2N Access Unit M User manual

2N Access Unit M Installation
Manual
v.1.0
www.2n.com

2N Access Unit M Installation Manual
2 / 42
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Content
1. Product Overview
1.1 Components and Associated Products
1.2 Terms and Symbols
2. Description of Installation
2.1 Before You Start
2.2 Mechanical Installation
2.3 Electric Installation
2.4 Extending Module Connection
3. Detection of 2N Access Unit M using 2N® Network Scanner
4. Factory Reset
5. Maintenance
6. Status Signaling
7. Technical Parameters
7.1 General Drawings
8. Supplementary Information
8.1 General Instructions and Cautions
8.2 Troubleshooting
8.3 Directives, Laws and Regulations

2N Access Unit M Installation Manual
3 / 42
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1. Product Overview
Here is what you can find in this section:
1.1 Components and Associated Products
1.2 Terms and Symbols
Basic Features
2N Access Unit M is an elegant and reliable access IP system equipped with a number of useful
functions.
2N Access Unit M is a single-module access system available in several versions.
All the 2N Access Unit M versions include an integrated card reader module,which helps
control access using an RFID card. With additional software settings, you can use the card to
control more functions than just door lock switching too.
The 2N Access Unit M keypad versionhelps you control the electric lock switch by entering a
valid numeric code via the numeric keypad. With additional software settings, you can use the
numeric code to control more functions than just door lock switching too.
The 2N Access Unit M Bluetooth version helps you control the lock switch using the 2N®Mobile
Key application installed in your smartphone.
2N Access Unit M is designed as a robust, mechanically resistant IP55-rated access system,
which withstands any weather conditions without requiring additional accessories.
The installation of 2N Access Unit M is very easy. All you have to do is connect the system to
your LAN via a mains cable. Feed the access system either from a 12V power supply or your PoE
supporting LAN.
To configure 2NAccess Unit M use a PC equipped with any Internet browser. Use2N®Access
Commander to bulk manage extensive access system installations easily.
Advantages of Use
Elegant mullion design
Weather resistance (IP 55)
Easy wall (surface) mounting (brick/pasterboard walls, door frames)
Integrated electric lock switches with wide setting options
Integrated RFID card reader module
Bluetooth module version
Backlit touch keypad version
LAN (PoE) or external 12V power supply
Configuration using web interface
HTTP server for API configuration
SNTP client for time synchronization
SMTP client for email sending, Picture to Email feature

2N Access Unit M Installation Manual
4 / 42
•
•
•
•
•
•
•
•
•
TFTP/HTTP client for automated firmware and configuration upgrade and update
1.1 Components and Associated Products
Main Units
2N Part No.
916112
Axis Part No.
02393-001
2N®Access Unit M 13.56 MHz, NFC ready
is used for reading RFID cards in the 13.56 MHz bandwidth with the
NFC support. Combining an access reader and a controller, the
device is used for access control inside and outside of buildings.
The following RFID cards can be read:
ISO14443A (Mifare, DESFire)
PicoPass (HID iClass)
Felica
ST SR(IX)
2N®Mobile Key

2N Access Unit M Installation Manual
5 / 42
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Main Units
2N Part No.
916114
Axis Part No.
02394-001
2N®Access Unit M RFID 125 kHz, 13.56 MHz, NFC
is used for reading RFID cards in the 125 kHz and 13.56 MHz
bandwidths with the NFC support. Combining an access reader and
a controller, the device is used for access control inside and outside
of buildings.
The following RFID cards can be read:
EM4xxx
ISO14443A (Mifare, DESFire)
PicoPass (HID iClass)
Felica
ST SR(IX)
2N®Mobile Key
2N Part No.
916115
Axis Part No.
02395-001
2N®Access Unit M Bluetooth & RFID 125 kHz, 13.56 MHz, NFC
is used for reading RFID cards in the 125 kHz and 13.56 MHz
bandwidths with the NFC support. Combining an access reader, a
Bluetooth module and a controller, the device is used for access
control inside and outside of buildings.
The following RFID cards can be read:
EM4xxx
ISO14443A (Mifare, DESFire)
PicoPass (HID iClass)
Felica
ST SR(IX)
2N®Mobile Key

