manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ZyAuro
  6. •
  7. Monitor
  8. •
  9. ZyAuro ZG10U User manual

ZyAuro ZG10U User manual

Popular Monitor manuals by other brands

Samsung ME32C user manual

Samsung

Samsung ME32C user manual

ViewSonic VA926-LED user guide

ViewSonic

ViewSonic VA926-LED user guide

Furuno Mu 120c Operator's manual

Furuno

Furuno Mu 120c Operator's manual

Asus VB171D - 17" LCD Monitor Service manual

Asus

Asus VB171D - 17" LCD Monitor Service manual

AOC 9GLR Technical specifications

AOC

AOC 9GLR Technical specifications

DMG RAFFAELLO manual

DMG

DMG RAFFAELLO manual

AOC LM720 - 17" Technical specifications

AOC

AOC LM720 - 17" Technical specifications

Sony Trinitron GDM-F500 Service manual

Sony

Sony Trinitron GDM-F500 Service manual

Memorex MT1701 user guide

Memorex

Memorex MT1701 user guide

ViewSonic VE510s-4 Service manual

ViewSonic

ViewSonic VE510s-4 Service manual

Farenheit T-1503CM instruction manual

Farenheit

Farenheit T-1503CM instruction manual

Ditel DINOS DN129/AT Quick installation guide

Ditel

Ditel DINOS DN129/AT Quick installation guide

Sony SDM-S51 Specifications

Sony

Sony SDM-S51 Specifications

Kenwood DMX1025BT quick start guide

Kenwood

Kenwood DMX1025BT quick start guide

Dell S2409WFP user guide

Dell

Dell S2409WFP user guide

EverFocus EN-7517E instruction manual

EverFocus

EverFocus EN-7517E instruction manual

Dell P3222QE user guide

Dell

Dell P3222QE user guide

Panasonic TH152UX1 - 152" PLASMA TV Service manual

Panasonic

Panasonic TH152UX1 - 152" PLASMA TV Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CO2 Monitor Operating Instructions
Model: ZG10U
Table of Contents
1 .Product Instruction
2. Package Content Check & Main Unit View
3. LCD Display Symbol
4. SEU (Sensor Unit) Function Instruction
5. RDU (Remote Display Unit) Function Instruction
6. Safety Notes
7. Caring For Product
8. Installation Instruction
9. Customizing Settings
10. CO2 & Temperature Specification
11. Weight & Dimension
12. Fault Codes & Troubleshooting Guide
1. Product Instruction
Thank you for selecting the ZG10U CO2 Monitor. It is designed to detect the
presence of Carbon Dioxide in the ambient air to protect people in confined spaces.
High concentrations of CO2 in confined spaces are dangerous, and may lead to
health problems ranging from headaches and fatigue to asphyxiation and death.
The ZG10U CO2 Monitor is with the audible alarm and visual indication which will
activate when CO2 concentration reaches a pre-set level. Detection of high levels
of CO2 will also activate a relay that could be used for a fan to ventilate the
confined space and reduce CO2 concentration in the area. The ZG10U CO2
Monitor can be widely used in CO2 storage areas, breweries, wineries, cellars,
beverage dispensing areas, and fast food outlets.
ZG10U CO2 Monitor is cost-effective and has many features:
1.NDIR (Non-Dispersive Infrared) technology is used to measure CO2
concentration up to 50,000 ppm (parts per million).
2.With the SEU (Sensor Unit) and RDU (Remote Display Unit), it can connect
up to 3 RDU for safety notices.
3.Large digital LCD display clearly indicates the ambient CO2 concentration and
temperature.
4.Relay output can automatically control a fan to ventilate confined spaces.
5.Audible and visual alarm indications.
6.IP54 Water Proof Protection of SEU( Sensor Unit) except backside when
installed on the wall
2. Package Content Check & Main Unit View
The ZG10U package comprises the following parts:
Main Unit:
Accessories:
Plug lock 1 pc Screw 10pcs Expansion
plug 10 pcs
Nail cable clip 10 pcs Warning paper 1 pc
Caution: please take off the rubber cap and put it to the position L when
ZG10U is taken from the package, the vents is not blocked while ZG10U is
working.
SEU (Sensor Unit)
RDU (Remote Display Unit)
