Index
1 INTRODUCTION ........................................................................................................................................... 3
1.1 ESMGS8-C2-B INTRODUCTION ............................................................................................... 3
1.2 FEATURES .................................................................................................................................... 3
1.3 SPECIFICATIONS ........................................................................................................................ 3
2 PANEL VIEWS .............................................................................................................................................. 5
2.1 Front panel view ............................................................................................................................ 5
3 DIMENSIONS(UNIT=mm) ........................................................................................................................... 7
4 MOUNTING ................................................................................................................................................... 8
4.1 DIN mounting ................................................................................................................................. 8
4.2 Wall mounting ................................................................................................................................ 8
4.3 Items for attention ......................................................................................................................... 9
4.4 Grounding ....................................................................................................................................... 9
5 Cable ............................................................................................................................................................. 11
5.1 Ethernet cable .............................................................................................................................. 11
5.2 SFP port ........................................................................................................................................ 12

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 3 of 13
1 INTRODUCTION
1.1 ESMGS8-C2-B INTRODUCTION
ESMGS8-C2-B is a managed PoE/PoE+ Industrial Ethernet switch with 8*10/100/1000M
auto sensing electrical ports and 2 *1000M Comb ports. The switch supports PoE/PoE+.
Each of the 8 electrical port outputs up to 30W. The switch supports Ethernet Ring
Protection Switching (ERPS) as well as STP/RSTP/MSTP. It also supports Web-based
network management, VLAN, QoS, SNMP, IGMP snooping etc. Rugged design with IP40
enclosure and industrial level 3 protection makes it suitable for applications such as
Intelligent Transportation System, IP surveillance and industrial networks.
1.2 FEATURES
− 8* 10/100/1000Base-T Ethernet ports (PoE)
− 2 Gigabit Comb ports
− Support EPRS (typical recovery time < 30ms with 250 units of connection)
− Support different redundancy protocols and standards STP / RSTP / MSTP
− Support SNMPv1/v2c/v3 & RMON & Port base/802.1Q VLAN network
management
− Support IGMP Snooping multicast function
− Support WEB, Telnet, SSH, Console (CLI)
− Support open and close port, binding MAC and port
− Support 802.1x network access control
− Support 802.1Q protocol, Isolate network flow
− Support Radius Centralized password management
− Support IEEE802.3af/at standard
− Overload current protection and reverse polarity protection
− IP40 enclosure protection
− Unique DIN mount design makes mount and removal easy
− Both POE and Non-POE models are available
1.3 SPECIFICATIONS
Ethernet
10/100/1000Base-T 8
1000Base-FX SFP 2 (Comb ports)
PoE standard IEEE802.3af/at

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 4 of 13
Switching Performance
Architecture Store and Foreword
Bandwidth 24Gbps
Power
Redundant Input Power Dual DC inputs. 45~57VDC, 5-pin screw terminal
Power Consumption (Max.) < 10W (Without PoE output)
PSE type End Span
POE Port Each port up to 30W
Overload Current Protection Present
Reverse polarity protection Present
Mechanical
Enclosure IP40
Dimension (W x D x H) 68mm (W) x 105mm (D) x 146mm (H)
Weight 0.9kg
Environment
Storage Temperature -40 to +85oC (-40 to 185oF)
Operating Temperature -40 to +75oC (-40 to 167oF)
Operating Humidity 5% to 95% Non-condensing

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 5 of 13
2 PANEL VIEWS
2.1 Front panel view
1. 45~57VDC power input
2. Alarm output terminal block (one is normal open and the other is normal close)
3. USB console
4. PWR, Alarm and Run status indication
5. Ground screw
6. 10/100/1000Base-T port: #1 ~ #8
7. Comb port: #9 ~ #12
8. Ring status indication
WARNING:This product MUST be mounted to a well-grounded mounting
surface such as a metal panel.
Status indicator LED
LED Color Status Description
Run Green On System running lights, the
system normally solid
green
Alarm Green On Warning lamp

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 6 of 13
P1 Orange
On Power 1 is being supplied
Off Power 1 is not being supplied
P2 Orange
On Power 2 is being supplied
Off Power 2 is not being supplied
PoE1-8 Green On The corresponding port’s PoE power on
Off The corresponding port’s PoE power off
Comb port
LINK Green On Port connected
ACT Orange
Blinking
Data is being transmitted
10/100/1000Base-T(X)
SPD Green On Speed indicator for 1000Mbps
Off Speed indicator for 100Mbps and 10Mbps
LINK/ACT
Orange
On The corresponding port’s link is active
Blinking
Data is being transmitted
Off The corresponding port’s link is inactive

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 7 of 13
3 DIMENSIONS (UNIT=mm)

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 8 of 13
4 MOUNTING
4.1 DIN mounting
Very simple: Press the clamp, insert into rail then loosen hand
4.2 Wall mounting
Step 1 Step 2

