Hybrid+ HLF1200 User manual

USER MANUAL
HLF1200
LOW FOG MACHINE

PAGE 2
WELCOME
Congratulations on your purchase of the HLF1200 Hybrid low fog machine, engineered and
designed by Hybrid.
PRODUCT DESCRIPTION
The HLF1200 is a new type of water mist machine that breaks the limitation of traditional
dry ice machines. The fog produced by the HLF1200 is pure and clean as it contains simple
ingredients such as: water based fog fluid and water. This allows for the fog to come out
cleaner, and in larger amounts. With a flight case appearance, it is easy to carry and
transport whenever needed.
Please read the entire manual before setting up this device.
NOTES
The maintenance cycle for the HLF1200 smoke machine is 1-2 months.
Method:
20% white vinegar
80% distilled water,
Allow to work 3-5 times after heating.
The HLF1200 only uses Hybrid smoke machine liquid, THE FLY-5 HEAVY FOG LIQUID.
It is imperative that controllers are maintained and looked after as Hybrid will not provide
spare parts without charge.
The spare parts for Hybrid machines are not suitable for other brands. Other brand spares are
not suitable for Hybrid products, as damage may occur.

USER MANUAL - HLF1200 PROFESSIONAL LOW FOG EFFECT
PAGE 3
NOTES BEFORE USE
1. Place the fog machine horizontally, and check whether it is damaged or not.
If damaged please contact the supplier at once. Unscrew the lid of the oil tank and
pour in the Hybrid smoke liquid, and then fasten the lid.
2. Before putting the power on, please verify that the power supply adheres to the rated
voltage of the fog machine. The power supply should be connected to the ground
socket. When power is on, the indicator light will turn on, and the fog machine will
begin to work. Connect the machine to the different controllers for different functions.
3. Initially, it is normal for the fog machine to create some fog or steam.
4. Place the fog machine in a ventilated area, one may run the risk of the temperature
fuse over-heating and bursting if kept in a confined space.
5. Place the fog machine on the ground in a horizontal position. The fog machine
should keep a minimum of 30cm radius away from people. Keep away from children,
fire, as well as flammables and explosive materials. Also keep nozzle within a 40cm
radius to prevent scalding.
6. Continue adding liquid to avoid damage to the fog machine’s pump and heater.
Turn off the power before adding liquid as overflowing may cause a short-circuit.
7. In the event of:
fog finishing
there is noise from pump
or the machine stops producing fog, please disconnect the power at once, and
check the liquid deposit, fuse, cable and power plug. If the problem is still not solved,
please contact the supplier.
8. Keep away from children. Do not add flammables such as oils or gas. Do not touch the wire
when the machine is running.
9. Moisture may collect around the nozzle of the machine. There may be some excess liquid
emitted from the fog machine during activity or after shut down.
10.Please make sure there is no liquid and metals inside machine before turning on the
power each time. Do not modify or repair the machine by yourself.
If there is any problem, please contact the supplier.

PAGE 4
GENERAL GUIDELINES
This device is designed for professional use on stages, in clubs, theaters, etc. The device
should only be used indoors with an alternating current of max 230V AC / 50Hz
Do not shake the device. Avoid force when installing or operating the device.
Select a location where the device is protected against extreme heat, dust and moisture.
Familiarise yourself with the function of the device before actually using it. Do not allow
operation by unqualified people. Any damage that may occur is the users responsibility.
Use the original packaging if the device is to be transported.
All modifications of the device are forbidden for safety reasons.
Only use the device for it’s intended purpose. All other uses may lead to short circuits,
burns, electric shocks, etc. Using the device in an unauthorised way will void the warranty.
This device is not suited for permanent operation. Frequent activity breaks will protect the
lifespan of your fog machine.
Disconnect the device from the electrical supply to clean it. Alternatively clean the fog
machine when it is not in use. Handle the power cord by the plug only.
Do not switch the device on immediately after it has been exposed to extreme
temperature changes. Protect the device against damage by leaving it switched off until it
has reached room temperature.
Note that damage caused by user modification to the device is not covered by the warranty.
Keep the device away from children and unauthorised users.

