manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Uconnect
  6. •
  7. Adapter
  8. •
  9. Uconnect BLE-485C User manual

Uconnect BLE-485C User manual

BLE RS-485 Serial Adapter user manual V1.1
- 1 -
Bluet
tt
tooth V4.2 BLE
RS-422/485 Serial Adapter
Model: BLE-485C
1. Package content:
BLE RS-422/485 adapter
White Box Dimension: 11 x 6 x 5 (cm)
Total Package Weight: 105 g
Package Contents:
BLE 422/485 adapter x 1
Screw x2, Screw nut x 2
A4 User manual x 1
Mini USB Cable x 1
2. Profile:
2.1 Top view:
LED Status Description
Data LED
flash
Data transmission
Data LED solid on
No data transmission
Link LED solid on BLE Link
Link LED flash
No Link
Data & Link LED solid on
OTA Mode
TX-,TX+,RX-,RX+
Mini USB (Power)
▲
▲▲
▲
+
(5~27 VDC)
▼GND
Reset to Default
LED:
Link: Blue
PWR/Data: Red
BLE RS-485 Serial Adapter user manual V1.1
- 2 -
2. Rear view:
Setup Modbus Stop Bit
Parity Role Baud Rate
DIP9 DIP8 DIP7 DIP6 DIP5
DIP4 DIP3 DIP2 DIP1
0: Switch
1: Command
0: Normal
1: Modbus RTU
0: 1
1: 2
00: None
01: Odd
10: Odd
11: Even
0:Slave
1:Master
110:2400
111:4800
000:9600
001:19200
010:38400
011:57600
100:115200
101:230400
Remark:
1. 000000000 by default, in red bold character
2. The GATT service and AT command will support more settings than the DIP switch,
please check the page 4 section 5 and page 5 section 6.
3. Power supply:
3.1 Voltage: 5~27 VDC, Don’t exceed the limit.
3.2 There’re 3 ways to power the adapter: Mini USB, Terminal Block and pin9 of DB9,
please choose one. Don’t power the adapter by more than two sources.
3.3 The mini USB cable is inside the standard package.
4. Specifications:
4.1 Default value:
Baud rate: 9,600 bps
Data bit: 8
Parity: none
Stop bit: 1
Flow control: none
Device Name: BLE 232
DIP Switch
▲RS-485
▼RS-422
Terminal Block
BLE RS-485 Serial Adapter user manual V1.1
- 3 -
4.2 All function of COM port:
Baud Rate: 1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4/460.8/921.6 Kbps
Parity: none/even/odd
Stop bit: 1/1.5/2
Data bit: 7/8
Remark: The GATT service and AT command will support all the functions, please check
the page 4 section 5 and page 5 section 6.
4.3 Range: max. 50 m in open space
4.4 TX Power: Max. 3 dBm
4.5 RX Sensitivity: -89 dBm typical
4.6 TX current consumption of 15.6 mA (radio only, 0 dbm)
4.7 Operation Temperature: –40 °C to +70 °C
4.8 Dimensions: 81.6 mm (L) x 31.75 mm (W) x 17 mm (H)
4.9 Antenna Gain: max. 2 dB
Remark: All contents are subject to change without notice.
5. GATT Service:
5.1 Architecture:
5.2 Programming Interfaces:
Device Information
Firmware Revision String
OTIFY
RxData
BLE_CO F
MacID
Device ame
Device ame
PinID_Setting
Serial BLE Service
SetCharacteristic otification(Char)
SetCharacteristic otification
(Char)
SetCharacteristic otification(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
writeCharacteristic(Char)
Mobile APP
SERIAL
BLE RS-485 Serial Adapter user manual V1.1
- 4 -
GATT
UUID
UUID_Device Information 0000180A-0000-1000-8000-00805F9B34FB
UUID_Firmware Revision String 00002A26-0000-1000-8000-00805F9B34FB
UUID_NOTIFY (~20 bytes) 00031234-0000-1000-8000-00805F9B0130
UUID_RxData (~20 bytes) 00031234-0000-1000-8000-00805F9B0131
UUID_MacID (6 bytes) 00031234-0000-1000-8000-00805F9B0133
UUID_DeviceName (15 bytes) 00031234-0000-1000-8000-00805F9B0134
UUID_Reboot (1 bytes) 00031234-0000-1000-8000-00805F9B0135
UUID_PinID_Setting (6 bytes) 00031234-0000-1000-8000-00805F9B0136
UUID_BLE_CONF (7 bytes) 00031234-0000-1000-8000-00805F9B0132
Byte0 Byte1
Byte2
Byte3
Data bit Hwfc Stop Bit Parity Bit
7,8 0x01:on
0x00:off
2:1
3:1.5
4:2
0x02 : No Parity
0x01 : Odd Parity
0x00 : Even Parity
Byte4
Byte5
Byte6
Baud Rate Device Mode Reset To Default
00:9600
01:19200
02:38400
03:57600
04:115200
05:230400
06:2400
07:4800
08:1200
09:460800
10:921600
0x01:on
0x00:off
0x01: Reset
6. Command set via COM port:
Command Value Description
AT Check the connection status between control terminal and the RS-232
adapter. Response: “OK” when the connection is ok. Response:
“ERROR” when the connection is not ok.
AT Test the RS-232 status when first connect the adapter with the controller.
(Default) N The command will disable the auto link function.
? Inquire the current setting.
BAUD= This command is used to specify the baud rate of COM port.
The command will need 200 ms delay.
1200 1200 bps
BLE RS-485 Serial Adapter user manual V1.1
- 5 -
2400 2400 bps
4800 4800 bps
9600 9600 bps
(Default) 19200 19200 bps
38400 38400 bps
57600 57600 bps
115200 115200 bps
230400 230400 bps
460800 460800 bps
921600 921600 bps
? Inquire the current baud rate.
BIT=
7 7 data bit
8 8 data bit
? Inquire the current data bit
DEFAULT= This command is used to restore the default settings and originate a
warm start.
Y Restore the default settings (e.g. 19200 bps).
The command will re-start the system for 1 second.
