AEM SM42 AA36-ECF User manual

SPECIAL NOTICE
This product is now licensed to Anodyne Electronics Manufacturing (AEM) from Northern
Airborne Technology (NAT). AEM is responsible for all matters related to this product, including
sales, support and repair services.
Please note the transition to convert product manuals and supporting documentation is an
ongoing process and is being addressed on an ‘as needed’ basis.
All references to NAT product part numbers (and associated images) are equivalent to AEM
product part numbers.
Contact info:
Anodyne Electronics Manufacturing Corp.
#15-1925 Kirschner Road
Kelowna B.C. Canada
V1Y 4N7
Email: support@aem-corp.com
Toll Free: 1-888-763-1088
Phone: 1-250-763-1088
Fax: 1-250-763-1089
www.aem-corp.com

CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
INSTALLATION AND OPERATION MANUAL
REV 5.00 April 15, 2012
Anodyne Electronics Manufacturing Corp.
15-1925 Kirschner Road
Kelowna, BC, Canada.
V1Y 4N7
Telephone (250) 763-1088
Facsimile (250) 763-1089
Website: www.aem-corp.com
© 2012 Anodyne Electronics Manufacturing Corp. (AEM),
All Rights Reserved
SM42
AA36
-ECF
Tie Line Adapter

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
Installation and Operational Manual Page ii
ENG-FORM: 820-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
COPYRIGHT STATEMENT
© 2012 Anodyne Electronics Manufacturing Corp. (AEM), All Rights Reserved
This publication is the property of AEM and is protected by Canadian copyright laws.
No part of this document may be reproduced or transmitted in any form or by any
means including electronic, mechanical, photocopying, recording, or otherwise,
without the prior written permission of AEM.

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
Installation and Operational Manual Page iii
ENG-FORM: 820-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Prepared By:
Checked By:
Approved By:
The status of this installation and operation manual is controlled by issue shown on the title page. The
status of each section is controlled by revision shown in the footer of each page. All revisions affecting
sections of this manual have been incorporated into the latest issue.
AEM MANUAL REVISIONS
Section
Revision Number
Revision Description
Date
All Rev: 5.00
Updated
drawings and template April 15
, 2012
Tony Pearson
Designer
A
pr 15, 2012
Loen Clement
Designer
May 24/12
Tom Betzelt
Product Support
Manager
May 28, 2012

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
Installation and Operational Manual Page iv
ENG-FORM: 820-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Table of Contents
Section Title Page
1.0 Description
1.1 Introduction 1-1
1.2 Purpose of Equipment 1-1
1.3 Features 1-1
1.4 Specifications 1-1
1.4.1 Electrical Specifications 1-1
1.4.2 Physical Specifications 1-2
1.4.3 Environmental Specifications 1-2
2.0 Installation
2.1 Introduction 2-1
2.2 Unpacking and Inspection 2-1
2.2.1 Warranty 2-1
2.3 Installation Procedures 2-1
2.3.1 Warnings 2-1
2.3.2 Cautions 2-1
2.3.3 Cabling and Wiring 2-2
2.3.4 Setting NAT ICS TIE Output 2-2
2.3.5 Setting ICS OUT 2-2
2.3.6 ICS Tie Loading 2-2
2.3.7 PAX Mute Function 2-3
2.3.8 Post-Installation Checks 2-3
2.4 Continued Airworthiness 2-3
2.5 Accessories Required But Not Supplied 2-3
2.6 Installation Drawings 2-4
3.0 Operation
3.1 Introduction 3-1
3.2 General 3-1
3.3 Configuration 3-1

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 1-1
ENG-FORM: 800-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Section 1.0 Description
1.1 Introduction
This manual contains information on the AA36-ECF Tie Line Adapter. All derivatives will be covered by
manual supplements, which can be obtained from AEM as required.
Information in this section consists of purpose of equipment, features and specifications.
1.2 Purpose of Equipment
The AA36-ECF interfaces a NAT ICS tie line to non-bidirectional tie line intercom systems.
1.3 Features
The AA36-ECF is a remote bulkhead mounted unit. The input signal level is adjustable to allow correct
NAT ICS tie output levels. An internal switch provides selection to different tie line load impedances.
Allowance is made for an external switch to disable the input and output to provide the pilot with a mute
PAX conference function.
1.4 Specifications
1.4.1 Electrical Specifications
Power Supply
Normal Operating Conditions: +28 Vdc @ 110 mA max.
Operating voltages:
Nominal +27.5 Vdc
Maximum +30.3 Vdc
Minimum +24.8Vdc
Emergency +20.0 Vdc
Input Signals
ICS input:
Signal Level 500 mVrms
Impedance 4200 :r10%
AdjustTrimpot 40 dB of range
Freq. response <3 dB from 350 Hz to 6000 Hz
Distortion <1% @ rated output

