Chapter 1 Introduction
1.1 Inspection............................................................................................................................1-2
1.2 Documentation Conventions ...............................................................................................1-3
1.3 Notice ..................................................................................................................................1-4
Chapter 2 General
2.1 Standard Specifications ......................................................................................................2-2
2.2 Model and Suffix Codes ......................................................................................................2-3
Chapter 3 Installation
3.1 External Wiring....................................................................................................................3-2
Chapter 4 Principles of Operation
4.1 Loop Isolation Type (for SDBT-11 Type) .............................................................................4-1
4.2 Field Isolation Type (for SDBT-21 Type) .............................................................................4-2
Chapter 5 Setting
5.1 Names of Components .......................................................................................................5-2
5.2 Setting Jumper (for SDBT-21 Type) ....................................................................................5-3
5.2.1 Check of Setting Jumper and Its Position ..............................................................................5-3
5.3 Setting of Parameters (for SDBT-21 Type) .........................................................................5-4
5.3.1 Configuration of Parameters ..................................................................................................5-4
5.3.2 Description of Parameters......................................................................................................5-5
5.4 Parameter List (for SDBT-21 Type).....................................................................................5-6
Chapter 6 Maintenance
6.1 Test Equipment ...................................................................................................................6-2
6.2 Adjustment (for SDBT-21 Type) ..........................................................................................6-3
6.3 List of Replaceble Parts ......................................................................................................6-5
Chapter 7 Troubleshooting
7.1 Action in Fault Condition (for SDBT-21 Type) .....................................................................7-2
Chapter 8 Power Supply Terminal Connections (Options /TB, /A2TB, and /REK)
8.1 External View and Names of Components .........................................................................8-2
8.2 Power Supply and Ground Wiring.......................................................................................8-3
General Specifications

Blank

1-1
IM 01B04T01-02E
1
2
3
App
1
2
3
5
6
7
8
4
Introduction
Introduction
This manual describes the functions and operations of the SDBT Distributor.
● IntendedReaders
This manual is intended for personnel in charge:
• Installation and wiring
• Instrumentation and setup of the function
• Operation and monitoring of the controller
• Maintenance of equipment
● RelatedDocuments
The following documents all relate to the SDBT Distributor. Read them as necessary.
Manual Title Manual No. Description
Rack-Mounted Instruments IM 1B4F2-01E Describes mounting and wiring for the YS80 rack-mounted instruments.
Model JHT200 Handy Terminal IM 77J50H01-01EN Describes operation of JHT200.
Chapter 1 Introduction

1-2 IM 01B04T01-02E
1.1 Inspection
The SDBT distributor is shipped only after stringent inspection at the factory. Visually inspect
the product upon delivery to make sure it is not damaged in any way.
Store the box and inner packing material of the package in a safe place - they may be
needed if there is a problem with the product and it needs to be sent back for repair.
Check of Model and Suffix Codes
The model and suffix codes are indicated on the Name plate attached to the front cover of
the instrument. Crosscheck this information with the model and suffix codes of Section 2.2
to ensure that the product is as specified in the order.
F0101.ai
100-120VAC 50/60Hz
DISTRIBUTOR
SDBT
-210*S
XXXXXXXXX
4-20mADC
150mA
10.0VA
24-110VDC
100-120VAC 50/60Hz
DISTRIBUTOR
SDBT
-210*S
XXXXXXXXX
4-20mADC
150mA
10.0VA
24-110VDC
Figure 1-1 Name plate for Thermocouple Input (Description example)
Confirmation of the Package Contents
Check the package contents against the list below. If anything is missing or damaged,
immediately contact the sales office from which you purchased the product or your nearest
Yokogawa representative.
• SDBT Distributor................................................................................................1
• Precautions on the Use of the YS80 Series ......................................................1
Downloadable Electronic Manuals
You can download the latest manuals from the following website:
http://www.yokogawa.com/ns/ys/

