521149-UTG-C-0612
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
GAS-FIRED RESIDENTIAL
TWO STAGE PSC MULTI-POSITION
GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: TM8T / TMLT
NATURAL GAS
60 - 120 MBH INPUT
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
5-year limited parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for
replacement or closing for new home construction.
TECHNICAL
GUIDE
TECHNICAL
GUIDE
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
FEATURES
• Two stage heating operation includes two stage gas valve,
two stage inducer operation and 4 speed PSC blower
operation. Adjustable delay timer allows two stage operation
with a single stage thermostat.
• Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
• Compact, easy to install, ideal height 33" tall cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy access to controls to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement application.
• All models are convertable to use propane (LP) gas.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied for
add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Solid removable bottom panel allows easy conversion.
• Airflow leakage less than 1% of nominal airflow for
ductblaster conditions.
• No knockouts to deal with, making installation easier.
• Movable duct connector flanges for application flexibility.
• Quiet inducer operation, burner, and blower operation.
• Inducer rotates for easy conversion of venting options.
• Fully supported blower assembly for easy access and
removal of blower.
• External air filters used for maximum flexibility in meeting
customers IAQ needs.
• Insulated blower compartment for thermal and acoustic
performance.
• Low NOx models have been designed to meet specific code
requirements.
• Venting applications - may be installed as a common vent
with other gas-fired appliances or use a masonry chimney.
• 1/4 turn knobs provided for easy independent door removal.
521149-UTG-C-0612
2Johnson Controls Unitary Products
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
LEFT SIDE RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
29.5”
28.5”
Electrical
Entry
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models Nominal
CFM Cabinet
Size Cabinet Dimensions (Inches)
ABC
TM(8,L)T060A12MP11 1200 A 14 1/2 13 3/8 10.3
TM(8,L)T080B12MP11 1200 B 17 1/2 16 3/8 11.8
TM(8,L)T080C16MP11 1600 C 21 19 7/8 13.6
TM(8,L)T100C16MP11 1600 C 21 19 7/8 13.6
TM(8,L)T100C20MP11 2000 C 21 19 7/8 13.6
TM(8,L)T120C20MP11 2000 C 21 19 7/8 13.6
Table 1: Ratings & Physical / Electrical Data
Models High Fire
Input Low Fire
Input High Fire
Output Low Fire
Output Nominal
Airflow AFUE Max.
Over-current
Protect
Max. Outlet
Air Temp
MBH MBH MBH MBH CFM % °F
TM(8,L)T060A12MP11 60 39 47 31 1200 80.0 10 160
TM(8,L)T080B12MP11 80 52 63 42 1200 80.0 10 160
TM(8,L)T080C16MP11 80 52 63 42 1600 80.0 15 160
TM(8,L)T100C16MP11 100 65 80 52 1600 80.0 15 160
TM(8,L)T100C20MP11 100 65 80 52 2000 80.0 20 160
TM(8,L)T120C20MP11 120 78 96 62 2000 80.0 20 160
Models High Fire
Air Temp. Rise Low Fire
Air Temp. Rise Blower Blower
Size Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way
Operating
weight
°F °F HP Amps In. Lbs.
TM(8,L)T060A12MP11 30-60 15-45 1/3 4.8 11 x 8 7.0 14 94
TM(8,L)T080B12MP11 30-60 20-50 1/3 4.8 11 x 8 7.0 14 103
TM(8,L)T080C16MP11 30-60 20-50 1/2 7.0 11 x 10 10.0 14 114
TM(8,L)T100C16MP11 30-60 20-50 1/2 7.0 11 x 10 10.0 14 118
TM(8,L)T100C20MP11 30-60 20-50 1 14.5 11 x 11 17.0 12 122
TM(8,L)T120C20MP11 30-60 20-50 1 14.5 11 x 11 17.0 12 129
521149-UTG-C-0612
