Part no: 980014
Programming Instructions
for YewdaleDefiant® Motor Relay
(980014)
Programming Instructions
for YewdaleDefiant® Motor Relay
(980014)

YewdaleDefiant® programming instructions Part no: 9800142
Programming Instructions
YewdaleDefiant®Motor Relay (980014)
Specification:
Model: 980014
Power Supply: 230v AC / 120v AC
Working Temperature: -40oC to +85oC
Rated Power: 500w max.
Receiving Frequency: 433.92MHz
Operation mode: Remote / Manual
M1
Motor 1
AC 100-240V
Input power
980030
Low voltage
switch
Motor 2
Motor 3
Motor 4
M2 M3 M4
L L L LR R R RN N N N
DOWN
DOWN
DOWN
DOWN
STOP
STOP
DOWN
Earth
Earth
Earth
Earth
DOWN
DOWN
STOP
Motor 1 Motor 2 Motor 3 Motor 4
Middle control
system
Individual
switch control
Local Group
Control
RS485
Interface
Neutral
Neutral
Neutral
Neutral
Earth
Earth
Switch 1
Switch 2
Switch 3
Switch 4
Earth
RS485B
RS485A
Pilot Lamp
Motor 1
PROG button
Motor 2
PROG button
Motor 3
PROG button
Motor 4
PROG button
UP
UP
UP
UP
UP
UP
UP
Earth
L N
Earth
Neutral
Power Input
Live

Call: +44 (0)1268 570900 Fax: +44 (0)1268 732509 Email: [email protected] Visit: www.yewdale.co.uk 3

YewdaleDefiant® programming instructions Part no: 9800144
Programming Instructions
YewdaleDefiant®Motor Relay (980014)
Operation Instruction:
The maximum running time for a motor is five minutes. The delay between
switching up and down is 0.5 seconds. Program the wireless motors to a Smart
Home Device individually.
Designating motors a channel on the remote control:
The receiver’s
pilot light will
flash slowly for
ten seconds.
The receiver’s light
will flash 3 times.
Programming was
successful.
Press the program button
on the corresponding
programming motor on
the receiver.
Press the LEFT or RIGHT
directional arrow buttons
on the remote to choose the
channel you wish to program.
The channel you select will
light up as you scroll through
the channels on the remote.
Once you have
selected the
channel, press the
UP button.
To tell the receiver which motor you wish to control with the remote, and
on what channel, follow these instructions.

Call: +44 (0)1268 570900 Fax: +44 (0)1268 732509 Email: [email protected] Visit: www.yewdale.co.uk 5
Changing the direction of travel of the blind:
The receiver’s
pilot light will
flash slowly for
ten seconds.
The receiver’s light
will flash 3 times,
confirming the
direction has been
changed correctly.
Press the button on the
receiver that corresponds
with the motor you wish
to adjust. The receiver’s
pilot light will flash slowly
for ten seconds.
Press the LEFT or RIGHT
directional arrow buttons
on the remote to choose the
channel you wish to adjust.
Press the DOWN
button.
Sometimes it is possible for the motor on the blind to be fitted upside down,
which means that the UP and DOWN buttons on the remote are inverted. These
instructions will tell you how to change this. This is not always necessary.

YewdaleDefiant® programming instructions Part no: 9800146
Programming Instructions
YewdaleDefiant®Motor Relay (980014)
Delete single channel memory:
Delete all memories on all channels:
The light will flash
for ten seconds.
The light will flash
for ten seconds.
The receiver’s light
will flash three times.
The receiver’s light
will flash 3 times and
then flash 3 times
again 7 seconds later.
Press the button on the
receiver that corresponds
with the motor you wish
to adjust.
Press the button on the
receiver that corresponds
with the motor you wish to
delete all memories from.
Press the directional
buttons on remote control
to select the channel you
wish to delete.
Press the directional
buttons on remote control
to select the channel you
wish to delete.
Press PROG for 1
second.
Press PROG for 7
seconds.

Call: +44 (0)1268 570900 Fax: +44 (0)1268 732509 Email: [email protected] Visit: www.yewdale.co.uk 7

Yewdale, Enterprise Way,
Wickford, Essex SS11 8DH
Call +44 (0)1268 570900
Fax +44 (0)1268 732509
Email [email protected]o.uk
Visit yewdale.co.uk
For more information on all
Yewdale products, please call
the sales department.
curtain track systems
yewdale.co.uk
see things differently
A concise approach to
a broad spectrum of
commercial curtain
track requirements with
simplistic control options
and designed for almost
every application.
®
cubicle and shower screens
yewdale.co.uk
see things differently
A dedicated range of privacy
and shower curtains with a
primary infection control
focus, providing an all-
encompassing solution to
increased levels of dignity.
®
cubicle and track systems
yewdale.co.uk
see things differently
The industry’s preferred
choice of maintenance
free privacy track systems
providing enhanced personal
welfare throughout the entire
healthcare and public sectors.
®
magnetic anti-ligature system
yewdale.co.uk
see things differently
The only fail-safe range of
exclusive anti-ligature products
designed to maximise the
safety of persons by removing
the death potential where
secure care is required.
®
fabric and blind systems
A comprehensive range
of window blind systems
designed with unique
technical features and to
the exacting specifications
that active commercial
environments demand.
yewdale.co.uk
see things differently
®
Table of contents