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 1-2
ENG-FORM: 800-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Output Signal
ICS output:
Rated Level 500 mVrms into 5 k:
Freq. response <3 dB from 350 Hz to 6000 Hz
Distortion <10% @ rated output
Noise Level >60 dB down from rated output (without signal)
Isolation from ICS Input >35 dB
Adjust Trimpot 40 dB of range
Bi-directional Signals
AEM ICS Tie Line:
Signal Level 340 mVrms
Input impedance 1800 :r10%
Output Impedance 600 :
Freq. response <3 dB from 350 Hz to 6000 Hz
Distortion <10 % @ rated output.
1.4.2 Physical Specifications
Height 1.25" (31.75 mm)
Depth 2.48" (62.99 mm) not including connector
Width 4.50" (114.30 mm) including flanges
3.50" (88.90 mm) excluding flanges
Weight 0.41 lbs (186 g)
Mounting Remote bulkhead mount: 4 x 10-32 screws.
Material/Finish Aluminum chassis and cover with conversion coating
finish
Connectors 25-pinfiltered maleD-sub connectorwithjackposts
1.4.3 Environmental Specifications
Temperatures:
Operating -20qC to +55qC
Survival -55qC to +85qC
Altitude 35,000 ft.
Humidity 95%
Shock DO-160C Cat. M/N
Qualification:DO-160D Env. Cat. A1D1-XXB[(SBM)(UF)]XXXXXXXXXXX[UUX]MXXXX
End of Section 1.0

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 2-1
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Section 2.0 Installation
2.1 Introduction
Information in this section consists of unpacking and inspection procedures, installation procedures, post-
installation checks, and installation drawings.
2.2 Unpacking and Inspection
Unpack the equipment carefully. Inspect the unit visually for damage due to shipping and report all such
claims immediately to the carrier involved. Note that each unit should have the following:
- AA36-ECF Tie Line Adapter
- Product Information Card
- Release certification
Verify that all items are present before proceeding and report any shortage immediately to your supplier.
2.2.1 Warranty
All Anodyne Electronics Manufacturing Corp. (AEM) products are warranted for 2 years. See the website
www.aem-corp.com/warranty for complete details.
2.3 Installation Procedures
2.3.1 Warnings
Do not bundle any lines from this unit with transmitter coax lines. Do not bundle any audio or DC power
lines from this unit with 400 Hz synchro wiring or AC power lines. Do not position this unit or wiring from
this unit next to any device with a strong alternating magnetic field such as an inverter, or significant audio
interference will result.
2.3.2 Cautions
In all installations, use shielded cable exactly as shown and ground as indicated. Significant ground
loop and noise problems may result from not following these guidelines.
Use caution when routing ICS tie line wiring as they use low level signals and are prone to coupling
from other sources.
Do not take a ground from the front panel or similar location that shares a ground return with a turn and
bank, horizon or other motor driven instrument. This may cause the unit to pick up the sound of the motor
as ground loop interference.