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 9 of 13
Step 3 Step 4
Step 1: Remove the guide rail fastener;
Step 2: Remove the DIN clamp in the rear panel;
Step 3: Find the wall mounting accessory, and loosen these 4 screws in the Switch.
Step 4: Mounting the accessory on the rear panel;
Step 5: Fixed the switch on the wall.
4.3 Items for attention
− Operating Ambient: If the product is installed in a closed rack, the inside operating
ambient temperature of the rack may be higher than outside. Therefore,
consideration should be given to installing the equipment in an environment
compatible with the maximum operating temperature specified by the manufacturer.
− Air Flow: Installation of the equipment in a rack should be such that the amount of
air flow required for safe operation of the equipment is not compromised.
− Circuit Overloading: Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might
have on overcurrent protection and supply wiring.
− Reliable Earthing: Reliable earthing of rack-mounted equipment should be
maintained. Particular attention should be given to supply connections other than
direct connections to the branch circuit (e.g. use of power strips).
4.4 Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 10 of 13
interference (EMI). Run the ground connection from ground screw to the grounding
surface prior to connecting devices.

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 11 of 13
5 Cable
5.1 Ethernet cable
The product uses standard Ethernet cable. Depending on the connection type, you can choose
CAT3, 4, 5e, 6 UTP cable to connect to other network devices (computers, servers, switches, routers,
hubs, etc.). Make sure that the cable properties in the following form.
cable type Max length connector
10BASE-T Cat.3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat.5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-TX Cat.5/Cat.5e/6 100-ohm UTP UTP 100 m (328ft) RJ-45
100BASE-TX / 10BASE-T Pin Allocation
100BASE-TX / 10BASE-T Cable, pins 1 and 2 to send data, receive data pin 3,6
10/100Base-T RJ-45 Pin Definition
Pin Number signal POE
1 TD+ POE+
2 TD- POE+
3 RD+ POE-
4 null
5 null
6 RD- POE-
7 null
8 null
1000Base-T RJ-45 Pin Definition
Pin Number signal POE
1 BI_DA+ POE+
2 BI_DA- POE+
3 BI_DB+ POE-
4 BI_DC+
5 BI_DC-
6 BI_DB- POE-
7 BI_DD+
8 BI_DD-
This switch supports MDI / MDIX auto-flip function. The following table lists the10/100Base-T MDI/MDI-X
/ 1000Base-T MDI/MDI-X port pin output.
10/100Base-T MDI/MDI-X pin definition
Pin definition MDI port MDI-X port POE
1 TD+(transmit) RD+(receive) POE+

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 12 of 13
2 TD-(transmit) RD-(receive) POE+
3 RD+(receive) TD+(transmit) POE-
4 Not used Not used
5 Not used Not used
6 RD-(receive) TD-(transmit) POE-
7 Not used Not used
8 Not used Not used
1000Base-T MDI/MDI-X pin definition
Pin Number MDI port MDI-X port POE
1 BI_DA+ BI_DB+ POE+
2 BI_DA- BI_DB- POE+
3 BI_DB+ BI_DA+ POE-
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB BI_DA- POE-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
5.2 SFP port
SFP port supports both electrical and optical SFP modules. Selecting right SFP modules (rate,
MM/SM, 1 fiber/2 fibers) based on application. Please notice that 1000M SFP port supports 1000Mbps
only.

ESMGS8-C2-B Quick Start Guide
ESMGS8-C2-B Quick Start Guide-Rev1709.docx www.kbcnetworks.com
Copyright © KBC Networks Ltd. 2017
Page 13 of 13
Need Help?
Please visit our website http://www.kbcnetworks.com or contact your nearest KBC
office or dealer.
KBC Networks Office Contact Information
North & Latin America, USA
Phone: +1 949 297 4930
Toll-free: +1 888 366 4276
Email: techsupport@kbcnetworks.com
EMEA, UK
Phone: +44(0)1322 312090
APAC
China
Phone (1): +86 25 5882 1665
Phone (2): +86 25 5882 1656
Email: techsupport@kbcnetworks.com
Singapore
Phone: +65 9747 5123
Email: apactechsupport@kbcnetworks.com
Table of contents
Other KBC Switch manuals

KBC
KBC ESUL5P-D User manual

KBC
KBC ESULS8-P2-B User manual

KBC
KBC ESML8P-PC2 User manual

KBC
KBC ESUL4-FL1 Series User manual

KBC
KBC ESUGS4-P1-B User manual

KBC
KBC ESUL8P-PC2-D User manual

KBC
KBC ESUGS4-EG1-P1-D User manual

KBC
KBC ESUL8-D Series User manual

KBC
KBC ESMGS8-P4-B Series User manual

KBC
KBC ESML6-FL2-M2 User manual