distance away from the ventilating holes at the back of the equipment to the
wall, furniture or other installations shall be 300mm! The inlets of fresh air and outlets of
exhausting air at the back of the equipment shall be kept clear of any obstacles.
Keep the equipment away from hot-air emitting source, direct sunshine, strong magnetic field
and electric sparks!
Neither contamination of high concentration dust or corrosive gas, nor strong airflow surrounds!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/13 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
Voltage, frequency and current for power supply must meet the requirements as designated
on the nameplate! Use power socket matching the power plug of the equipment. Hot line
(L)and neutral line(N)for single phase equipment must not be reversed!
The equipment shall be secured by locking the swivel casters or adjusting of the levelers once it
is in place and before being commissioned, to mitigate noise, protect it from accidental
movement and fall down from imbalance, and ease draining.
The flexible tubing or hose between water source and liquid connection of the equipment shall
be fixed and protected from mechanical, thermal and chemical stresses for performance and
safety
Keep water supply pressure stable and constant.
Socket for power supply must be equipped with protective ground (PE) to prevent against
hazard of possible electric shock.
Install a flexible tubing to the extraction system, if the operating of the equipment could lead
to liberation of hazardous air or gas mixture, for example the application of chemicals to treat
specimen under growth!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/14 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
2.2 Descriptions
2.2.1 Front view
Fig 1 Front view
01 Power SW with lock
02 HMI touch screen
13 Lamp canopy(CC/GE)
14 Perforated shelves
17 Interior glass
18 Front door
19 The levelers
34 Ventilator
35 Glass door alarm switch
42 Temperature and humidity aspirator
58 Sockets for PAR and Lux transmitter
71 Ultrasonic humidifier
72 USB socket (Optional)
123 Drip pan
145 Cable socket for portable T/H aspirator
150 Connection for air sampling tube
226 Proximity switch for dimming of lamp canopy
The first time powering up after repairing or standstill for long period, or at designated intervals
under normal use, check the functionality of the following parts or components:
Check the air tightness of the door seal at six months internals!
Check and clean the condenser at six months internals or where necessary!
Clean the cabinet interior weekly or where necessary!
Decontaminate cabinet interior and wire shovels on case-by-case bases if necessary!
Keep clear of inlets and outlets of back plenum for the circulating air. Excessive hoarding of
specimen or blockage of the air circulating may cause frost accumulation on surface of the
evaporator, localized temperature distribution and degraded performance!

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/15 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
2.2.2 Back view
Fig 2 Back view
04 Exhausting-air outlets
06 Hatch/Access port
22 Power cable
25 Fixed casters
30 Connection for exhaust opening
31 Condensate outlet
57 Water inlet for humidifier
70 Humidifier control module
213 Ethernet interface (optional)
Perform regular check or maintenance for the following at designated internals:
Clean the cabinet interior weekly or where necessary!
Decontaminate cabinet interior and wire shovels on case-by-case bases if necessary!
Check the air tightness of the door gasket at three months internals or the first time application
after storage of service!
Check and clean the condenser at six months internals or where necessary!
Caution: Hazard of strong optical radiation!
Lamp canopies incorporated either at both sides, or within the cabinets generate strong visual
radiation which could cause a hazard. Use special care when trying to get access to the cabinet
interior:
a) Use glass ware or equivalent PPE as appropriate;
b) Check functionality of dimming capability of the lamp canopies once door opened, and
confirm that the light intensity within safe limit;
c) Access to the side lamp canopies only the well-trained personnel and with appropriate
PPE against optical radiation, electric shock and burn hazard;
Never disable the dimming sensor for safe light intensity.