1-3
IM 01B04T01-02E
1
2
3
App
1
2
3
5
6
7
8
4
Introduction
1.2 Documentation Conventions
This manual uses the following notational conventions.
Symbols
The following symbols are used in this manual.
Markings
Indicates that operating the hardware or software in a particular
manner may damage it or result in a system failure.
Draws attention to information that is essential for understanding the
operation and/or features of the product.
Note Gives additional information to complement the present topic and/or
describe terms specific to this document.
Gives reference locations for further information on the topic.
Description of Displays
Some of the representations of product displays shown in this manual may be exaggerated,
simplified, or partially omitted for reasons of convenience when explaining them.
QR Code
The product has a QR Code pasted for efficient plant maintenance work and asset
information management. It enables confirming the specifications of purchased products and
user’s manuals.
For more details, please refer to the following URL.
https://www.yokogawa.com/qr-code
QR Code is a registered trademark of DENSO WAVE INCORPORATED.

1-4 IM 01B04T01-02E
1.3 Notice
This Instruction Manual
• This manual should be passed on to the end user. Keep at least one extra copy of the
manual in a safe place.
• Read this manual carefully to gain a thorough understanding of how to operate this
product before you start using it.
• This manual is intended to describe the functions of this product. Yokogawa Electric
Corporation (hereinafter simply referred to as Yokogawa) does not guarantee that these
functions are suited to the particular purpose of the user.
• Under absolutely no circumstances may the contents of this manual, in part or in whole,
be transcribed or copied without permission.
• The contents of this manual are subject to change without prior notice.
• Every effort has been made to ensure accuracy in the preparation of this manual. Should
any errors or omissions come to your attention however, please contact your nearest
Yokogawa representative or sales office.
Protection, Safety, and Prohibition against Unauthorized Modification
• The following safety symbols are used on the product and in this manual.
Markings
If this symbol is indicated on the product, the operator should refer
to the explanation given in the instruction manual in order to avoid
personal injury or death to either themselves or other personnel, and/
or damage to the instrument. The manual describes that the operator
should exercise special care to avoid shock or other dangers that may
result in injury or loss of life.
Protective ground terminal:
This symbol indicates that the terminal must be connected to ground
prior to operating the equipment.
Function ground terminal:
This symbol indicates that the terminal must be connected to ground
prior to operating the equipment.
AC voltage:
This symbol indicates that AC voltage is present.
DC voltage:
This symbol indicates that DC voltage is present.
• In order to protect the product and the system controlled by it against damage and ensure
its safe use, make certain that all of the instructions and precautions relating to safety
contained in this document are strictly adhered to. Yokogawa does not guarantee safety
if products are not handled according to these instructions.
• If protection/safety circuits are to be used for the product or the system controlled by it,
they should be externally installed on the product.
• Do not turn off the power of the product during adjustment and parameter setting.
• When you replace the parts or consumables of the product, only use those specified by
Yokogawa.
• If the product is to be used in systems with special requirements for human safety, such
in as nuclear power and radiation related equipment, railway facilities, aircraft facilities,
and medical devices, please consult with your sales representative.
• Do not modify the product.
Force Majeure
• Yokogawa does not make any warranties regarding the product except those mentioned
in the WARRANTY that is provided separately.
• Yokogawa assumes no liability to any party for any loss or damage, direct or indirect,
caused by the use or any unpredictable defect of the product.

2-1
IM 01B04T01-02E
1
2
3
App
1
2
3
5
6
7
8
4
General
General
The SDBT distributor is designed to supply operating power to two-wire type transmitter and
convert 4 to 20 mA DC current signals from this transmitter into output signals.
The SDBT distributor has Loop isolation type (SDBT-11 type) and Filed isolation type
(SDBT-21 type). The SDBT-11 prepares two 1 to 5 V DC output signals, and SDBT-21
prepares one 4 to 20 mA DC output signal in addition to two 1 to 5 V DC output signals. The
SDBT-11 and SDBT-21 have built-in current limiters allowing normal operation even when a
short-circuit occurs on the transmitter side.
F0201.ai
Figure 2-1 External View
Chapter 2 General

2-2 IM 01B04T01-02E
2.1 Standard Specifications
Please see the General Specifications (GS 01B04T01-02E) at the end of this manual.