3. LCD Display Symbol
Symbol Meaning Description
CO2 Concentration ppm
(Parts Per Million) ambient CO2 concentration
Temperature (Celsius) ambient temperature in
Celsius
Temperature
(Fahrenheit) ambient temperature in
Fahrenheit
Alarm alarm icon
Diagnose Test communications
between the SEU and RDU
First Alarm level
The relay will be triggered
when CO2 concentration
exceeds the first alarm
level, the Red 1 LED will
flash, and buzzer will sound
Second Alarm level
Safety Notice “ESC”
displays on LCD when CO2
concentration exceeds the
second alarm level. The
Red 1& Red 2 LEDs will
flash, and buzzer will sound
Calibration
To calibrate the CO2 sensor
when the accuracy deviates
from the actual CO2
concentration.
Recover Factory Setting To recover factory default
settings and cancel any
customized settings
ESC
To indicate the CO2
leakage once the CO2 level
is above the second alarm
level
Hi The CO2 concentration is
above 5%.
4. SEU (Sensor Unit) Function Instruction
The SEU (Sensor Unit) should be placed in a room where the CO2 is likely to
accumulate, such as a room where CO2 is stored, like an area with CO2
beverages. The large LCD displays the ambient CO2 concentration and the
temperature.
The SEU has the “DIAG”,”AL1”,’AL2”‘CALI”, “ReFactSet” function. The “DIAG”
function executes communication tests between the SEU and RDU. The user can
do the calibration under the “CALI” mode when necessary. If data-setting is done
incorrectly, the user can use the “ReFactSet” back to the original factory setting.
There have “AL1” ‘AL2” two alarm levels, the alarm level is adjustable, the first
alarm level is with parameter 0.5%, 1%, 1.5%, 2%, the default first alarm level is
1.5% . The second alarm level is with parameter 1.5%, 2%, 2.5%, 3%, 3.5%, 4%,
the default second alarm level is 3%.
When the ZG10U CO2 Monitor detects CO2 concentration that exceeds the first
alarm level, the red 1 LED will blink and the buzzer will sound intermittently, the
relay will be triggered. When CO2 concentration drops the first alarm level, the red
1 LED will stop blinking and buzzer will stop beeping.
If the concentration of CO2 continues to rise above the second alarm level, the red
1 and red 2 LED’s will flash together and the tempo of the buzzer will increase.
When CO2 concentration drops below the second alarm level, even to the first
alarm level, the red 1 and red 2 LED’s will remain blinking, and the buzzer will
remain beeping. Unless the ZG10U is restarted, by means of reset button of
ZG10U or unplug the AC adapter and reconnected it.
The green LED will light continuously when the power is normally supplied.
Warning: If the ambient CO2 concentration reaches the second alarm level, on
SEU & RDU, there will be a safety notice “ESC” displays on the LCD, Careful
action, such as ventilating the space, must be taken before entering the room
where the SEU is placed.
To clear the flashing “ESC” from the LCD, use the “ReFactSet” to restore the unit
to the original factory settings, or unplug the AC adapter and reconnect it to the
power.
If the communication cable between the SEU & RDU doesn’t connect well, like the
communication cable looses in the Input port, the fault LED of SEU will blink,
reconnect the cable, if the cable is inserted into the output port, on RDU, after ºC/
ºF flashing one minute, the “Er7” will flash on LCD. Unplug the cable and plug it
into the Input port. The unit will work normally after corrective action.
If cleaning places where the SEU is installed, first take off rubber cap off and
putting it on the position of gas entry. Water will not enter into the SEU during
cleaning. The following picture shows the position changes of the rubber cap.
5. RDU (Remote Display Unit) Function Instruction
The RDU (Remote Display Unit) should be placed outside the room when in use.