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/16 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
Use flexible hose of appropriate size to connect the condensate outlet (Fig 2-31) to drainage
system, the height of the drainage shall be lower than that of the outlet.
The humidifier shall be connected to purified water mains with stable pressure of 1 bar ± 0.2 bar.
The conductivity of the water shall be no more than 10 µs/cm. Use ¼” PU pneumatic hose to
connect the humidifier inlet to a purified water source.
The USB is used to update software version, update temperature and humidity data for PC
processing. Use Ethernet interface for internet access and remote control or monitoring.
The minimum distance away from the back of the equipment to the wall, furniture or other
installations shall be 300mm!
Voltage, frequency and current for power supply must meet the requirements as designated
on the nameplate! Use power socket matching the power plug of the equipment. Hot
line(L)and neutral line(N)for single phase equipment must not be reversed!
Socket for power supply must be equipped with protective ground (PE) to prevent against
hazard of possible electric shock.
2.2.3 Humidifier
Fig 3 Humidifier
40 Piezoelectric element module
41 Water supply float valve
56 Low level switch
237 Humidifier cover

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/17 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
The humidifier shall be connected to purified water mains with stable pressure of 1 bar ± 0.2
bar. The conductivity of the water shall be no more than 10 µs/cm.
Tape water, distilled water or purified water of general process with conductive ions (TDS in
general), including contaminant of bacteria, microorganisms and organic substances will
degrade the service life of the piezoelectric element of the humidifier.
Unstable supply pressure will affect water level of the humidifier, thus the hysteresis for mist
generating and humidifier efficiency. The piezoelectric element may be damaged if low water
level triggered from time to time.
Check the function of the water supply float valve and low level switch at 3 months intervals to
avoid overflow, performance of the humidifier and low level protection.
Check and clean the ultra-sonic module at 1week intervals or where necessary so that no dirt
buildup or corrosion occurs.
For normal use, the cover of the humidifier (Fig3-237) shall be kept in place with correct
orientation as designated on the marking, to keep the bath tank clean, smooth flow and
distribution of the humidity mist.
2.2.4 Portable temperature/humidity aspirator
Fig 4 Portable temp/humidity aspirator
146 Cable plug
148 Air suction holes
149 Sampling tube
233 Fixing magnetic coins
The portable temperature/humidity aspirator is recommended to be fixed at back side of the
middle shelf. If any this position is not possible for easy operation of the sample or test, the
aspirator may be fixed at any part over shelves, back plenum, left or right wall of the cabinet,
provided that specifications for stability and uniformity are confirmed by testing or calibration
based on the applicable use case. For reliability and long-term operation, note the following:
Air sampling tube (149) not to be squeezed or folded;
Free air flow around, or no coverage of the air suction holes (148);
No condensation, dripping or spillage of the assembly (42);

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/18 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 2 Installing and Operating 2
No direct heat or light on the assembly (42);
Reliable connection of the cable plug (146) and air sampling tube (149) (Fig 1-145, 150).
In case unstable temperature or humidity control, or significant temperature or humidity deviation,
check above points by points first, and then connection of the cable connector (146) and air
sampling tube (147) first. Follow steps of checking (4.5) and replacement (4.4) in case of
damage or malfunction.

XTEMP ENVIRONMENTS (SHANGHAI) CO., LTD.
http://www.xtemp-usa.com/19 / 55
DSEO0711-2-V211119/UXP8401-PG.CC.GE.AR-CD7003/5~+45℃
Chapter 3 Controller Descriptions and Operation 3
Chapter 3 Controller Descriptions and Operation
3.1 Power up
Turn on the power SW (01),system boost up and perform self diagnosis. The HMI touch screen (02)
shows the company LOGO and banner (Fig 5).
Fig 5
For ease of explanation, note the following general rules:
Use a rectangular frame for display window, for example HOME ;
Use square brackets for a key button, for example [SET /START];
Use underline for data input, for example Working temperature, Working humidity etc.
3.2 HOME Screen
After system boost up and self diagnosis, the HMI touch screen (2) turns automatically to screen
for HOME (Fig 6).
Fig 6
This manual suits for next models
8
Table of contents
Popular Climate Chamber manuals by other brands

Thermoline Scientific Equipment
Thermoline Scientific Equipment TCH-150 operating instructions

Anton Paar
Anton Paar TTK 600 reference guide

flowair
flowair LUNA instruction manual

TestEquity
TestEquity 1007S Operation and service manual

ESPEC
ESPEC BTL-433 instruction manual

Binder
Binder UF V operating manual