2N Access Unit M Installation Manual
6 / 42
•
•
•
•
•
•
•
•
•
•
•
Main Units
2N Part No.
916116
Axis Part No.
02396-001
2N®Access Unit M Touch Keypad & RFID 125 kHz, 13.56 MHz, NFC
is used for reading RFID cards in the 125 kHz and 13.56 MHz
bandwidths with the NFC support. Combining an access reader, a
touch keypad and a controller, the device is used for access control
inside and outside of buildings.
The following RFID cards can be read:
EM4xxx
ISO14443A (Mifare, DESFire)
PicoPass (HID iClass)
Felica
ST SR(IX)
2N®Mobile Key
License
2N Part No.
916012
Axis Part No.
01369-001
2N Access Unit NFC license
2N Part No.
9160401
Axis Part No.
02000-001
2N Access Unit Lift module license

2N Access Unit M Installation Manual
7 / 42
•
•
•
•
•
•
•
•
•
•
•
Electric Locks
Part No. 932071E BEFO 11211
12 V / 230 mA DC
low consumption
Part No. 932081E BEFO 11221 with momentum pin
12 V / 230 mA DC
low consumption
A very short electric pulse is enough to put the lock in the
OPEN position and unlock the door. After passage, the
lock gets in the CLOSED (relax) position again.
Part No. 932091E BEFO 11211MB with mechanical blocking
12 V / 230 mA DC
low consumption
You can set the lever mechanically into the OPEN or
CLOSED position. When OPEN, the lock is constantly
open, when CLOSED, it is a standard lock.

2N Access Unit M Installation Manual
8 / 42
•
•
•
•
•
•
•
•
•
•
•
•
•
Electric Locks
Part No. 932061E BEFO 11211MB with momentary pin, mechanical
blocking
low consumption
12 V / 230 mA DC
A regular lock with a built-in contact to indicate whether
the door is open or closed.
Part No. 932072EBEFO 31211
fail safe
12 V / 170 mA DC
The reverse lock is closed when electricity is switched
on. When electricity is interrupted, the lock is opened.
Part No. 932062E BEFO321211
fail-safe plus door signaling
12 V / 170 mA
The reverse lock is closed when electricity is switched
on. When electricity is interrupted, the lock is opened.
It contains a built-in contact to indicate whether the
door is open or closed.
•
Tip
FAQ: Electric locks – Differences between locks for 2N IP access systems

2N Access Unit M Installation Manual
9 / 42
•
•
•
•
•
•
•
•
•
•
Power Supply
Part Numbers
91378100E
91378100US
PoE injector – without cable
PoE injector –with EU cable
PoE injector – with US cable
For intercom supply via Ethernet cable where the PoE switch is absent.
Part Nos.
91341482E
91341482US
12 V / 1 A adapter
A stabilized power supply needs to be used where no PoE is available.
Part
No.932928
12 V transformer
for electric lock
Additional Modules
2N Part No.
9159010
Axis Part No.
01386-001
Security Relay
A handy add-on that significantly enhances door entry security
Prevents lock tampering. Installed between the intercom, from which
it is also supplied, and the lock to be controlled.

2N Access Unit M Installation Manual
10 / 42
•
•
•
•
•
Additional Modules
Part No. 9159013 Departure button
Connects the logic input for door unlocking from inside the building.
2N Part No.
9159012
Axis Part No.
01388-001
Magnetic door contact
Set for installation on a door, enabling the status of door opening to
be ascertained. Used when the intercom is used for door protection,
to detect when the door is not closed or forced open.
2N Part No.
9134173
Axis Part No.
01384-001
RFID card, Mifare Classic 1k, 13.56 MHz

2N Access Unit M Installation Manual
11 / 42
•
•
•
Additional Modules
2N Part
No.9134174
Axis Part No.
01385-001
RFID fob, Mifare Classic 1k, 13.56 MHz
2N Part
No.9134165E
Axis Part No.
01395-001
RFID card, type EM4100, 125 kHz
2N Part
No.9134166E
Axis Part No.
01396-001
RFID fob, type EM4100, 125 kHz

