Scan mode. In OSD, this mark can be switched on or off by function key <F2>.
Press <ESCAPE>key to exit OSD and to return to the selected computer; the computer
name is also shown on the screen.
=Function key <F1>:To edit name entry of a computer or aSlave. First, use the <UP> and
<DOWN> arrow keys to highlight a channel then press <F1> followed by name entry.
Valid characters are ‘A’~’Z’, ‘0’~’9’and the dash character. Lowercase letters are
converted to uppercase ones. Press <BACKSPACE> to delete a letter one at a time.
Non-volatile memory stores all name entries until you change, even if the unit is powered
down.
=Function key <F2>: To switch the eye mark (N)of a computer on or off. First, use the
<UP> and <DOWN> arrow keys to highlight it, then press <F2> to switch its eye mark on or
off. If Scan Type is 'Ready PC +N', only the power-on and eye mark selected
computers will be displayed sequentially in Scan mode.
=Function key <F3>: To lock a device (a computer or a Slave)from unauthorized access,
use Security. Security is effective foronly one device (a computer or aSlave). To lock a
device, use the <UP> and <DOWN> arrow keys to highlight it, then press <F3>. Now,
enter up to 4 characters (‘A’~’Z’, ‘0’~’9, ‘-‘) followed by <ENTER> as new password. A
Security-enabled device is marked with a lock (Ï)following its channel number. To
permanently disable the security function from a locked device, highlight it, press <F3>
then enter the password.
If you want to access the locked device temporarily, simply highlight it and press <ENTER>,
the OSD will ask you for the password. After entering correct password, you are allowed to
use the device. This device is automatically re-locked once you switch to another one.
During Scan mode, OSD skips the security-enabled device. NOTE: Only one device (a
computer or aSlave) can be locked by this function at a time.
If you forget the password, the only way to permanently disable the
security function is to remove all possible power sources from the
RMD-1150 . You need to turn off all computers and unplug RMD-1150 ’s
power adapters, then restart everything.
=Function key <F4>: More functions are available by hitting <F4>. A new screen pops up
displaying more functions as described below. Most of them are marked with a triangle
(4)indicating there are options to choose from. Using the <UP> and <DOWN> arrow
keys, select the functions and press <ENTER>. Available options will be shown in the
middle of the screen. Again, using the <UP> and <DOWN> arrow keys to view options
then press <ENTER> to select it. You can press <ESCAPE> to exit at any time.
<Auto Scan
In this mode, the RMD-1150F-8automatically switches from one power-on computer
to the next sequentially in a fixed interval. During Auto Scan mode, the OSD
displays the name of the selected computer. When Auto Scan detects any
keyboard or mouse activity, it suspends the scanning till activity stops; it then
resumes with the next computer in sequence. To abort theAuto Scan mode, press
the left <CTRL> twice. Scan Type and Scan Rate set the scan pattern. Scan Type
(<F4>:More\Scan Type) determines if scanned computers must also be eye mark
selected. Scan Rate (<F4>:More\Scan Rate) sets the display interval when a
computer is selected beforeselecting the next one.