ACTpro IOM Input / Output Module
Product Overview
This is an 8 Input and 8 Output device that allows
an ACT controller to be used in applications where
signalling to other equipment is required. Examples
of this are elevator control, alarm systems, CCTV
switching applications, I/O Mapping etc.
Main Features
8 form C 5 Amp relays
8 supervised inputs
Tamper protection
2 status LEDs
Polycarbonate housing
Input and output names
Timer for each output
Output switched off or on by log
event, input, timezone
ACTWin pro support
Inputs and outputs Logged
Normally open/closed
Inputs monitored by timezone
Supervised Inputs option
Installation / Specification Guidelines
Up to 4 ACTpro IOMs may be connected
to each ACT controller bus, giving control
of up to 32 inputs and 32 outputs for each
controller
The controllers may be networked via RS485
or TCP/IP to control up to 1000 inputs and
1000 outputs maximum
The device may be installed indoors only
and requires +12V DC
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
ACTpro IOM module requires a 12 volts DC supply
ACTpro IOM System Schematic
ACTpro IOM
LAN / Ethernet
Database
Server
IOM
8
8
3000
100
IOM
8
8
2000
100
IOM
8
8
3000
100
200 200200
ACTpro IOM Input / Output Module
Product Specification
Operating Voltage: 12 Volts DC
Current Consumption: 300 mA
Weight: 375 grams
Operating Temperature: -10 to +50 C
Dimensions (HxWxD): 110 x 190 x 60 mm
Mounting: Surface
Installation: Indoor
Cabling Chart
From To Cable Restriction
Ordering Information
ACTpro IOM
Reader
ACTpro
100/200
Controller
Controller
Network
RS485
interface
Controller
Controller
Controller
PC Direct
RS232
Network
RS485
interface
PC
Twisted
screen
pair
or Cat 5
8 core
screen
Twisted
screen
pair
or Cat 5
Twisted
screen
pair
or Cat 5
Twisted
screen
pair
or Cat 5
Cable
Supplied
Maximum
1.4km
30m at 5volts
100m at
12volts
Maximum
1.4km
Maximum
30m
Maximum
1.4km
Maximum
30m
Access Control Technology Unit C1, South City Business Park, Tallaght, Dublin 24, Ireland.
t: 353 (0) 1 466 2570. f: 353 (0) 1 452 0427. e: [email protected]. w: www.accesscontrol.ie
I/O Module
Controller
ACTpro IOM
ACTpro 3000/2000
ACTpro IOM Applications
Elevator control
In this application, a user presents a card to the proximity reader when they
enter the cab. This enables the buttons for the floors to which the user has
access. The buttons stay on for a programmable amount of time (normally
7 seconds) and then switch off. When the user selects the floor, the buttons
turn off.
Alarm Systems
The unit can be programmed to activate a relay on alarm events such as
tamper, door forced, mains fail etc. It can also monitor the status of certain
inputs and switch an output when the input changes state. All changes are
fully logged in ACTWin pro complete with timestamp.
Building Management
The ACTpro IOM allows ACT controllers to be used in building management
applications. It can switch an output to turn on heating or lighting at certain
times or only when someone is present. It can also switch off heating when
the last person has left the room, saving on energy costs.
CCTV systems
Using an ACTpro IOM allows switching of CCTV cameras when someone
enters a room or when access is denied. When used in combination with
the Challenge feature of ACTWin pro, the image on the camera may be
compared against a pre-stored photo.
ACTpro IOM
ACTpro 3000/2000 ACTpro 100
Door Expander
ACTpro 200
2 Door Expander

Other manuals for ACTPRO IOM

2

Other ACT I/O System manuals

ACT ACTPRO IOM Quick guide

ACT

ACT ACTPRO IOM Quick guide

ACT ACTPRO IOM Quick guide

ACT

ACT ACTPRO IOM Quick guide

Popular I/O System manuals by other brands

Allen-Bradley Series B installation instructions

Allen-Bradley

Allen-Bradley Series B installation instructions

SMC Networks EX600-WEN Operation manual

SMC Networks

SMC Networks EX600-WEN Operation manual

Autonics ARD-D Series manual

Autonics

Autonics ARD-D Series manual

NI 9228 Getting started guide

NI

NI 9228 Getting started guide

Siemens APACS+ Installation and service instruction

Siemens

Siemens APACS+ Installation and service instruction

Festo CPX-AP-I-4DI4DO-M12-5P Instructions and Operating

Festo

Festo CPX-AP-I-4DI4DO-M12-5P Instructions and Operating

Acromag BusWorks 900MB Series user manual

Acromag

Acromag BusWorks 900MB Series user manual

ICP DAS USA DGW-521 user manual

ICP DAS USA

ICP DAS USA DGW-521 user manual

OleumTech WIO RM1K Wiring diagrams

OleumTech

OleumTech WIO RM1K Wiring diagrams

INVT IVC3 Series user manual

INVT

INVT IVC3 Series user manual

Rockwell Automation Allen-Bradley IF2 installation instructions

Rockwell Automation

Rockwell Automation Allen-Bradley IF2 installation instructions

LUTZE DIOLINE 20 operating instructions

LUTZE

LUTZE DIOLINE 20 operating instructions

jablotron JA-68 user manual

jablotron

jablotron JA-68 user manual

SeaLevel VERSA COMM +4 user manual

SeaLevel

SeaLevel VERSA COMM +4 user manual

National Instruments NI 6738 CALIBRATION PROCEDURE

National Instruments

National Instruments NI 6738 CALIBRATION PROCEDURE

Measurement Computing miniLAB 1008 user guide

Measurement Computing

Measurement Computing miniLAB 1008 user guide

M-system R8-SS4NJ instruction manual

M-system

M-system R8-SS4NJ instruction manual

ICP DAS USA tM-R5 quick start guide

ICP DAS USA

ICP DAS USA tM-R5 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.