2N Access Unit M Installation Manual
12 / 42
•
•
•
•
•
•
•
•
•
Additional Modules
2N Part No.
9137420E
Axis Part No.
01399-001
External RFID card reader connectable to a PC via a USB
interface.
Suitable for system administration and adding of EM41xx cards (125
kHz) via a web interface or 2N® Access Commander.
2N Part No.
9137421E
Axis Part No.
01400-001
USB Reader of 13.56 MHz, 125 kHz RFID Cards and NFC/HCE
devices
External RFID card reader connectable to a PC via a USB interface.
Suitable for system administration and adding 13.56 MHz, 125 kHz
cards and Android platform devices supporting NFC/HCE using 2N IP
intercom web interface or 2N® Access Commander. It reads the
same types of cards and devices as card readers in2N IP intercoms.
13.56 MHz/ISO/IEC 14443AMifare Classic 1k & 4k, DESFire EV1,
Mini, Plus S&X, Ultralight, Ultralight C
13.56 MHz/ISO/IEC14443B CEPAS, HID iCLASS (CSN only)
13.56/JIS X 6319Felica
ISO/IEC 18092 SmartPhone with NFC/HCE support, Android
version 6.0 Marshmallow and higher (2N®Mobile Key required)
EMarine

2N Access Unit M Installation Manual
13 / 42
•
•
•
•
•
•
•
•
•
•
•
Additional Modules
2N Part No.
9137424E
Axis Part No.
01527-001
SecuredUSB Reader of 13.56 MHz, 125 kHz RFID Cards and NFC/
HCE devices
External secured RFID card reader connectable to a PC via a USB
interface. Suitable for system administration and adding 13.56 MHz,
125 kHz cards and Android platform devices supporting NFC/HCE
using the 2N IP intercom web interface or 2N® Access Commander.
It reads the same types of cards and devices as card readers in2N IP
intercoms.
13.56 MHz/ISO/IEC 14443AMifare Classic 1k & 4k, DESFire EV1,
Mini, Plus S&X, Ultralight, Ultralight C
13.56 MHz/ISO/IEC 14443B CEPAS, HID iCLASS (CSN or PAC ID)
13.56MHz/JIS X 6319Felica
ISO/IEC 18092 SmartPhone with NFC/HCE support, Android
version 6.0 Marshmallow and higher (2N®Mobile Key required)
EMarine
2N Part No.
9137410E
Axis Part No.
01397-001
External IP relay – 1 output
A stand-alone IP device, which can be controlled from an IP intercom
via HTTP commands, which can thus control devices on unlimited
distance.
2N Part
No.9137411E
Axis Part No.
01398-001
External IP relay – 4 outputs, PoE
A stand-alone IP device, which can be controlled from an IP intercom
via HTTPcommands, which can thus control devices on unlimited
distance.

2N Access Unit M Installation Manual
14 / 42
•
•
•
•
•
Additional Modules
Part No.
9159014EU/US/
UK
2N® 2Wire
(set of 2 adapters plus EU/US/UK power supply)
The 2N® 2Wire converter allows you to use the existing 2-wire cabling
from your original door bell or door intercom to connect any IP
device. You do not have to configure anything, all you need is one 2N®
2Wire unit at each end of the cable and a power supply connected to
at least one of these units. 2N® 2Wire then provides PoE power not
only to the second converter, but also to all the other IP end devices
connected.
2N Part No.
9160501
Axis Part No.
0820-001
AXIS A9188 Network I/O relay module
Lift control relay module for up to 8 floors

2N Access Unit M Installation Manual
15 / 42
1.2 Terms and Symbols
The following symbols and pictograms are used in the manual:
•
Tip
Refer to the local 2N distributor for more accessories and recommendations
please.
•
Safety
Always abide by this information to prevent persons from injury.
•
Warning
Always abide by this information to prevent damage to the device.
•
Caution
Important informationfor system functionality.
•
Tip
Useful informationfor quick and efficient functionality.
•
Note
Routines or advice for efficient use of the device.

