Prohibited Do not dismantle unit Keep unit away from water General precautions
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric
shock could result.
2. Do not connect any non-specified power source to
the +, - terminals. Also, do not install two power supplies in
parallel to a single input. Fire or damage to the unit could
result.
3. Keep the unit away from water or any other liquid.
Fire or electric shock could result.
4. Do not put any metal or flammable material into the
unit through the openings. Fire, electric shock, or unit
trouble could result.
5. Do not connect any terminal on the unit to an AC
power line. Fire or electric shock could result.
6. Do not use power supply with a voltage other than
specified. Fire or electric shock could result.
7. Keep AC cord from being marred or crushed. If the
AC cord is damaged, fi re or electric shock could result.
8. Do not plug or unplug unit with wet hands. Electric
shock could result.
9. Insert AC plug completely and securely into AC
outlet.
Otherwise, fi re or electric shock could result.
10. Periodically check for and remove dust on the
power plug. If dust is left, it could cause the power plug to
heat up, resulting in fire.
11. Do not put any metal or flammable material into
the unit through the openings. Fire, electric shock, or unit
trouble could result.
CAUTION
Negligence could result in injury or damage to
property.
1. Do not install or make any wire terminations while
power supply is plugged in. It can cause electrical shock or
damage to the unit.
2. When mounting the unit on a wall, install the unit in a
convenient location, but not where it could be jarred or
bumped. Injury could result.
3. Before turning on power, make sure wires are not
crossed or shorted. Fire or electric shock could result.
4. Do not install the unit in locations subject to frequent
vibration or impact. It may fall or tip over, resulting in
damage to the unit or personal injury
5. For power supply, use Aiphone power supply model
specified for use with system. If non-specified product is
used, fi re or malfunction could result.
6. Do not apply high pressure on the screen. If
fractured, injury could result.
7. If LCD is punctured, do not touch the liquid crystal
inside. Inflammation could result. If contact should occur,
flush or rinse area with water thoroughly and consult your
doctor.
8. Do not put anything on the unit or cover the unit with
cloth, etc. Fire or unit trouble could result.
9. Do not install the unit in any of the following
locations. Fire, electric shock, or unit trouble could result.
* Places under direct sunlight or near heating equipment
that varies in temperature.
* Places subject to dust, oil, chemicals, hydrogen sulphide
(hot spring).
* Places subject to moisture and humidity extremes, such
as bathrooms, cellars, greenhouses, etc.
* Places where the temperature is quite low, such as inside
a refrigerated area or in front of an air conditioner.
* Places subject to steam or smoke (near heating or
cooking surfaces).
* Where noise generating devices such as dimmer
switches or inverter electrical appliances are close by.
10. Be sure to perform a call test or check the volume
with the handset on the hook. If you operate the hook
switch with the handset on your ear, a sudden call etc.
may arrive causing damage to your ear.
11. The unit must be installed and wired by a qualified
technician.
GENERAL PRECAUTIONS
1. Keep the unit more than 1 m (3.3') away from radio or
TV sets.
2. Keep the intercom wires more than 30cm (12'') away
from AC 100-240V wiring. AC induced noise and/or unit
malfunction could result.
3. Comply with all third party manufacturing specifications
that will be used with this system (sensors, door releases,
etc.).
4. If it is used close to a cellular phone, the unit may
malfunction.
5. The unit can be damaged if dropped. Handle with care.
6. The unit will not work during power failure.
7. In areas where broadcasting station antennas are close
by, the intercom system may be affected by radio
frequency interference.
8. All the units, except for door stations, are designed for
indoor use only. Do not use at outdoor locations.
9. This product, providing door release, should not be used
as a crime prevention device.
10. Please note the LCD panel, though manufactured with
very high precision techniques, inevitably will have a very
small portion of its image elements always lit or not lit at
all. This is not considered a unit malfunction.
11. Environmental sound around the unit may hinder
smooth communication, but this is not a malfunction.
12. The unit has audio monitoring function between
residential stations. When using this function for baby
monitoring, never install the unit within reach of children to
prevent strangulation with coil cord or wires.
NOTICES
We will under no conditions be liable for damage
occurring due to the inability to communicate due to
malfunctions, problems, or operational errors in this
product.
We will under no conditions be liable for any damages
or loses resulting from this product's contents or
specifications.
This manual was created by Aiphone Co., Ltd., all
rights reserved. Copying, in part or in whole, this
manual without prior permission from Aiphone Co.,
Ltd. is strictly forbidden.
Please note that images and illustrations depicted in
this manual may differ from the actual ones.
Please note that this manual may be revised or
changed without prior notice.
Please note that product specifications may be
changed for the sake of improvement without prior
notice.
This system is not intended for life support or crime
prevention. It is a supplementary means of conveying
information. Aiphone will under no conditions be liable for
loss of life or property which occurs while the system is
being operated.

