adstec MMD9016 User manual

Instruction manual
Machine Mounted Displays
MMD9016
Translation of the original
instruction manual
Version 1.3
Updated on 2021-04-20

MMD9016 −Instruction manual v1.3 2
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
Read these instructions carefully before using and store for future reference. These instructions
contain important information about the product, in particular about its intended use, safety,
installation, utilisation, maintenance and disposal.
Hand over the instructions to the user following installation of the product, and pass the manual
on to the new user if the product is resold.
These instructions can be downloaded from: www.ads-tec.de in the download area.
Publisher
ads-tec Industrial IT GmbH
Heinrich-Hertz-Straße 1
72622 Nürtingen
Phone: +49 7022 2522-0
Internet: www.ads-tec.de
E-mail: mailbox@ads-tec.de

MMD9016 −Instruction manual v1.3 3
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
Contents
1General information about documentation...............................................................................4
1.1 General information 4
1.2 Explanation of safety instructions 4
1.2.1 Structure of safety instructions 4
1.2.2 Explanation of signal words 5
1.3 Relevant device documentation 6
1.4 Symbols 6
1.5 Data, figures and modifications 6
1.6 Trademarks 6
1.7 Copyright 7
2General device information ......................................................................................................8
2.1 Manufacturer and contact details 8
2.2 Intended use 8
2.3 Improper use 8
2.4 Environmental conditions 10
2.5 Conformity 11
2.6 Warranty / repairs 11
2.7 Limitation of liability 11
3Scope of delivery....................................................................................................................12
4Interfaces...............................................................................................................................13
4.1 Interface overview 13
4.1.1 Power supply 14
4.1.2 Earthing concept 14
5Mechanical installation ..........................................................................................................15
5.1 Requirements 15
5.2 Attaching flange seal 16
5.3 Securing to VESA interface 17
5.4 Securing using tube adapter 19
5.4.1 Attachment variants 19
5.4.2 Attaching tube adapter 20
5.4.3 Screwing adapter to retaining tube 21
6Commissioning.......................................................................................................................22
7Cleaning.................................................................................................................................23
8Disposal .................................................................................................................................23
9Dimensional drawings ............................................................................................................24
10 Technical data........................................................................................................................27
11 Service & support...................................................................................................................28
11.1 ADS-TEC support 28
11.2 Company address 28

MMD9016 −Instruction manual v1.3 4
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
1 General information about documentation
1.1 General information
This instruction manual is intended to ensure safe and efficient handling of MMD9016 industrial
monitors – referred to below as "device".
All of the safety instructions and handling instructions given in the manual must be obeyed in order to
ensure that work is carried out safely.
All users must read this instruction manual and have access to it at all times.
The original version of this instruction manual was written in German. All non-German versions of this
instruction manual are translations of the German instruction manual.
1.2 Explanation of safety instructions
1.2.1 Structure of safety instructions
The signal word classifies the hazard.
Reference to the type/consequences and source of the hazard is made underneath the signal word.
Information on how to avoid the hazard is indicated by an arrow ().
DANGER
Type and source of the hazard!
Possible consequences if the hazard is disregarded
Measures for avoiding the hazard

MMD9016 −Instruction manual v1.3 5
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
1.2.2 Explanation of signal words
DANGER
Indicates an imminent danger. If not avoided, death or severe injury will
result.
WARNING
Indicates a possible danger. If not avoided, death or severe injury could
result.
CAUTION
Indicates a possible danger. If not avoided, light or minor injuries could
result.
ATTENTION
Indicates a possibly damaging situation. If not avoided, the system or something in its
surroundings could be damaged.
Recommendation for use:
Indicates terms and/or conditions that strictly need to be observed to ensure
optimised and/or zero-defect operation. Tips and suggestions for the efficient use
of the device and software optimisation are also provided.

MMD9016 −Instruction manual v1.3 6
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
1.3 Relevant device documentation
The following documents are decisive to device setup and operation:
•This instruction manual:
contains information for installation, commissioning and operation of the device along with
technical data.
•Website:
You can download the instruction manual as well as drivers, software, user manuals, leaflets
and flyers from the Download area of our website www.ads-tec.de.
1.4 Symbols
Symbol Meaning
Label on batteries. The batteries may not be disposed of with household waste, but must
rather be disposed of separately. Used batteries must be returned to the point of sale or a
disposal system.
Label on electrical and electronic devices. Electrical and electronic devices must not be
disposed of with household waste, but must rather be taken to a collection point for waste
electrical equipment. Such a collection point is generally operated by public waste
management authorities, i.e., by municipalities.
Symbol for functional earth connection (FE)
1.5 Data, figures and modifications
All data, text and figures were prepared to the best of our knowledge. They do not represent any
assurance for the properties themselves. Despite taking utmost care, no liability can be assumed for
accuracy, completeness and actuality of the information. Subject to changes.
1.6 Trademarks
It is noted that any software and/or hardware trademarks and any company brand names mentioned in
this documentation are all subject to the general trademark protection rights.
Big-LinX®and X-Remote®are registered trademarks of ADS-TEC.
All other third-party trademarks used are hereby acknowledged.
In the case of infringement of trademark rights, ADS-TEC reserves the right to exercise all rights.

