06 Installation instructions
803341 V3.00 June 2019 - Zip G4 tap range
Technical support
Australia Ph: 1800 460 222 , UK Tel: 0345 6 005 005 email: service@zipindustries .co.uk
Generic installation instructions
Clearance envelope
• See adjacent diagram.
• A clearance envelope around all Command-Centres must be
provided to allow adequate ventilation for the safe and effective
use of the HydroTap G4 system.
• The tap must have adequate clearance to correctly dress tubes
and hoses without kink or sagging.
• Allow space for the threaded boss and the connection pipes.
Clearance
envelope
535mm
min. 300mm
335mm
All plastic pipes / silicone tubes must be trimmed to size. They must have a constant fall to the Command-
Centre.
The connection tubes supplied with the tap head assembly CANNOT be lengthened.
Command Centre connection table - for reference
Mains In Mains water supply. Wholesome (cat 1).
Mains power IEC power lead, 230V AC 50Hz 13A socket.
USB Connect to the Tap—make sure they click together and are secured up off
the floor of the cupboard.
CO2IN Connect the 1/4’ connection from the CO2cylinder.
Boiling out Cut to length Red hose from tap. No kinks, bends or loops. Must fall from tap
directly to Command Centre.
Chilled out Connect the JG 1/4’ pipe to this push fit outlet. There is another push fit JG
fitting for the tap.
Vent Cut to length clear hose from tap. No kinks, bends or loops. Must fall from
tap directly to Command Centre.
Sparkling out Connect a piece of JG 1/4’ pipe to this outlet. Fit the carbonation valve to the
pipe, then connect valve to tap.
Bypass in Only used for Booster (supplied with 240/175 models) & scale filter. Braided
hose from Booster outlet (or scale filter).
Bypass out Only used for Booster (supplied with 240/175 models) & scale filter. Braided
hose from Booster inlet (or scale filter).
Mixer in
Only used when supplied with a special 3 hose mixer tap from Zip. Leave the
red dust caps on if not used.
If using a mixer tap connect to the blue marked braided hose from mixer tap.
Mixer out
Only used when supplied with a special 3 hose mixer tap from Zip. Leave the
red dust caps on if not used.
If using a mixer tap connect to the red marked braided hose from mixer tap.
Cut hoses to length, no clamps are required on silicone hoses.