Johnson Controls Unitary Products 3
HORIZONTAL SIDEWALL VENTING
For applications where vertical venting is not possible, the only
approved method of horizontal venting is the use of an auxiliary
power vent. Auxilary power venters must be approved by CSA,
UL, or other recognized safety agencies. Follow all application
and installation details provided by the manufacturer of the
power vent.
FILTER PERFORMANCE
The airflow capacity data published in the “Blower Perfor-
mance” table shown represents blower performance WITHOUT
filters.
All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabi-
net. DO NOT attempt to install any filters inside the furnace. 1. Air velocity through throwaway type filters may not exceed 300 feet per min-
ute (91.4 m/min). All velocities over this require the use of high velocity fil-
ters.
2. Do not exceed 1800 CFM using a single side returnand a 16x25 filter. For
CFM greater than 1800, you may use two side returns orone side and the
bottom or one return with a transition to allow use of a 20x25 filter.
ACCESSORIES
Propane (LP) Conversion Kit -
1NP0347 - All Models
This accessory conversion kit may be used to convert natural
gas units for propane (LP) operation.
Side Return Filter Racks -
1SR0200 - All Models
1SR0302 - All Models
1SF0101 - All Models
Bottom Return Filter Racks -
1BR0514 or 1BR0614 - For 14-1/2” cabinets
1BR0517 or 1BR0617 - For 17-1/2” cabinets
1BR0521 or 1BR0621 - For 21” cabinets
1BR05xx series are galvanized steel filter racks. 1BR06xx are
pre-painted steel filter racks to match the appearance of the fur-
nace cabinet.
Masonry Chimney Kits -
For installations where these furnaces are vented using existing
or new lined masonry chimneys.
1CK0603
1CK0604
Combustible Floor Base Kit -
For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations. These kits
are also required in any applications where the furnace in
installed in a downflow configuration without an evaporator coil,
where the combustible floor base kit provides access for com-
bustible airflow.
1CB0514 - For 14-1/2” cabinets
1CB0517 - For 17-1/2” cabinets
1CB0521 - For 21” cabinets
High Altitude Pressure Switches -
For installation where the altitude is less than 5,000 feet it is not
required that the pressure switch be changed. For altitudes
above 5,000 feet, see kits below.
1PS3309
Thermostats - Compatible thermostat controls are available
through accessory sourcing. For optimum performance and
installation, refer to the UPGNET “Low Voltage Wiring Diagram”
document to select and apply controls.
Single side return above 1800 CFM is approved as long as
the filter velocity does not exceed filter manufacturer’s rec-
ommendation and a transition is used to allow use on a
20x25 filter.
Recommended Filter Sizes
CFM Cabinet
Size Side
(in) Bottom
(in)
1200 A 16 x 25 14 x 25
1200 B 16 x 25 16 x 25
1600 C 16 x 25 20 x 25
2000 C (2) 16 x 25 20 x 25
NOTICE
Unit Clearances to Combustibles (All dimensions in inches, and all surfaces identified with the unit in an upflow configuration)
Application Top Front Rear Left
Side Right
Side Flue Floor/
Bottom Closet Alcove Attic Line
Contact
Upflow 1 1 0 0 0 6 Combustible Yes Yes Yes No
Upflow B-Vent 1 1 0 0 0 1 Combustible Yes Yes Yes No
Downflow 1 1 0 0 0 6 11
1. Special floor base or air conditioning coil required for use on combustible floor.
Yes Yes Yes No
Downflow B-Vent 1 1 0 0 0 1 11Yes Yes Yes No
Horizontal 1 1 0 0 0 6 Combustible No Yes Yes Yes2
2. Line contact only permitted between lines formed by the intersection of the rear panel and side panel (top in horizontal position) of the furnace jacket and build-