2-3
IM 01B04T01-02E
1
2
3
App
1
2
3
5
6
7
8
4
General
2.2 Model and Suffix Codes
Model Suffix Codes Option Codes Description
SDBT Distributor
Isolation -11
-21
Loop isolation only
Field (plus loop) isolation
Square Root
Function
0
1
Not provided
Provided (for SDBT-21)
Style Code *S Style S
Option Codes (*1) (*2) /NHR
/FBP
/LOCK
/WSW
/REK
/TB
/A2TB
/A2ER
Without rack case
Power supply fuse bypass
Power supply plug with lock
With spring washer
Mount to same line with EK series rack
With power supply terminal
220V version with power supply terminal
220V version with power supply plug
*1: /LOCK, /REK, /TB, /A2TB, and /A2ER cannot be specified together.
*2: /FBP, /A2TB, and /A2ER cannot be specified together.

Blank

3-1
IM 01B04T01-02E
Installation
1
2
3
App
1
2
3
5
6
7
8
4
Installation
For details of the installation procedure and wiring precautions, refer to the instruction
manual “Installation of Rack-Mounted Instruments” (IM 1B4F2-01E).
Chapter 3 Installation

3-2 IM 01B04T01-02E
3.1 External Wiring
(a) To prepare cables for connection to each terminal, install crimp-on solderless lugs for 4
mm screw on the end of each cable.
(b) Draw the internal unit out from the rack case.
(c) Connect the cables to the correct terminals referring to Table 3-1.
(d) Replace the internal unit into the rack case after completing the wiring.
(e) Always replace the terminal cover after completing the wiring.
The terminal cover cannot be replaced if the internal unit is not installed in the rack
case. The terminal cover should be securely replaced because it has the function of
locking the internal unit.
K
J
H
F
D
C
B
A
8
7
6
5
4
3
2
1
OUT
IN
Terminal arrangement
Figure 3-1 Terminal Layout
Table 3-1 Terminal Wiring
Terminal
Designation Description
A + Output1(1 to 5 V DC)
B -
C + Output3(4 to 20 mA DC)(*1)
D -
F + Output2(1 to 5 V DC)
H -
J
K
Do not connect to the output terminal when the terminal is not in use.
Note1: For SDBT-21 type only.
Terminal
Designation Description
1 + Transmitter(Input)
2 -
3
4
5
6
7COM(*2)
8
Note2: Common for connection of intrinsic safety barrier.
Applicable Cables
(1) Signal circuit wiring
• Cross-sectional area of the cable conductor: 0.5 to 0.75 mm2
• Examples of applicable cables: Single core PVC insulated flexible cable (VSF)
stranded wires (JIS C 3306); heat-resistant vinyl-
insulated cable (UL style 1007)
(2) Power supply wiring
• Cross-sectional area of the cable conductor: 1.25 to 2.00 mm2
• Examples of applicable cables: 600 V PVC insulated cable (1 V) stranded wires (JIS
C 3307);PVC insulated cable for electrical apparatus
(KIV) stranded wires (JIS C 3316)

4-1
IM 01B04T01-02E
Principles of Operation
1
2
3
App
1
2
3
5
6
7
8
4
4.1 Loop Isolation Type (for SDBT-11 Type)
The SDBT-11 supplies 25.0 to 25.5 V DC to two-wire transmitter through a current limiter,
and receives 4 to 20 mA DC current signals. The current signals are converted into 1 to 5 V
DC signals, then are output through output amplifier.
+
–
1
2
7
–
+
–
+
F0401.ai
Current Limiter
4 to 20 mA DC
250 Ω
Two-wire Transmitter
Power
Supply
Circuit
GND
N–
Supply
L+
A+
–
B
F
H
Output 1 (1 to 5 V DC)
Output 2 (1 to 5 V DC)
–
+
Figure 4-1 Functional Block Diagram for Loop Isolation Type
Chapter 4 Principles of Operation