AIPHONE 22.07.15 –V1.1
PACKAGE CONTENTS
Verify that the following parts are included.
[1] [2] [3]
[4] [5]
Package contents:
[1] Installation Manual [2]Operation Manuel
[3] JPTLIIPA Interface [4] Power supply [5] Quick set up
INSTALLATION
Location for mounting
JPTLIIPA interface can be:
- placed on a furniture
or - fixed on the wall: to do this action, it must be fixed with 2 crews with plugs adapted of the
supporting material.
Don’t install JPTLIIPA near heating equipment that varies in temperature and near subject to
moisture and humidity extremes.

AIPHONE 403.07.15 –V1.0
Description
Status light
JPTLIIPA interface status
Solid green light
Interface initialization processing
1-blinking every seconds
Interface is ready for a correct use
3-blinking every seconds
JPTLIIPA Interface has not found IP address, it’s start
with set up address: 192.168.0.100
4- blinking every seconds
JPTLIIPA interface has no connection with the
AIPHONE’s server
5-blinking every seconds
Interface is not registered on AIPHONE’s server
JPTLIIPA interface allow audio and video call transfer from the AIPHONE JP series door station to 2
smartphones with Androïd or Apple software.
ATTENTION!
To get an audio or video good reception, your smartphone must receive phone calls by WIFI or
3G/4G (3G minimum) mode. In case of bad reception, picture will be quality less. If the network
is not cover by 3G/4G, you will receive only audio call from the door station.
Interface is a plastic black box with the following dimensions 240 x 180 x 55 (h) mm
This interface has to be connected to your internet network and to your JP video kit.
JPTLIIPA interface has to be connected to the 230 V / 12V power supply (included) respecting the
polarities.
Smartphones
Door station Master station IP Interface (5 maxi)
Or or
Status light
ON / OFF
USING THE SYSTEM

AIPHONE 503.07.15 –V1.0
The JPTLIIPA must connect to a modem or to a private box.
When a call is placed on the Door Station, the image from this one appear on the video station and
send automatically the video onto 2 Smartphone. Without answer with the Smartphone, the JPTLIIPA
goes back into Stand-by mode into the next call.
1 –BASIC USER OPERATION
Few functioning parameter are available and can be set following the customer needs. For that, some
options can be program (see Installation Manual §4).
1.1 VISITOR CALL
When the door Button is push, the call is send onto 2 Smartphone throw your interface and your
private box (or modem).
If one of the 2 Smartphone answer, the communication is establish between you and the visitor.
You are inform that you are in communication mode by a screen change on your smartphone.
You can choose the “Door opening” function by choosing the “Key” Symbol.
For open the door, you must choose between 3 Door relay onto a confirmation screen:
-Contact#1 with the 1st « Key » symbol
-Contact#2 with the 2nd « Key » symbol
-Optional Relay with « Activate option » for using the JPTLIIPA Relay
The communication is stopped when press the « end communication » Button or when the
communication timer is over (3 minutes).
If no Smartphone answer after a delay of 50sec or if they are already in communication, the
interface goes into Stand-By Mode until a next call.
1.2 MODE SELECTION
Mode « OFF »
The selector is on ‘OFF’.
In this mode, if the visitor presses the Call-button, only JP4MED is ringing.
Smartphones
Door Station Master Station Interface (5 maxi)