2N Access Unit M Installation Manual
16 / 42
•
•
•
•
2. Description of Installation
Here is what you can find in this section:
2.1 Before You Start
2.2 Mechanical Installation
2.3 Electric Installation
2.4 Extending Module Connection
2.1 Before You Start
Before starting the installation, please check whether your2NAccess Unit Mpackage complies
with the following list.
Package complies with the following list.
1x 2N Access Unit M
1x Wall holder (screwed to the device)
2x 8 mm dowel
2x Screw with a washer
1x Screw for fitting the device in the holder
1x Torx key (10/20 size)
1x Certificate of ownership
1x Brief Manual
2.2 Mechanical Installation
2N Access Unit M is designed for surface mounting (wall, plasterboard, door frames).
Use the drilling template shown on the device
box to prepare holes of the required sizes for
cabling and dowels on the selected place in
the required height.Feed the cables out of
the pre-predrilled hole.
Loosen the screws to
unscrew the holder
from the device
backside and slide the
holder downwards.
Then fit the
holder through
the dedicated
holes using the
Interconnect the fed-out cables with the 2N Access Unit
Mcabling. Put the device carefully on the installed
holder from above downwards and fix its position on the

2N Access Unit M Installation Manual
17 / 42
screws
enclosed.
holder carrying elements by tightening the screw from
the bottom through the holder hole.
2.3 Electric Installation
2NAccess Unit Mcan be fed either from an external 12 V / 1 A DC power supply or from a PoE
802.3af supporting LAN.
External power supply
Use a 12 V ± 15 % SELV supply dimensioned to the current consumption required for the access
unit power output to make your device work reliably.
Current consumption
[A]
Available power output
[W]
1 12
PoE Supply
2N Access Unit M is compatible with the PoE 802.3af (Class 0–12.95 W) technology and can be
supplied directly from the LAN via compatible network elements. If your LAN does not support
this technology, insert a PoE injector, Part No. 91378100, between 2N Access Unit M and the
nearest network element. This power supply provides
2N Access Unit M with 12 W for its own feeding.
Combined power supply
2N Access Unit can be fed from an external power supply and PoE at the same time. In this
configuration, the maximum supply power is available.
•
Tip
The external power supply can also be used a PoE switch failure backup making
the unit constantly functional.

2N Access Unit M Installation Manual
18 / 42
Connection to LAN
2N Access Unit M is connected to the LAN using a UTP/STP cable (category Cat-5e or higher) via
the dedicated LAN connector. As the device is equipped with the Auto-MDIX function, you can
use both the straight and crossed cable version.

2N Access Unit M Installation Manual
19 / 42
•
•
Caution
We recommend the use of a LAN surge protection.
We recommend the use of a shielded SSTP Ethernet cable.

2N Access Unit M Installation Manual
20 / 42
Status Power Consumption
[W]
91611
2
91611
2-S
916114 91611
4-S
916115 916115-
S
91611
6
916116-S
At relax 1.6 W 1.8 W 1.5 W 1.7 W 1.5 W 1.7 W 1.5 W 1.7 W
LED –white strip
100 %
0.12
W
0.12
W
0.12 W 0.12
W
0.12 W 0.12 W 0.12
W
0.12 W
LED –green strip
100 %
0.15
W
0.15
W
0.15 W 0.15
W
0.15 W 0.15 W 0.15
W
0.15 W
LED –red strip 100
%
0.20
W
0.20
W
0.20 W 0.20
W
0.20 W 0.20 W 0.20
W
0.20 W
LED –Bluetooth
100 %
– – – – 0.06 W 0.06 W – –
LED –keypad
backlight 100 %
– – – – – – 0.15
W
0.15 W
Standard room
temperature mode
0.14
W
0.14
W
0.14 W 0.14
W
0.14 W 0.14 W 0.14
W
0.14 W
OUT1 at maximum
possible load
6 W 6 W 6 W 6 W 6 W 6 W 6 W 6 W
Audio 0.7 W 0.7 W 0.7 W 0.7 W 0.7 W 0.7 W 0.7 W 0.7 W
Other manuals for Access Unit M
1
Table of contents