Abbey Topcat TC0 User manual

Models TC0, TC1 and TC3
Installation Guide

Mounting
Mount Topcat against a flat surface using four M5 screws.
Screw Spacing Outside Dimensions
Model Horizontal (A) Vertical Width (B) Height
TC0 89.5 mm 141 mm 112 mm 168 mm
TC1 121.5 mm 141 mm 143 mm 168 mm
TC3 184.5 mm 141 mm 206 mm 168 mm
B
A
141 mm
168 mm
Mounting Template
Powering
Voltage Range Rating
11~36V DC 1.5A @ 12V DC 0.75A @ 24V DC
DC Supply & External Load
+
-
11-36VDC
POWER
11-36V DC
SUPPLY
+
12V SW
12V LOAD
An external power option can be installed in Topcat that can provide a switched
13.8V supply up to 1A through pins 2 and 3 of the power connector as shown. This
can be used to power an external device such as a cellular modem.
Connect an antenna before powering up Topcat
Depth is 125mm, plus front clearance for
wiring (at least 70mm for antenna jack)
Installation Guide 1 IG-671-2.2-2015-Mar

Isolated Digital Inputs
General Description Inactive, LED off Active, LED on Maximum Resistance
Positive voltage-activated 0~+1.8V +4.5~36.0V ±60V DC 12kΩ to GND
COM
-VE
D.INs
Digital Inputs
COM
-VE
1
0
8
9
DRY
CONTACTS
(EG. RELAY
CONTACTS
SWITCHES)
FIELD
SUPPLY
Inputs 0~3 can be used for Pulse Counts. Max count rate <= 50Hz
Analog Inputs
General Description Inactive, LED off Active, LED on Maximum Resistance
Positive 4~20mA current 0~+4mA +4~20mA ±5V ±40mA 120Ω to GND
GND
A.INs
4~20 mA
TRANSDUCERS
Analog Inputs
3
1
2
0
FIELD
SUPPLY
IG-671-2.2-2015-Mar 2 Installation Guide

Isolated Digital Outputs
Normally open contacts which close to COM rated at 6A for 230V AC and 30V DC.
COM
3
1
2
0
4
5
D.OUTs
Digital Outputs
COM
LOAD
LOAD
6 A MAX
PER OUTPUT
FIELD
SUPPLY
Security I/O
The fail-safe alarm is an open collector, which can carry 50mA, up to 30V, and can
drive a relay coil directly.
INHIBIT
TAMPER
ALARM
GND
Door Switch
Key Operated
Switch
Fail-safe
Alarm
(see text)
Security I/O
SECURITY I/O
Installation Guide 3 IG-671-2.2-2015-Mar

Serial Ports
Name Type Socket Typically used for…
PORT 1 RS-232 RJ-45(1) Local connection to PLC, data logger, meter
PORT 2 RS-232 RJ-45 Local connection to PLC, data logger, meter
CONFIG RS-232 RJ-45 Laptop, Analog output module
(1) Connector pins 2 and 3 are not connected on PORT 1.
(2) The +12V outputs can power small loads such as serial
converters.
Each port has a red/green LED indicator, which blinks green
when Topcat receives a valid message. Red indicates an error
condition.
Ethernet Port
This is a standard 100-base-T Ethernet port, which is operational when the
appropriate firmware is installed.
External Radio Connections
These connections are applicable only when no internal radio is fitted.
1
8
RJ45 Pins
Always use best radio-frequency engineering
practices for all radio and antenna installation.
Dir Name
1 sf
+12V(2)
2(1)
sf
COut2
3(1)
sf
CIn2
4 sf
COut1
5 sf
CIn1
6 sf
TxD
7 sf
RxD
8 GND
Pin Dir Name
1 GND
2 sf PTT
3 sf Channel Busy
4 sf Tx Audio
5 sf Rx Audio
6 sf Serial TxD
7 sf Serial RxD
8 GND
Serial ports can be permanently damaged if an
Ethernet cable is plugged into them.
Connect an antenna before powering up Topcat
IG-671-2.2-2015-Mar 4 Installation Guide

Speaker / Microphone Connections
A suitable Speaker / Microphone connection is provided on units with an internal
radio for monitoring and testing the radio channel.
1
6
RJ12 Speaker Mic Pins
Communication Indicators
The COMMS indicators show communication between Topcat and the Telemetry
Master.
Indicator Indication Meaning
VAD/COMMS
Green short blink A valid message for a different RTU was received
Green long blink A valid message for this RTU was received
Red Comms fail (no comms with the Master)
CHAN BUSY Yellow The radio transceiver is receiving RF on it’s channel
RX DATA Yellow Shows the data being received by Topcat
PTT Yellow Topcat is transmitting on the radio channel
TX DATA Yellow Shows the data being transmitted by Topcat
A short blink is about 0.1 seconds. A long blink is about 0.5 seconds.
Ready LED and Reset
Ready LED indication swampfox operating state
Green Normal
Topcat is operating normally
Red Defect Hardware or firmware fault
The RESET button is behind a small unmarked hole in the front panel near the
DISPLAY button. To reset and restart Topcat, press RESET briefly.
Other Front Panel Items
The COMMS LED illuminates red when Topcat cannot communicate with a master.
The DISPLAY button turns the front panel indicators on and off. The ready LED is
always enabled.
The ADDRESS SWITCHES set Topcat’s three digit RTU address.
Pin
Name
1 N/C
2 Speaker
3 PTT
4 Microphone
5 GND
6 GND
Topcat only examines the address
switches when it starts up or is reset
Installation Guide 5 IG-671-2.2-2015-Mar

Notes
IG-671-2.2-2015-Mar 6 Installation Guide

Copyright © 2006-2015 Abbey Systems Ltd
www.abbey.co.nz
support@abbey.co.nz
Level 3, 220 Willis Street
PO Box 27-497
Wellington, New Zealand
Phone +64-4-385-6611
Fax +64-4-3856848
Document number IG-671-2.2-2015-Mar
Products Covered TC0, TC1 and TC3 (all variants)
Revision Number 2.2
Revision date 15 March 2015
Topcat and the logo are trademarks of
Abbey Systems Ltd, registered with the U.S. Patent and Trademark Office.
This manual suits for next models
2
Table of contents