MMD9016 −Instruction manual v1.3 7
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
1.7 Copyright
This instruction manual is protected by copyright. For the authorised user, simple usage rights are
granted within the scope of the intent of the contract. Any modified use or exploitation of the provided
content, particularly duplication, modification or publishing in whatever form is permitted only with the
prior consent of ADS-TEC. In the case of copyright infringement, ADS-TEC reserves the right to
exercise all rights.

MMD9016 −Instruction manual v1.3 8
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
2 General device information
2.1 Manufacturer and contact details
The manufacturer of the device is ads-tec Industrial IT GmbH. The company is referred to in the
following as ADS-TEC.
ads-tec Industrial IT GmbH
Heinrich-Hertz-Str.1
72622 Nürtingen
Germany
Phone: +49 7022 2522-0
Email: mailbox@ads-tec.de
Web: www.ads-tec.de
2.2 Intended use
The control system is designed for use in the pharmaceutical, food, beverage and chemical industries. It
was specially developed for the hygiene sector. The device is used for the visualisation and control of a
wide range of processes on systems and machines in various application environments.
The device is only to be assembled, installed and operated within the permissible specifications. Use in
non-specified environments is prohibited.
2.3 Improper use
Operation other than or beyond that described for the device shall be deemed improper use.
The device is not allowed to be used to control vehicles or for applications for which further approvals
beyond the manufacturer's declaration are necessary (e.g. applications with explosion hazard, medical
technology and shipping industry).
The device must not be put into operation in the case of transport damage or nonconformity with the
specifications and must be taken out of operation in the case of changing conditions.
In the case of improper use, ADS-TEC shall not accept responsibility or liability for injury or damage that
is directly or indirectly attributable to the handling of the device.
If the device is opened up by an unauthorised person, the user may be subject to hazards and the
warranty is invalidated.
Should the device have evident signs of damages caused, e.g., by improper operation or storage
conditions or due to improper use or handling, it must be shut down immediately. Ensure that it is
secured against being started up accidentally.

MMD9016 −Instruction manual v1.3 9
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
The device can be damaged as a result of unauthorised mechanical modifications. Make sure that the
device is not drilled, chiselled or perforated and its exterior shape and design is not modified in any way!

MMD9016 −Instruction manual v1.3 10
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
2.4 Environmental conditions
The device can be operated under the environmental conditions specified in the technical data. Failure
to observe any one of these conditions will invalidate the warranty of the device. ADS-TEC cannot be
held liable for any damages arising from improper use and handling.
The device was developed in accordance with the directives of the European Hygienic Engineering &
Design Group (EHEDG):
−easy to clean
−easy to maintain
−high durability of the materials used
If, however, the device is to be used in aseptic environments, a suitability test must be conducted
and, where necessary, the manufacturer consulted.
ATTENTION
Damage caused by heat!
If the device is installed in a panel, casing or similar, heat accumulation can occur.
Make sure that heat can be dissipated from the device!
ATTENTION
Damage caused by condensation!
If the temperature of the device is different to that of the environment in which it is located,
condensation can form.
Switch on the device only after it has acclimated to the ambient temperature!
ATTENTION
Damage caused by heat!
If the device is exposed to sunlight or any other light or heat source, it can overheat and suffer
damage.
Do not expose the device to direct radiation by sunlight or any other light or heat source!

MMD9016 −Instruction manual v1.3 11
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
2.5 Conformity
The manufacturer hereby declares that the product described in this instruction
manual complies with all relevant stipulations of the following European directives:
•2011/65/EU, RoHS Directive
•2014/30/EU, EMC Directive
•2014/53/EU, RED Directive
•2014/35/EU, Low Voltage Directive
The device is a class A device (industrial sector). Class A may cause interference when used in
residential environments.
The EU conformity declaration can be requested on our website www.ads-tec.de and downloaded in the
Download area.
2.6 Warranty / repairs
During the device warranty period, any repairs must only be performed by the manufacturer or by
service personnel that has been authorised by the manufacturer.
2.7 Limitation of liability
ADS-TEC shall not be liable for personal injury, property damage or damage caused to the device as
well as consequential damage that is/was the result of non-compliance with this instruction manual,
improper use of the device, repairs and other actions on the device by unqualified electricians and
electricians not certified by ADS-TEC, or that is/was the result of using unapproved replacement parts.
Failure to observe the maintenance intervals shall also result in exclusion from liability. Furthermore, it is
strictly forbidden to make any unauthorised alterations or technical modifications to the device.