The RDU is connected to the SEU with a wire that has a maximum length of 25
feet. The RDU should be placed where it can be conveniently observed before
entering the room where the SEU is located. The RDU is a repeater, and displays
the measurements made by the SEU on an easy-to-read digital LCD along with
important safety information.
The RDU has “DIAG” function. The “DIAG” can test the communication between
the SEU and RDU. Resetting the ZG10U CO2 Monitor is only available from SEU.
6. Safety Notes
Warning: Your safety is very important to us. To ensure to use the product correctly
and safety, please read these warnings and the entire User Manual before using
the product. Otherwise, the protection provided by the equipment may be impaired.
These warnings provide important safety information and should be observed at all
times.
1. Please handle the device carefully; do not subject the product to impact or
shock.
2. Do not place the unit, or the adaptor near a heat source. Heat can cause
distortion of the unit, which may result in an explosion or fire.
3. Do not touch the exposed electronic circuitry of the device under any
circumstances, as there is the dangerous of electric shocks.
4. Please use only the included power adaptor. Improper power adaptor or power
sources can cause serious damage to the product, or result in injury or death to
the user.
5. Please use the “DIAG” function to verify the communication between SEU and
RDU, to make sure the communication between SEU and RDU works normally.
6. Please make sure that the power adaptor is mounted by plug lock tightly, so the
power adapter can not be disconnected without using of mechanical tools.
7. Do not enter into the room directly if there has safety notice “ESC” displays on
the LCD of SEU & RDU. Some careful and protective action must be taken
before entering the room where the SEU is installed.
8. Please take care of cable connection between SEU and RDU. Make sure the
cable from SEU is connected into the INPUT port of RDU.
9. Please ensure the external power supply is normally supplied to ventilation fan
while the relay is working. If there has no normally power supply to the fan, the
relay will not work, which may result in potential danger with high CO2
concentration in confined space.
7. Caring For Product
To make sure to receive the maximum benefit from using this product, please
observe the follow guidelines.
1. Repair - Do not attempt to repair the product or modify the circuitry by yourself.
Please contact your local dealer or a qualified repairman if the product needs
servicing.
2. Cleaning - Disconnect the power before cleaning. Use a damp cloth. Do not use
liquid cleaning agents such as benzene, thinner or aerosols, as these will
damage the device.
3. Maintenance – We recommend users to test the communication between the
SEU and RDU under ‘DIAG” function to verify the working conditions for the
SEU and RDU. If the four LED’s blink and the buzzer of SEU and RDU sound
simultaneously, it indicates that SEU and RDU work normally. When the LCD
displays a safety icon “ESC”, please take immediate protective action to check if
CO2 leakage has occurred. We suggest users to do the calibration and
thorough function check once within two year to make sure that the ZG10U
CO2 Monitor is working properly.
8. Installation Instructions
Please carefully take out the SEU (Sensor Unit), RDU (Remote Display Unit),
panel holders, network cable connector, 7 meters communication cable, user
manual, plug lock, screws, expansion plugs, nail cable clips, warning paper from
the package.
Step-by-Step Installation:
1. Choose a suitable location to install the SEU. Fix the panel holder on the wall
with the four screws (included); the recommend installation height is about 0.45
meters (1.5 feet) from floor and close to the manifolds and valves as possible.