AIPHONE 603.07.15 –V1.0
Mode « ON »
The selector is on ‘ON’
In this mode, if the visitor presses the Call-button, JP4MED station rings and the smartphone.
Smartphones
Door Station Master Station Interface (5 maxi)
PARAMETERS OF THE INSTALLATION
Fill this charts with the new settings of your installation.
PROGRAMMING
Default Value
Installation
Operating time of the relay 1
5 seconds
(Door1 Name)
Operating time of the relay 2
5 seconds
(Door2 Name)
Operating time of the relay 3 (JPTLIIPA)
5 seconds
(Optional Relay Name)
Operating time of the relay 4 (JPTLIIPA)
5 seconds
(Optional Relay Name)
Operating time of the relay 5 (JPTLIIPA)
5 seconds
(Optional Relay Name)
End of communication after activation of relay 1
No
End of communication after activation of relay 2
No
End of communication after activation of relay 3
No
End of communication after activation of relay 4
No
End of communication after activation of relay 5
No
JPTLIIPA S/N:

AIPHONE 703.07.15 –V1.0
QUICK DEBUG
DEFAUTS
VERIFICATIONS
The JPTLIIPA Status Led don’t turn ON
- Check the Power Adaptor is well plugged
The call activate to the JP4MED but not
activate the JPTLIIPA Interface
- Check the selector is on « ON » Position
- Check the connection on the « LAN » Connector
- Check that wire is well plug on the modem or on
the private box
- Check the smartphone has been registered
- Check the « AiphoneJP » application is launch
- Check the Status Led is blinking 1 time each
seconds (if not, please contact your installer).
QUICK START:
AiphoneJP APPLICATION FONCTION
1 / Flash the 1st QR code for downloading the application
2/ Flash the 2nd QR code for registering the 1st smartphone
3/ Flash the 3rd QR code for registering the 2nd smartphone
4/ Flash the 4th QR code for registering the 3rd smartphone

AIPHONE 803.07.15 –V1.0
Fonction
Smartphone
Application Launching
Launching Screen :
Running Application : you can receive call
To return to Stand-by Mode, push the IPhone “Home” Button

AIPHONE 903.07.15 –V1.0
To permit the application remains in stand-by mode, you
must activate the “AiphoneJP” notifications:

AIPHONE 10 03.07.15 –V1.0
Call answering
Calling screen : screenshot form the visitor :
Push , Audio / Video communication begin :
If you push the JPTLIIPA go Stand-by Mode.
Caution! The call will not send to the voice mail.
If the area is not covert by 3G/4G network, you will only have
audio call :

AIPHONE 11 03.07.15 –V1.0
Disabling function
During the conversation, you can :
- Activate or deactivate the smartphone speaker with . The
symbol below become red: the speaker is deactivate.
- Activate or deactivate the micro (private mode) with . The
symbol below become red: the micro is deactivate.
- Activate or deactivate the video with . The symbol below
become red: the video is deactivate.

AIPHONE 12 03.07.15 –V1.0
Door opening and optional
relay
During the call, press the « key » symbol
This screen appear :
Move the green symbol to the grey symbol
For opening the 1st Entry choose :
For opening the 2nd Entry choose :
For activate the optional relay (3rd Entry or else) choose :

AIPHONE 13 03.07.15 –V1.0
Alarm Functioning
Alarm Activated Screen:
When the key “ ”, you will have the message “ Alarm
activated” and the following screen

AIPHONE 14 03.07.15 –V1.0
•Operating temperature: 0°C - 40°C (32°F –104°F).
• Cleaning: use a soft duster with neutral detergent.
• Dimensions: 260 x 180 x 54 (h) mm
• Weight: 0,180 kg
Connections: (1) Ethernet network
(2) Bus JP
Telephones: (1) Smartphones Android or IPhone
Power supply: 12V DC –0,5A
Consumption: Stand-by 350mA, when relay is on 430mA.
Standards: EN60950
EN55022 Edition 98 Classe B
EN55024 Edition 98 Classe B
Exit Contact: 3 (N.O., N.F.)
Programming: By Internet.
Saving of parameters: No volatile memory
Material : ABS module
TECHNICAL PRECAUTIONS
SPECIFICATIONS

AIPHONE 15 03.07.15 –V1.0

AIPHONE 16 03.07.15 –V1.0
Distributed par AIPHONE
Print in France
Table of contents
Other Aiphone Network Card manuals
Popular Network Card manuals by other brands

National Instruments
National Instruments NI 9225E operating instructions

National Instruments
National Instruments Gigabit Ethernet Adapters installation guide

Sabrent
Sabrent Network Card user manual

Yamaha
Yamaha RCX series user manual

HID
HID EH400 installation guide

Aztech
Aztech NETCARD AZ-NC2100 user manual