Connecting Three SRX-500 Speakers
TheThreeSRX-500speakers(eachspeakercanhandle
400W of power) should be wired in parallel as shown in
figure.Theresultingimpedance ofthespeakersystem is
2.66 . Thus they should be connected to the 2 tap of
theamplifier.
High Impedance Speakers or Speakers Using A
100V Line Matching Transformer
lOnly Driver Units / Horn Speakers / Column Speakers
with 100V Line Matching Transformers are to be
connected to COM-70V / 100V Terminal Strip.
lThe Box Speaker / Driver Unit switch must be kept at
Driver Unit position.
lWhen any of the above speakers are connected to the
COM-70V / 100V Terminal Strip then NO Box speakers
shouldbeconnectedtotheCOM-2 /4 TerminalStrip.
lThe power drawn from the amplifier should not exceed
1000Watts.
ConnectingSeventyDriverUnitswith100VLMT
100 Driver Units with 100V Line Matching Transformer
connected at 10 Watts tap can be operated.
Connecting a Combination of Driver Units and
ColumnSpeakerswith100VLMT
60 Driver Units with 100V LMT at 10 Watts and 80
Column Speakers with 100V LMT at 5 Watts can be
connected together. The power drawn from the amplifier
shouldnotexceed1000Watts.
1
20W
15W
10W
5W
2
20W
15W
10W
5W
60
20W
15W
10W
5W
10W
7.5W
5W
1
10W
7.5W
5W
2
10W
7.5W
5W
COM
COM
COM COM
COM
COM
10
Speaker Connection Guidelines....
Resultant Impedance = (8 Ohm / 3) = 2.66 Ohm
COM 2 4
COM 70V 100V
1
20W
15W
10W
5W
2
100
COM
20W
15W
10W
5W
COM
20W
15W
10W
5W
COM
COM 70V 100V
COM 70V 100V
80
SSA-10000
+
-
SRX-500
8
+
-
SRX-500
8
+
-
SRX-500
8
Connecting a combination of Wall and Ceiling
Speakerswith100VLMT
130 Ceiling Speakers with 100V LMT at 4 Watts and
80 Wall Speakers with 100V LMT at 6 Watts can be
connected together. The power drawn from the amplifier
shouldnotexceed1000Watts.
Useof 70VoltLine
A loudspeaker / Driver Unit with its LMT adjusted to the
15W tap, when connected to COM and 100V terminals
on the Amplifier's Terminal Strip will draw 15W from the
Amplifier but when the same is connected to COM and
70V it will only draw half power i.e. 7.5W. A good use of
70V line tap can be made in installations where large
number of Speakers / Driver Units are to be installed for
moreevendistributionofsound.
Correct Phasing of Loudspeakers
lWhen two or more Speakers / Units are installed in the
same area and are facing the same direction, it is
essential that their cones / diaphragms act in unison.
Otherwise the sound level of one speaker will be
cancelling the sound level of the other. To avoid any
mistake, the terminals of Box speakers and the Driver
Unitsaremarked '+' &'-'.AlwaysconnecttheCOMofthe
Amplifierto'-'ofspeaker&2 /4 of the amplifier to the
'+'ofthespeakers.
lIn case of LMT’s the COM of all the LMT’s should be
connected to the COM of the red strip terminal of the
amplifier and the power tap to 100V line as shown in
figure.
IMPORTANT
l
l
When 70 / 100 Volt line is being used, no speakers / driver units should be connected to 2 / 4 (Low
Impedance)Tap.
Loudspeaker / driver unit should be connected to either COM-100V or COM-70V terminals, but never to
morethanonesetofterminals.
-
+
11
Speaker Connection Guidelines....
1
2W
1W
4W
COM
2
2W
1W
4W
COM
130
2W
1W
4W
COM
1
3W
1.5W
6W
COM
2
3W
1.5W
6W
COM
80
3W
1.5W
6W
COM
COM 70V 100V
SSA-10000