2. Put the SEU on the panel holder, making sure that they are connected tightly.
3. Fix another panel holder in a suitable location outside the monitored space with
screws (included). Push the RDU onto panel holder, and stick the warning
paper next to RDU.
4. The communication cable is pre-wired to the SEU. Route the cable to the RDU
and fixed the communication cable to the wall by nail cable clips, and then plug
the cable into the input port on the RDU. Communication is now ready between
the SEU and RDU.
5. The ZG10U CO2 Monitor has one relay output. The relay cable is pre-wired to
SEU. The relay can control a fan or blower to ventilate the monitored space
when necessary. The relay will be triggered when the CO2 concentration
exceeds the first alarm level.
6. After finishing the installation, Connected the AC power adapter into the
electrical supply outlet.
Mount the Plug lock by expansion plugs so that the power adapter cannot be
disconnected without use of mechanical tools.
7. When the power has been connected, The SEU and the RDU will begin to work.
Please use the “DIAG“ function to verify the communication between SEU and
SEU( Sensor Unit) RDU (Remote Display Unit) Panel holders
Network cable
connector 7 meters communication cable User manual
A. LCD display H. Enter Button
B. Yellow LED( Fault indication) I. Communication Cable to RDU
C. Red 2 LED( AL2 ) J. Relay output
D.Red 1 LED( AL1 ) K. Power Supply
E. Green LED (Power indication) L. Rubber Cap
F. Reset Button M. Gas entry
G. Mode Button N. Buzzer
O. Green LED(Power indication) T. Enter Button
P. Red 1 LED (AL1 ) U. Mode Button
Q. Red 2 LED ( AL2) V. RJ45 Plug for
next RDU (Output)
R. Yellow LED ( Fault indication) W. RJ45 Plug for SEU( Input)
S. LCD display X. Buzzer
RDU, the four LED’s will blink and buzzer will sound on SEU & RDU., after that
the communication is ready, the content of display is same on SEU & RDU.
Mount the plug lock
9. Customizing Settings
When power has been connected, the SEU and RDU will begin to monitor the
CO2 concentration and the temperature. In order to the get the timely alarm safety
information and meet the personal requirements, It is advisable to set up the
customizing parameter when necessary.
Temperature ºC/ºF:
Using the DIAG function:
1. Press Mode until the “DIAG” icon flashes
2. Press Enter, the four LED’s will blink on the SEU and the buzzer will
sound
3. The four LED’s will blink and buzzer will sound simultaneously on
the RDU
Setting the First Alarm parameter:
1. Press Mode until the “AL1” icon flashes
2.Press Enter, the “AL1” icon shows on LCD
3. Press Mode to go through “ 0.5%,1%,1.5%,2%” alarm level
4. Press Enter again to save the setting after selection
Setting the Second Alarm parameter:
1. Press Mode until the “ AL2” icon flashes
2. Press Enter, the “AL2” icon shows on LCD
3. Press Mode to go through “1.5%,2%,2.5%,3%,3.5%,4%” alarm level
4. Press Enter again to save the setting after selection
Notes: The second alarm level should be higher than the first alarm level
when setting with the alarm level parameter.
Using the CALI function:
1. Press Mode until the “CALI” icon flashes
2. Press Enter, the “CALI” icon shows on the LCD
3. Press and hold Mode for at least 10 seconds. The “CALIBRATING”
icon will flash. The calibration will be done automatically. After 10
minutes the LCD will display “Pass” or “Fail”. If “Fail”, please try
again.
Notes: When do the calibration, it is suggested to take SEU outside, using
the ambient gas for calibration, waiting around 10 minutes until the CO2
reading of SEU doesn’t change, then use the 380-420 ppm as the
standard CO2 reading. Calibrating the unit according to “CALI” mode
instruction, user should not breathe toward to SEU during the calibration
process, as the CO2 from the user will affect the CO2 reading of SEU.
Using the ReFactSet function:
1. Press Mode until the “ReFactSet” icon flashes
2. Press Enter, and then press Mode to choose either “Yes” or “No”
3. Press Enter again to save the setting after selecting
Note: If the user sets the data or calibrates the sensor incorrectly, use the
ReFactSet (recover the factory Setting) to come back the default factory
setting.
10 .Specification
■CO2 & Temperature specification:
CO2 Specification
Measurement Range 0 - 50,000 ppm (5%) display
Display Resolution 10 ppm
Accuracy ±100 ppm or ±5% of reading, whichever is
greater
Repeatability ±20 ppm @400 ppm
Annual Drift <20 ppm/Year@400ppm
Temperature
Dependence ±0.2% of reading per °C or ±2 ppm per °C,
whichever is greater, referenced to 25°C
Pressure Dependence 0.13% of reading per mm Hg
Response Time <60 seconds for 90% response to step
change
AL1 (First Alarm Level) 0.5 / 1 / 1.5 / 2 % , DefaultAL1= 1.5%
AL2 (Second Alarm Level)
1.5 / 2 / 2.5/ 3 / 3.5 / 4 % , DefaultAL2= 3%
SoundAlarm 80db@10cm
Warm-Up Time <60 seconds at 22°C
Temperature Specification:
Temperature Range 0°C to 50°C (32°F to 122°F)
Display Resolution 0.1°C (0.1°F)
Display Options °C/°F
Accuracy ±1°C(±2°F) when CO2 concentration is
below first alarm level
Response Time 20-30 minutes (case must equalize with
environment)
Operating Conditions:
OperatingTemperature
0°C to 40°C ( 32°F to 104°F)
Humidity Range 0 ~ 95% RH non-condensing
Storage Conditions:
Storage Temperature -20°C to 60 °C (-4°F to 140°F)
■Power Supply & Relay Output:
Power Supply AC adapter 110/220 VAC
Voltage 100 ~ 240 VAC
Frequency 50 / 60 Hz
AC
Input
Power
Requirement
1 W maximum @ 115 VAC 60 Hz
2 W maximum @ 230 VAC 50 Hz
Voltage 6VDCAC/DC
Output
Power 1.8 W
Peak Input Current 0.3 Afrom 6 VDC
Relay Output 30 VDC or 250 VAC, max 2A, SPST,
Normally Open
11. Weight & Dimension
Weight: SEU (Sensor Unit): 459 g
RDU (Remote Display Unit): 130 g
Dimension:
12. Fault Codes &Troubleshooting Guide
This section includes a list of Frequently Asked Questions for problems you may
encounter with the ZG10U CO2 Monitor.
No LCD
Fault
Icon
Description
(of the fault) SEU
Indication
RDU
Indication
SuggestedActions
1 Er3
The ambient
temperature has
exceeded the
temperature
range 0°C to
50°C ( 32°F to
122°F)
“Er3” flash
Fault LED
blink,
Buzzer
beep
“Er3” flash
Fault LED
blink,
Buzzer
beep
This error will disappear
when the temperature
returns to the range
between 0°C and 50°C
( 32°F to 122°F)
2 Er4
some wrong
measurement or
the sensor has
exceeded its
expected life
“Er4” flash
Fault LED
blink,
Buzzer
beep
“Er7” flash
Fault LED
blink,
Buzzer
beep
Please unplug the AC
adapter and reconnect it. If
the “Er4” always appears,
please contact with the
local dealer.
3 Er5
Er6 EEPROM
System Problem
“Er5” &
“Er6”
flash,
Fault LED
blink,
Buzzer
beep
“Er7” flash
Fault LED
blink,
Buzzer
beep
Please unplug the AC
adapter and reconnect it. If
the “Er5,Er6” always
appear, please contact with
the local dealer.
4 Er7 Internal Data
Transmission
Error
“Er7”
flash,
Fault LED
blink,
Buzzer
beep
“Er7”
flash,
Fault LED
Blink,
Buzzer
beep
①Please unplug the AC
adapter and reconnected
it.
②Check the RJ45 plug is
connected into the INPUT
port of RDU,if the “Er7”
displays on the RDU only.
5 Er8
The accuracy of
CO2 sensor may
deviate from the
actual CO2
concentration.
“Er8” flash
Fault LED
blink,
Buzzer
beep
“Er8” flash
Fault LED
blink,
Buzzer
beep
①Please unplug the AC
adapter and reconnect it
If the “Er8” still appears,
please contact with the
local dealer.
②Please calibrate the unit,
after the calibration, If the
“Er8” still appears, please
contact with the local
dealer.
1. Press “Enter” to switch between ºC and ºF temperature
Radiant Innovation Inc. Http://www.ZyAura.com
1F, No.3, Industrial East 9th Road, Science-Based
Industrial Park, HsinChu, Taiwan 300.
SEU (Sensor Unit)
Inch
(
mm
)
RDU (Remote Display Unit)
Inch
(
mm
)
Ref.No.:032011