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 2-2
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2.3.3 Cabling and Wiring
All unshielded wire should be MIL-W-22759 or equivalent. For shielded wire applications, use Tefzel MIL-
C-27500 shielded wire with solder sleeves (for shield terminations) to make the most compact and easily
terminated interconnect. Follow the wiring diagrams in Section 2.6 as required.
Allow 3 inches from the end of the wire to the shield termination to allow the hood to be easily installed.
Note that the hood is a ‘clamshell’ hood, and is installed after the wiring is complete.
All wiring should be at least 22 AWG, except power and ground lines, which should be at least 20 AWG.
Ensure that all ground connections are clean and well secured.
To prevent system failure or inadequate equipment protection, supply power from a separate 1.0 A
breaker or fuse, not connected to any other source.
2.3.4 Setting NAT ICS TIE Output
The mic signal from the Audio Controller to the AA36-ECF ICS IN is expected to be approximately 500
mVrms.
The INPUT ADJ trimpot is factory set to provide 340 mV RMS r10% on the NAT ICS TIE line, but can be
adjusted to give the desired output.
2.3.5 Setting ICS OUT
The signal level measured on the ICS tie line from the AEM audio controller/intercom system is typically
340 mVrms, which is fed into the NAT ICS TIE on the AA36-ECF.
The OUTPUT ADJ trimpot on the AA36-ECF is factory set to provide 500 mVrms r10% signal at ICS
OUT, measured across a 5 kOhm load, but can be adjusted to give the desired output.
2.3.6 ICS Tie Loading
The TIE LOAD switch and LOAD ADJ trimpot are used to match the AA36-ECF with up to four NAT ICS
tie lines.
The TIE LOAD switch is set as follows:
Number of NAT ICS Tie Lines
TIE LOAD Switch Position
1 Tie Line
1
2 Tie Lines
2
3 Tie Lines
3
4 Tie Lines
0
The LOAD ADJ trimpot is used for fine adjustment to match the AA36-ECF to the NAT ICS Tie Lines.
With the TIE LOAD switch set to the desired setting (see table above), adjust the setting of the LOAD
ADJ trimpot so that injecting a 500 mV signal at the ICS IN input gives a minimum signal across a 5
kOhm load at the ICS OUT output.

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 2-3
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2.3.7 PAX Mute Function
The AA36-ECF can be equipped with an external switch to mute all ICS signals if desired.
If the AA36-ECF is configured with the PAX Mute Function switch, verify its operation by ensuring that
there is no ICS audio in or out of the AA36-ECF when the switch is enabled.
2.3.8 Post-Installation Checks
2.3.8.1 Voltage/Resistance Checks
Do not attach the AA36-ECF until the following conditions are met.
Check the following:
a) P101 pin <1> for +28 Vdc relative to ground.
b) P101 pin <14> for continuity to ground (less than 0.5 :).
c) P101 pin <4> for continuity to ground (less than 0.5 :) when the external PAX Mute switch is
closed (see section 2.3.7 above).
Upon satisfactory completion of all performance checks, make the required log entries and
complete the necessary Regulatory Agency paperwork before releasing the aircraft for service.
2.4 Continued Airworthiness
Maintenance of the AA36-ECF is ‘on condition’ only. Periodic maintenance of this product is not required.
2.5 Accessories Required But Not Supplied
Installation kit p/n AA36-IKC (crimp) is required to complete the installation. Each kit consists of the
following:
AA36-IKC 25-pin D-min Female Crimp Kit (AEM Part No. D25SL-IKC)
Quantity Description AEM Part #
1 D-min 25 Socket Housing 20-21-025
25 MS Crimp Socket 20-26-901
1* Jack Screw Set 20-27-002
1* Lock Clip Set 20-27-004
1 25 Pin Connector Hood 20-29-026
* Use as required.

AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 2-4
ENG-FORM: 805-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
2.6 Installation Drawings
DRAWING
REV.
DESCRIPTION
TYPE
AA36
\ECF\403-0 1.00
ICS TIE Line Adapter
Interconnect
AA36
\ECF\405-0 1.00
ICS TIE Line Adapter
Connector Map
AA36\ECF\922-0
1.00
ICS TIE Line Adapter
Mechanical installation
Section 2.0 ends following the above documents




AA36-ECF Tie Line Adapter
SM42 Installation and Operation Manual
April 15, 2012 Rev: 5.00 Page 3-1
ENG-FORM: 806-0100.DOTX
CONFIDENTIAL AND PROPRIETARY TO ANODYNE ELECTRONICS MANUFACTURING CORP.
Section 3.0 Operation
3.1 Introduction
Information in this section consists of the functional and operational procedures for the AA36-ECF Tie
Line Adapter.
3.2 General
The AA36-ECF interfaces a NAT ICS tie line to non-bidirectional tie line intercom systems.
3.3 Configuration
The AA36-ECF Tie Line Adapter has no normal user operational aspects. During installation, or if the
unit has been exchanged, it may be a requirement to change internal adjustments. This should be done
ONLY BY FULLY QUALIFIED PERSONNEL.
End of section 3.0
Table of contents
Other AEM Adapter manuals