ing joists, studs or framing.
Horizontal B-Vent 1 1 0 0 0 1 Combustible No Yes Yes Yes2
Subject to change without notice. Published in U.S.A. 521149-UTG-C-0612
Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 521149-UTG-B-0210
York International Corp.
5005 York Drive
Norman, OK 73069
1. Airflow expressed in standard cubic feet per minute (CFM).
2. Motor voltage at 115 V.
3. Airflow through motor side (right side return) maybe slightly less than the data shown above.
Blower Performance CFM - Any Position
Models Speed
Bottom Airflow Data (SCFM)
Ext. Static Pressure (in. H2O)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Bottom Return (without filter)
TM(8,L)T060A12MP11
High 1358 1341 1319 1303 1275 1238 1190 1130 1062 943
Medium High 1097 1083 1075 1064 1042 1024 997 962 906 821
Medium Low 935 928 920 899 872 840 809 771 731 659
Low 800 779 763 736 711 687 657 622 584 529
TM(8,L)T080B12MP11
High 1329 1307 1285 1247 1195 1143 1091 1027 927 806
Medium High 994 1004 1008 984 970 941 893 839 773 669
Medium Low 786 790 782 781 761 743 726 685 630 540
Low 655 654 647 629 620 594 560 524 469 399
TM(8,L)T080C16MP11
High 1881 1822 1783 1696 1602 1539 1465 1394 1267 1130
Medium High 1553 1535 1492 1456 1408 1343 1279 1226 1113 1014
Medium Low 1312 1286 1288 1260 1205 1143 1091 1029 966 841
Low 1169 1166 1128 1098 1069 1032 987 909 835 747
TM(8,L)T100C16MP11
High 2069 2014 1956 1885 1820 1748 1668 1577 1468 1362
Medium High 1662 1656 1639 1608 1586 1544 1491 1421 1338 1204
Medium 1368 1371 1377 1376 1367 1334 1295 1250 1188 1104
Low 1016 1014 1018 1030 1012 996 975 944 898 852
TM(8,L)T100C20MP11
High 2893 2774 2687 2589 2478 2376 2255 2120 1978 1824
Medium High 2272 2243 2204 2169 2086 2018 1940 1842 1743 1602
Medium Low 1765 1752 1737 1718 1674 1619 1561 1493 1437 1312
Low 1425 1380 1409 1378 1307 1274 1226 1180 1113 1025
TM(8,L)T120C20MP11
High 2701 2620 2533 2429 2338 2227 2112 1993 1861 1706
Medium High 2125 2083 2046 1994 1955 1901 1857 1737 1621 1497
Medium Low 1664 1664 1647 1619 1580 1555 1468 1392 1332 1226
Low 1358 1339 1330 1318 1286 1235 1185 1141 1060 938
Left Side Return (without filter)
TM(8,L)T060A12MP11
High 1406 1401 1394 1379 1338 1304 1261 1202 1135 1040
Medium High 1129 1126 1107 1094 1076 1047 1010 966 921 843
Medium Low 970 947 933 916 890 863 827 789 741 668
Low 834 809 797 768 740 710 677 634 586 534
TM(8,L)T080B12MP11
High 1274 1285 1255 1239 1207 1158 1111 1049 979 830
Medium High 975 974 968 960 948 923 879 823 756 672
Medium Low 777 771 772 762 752 734 695 651 604 529
Low 647 634 623 610 602 588 552 506 457 381
TM(8,L)T080C16MP11
High 1825 1781 1746 1695 1641 1587 1521 1429 1330 1184
Medium High 1516 1493 1482 1464 1442 1411 1343 1275 1192 1035
Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851
Low 1126 1115 1095 1049 1027 996 957 929 840 742
TM(8,L)T100C16MP11
High 2009 1994 1933 1893 1836 1763 1691 1606 1508 1389
Medium High 1523 1506 1521 1490 1466 1435 1393 1326 1241 1119
Medium Low 1230 1249 1245 1230 1218 1195 1161 1120 1039 949
Low 1126 1115 1095 1049 1027 996 957 929 840 742
TM(8,L)T100C20MP11
High 2964 2886 2794 2707 2623 2522 2415 2281 2149 2012
Medium High 2192 2178 2150 2109 2098 2007 1956 1888 1795 1671
Medium Low 1699 1695 1706 1632 1612 1568 1519 1460 1392 1293
Low 1361 1356 1337 1304 1267 1243 1191 1149 1077 994
TM(8,L)T120C20MP11
High 2828 2768 2699 2612 2524 2423 2308 2219 2118 1982
Medium High 2085 2073 2042 2029 1967 1896 1893 1816 1717 1635
Medium Low 1620 1631 1636 1593 1567 1557 1520 1476 1407 1263
Low 1322 1311 1302 1271 1241 1201 1162 1101 1042 979