MMD9016 −Instruction manual v1.3 12
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
3 Scope of delivery
Check that the contents of the package are intact: If there are signs of damage, please contact the
manufacturer immediately. The device must not be put into operation.
Check that the contents of the package are complete and match your order:
−1 x device
−1 x 3-pin plug for power supply in service slot
−Accessories according to order/delivery note

MMD9016 −Instruction manual v1.3 13
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4 Interfaces
4.1 Interface overview
1 Display port – or – HDMI
for transmitting the image signal
2 USB 2.0 type B (slave)
for transmitting the signals from the touchscreen
3 Power supply and functional earth
2
1
3

MMD9016 −Instruction manual v1.3 14
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4.1.1 Power supply
Pin Signal
(The figure shows the socket inside the device)
1 Reference potential 0 V
2 Functional earth
(FE)
3 +24 VDC ± 20 %
The electronics are electrically isolated from the housing.
Conductor cross sections:
−AWG 18 (≙1 mm2) or AWG 16 (≙1.5 mm2).
−With cable lengths > 5 m, the larger of the two cross sections must be selected.
4.1.2 Earthing concept
ATTENTION
Risk of radio interference
The functional earth connection (FE) is necessary in order to meet the statutory
EMC requirements.
•Connect the device to a central earthing rail.
•The colour of the cable used here must not be green-yellow. This colour combination is
reserved for protective earthing.

MMD9016 −Instruction manual v1.3 15
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5 Mechanical installation
5.1 Requirements
Requirement regarding installation location:
ATTENTION
Damage caused by heat!
If the device is exposed to sunlight or any other light or heat source, it can overheat and suffer
damage.
•Do not expose the device to direct radiation by sunlight or any other light or heat source!

MMD9016 −Instruction manual v1.3 16
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5.2 Attaching flange seal
Example showing the correctly inserted seal:
Press in the seal at the corners first. Then press in evenly along each edge from the outside to the
inside in order to avoid rippling.
ATTENTION
To maintain the IP protection class: Insert the flange seal the right way round
•The side with the double lip should lie against a flat flange.
•The side with the single lip must be pressed into a groove.
ATTENTION
To maintain the IP protection class: Avoid crushing the seal!
•Tighten all flange and cover screws in a crosswise sequence and in two stages.

MMD9016 −Instruction manual v1.3 17
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5.3 Securing to VESA interface
The rear cover has a combined interface for VESA 75 and VESA 100.
1. Press the flange seal evenly into the groove on the housing side (cf. 5.2).
2. Guide all cables through the openings in the seal, flange and rear cover and plug in all connectors.
3. Use cable ties for strain relief.
ATTENTION
To maintain the IP protection class:
•Note the different hole diameters of the cable glands!
∅!
6.7-
8.3
6.0 -
7.3
3.8 -
5.0

MMD9016 −Instruction manual v1.3 18
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
4. Screw down the seal.
5. Screw on the rear cover in a crosswise sequence in two stages.
Tool: 8 mm spanner, torque: 3.5 Nm
3.5 Nm
5
7
6
8
3
4
2
1
3.5 Nm

MMD9016 −Instruction manual v1.3 19
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5.4 Securing using tube adapter
5.4.1 Attachment variants
The tube adapter can be attached to a bottom-mounted or side-mounted tube.
Tube diameter: 48.3 mm
Example showing attachment to a bottom-mounted tube:
•For example by screwing the retaining screws or threaded pins into the tube so that they lock
positively in it (make drill holes or countersinks).
•To prevent the screws/threaded pins from loosening due to vibrations and so on: Consider
using liquid thread lock.
WARNING
Risk of injury caused by the device slipping off a top-mounted
retaining tube
With a top-mounted tube, the operating company is responsible for
ensuring that the device cannot slip off the tube.

MMD9016 −Instruction manual v1.3 20
© ads-tec Industrial IT GmbH • Heinrich-Hertz-Str. 1 • 72622 Nürtingen • Germany
5.4.2 Attaching tube adapter
1. Press the flange seal into the groove on the housing side (cf. 5.2).
2. Guide all cables through the opening of the adapter and plug in all connectors.
3. Secure the cables using a cable tie at the fixtures provided.
4. Screw on the adapter. The mounting opening of the adapter can point down or to the side according
to the desired attachment variant.
5
7
6
8
3
4
2
1
3.5 Nm
Table of contents
Other adstec Monitor manuals