DFU= Device Firmware Upgrade via PC software. OTA (Over the air) is
available to upgrade the firmware by APP
Y
ECHO= This command is used to specify whether the adaptor echoes
characters received from the UART back to the DTE/DCE.
N Command characters received from the UART are not echoed back to
the DTE/DCE.
(Default) Y Command characters received from the UART are echoed back to the
DTE/DCE.
? Inquire the current setting.
FLOW= This command enable or disable flow control signals (CTS/RTS) of the
UART port. Note, the setting is not affected by DEFAULT.
The command will need 1 second delay.
(Default) N Disable flow control.
Y Enable flow control.
? Inquire the current setting
NAME= This command is used to specify a device name for the adaptor.
You can specify a friendly name using 0 to 9, A to Z, a to z, space and –,
which are all valid characters. Note that “first space or -, last space or –
isn’t permitted”. The default name is “Serial Adaptor”.
(Default) BLE232 Default device name
xx….xx “xx….xx” is a character string with the length from 2 to 30.
R Restore the default settings name=“BLE Serial”.
? Inquire the name of the local adaptor.
PARITY= This command is used to specify parity bit setting of COM port.
The command will need 200 ms delay.
(Default) N None parity bit
O Odd parity
BLE RS-485 Serial Adapter user manual V1.1
- 6 -
E Even parity
? Inquire the current setting.
PIN= This command is used to specify a PIN code. The default PIN is
“123456”. Paired adaptors should have a same PIN. This command is
used to specify a PIN. The default PIN is “1234” and the length is not
smaller than 4. Paired adaptors should have a same PIN. The PIN code
includes the numeral and English characters.
(Default) 123456
xx….xx “xx….xx” is a 6 digit string or English character (in capital or lower case)
N Cancel authentication by PIN.
R Restore the default settings PIN=“123456”.
? Inquire the current PIN.
PROMPT= The command is used to decide whether result messages are prompted
when Setup commands are executed. The result messages are:
OK/ERROR for command execution.
(Default) Y Prompt result messages.
N Not prompt result messages.
? Inquire the current setting.
ROLE=
This command is used to specify whether the adaptor is in the central or
peripheral role. If the device role is changed, the adaptor will reboot and
all paired addresses will be cleared.
C Set the adaptor to the central role.
(Default) P Set the adaptor to the peripheral role.
? Inquire the current role of the adaptor.
STATUS= Inquire all the current setting of the adapter.
T Inquire the inner temperature of the IC in centigrade
? Display the current setting of the adapter
STOP= This command is used to specify one or two stop bits of COM port.
The command will need 200ms delay.
(Default) 1 One stop bit.
2 Two stop bits.
? Inquire the current setting.
VERSION= This command is used to inquiry the firmware version.
? Inquire the version codes.
7. Central and Peripheral: (Similar like the Master and Slave roles)
7.1 DIP switch setting: The central will pair the slave automatically, please refer to page 2
section 2.3.
Switch DIP-9 to 0 (Switch)
Switch DIP-4 to 1 (Master)
The central will link with the neighboring peripheral automatically. The blue LED will
be solid on. The central will link with the paired peripheral on next time when power on.
Please reset to the default and follow the above procedures if you want to link with
other BLE devices.
7.2 AT command: Please refer to page 5 section 6.
BLE RS-485 Serial Adapter user manual V1.1
- 7 -
Set “role=c” or “ROLE=C” in one adapter.
The central will link with the neighboring peripheral automatically. The blue LED will
be solid on. The central will link with the paired peripheral on next time when power on.
Please reset to the default and follow the above procedures if you want to link with
other BLE devices.
7.3 APP setup: Please contact the supplier to for the test APP.
The APP will search the BLE and select one as the central.
Then select the other one as the peripheral and link.
The central will link with the neighboring peripheral automatically. The blue LED will
be solid on. The central will link with the paired peripheral on next time when power on.
Please reset to the default and follow the above procedures if you want to link with
other BLE devices.
8. APP: The APP is used for the configuration and the data transmission test.
Scan and select one. Connect and configure Data transmission test.
Disconnect
TX area
RX area
Data mode
Clear data
and log
Device list
Select one
Scan BLE
Enable
Central
Setup
Reset
Default
Setup mode
Serial Port setting: Baud rate, Data
bit, Stop bit, Parity, flow control.
BLE RS-485 Serial Adapter user manual V1.1
- 8 -
APP Download:
Android:
iOS:
APP Sample code:
Please contact the supplier for the test sample code.