USER MANUAL - HLF1200 PROFESSIONAL LOW FOG EFFECT
PAGE 5
INSTALLATION
Have the device installed by a qualified person, respecting EN 60598-2-17 and all
other procedures.
The area where the fog machine has been placed, must be able to support 10 times
the weight of the device for a minimum of one hour without warping.
Never stand directly below the device when it is being mounted, removed or serviced.
Have a qualified technician check the device once a year, and once the fog machine
has been used.
Install the device in a location with little traffic and that is inaccessible to
unauthorised persons.
Make sure there is no flammable material within a 50cm radius of the device.
Connect the device to the main electric supply with the power socket.
The installation needs to be approved by an expert before the device is active or
taken into service.
USE / SETUP PROCESS
HLF1200 Operation
1. Place smoke machine on a dry flat surface.
2. Add liquid carefully to the tank, and do not overfill.
1
The water level in the
tank should not pass
the mesh of the tank
Fill the lids gutter with
water and plug hold
closed with plug provided
Place weather tape provided
on the output spout of the low
fogger before attaching the pipe.
Once done, crimp pipe firmly
with the hose clamp provided
2
3
3.

PAGE 6
4. Plug the power cord into an electrical supply. Turn the power switch to “ON” found on the
back of the machine.
5. The device will take a couple of minutes to warm up. During this time the machine cannot
generate smoke.
Model HLF1200
Voltage 220V AC / 50HZ
Power 1300W
Current-limited safety device 10A
Preheating time 6min
Smoke output 10 000Cu ft/min
Capacity of oil tank 0.8L
Wire Controller X-2
Wireless Controller W-2
DMX 2ch
Water Mist 1000 ± 9000(ml/hr)
Gross weight 23.84kg
Packaging (mm) 700 x 405 x 480mm
TECHNICAL SPECIFICATIONS

USER MANUAL - HLF1200 PROFESSIONAL LOW FOG EFFECT
PAGE 7
PRODUCT WARRANTY INSTRUCTIONS
The warranty card and purchase invoice is required as Hybrid / distributors will require
documentary evidence when a warranty service is needed. Please keep your warranty card
in good condition.
Instructions:
Warranty period: maintenance free for one year (The warranty is valid from the
date of purchase).
If the product does not use Hybrid liquid, the warranty period will be shorten to
three months. The cost of replacing spare parts will be of the users.
The warranty is void when:
The device has been misused or incorrectly managed, e.g. blown fuses caused by
overload or the excess of voltage
The device has been damaged due to the transportation of it.
The machine is faulty due to poor use, e.g. moisture, unstable voltage etc.
The product has been altered by anyone other than a qualified Hybrid technician.
Exclusions: Packaging, casing and bracket of the product and battery inside
wireless remote controller.
Hybrid will not charge for the maintenance and spare parts of the product,
provided that it has remained within the guidelines of the user manual, as well as
with the terms of the warranty. In regard to the products which exceed their
warranty period, Hybrid will only charge for the cost of the spare parts accordingly.
Hybrid reserves the right of final explanation for the content of the warranty card.
If there is anything unclear, please contact the dealer.

www.vivaafrika.co.za
WARRANTY CARD
Model:..................................................................................................................................................
Name:..................................................................................................................................................
Date of purchase:.................................................................................................................................
Dealer name:.......................................................................................................................................
Address of dealer: ....................................................... Province:.......................................................
NOTE: Fill out the warrant card clearly so that we can assist you. Please send back the
machine with warranty card for repairs.
RECORD CARD FOR MAINTENANCE
Maintenance Indicator (for user):...................................................................................
Maintenance time (for Manufacturer):........................................................................
Fault (for Manufacturer):..........................................................................................
Maintenance Indicator (for user):.......................................................................
Maintenance time (for Manufacturer):............................................................
Fault (for Manufacturer):...............................................................................
Maintenance Indicator (for user):............................................................
Maintenance time (for Manufacturer):.................................................
Fault (for Manufacturer):....................................................................
Table of contents
Other Hybrid+ Fog Machine manuals
Popular Fog Machine manuals by other brands

Smartek
Smartek NUBI 4.0 F1 quick start guide

Show Technology
Show Technology SHOWPRO Venue Haze 1200 user manual

Algam Lighting
Algam Lighting S900 user manual

thomann
thomann Stairville AF-150 DMX user manual

Stageline
Stageline FM-1510 instruction manual

Chauvet DJ
Chauvet DJ Geyser T6 Quick reference guide