INSTALLATION INSTRUCTIONS
LIMITED WARRANTY
Aeromist, Inc. shall warrant the components of the 15-Nozzle Fogging Kit (Model
52469) to be free of defects in workmanship for five years. Maintenance items
are not warrantable including nozzles and filters. No warranty of merchantabil-
ity or other warranty, expressed or implied, is made.
Liability for, and the exclusive remedy for, defective materials or workmanship,
is limited to the replacement or repair of defective products. This warranty ap-
plies only to the original purchaser of the system and is not transferable. Any
parts found to be defective will be replaced at no charge. All parts must be
returned to Aeromist, Inc., freight pre-paid by customer, and will be returned to
customer by Aeromist, Inc., freight collect.
This warranty specifically excludes the following: Failure of parts due to dam-
age by accident, fire, freezing, chemicals, improper installation, or unusual
characteristics of water supply, such as mineral and calcium buildup.
This warranty covers parts only. Any costs incurred due to replacement or repair
is the responsibility of the buyer and not covered under warranty.
23610 N 20th Dr, Ste 6, Phoenix, AZ 85085
(602) 454-8900
www.aeromist.com
3-Nozzle Fog Riser (52468)
Brass End Plug (52513)
Soil Line
Connect to High-Pressure Pump
LIST OF ALL ENCLOSED PARTS
QTY PART NO DESCRIPTION
1 56401 Flexible Nylon Tubing 50 ft Roll
5 52468 3-Nozzle Fog Riser (pre-assembled)
15 52411 .012 Misting Nozzle - Fine
1 52513 Brass End Plug
TOOLS REQUIRED
Tape Measure
PVC Tubing Cutter
5/8" Open-End Wrench
9/16" Open-End Wrench
1. Connect Flexible Nylon Tubing (56401) to outlet of high-pressure pump.
2. Bury tubing approximately 6" underground. Cut Flexible Nylon Tubing (56401) with a PVC Tubing Cutter. Insert tubing into brass tee
of the 3-Nozzle Fog Riser (52468) until it bottoms out in the fitting. Complete seal with one wrench turn of fitting. Continue by con-
necting tubing from one riser to next. Space risers 2-10 feet apart as desired. Closer spacing will result in denser fog. After the last riser,
attach a short piece of tubing and terminate with the Brass End Plug (52513).
3. Flush system for several minutes before inserting nozzles. Install nozzles in 3 risers nearest the pump (hand tighten only) and flush again
for one minute. Install nozzles in each additional riser, one-at-a-time and flush again until nozzles in all risers are installed.
MAINTENANCE
• Nozzles require cleaning or replacement periodically. Clean nozzles by soaking in vinegar or calcium removal product overnight or
replace as needed.
• Winterize your misting system by draining water out of lines. Be sure all water is drained from Fog lines. This will prevent water from freez-
ing and damaging the fog line. This can be accomplished by forcing compressed air through the lines.
Warning! Fogging system is intended for outdoor use only.
• Use normal tap water or soft water only.
• Do not exceed 1000 PSI,
• Do not unscrew nozzles while under pressure
• Do not touch nozzles when system is pressurized
INSTALLATION INSTRUCTIONS
HIGH-PRESSURE PUMP
For optimum performance of your new Aeromist 15-Nozzle Fog
Kit (52469) we recommend the use of an optional 1000 PSI high-
pressure pump to create fog. This system is expandable with up
to 30 (.012 size) nozzles using our 1000 PSI Misting Pump
(60100K). Larger pumps are also available. Please see the en-
closed accessories brochure or visit www.aeromist.com for other
available pumps, upgrades and accessories.
OPTIONAL ACCESSORIES
PART NO DESCRIPTION
60100K 1000 PSI Misting Pump
56401 Flexible Nylon Tubing 50 ft Roll
52468 3-Nozzle Fog Riser (pre-assembled)
52473 1-Nozzle Fog Riser (pre-assembled)
52411 .012 Misting Nozzle - Fine
52513 Brass End Plug
52510 Brass Union
52512 Brass Tee
FREQUENTLY ASKED QUESTIONS
Q How many nozzles can I use with 1000 PSI Misting Pump
(60100K)?
A 30 nozzles and still maintain 800-1000 PSI range
Q How much fog will this create?
A Fog varies depending on temperature, humidity and spacing
Q Does this create cooling?
A Yes, this creates cooling when the fog evaporates.
Q Can nylon be buried under concrete?
Y Yes, recommend using sleeving.

This manual suits for next models

1

Popular Fog Machine manuals by other brands

TECshow STRATUS 400 user manual

TECshow

TECshow STRATUS 400 user manual

Robe X1 FT PRO user manual

Robe

Robe X1 FT PRO user manual

ADJ ENTOUR FAZE User instructions

ADJ

ADJ ENTOUR FAZE User instructions

NJD Electronics NJ421 manual

NJD Electronics

NJD Electronics NJ421 manual

Vector Fog VECTORFOG H500 instruction manual

Vector Fog

Vector Fog VECTORFOG H500 instruction manual

sky-tec 160.428 instruction manual

sky-tec

sky-tec 160.428 instruction manual

ULTRA TEC G3000 Service manual

ULTRA TEC

ULTRA TEC G3000 Service manual

XPower F-8B owner's manual

XPower

XPower F-8B owner's manual

ULTRA TEC Stage Fogger DMX Operator's manual

ULTRA TEC

ULTRA TEC Stage Fogger DMX Operator's manual

Vector Fog C20 user manual

Vector Fog

Vector Fog C20 user manual

ULTRA TEC CLF-4455 Operator's manual

ULTRA TEC

ULTRA TEC CLF-4455 Operator's manual

ULTRA TEC G3000 Operator's manual

ULTRA TEC

ULTRA TEC G3000 Operator's manual

Hybrid+ HLF1200 user manual

Hybrid+

Hybrid+ HLF1200 user manual

HQ Power VDL400SM2 user manual

HQ Power

HQ Power VDL400SM2 user manual

ULTRA TEC LSX Operator's manual

ULTRA TEC

ULTRA TEC LSX Operator's manual

LeMaitre MVS operating manual

LeMaitre

LeMaitre MVS operating manual

HQ Power HQSM10010 user manual

HQ Power

HQ Power HQSM10010 user manual

Vector Fog DC20P user manual

Vector Fog

Vector Fog DC20P user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.