4-2 IM 01B04T01-02E
4.2 Field Isolation Type (for SDBT-21 Type)
The SDBT-21 supplies 25.0 to 25.5 V DC to two-wire transmitter through a current limiter,
and receives 4 to 20 mA DC current signals. The current signals are converted into 1 to 5 V
DC signals, then are converted into digital data in A/D conversion circuit.
The digital data has signal processing (square root characteristic etc.) in microprocessor
to be Pulse Width Modulation (PWM), then is coverted into 1 to 5 V DC or 4 to 20 mA DC
signals in output circuit through optical-isolation circuit.
F0402.ai
Output 1 (1 to 5 V DC)
Supply
B
A
Output
Circuit
Power
Supply
Circuit
Output
Circuit
V/I
F
L+
N–
Isolation Circuit Output 2 (1 to 5 V DC)
Output 3 (4 to 20 mA DC)
C
D
–
+
Isolation Circuit
A/D
Conversion
Circuit
Micro-
processor
H
+
–
+
–
GND
Handy
Terminal
Two-wire Transmitter
4 to 20 mA DC
Current Limiter
1
2
7
250 Ω
+
–
Figure 4-2 Functional Block Diagram for Field Isolation Type

5-1
IM 01B04T01-02E
Setting
1
2
3
App
1
2
3
5
6
7
8
4
Setting
Items to Confirm before Start of Operation
Before you start operation, inspect and confirm the following items:
(1)Draw out the internal unit from the rack case, and make sure that the specified fuses are
properly mounted in the fuse holders at the rear of the internal unit.
(2)When inserting the internal unit into the rack case, firmly connect the multi-pin connectors
for connecting the internal unit and the case.
(3)Make sure that power plugs are properly connected to the power outlet.
(4)Make sure that external wiring to the terminal block is properly connected.
The SDBT distributor is made ready for operation by simply turning on the power once the
installation and wiring are completed. The distributor does not require parameter settings
and the like if there is no change in the specifications at order.
Chapter 5 Setting

5-2 IM 01B04T01-02E
5.1 Names of Components
Tag plate
Name plate
Output terminal block
Main board
Terminal cover and handle for
drawing out the internal unit
Two-pole plug with earthing contact
Multi-pin connector
Input terminal block
Rack case
F0501.ai
BRAIN connector
(w / cover)
(No connector for
SDBT-110 type)
Figure 5-1 Names of Components

5-3
IM 01B04T01-02E
Setting
1
2
3
App
1
2
3
5
6
7
8
4
5.2 Setting Jumper (for SDBT-21 Type)
This instrument has the following setting jumper:
• Parameter Write Protect (JP2): ON/OFF
5.2.1 Check of Setting Jumper and Its Position
Setting jumper is on the main board of the internal unit.
Check the setting jumper in the following procedure.
(a) Pull forward the terminal cover, and draw the internal unit out from the rack case.
(b) Check that the jumper on the main board of the internal unit is set to obtain the desired
action.
(c) Use the tweezers to change the position of jumper.
(d) Put the internal unit back into the rack case.
(e) Replace the terminal cover.
OFF JP2
ON
(W.P.)
Position and function of setting jumper
ON:
Parameter change
by Handy Terminal
is prohibited.
Setting jumper (factory-set default)
F0502.ai
Parameter
write protect
Figure 5-2 Function and Set Point of Jumper

5-4 IM 01B04T01-02E
5.3 Setting of Parameters (for SDBT-21 Type)
This instrument has BRAIN communication parameters for specifying functions and
adjusting input. Connect JHT200 Handy Terminal (Note1) to the instrument to display or set
parameters.
Note 1: BT200 BRAIN Terminal of Yokogawa Electric Corporation can also be used.
When connecting the JHT200 Handy Terminal, the adapter for modular-jack (model
E9786WH) is required. When using the BT200 BRAIN Terminal of YOKOGAWA
Electric Corporation, the communication cable of 5-pin connector type (model
F9182EE) and the adapter for modularjack (model E9786WH) are required.
For details of operation and adjusting procedures of JHT200 Handy Terminal, refer to
the instruction manual ‘‘JHT200 Handy Terminal’’ (IM 77J50H01-01EN).
<Connection>
Adapter for modular jack
(E9786WH)
BRAIN connector
JHT200
Handy Terminal
Cable of 5-pin
connector type
(F9182EE)
F0503.ai
Figure 5-3 Connection
5.3.1 Configuration of Parameters
BRAIN communication parameters consist of the following parameters.
• Display (A & B parameters)
• Settings of Input and output (D parameters)
• Adjustment (P parameters)
• Test (Q parameters)
Table of contents