Other Uconnect Adapter manuals

Uconnect RS-232 User manual

Uconnect

Uconnect RS-232 User manual

Uconnect S2B5232E User manual

Uconnect

Uconnect S2B5232E User manual

Uconnect BLE-232B User manual

Uconnect

Uconnect BLE-232B User manual

Uconnect UHF User manual

Uconnect

Uconnect UHF User manual

Uconnect ZA-L2 User manual

Uconnect

Uconnect ZA-L2 User manual

Uconnect BLE-232D-E User manual

Uconnect

Uconnect BLE-232D-E User manual

Uconnect BLE-485B User manual

Uconnect

Uconnect BLE-485B User manual

Uconnect BLE-232D User manual

Uconnect

Uconnect BLE-232D User manual

Popular Adapter manuals by other brands

ForeFront Imaging VC204XE user guide

ForeFront Imaging

ForeFront Imaging VC204XE user guide

Abocom WU5204 Specification sheet

Abocom

Abocom WU5204 Specification sheet

Panasonic DVCPRO AJ-CA901P Service manual

Panasonic

Panasonic DVCPRO AJ-CA901P Service manual

RADEMACHER DuoFern Switch Adapter Plug 9472 Operating and assembly manual

RADEMACHER

RADEMACHER DuoFern Switch Adapter Plug 9472 Operating and assembly manual

TP-Link TL-PA4022P KIT Quick installation guide

TP-Link

TP-Link TL-PA4022P KIT Quick installation guide

Toto Link ZC-PLC200 user guide

Toto Link

Toto Link ZC-PLC200 user guide

NETGEAR EPS90W installation guide

NETGEAR

NETGEAR EPS90W installation guide

D-Link DHP-303 - PowerLine HD EN Starter user manual

D-Link

D-Link DHP-303 - PowerLine HD EN Starter user manual

DeLOCK 82001 user manual

DeLOCK

DeLOCK 82001 user manual

Konexx MOBILE KONNECTOR MOBILE KONNECTOR user guide

Konexx

Konexx MOBILE KONNECTOR MOBILE KONNECTOR user guide

iSystem CoreSight 20-pin user manual

iSystem

iSystem CoreSight 20-pin user manual

D-Link DUB-E100 quick start guide

D-Link

D-Link DUB-E100 quick start guide

Digitus DA-70830 user manual

Digitus

Digitus DA-70830 user manual

Tektronix P7600 Series instructions

Tektronix

Tektronix P7600 Series instructions

Belkin Bluetooth USB Adapter F8T012 user manual

Belkin

Belkin Bluetooth USB Adapter F8T012 user manual

TP-Link TL-WN322G user guide

TP-Link

TP-Link TL-WN322G user guide

Siemens FDUZ221 Installation

Siemens

Siemens FDUZ221 Installation

König Electronic P.SUP.NBC125K1 manual

König Electronic

König Electronic P.SUP.NBC125K1 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.