This manual suits for next models

1

Other York Furnace manuals

York TM9T Quick start guide

York

York TM9T Quick start guide

York P4UCB30N12206 User manual

York

York P4UCB30N12206 User manual

York TG9S Quick start guide

York

York TG9S Quick start guide

York GF9S*DH User manual

York

York GF9S*DH User manual

York AFFINITY PS8 Owner's manual

York

York AFFINITY PS8 Owner's manual

York G8C Series Quick start guide

York

York G8C Series Quick start guide

York GY9S-UP Quick start guide

York

York GY9S-UP Quick start guide

York PV9 Quick start guide

York

York PV9 Quick start guide

York PV9 Series Quick start guide

York

York PV9 Series Quick start guide

York PS9A12N040UP11 Quick start guide

York

York PS9A12N040UP11 Quick start guide

York P*UR 40 User manual

York

York P*UR 40 User manual

York P2MP Series User manual

York

York P2MP Series User manual

York PC9*DH Quick start guide

York

York PC9*DH Quick start guide

York P*DU-"V" Manual

York

York P*DU-"V" Manual

York P*XU/G9D-UP User manual

York

York P*XU/G9D-UP User manual

York Affinity PC9 Quick start guide

York

York Affinity PC9 Quick start guide

York TM9T Quick start guide

York

York TM9T Quick start guide

York TG9S Quick start guide

York

York TG9S Quick start guide

York YP9C Series Quick start guide

York

York YP9C Series Quick start guide

York DGAA056BDTA User manual

York

York DGAA056BDTA User manual

York PV9A12N040UP11 Quick start guide

York

York PV9A12N040UP11 Quick start guide

York YM8M060A12MP11 Quick start guide

York

York YM8M060A12MP11 Quick start guide

York TM9V*C User manual

York

York TM9V*C User manual

York MM9E Series User manual

York

York MM9E Series User manual

Popular Furnace manuals by other brands

Duotronpro S-6100 operating instructions

Duotronpro

Duotronpro S-6100 operating instructions

Lennox O23 installation instructions

Lennox

Lennox O23 installation instructions

Goodman GMES8 U Series Service and Troubleshooting

Goodman

Goodman GMES8 U Series Service and Troubleshooting

ICP H9UHX060F12A installation instructions

ICP

ICP H9UHX060F12A installation instructions

Goodman ACVC96 BA Series Service and Troubleshooting

Goodman

Goodman ACVC96 BA Series Service and Troubleshooting

Bryant GAS-FIRED INDUCED-COMBUSTION FURNACES 373LAV Installation, start-up, and operating instructions

Bryant

Bryant GAS-FIRED INDUCED-COMBUSTION FURNACES 373LAV Installation, start-up, and operating instructions

Bryant 394 installation instructions

Bryant

Bryant 394 installation instructions

VERDER Carbolite Gero CWF 12/5 Installation, operation and maintenance instructions

VERDER

VERDER Carbolite Gero CWF 12/5 Installation, operation and maintenance instructions

Wood master Ultra Series user manual

Wood master

Wood master Ultra Series user manual

Allied Air 80G1UH2V installation instructions

Allied Air

Allied Air 80G1UH2V installation instructions

England's Stove Works 28-3500 Installation and operation manual

England's Stove Works

England's Stove Works 28-3500 Installation and operation manual

Williams 3508732 user manual

Williams

Williams 3508732 user manual

United States Stove ASHLEY AF1300E Owner's installation and operation manual

United States Stove

United States Stove ASHLEY AF1300E Owner's installation and operation manual

Fluke 9118A user manual

Fluke

Fluke 9118A user manual

United States Stove Company SP8500 owner's manual

United States Stove Company

United States Stove Company SP8500 owner's manual

HEIL F8MVL installation instructions

HEIL

HEIL F8MVL installation instructions

Johnson Controls EB Series User's information, maintenance and service manual

Johnson Controls

Johnson Controls EB Series User's information, maintenance and service manual

VERDER Carbolite Gero EVT 12/600B Installation, operation and maintenance instructions

VERDER

VERDER Carbolite Gero EVT 12/600B Installation, operation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.